Records from 2009 to 2025. Most recent: inspection, 13 January 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 54
13 January 2025
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8062801
9 September 2024
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7999054
23 May 2024
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7947889
29 January 2024
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7857715
18 December 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7840217
2 October 2023
Inclining Experiment
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7801962
21 September 2023
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7813789
10 July 2023
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7742605
6 March 2023
Examination of Repairs · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7646543
6 March 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7647579
3 March 2023
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7645140
3 March 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7646843
12 January 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7620526
5 January 2023
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7617485
20 December 2022
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7625741
9 December 2022
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7606942
9 December 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7610802
17 November 2022
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7596199
17 November 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7596707
17 August 2022
In-Service Inspection · Examination of Repairs · Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7564218
25 May 2022
COI Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7437397
8 April 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7427370
6 April 2022
In-Service Inspection · Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7425482
20 December 2021
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7370850
14 July 2021
Examination of Repairs · Damage Survey · Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7345160
1 June 2021
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7221120
2 November 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7088254
24 September 2020
Annual Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7063790
11 March 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6925108
13 February 2020
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6908657
1 November 2019
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6849036
9 October 2019
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6831645
1 August 2019
Hull Examination · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6789617
23 April 2019
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6703312
9 April 2019
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6658876
9 April 2019
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6665453
31 October 2018
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6573461
25 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6548247
18 June 2018
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6473967
13 February 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6354336
5 February 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6353934
25 January 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6353861
8 January 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6336351
14 December 2017
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6322116
26 October 2017
Administrative Inspection · Damage Survey · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6297418
11 October 2017
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6285259
25 September 2017
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6274813
11 June 2017
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6173693
16 December 2016
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6059084
28 October 2016
In-Service Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6034499
21 October 2016
Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6026920
10 June 2016
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5923291
8 June 2016
Hull Examination · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5902364
6 April 2016
Plan Review (Other than "T") · Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5931586
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2024
No resolution recorded
port side engineroom vents are damaged & should be repaired or replaced; wastage sighted at both ladderwell windows; forward draft marks are not correct; vessel does not have loading marks, confirm whether required or not, properly apply if required.
Action required: 705 - Other - as specified
Due 1 November 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 May 2024
No resolution recorded
Pilothouse MDE oil pressure gauge inoperative/erratic & unreliable, must be corrected
Pilothouse MDE emergency stop inoperative, must be corrected
Pilothouse MDE alarm panel inoperative, must be corrected
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 May 2024
No resolution recorded
MDE emergency fuel shut-off mechanism needs to be adjusted or modified to ensure complete closure and reliability
** corrected but still needs additional routing to be considered permanently repaired.
Action required: 10 - Deficiency Rectified
Due 5 June 2024 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2024
Resolved
Port side genset inoperative due to faulty starter. Company is awaiting replacement part. Complete repairs and demonstrate proper operation to attending CG Marine Inspector. Vessel must be provided with and maintain battery back-up power for vital systems until second genset is repaired & operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 7 February 2024
Resolution: genset repaired.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 January 2024
Resolved
Crew is unable to provide accurate documentation/attestation to the amount of cargo/baggage that is carried. This is in direct contradiction to the vessels issued stability letter. The carriage of passengers and cargo/baggage combinations is not authorized until accurate weight calculations can be obtained for the vessels crew/shore-side facility personnel and presentable to the OCMI.
Action required: 705 - Other - as specified
Due 29 January 2024
Resolved 27 March 2024
Resolution: attended to witness cargo weighing and subsequent calculations and loading operations by the crew. Crew able to accurately assess cargo weight and load the vessel in accordance with the vessels stability letter.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 18 December 2023
Resolved
1 pilothouse window is cracked and must be replaced.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 January 2024
Resolved 18 January 2024
Resolution: window replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2023
Resolved
All dead-end wiring must be properly terminated &/or removed. Any new wiring installations must be properly approved prior to installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2023
Resolved 2 January 2024
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 December 2023
Resolved
Vessels engine room has accumulation of oil on the machinery and oil/trash on deck plates and in the bilges, all must be properly cleaned.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 December 2023
Resolved 2 January 2024
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 October 2023
No resolution recorded
Auxiliary heating boiler has been installed by reputable vendor with Marine Inspector oversight, however submitted installation plans & equipment list have yet to be approved by the MSC. Until approval is granted, installation confirmed to be in compliance with these approved plans (to include an emergency fuel shut-off valve), hydrostatic test & operational testing of all the installed safety devices are witnessed by CG MI, operating the boiler is prohibited.
Action required: 705 - Other - as specified
Due 31 October 2023 — due date passed with no resolution recorded
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2023
Resolved
Maindeck overhead sprinkler system diffuser heads must be standardized, both relating to type and position.
Correct prior to "winter season" operations.
Action required: 705 - Other - as specified
Due 1 November 2023
Resolved 31 October 2023
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2023
Resolved
Pilothouse emergency comms battery requires proper cover.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 3 August 2023
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 July 2023
Resolved
Gensets do not have emergency fuel shut-offs. Install & demonstrate proper operation.
Correct prior to "winter season" operations.
Action required: 705 - Other - as specified
Due 1 November 2023
Resolved 31 October 2023
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2023
Resolved
Cover missing from electrical J-box under stbd side of helm. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 July 2023
Resolved 3 August 2023
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 July 2023
Resolved
Several wasted areas sighted at maindeck forward area outboard by loading doors.
Correct prior to "winter season" operations.
Action required: 705 - Other - as specified
Due 1 November 2023
Resolved 31 October 2023
Resolution: repairs completed, NDT witnessed, all sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 March 2023
Resolved
While underway carrying passengers en route to Mackinac Island, Captain reported feeling a resistance in the steering system. Upon investigation deckhands found the forward-most chain knuckle in the steering shaft to be cracked. This is the second time in three days the steering had bound up and caused this same knuckle to crack under heavy torsion. Upon inspection, MI found that the steering shaft had shifted approximately 1/4 to 3/8's of an inch at numerous spots along the joints and unions. As well as the key had rolled in the key-way at the section where the shaft reduces from 1 1/2 down to 1 inch.
Submit repair proposal to this office for approval in correcting failures occurring in the steering system and, once approved, affect repairs to the satisfaction of the attending Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 March 2023
Resolved 8 March 2023
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 January 2023
Resolved
Mechanics found flattened cam lobe on MDE. Effect repairs and confirm safe operation via underway trials with Coast Guard Marine Inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 January 2023
Resolved 11 January 2023
Resolution: Corrected.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 November 2022
Resolved
Locally fabricated steering gear pillow block/bearing must be replaced with a properly manufactured and system appropriate pillow block/bearing.
Installation and operational testing must be witnessed by attending CG Marine Inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2022
Resolved 29 November 2022
Resolution: Replaced, ops check witnessed, all sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 October 2022
Resolved
Replace rejected (burst) maindeck fire hose.
Action required: 17 - Rectify deficiencies prior to departure
Due 31 October 2022
Resolved 31 October 2022
Resolution: replaced.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 25 May 2022
Resolved
Sighted many areas of concern relating to corrosion/wastage. Areas included: lazarrette, stairs to 2nd deck, port side mooring bits, holding tank compartment, accommodation space outer edges, pilothouse landing and deck, along with port qtr damage.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 31 October 2022
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2022
Resolved
Engineroom – sighted MDE oil leak, MDE exhaust leak, throttle/transmission linkage needs to be professionally assembled with proper hardware.
Oil leak on genset at dipstick requires repair/replacement.
Transmission oil temp alarm constantly on in pilothouse, sensor/transducer on order.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 June 2022
Resolved 26 October 2022
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 May 2022
Resolved
Found 1-50 person IBA servicing expired April 2022.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2022
Resolved 31 October 2022
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 May 2022
Resolved
Found all 4 IBAs painter lines not properly secured. Instructed crew how to properly install & regularly inspect.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2022
Resolved 25 May 2022
Resolution: corrected
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 April 2022
Resolved
Vessel experienced a loss of steering while transiting between Mackinac Island and St. Ignace, MI. The cause appears to be damage sustained to the rudder by ice.
Assess damage, submit repair proposal to OCMI, repair IAW approved plan, demonstrate proper operation prior to carriage of passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2022
Resolved 19 April 2022
Resolution: Repairs completed, underway operational test completed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 June 2021
Resolved
Vessels 4-50 person permanent IBAs servicing has expired; IBAs must be sent out for annual servicing.
Vessel is not authorized carriage of passengers until IBAs are serviced or replaced & the OCMI is notified.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2021
Resolved 3 November 2021
Resolution: IBAs serviced and properly installed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 June 2021
Resolved
Make vessel available for underway operational testing, demonstrate emergency drills. All to be witnessed by CG Marine Inspectors.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 June 2021
Resolved 3 November 2021
Resolution: completed.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 September 2020
Resolved
Clean and descale port side sewage void and schedule CG Marine Inspector to attend and inspect.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2020
Resolved 2 November 2020
Resolution: Corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 September 2020
Resolved
Fire extinguisher bracket is loose on the deck in engine room. Secure fire extinguisher bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2020
Resolved 27 October 2020
Resolution: Corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 September 2020
Resolved
Label GENSET with de-rating placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2020
Resolved 2 November 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2020
Resolved
Remove extension cords from under the port bridge console, passenger cabin, and aft life jacket storage. They have been there for some time and are no longer temporary.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2020
Resolved 27 October 2020
Resolution: Corrected.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 September 2020
Resolved
Flange on fire main pump is leaking. Effect repairs to make pump not leak into engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 October 2020
Resolved 26 October 2020
Resolution: Corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2020
Resolved
Secure/ remove exposed wiring in the forepeak overhead.
46 CFR 183.01-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 February 2020
Resolved 30 June 2020
Resolution: Added junction box.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 November 2019
Resolved
Vessels 4-50 person permanent IBAs have been sent out for annual servicing. Replacement IBAs total capacity is 160 persons (2-50 person & 2-30 person). Vessel is limited to 320 total persons allowed until permanent IBAs are re-installed.
Action required: 705 - Other - as specified
Due 1 November 2019
Resolved 11 March 2020
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2019
Resolved
A quarter sized crack is present on the stbd side, 6 inches from the keel, in the void aft of the forepeak. Submit repair proposal for approval and effect permanent repairs to hull plating to the satisfaction of the attending marine inspector prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 April 2019
Resolved 16 September 2019
Resolution: permanent repairs completed as part of credit hull exam.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 October 2018
Resolved
Bilge suction piping wasted, leak caused loss of suction, corrected during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 November 2018
Resolved 2 November 2018
Resolution: Piping section renewed in kind during inspection.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018
Resolved
The vessel is currently broadcasting (1) Improper MMSI Number, (2) Improper Call Sign, (3) Improper Ship Type. Ship Type should be a two digit number (60) Per the US Official Encoding guide.
Condition: Invalid
Action required: 705 - Other - as specified
Due 25 October 2018
Resolved 6 December 2018
Resolution: Owner corrected errors.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 18 June 2018
Resolved
Wastage identified in internal structural members. Areas identified to be cropped and renewed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2018
Resolution: Areas identified were renewed and tested satisfactorily.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 June 2018
Resolved
Hatch covers leak and need to be maintained or renewed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 October 2018
Resolution: Hatch covers were renewed and tested.
Fire Fighting › Combustible Materials › Insulation
Issued 27 December 2017
Resolved
Provide oil resistant insulation to prevent combustible materials from coming into contact with hot surfaces of engine exhausts for main engine and ship service generators.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2018
Resolved 5 February 2018
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 27 December 2017
Resolved
Discharge end of fuel tank vent piping shall be fitted with a removable flame screen made of corrosion resistant wire in at least 30 X 30 mesh.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2018
Resolved 5 February 2018
Stability › Weathertight Integrity › General
Issued 27 December 2017
Resolved
Demonstrate proper operation of engineroom access door; must be weathertight and securing devices must work properly as per 46 CFR 116.1160.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2018
Resolved 25 January 2018
Construction/Loadline › Hull › Transverse Frame
Issued 11 October 2017
Resolved
Determine extent of steel wastage in internal structures and hull plating in way of forepeak void and 1st void abaft the collision bulkhead, and complete permanent repairs to same, prior to operating in commercial service.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 8 December 2017
Resolution: Repairs completed on transverse frames in forepeak and 1st void abaft of collision bulkhead. Hull gauging completed.
Personnel › Training › Cargo Safety
Issued 25 September 2017
Resolved
Complete appropriate hazardous material employee training prior to the carriage of hazardous materials.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 February 2018
Resolved 13 February 2018
Engineering › Steering Gear System › Linkage
Issued 11 June 2017
Resolved
Make permanent repairs to steering system and demonstrate proper operation of same to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 19 June 2017
Resolved 12 June 2017
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 October 2016
Resolved
Post EAP policy and hotline information wither oin vessel or at crew time-clocks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 October 2016
Resolved 28 October 2016
Resolution: Sighted policy on board vessel and company rep stated it is now posted at each time clock as well.
Stability › Freeing Ports › General
Issued 21 October 2016
Resolved
Permanently repair broken non-return flap on freeing port in way of port bulwark next to engineroom access.
Condition: Improper/Lack of Maintenance
Due 21 November 2016
Resolved 28 October 2016
Resolution: Flap now functions properly.
Engineering › Fuel Oil Service System › Piping
Issued 21 October 2016
Resolved
Reconfigure fuel supply piping to aft ship service generator to eliminate risk of damage.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 28 October 2016
Resolution: Completed. Generator fuel supply piping and filter system reconfigured and now mounted on forward engineroom bulkhead in a manner as to not interfere with transiting that area.
Engineering › Bilge Water Management System › Strainer
Issued 21 October 2016
Resolved
Replace wasted bilge suction strainers as required throughout the vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 28 October 2016
Resolution: Completed, sighted replacement bilge suction strainers and lower piping protions in all spaces.
Fire Fighting › Combustible Materials › Insulation
Issued 21 October 2016
Resolved
Cover exposed high temperature areas on main engine exhausts to prevent contact eith combustible materials.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 November 2016
Resolved 28 October 2016
Resolution: Confirmed installation of protective covering over MDE exhausts.