Passenger (Inspected) · Passenger Ship class · Built 1950s · USCG Great Lakes District (CGD-GL) · Other hulls named HURON
HURON is a 1955 passenger vessel (inspected). The Coast Guard has recorded 111 inspections since 1985, most recently in January 2025, along with 117 deficiencies — 4 with no resolution recorded —, 1 operational control and 9 casualty investigations between 2009 and 2023.
Records from 1985 to 2025. Most recent: inspection, 13 January 2025.
- Built
- 1955
- Last inspected
- 13 January 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 111
- Deficiencies
- 117 recorded · 4 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 9 investigations · 2009–2023
Identity
269888
WDJ4199
43070
Flag
UNITED STATES
367775370
Maury page id
psix-43070
Inspections, by type
…with no type recorded12
…past their stated due date4
Years with a record
40 calendar years (1985–2025)
The 111 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)86.4 ft × 25.0 ft × 7.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPAASCH MARINE SERVICE · ERIE, PA, UNITED STATES · built 1955
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMACKINAC ISLAND, MI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
99 - Displacement, Ton
67 - Regulatory (Subpart C or D), Net Ton
99 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ4199MMSI 367775370 · active · compulsorily equipped · granted 2 March 2017, expires 2 March 2027
WDI5216MMSI 367706310 · expired · compulsorily equipped · granted 10 December 2015, cancelled 7 March 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 111
13 January 2025
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8062801
9 September 2024
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7999054
23 May 2024
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7947889
29 January 2024
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7857715
18 December 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7840217
2 October 2023
Inclining Experiment
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7801962
21 September 2023
Deficiency Check · Examination of Repairs · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7813789
10 July 2023
MTSA Verification · Administrative Inspection · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7742605
6 March 2023
Examination of Repairs · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7646543
6 March 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7647579
3 March 2023
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7645140
3 March 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7646843
12 January 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7620526
5 January 2023
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7617485
20 December 2022
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7625741
9 December 2022
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7606942
9 December 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7610802
17 November 2022
In-Service Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7596199
17 November 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7596707
17 August 2022
In-Service Inspection · Examination of Repairs · Administrative Inspection · Damage Survey · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7564218
25 May 2022
COI Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7437397
8 April 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7427370
6 April 2022
In-Service Inspection · Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7425482
20 December 2021
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7370850
14 July 2021
Examination of Repairs · Damage Survey · Deficiency Check · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7345160
1 June 2021
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7221120
2 November 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7088254
24 September 2020
Annual Inspection · In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7063790
11 March 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6925108
13 February 2020
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6908657
1 November 2019
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6849036
9 October 2019
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6831645
1 August 2019
Hull Examination · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6789617
23 April 2019
Liferaft Servicing
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6703312
9 April 2019
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6658876
9 April 2019
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6665453
31 October 2018
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6573461
25 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6548247
18 June 2018
Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6473967
13 February 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6354336
5 February 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6353934
25 January 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6353861
8 January 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6336351
14 December 2017
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6322116
26 October 2017
Administrative Inspection · Damage Survey · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6297418
11 October 2017
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6285259
25 September 2017
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6274813
11 June 2017
Administrative Inspection · Deficiency Check · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6173693
16 December 2016
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6059084
28 October 2016
In-Service Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6034499
21 October 2016
Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6026920
10 June 2016
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5923291
8 June 2016
Hull Examination · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5902364
6 April 2016
Plan Review (Other than "T") · Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5931586
15 December 2015
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5783638
5 November 2015
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5758547
5 June 2014
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4880032
26 March 2014
Deficiency Check · In-Service Inspection · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4918997
27 February 2012
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4251748
5 August 2011
Examination of Repairs · Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4111217
5 August 2011
Damage Survey · Drydock Exam
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4119195
3 August 2011
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 4111384
29 September 2010
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3860521
2 April 2009
Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3445092
31 March 2009
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3446575
7 October 2008
MTSA Verification · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3340328
19 September 2007
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3061167
14 September 2007
Annual Inspection · MTSA Verification
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 3057580
21 August 2006
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2755213
7 June 2006
Hull Examination
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2675008
24 August 2005
COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2471431
21 July 2005
Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2447647
2 June 2005
MTSA Verification
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2376733
30 August 2004
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 2181422
23 December 2003
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978176
18 September 2003
Periodic Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1910883
9 October 2002
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1689953
15 November 2001
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1460588
20 July 2001
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1433870
22 February 2001
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1059613
4 October 2000
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1369886
12 October 1999
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1399198
10 November 1998
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 805380
4 November 1998
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1436136
17 February 1998
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 776750
21 October 1997
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 778429
29 September 1997
Re-Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1378179
10 December 1996
Administrative
Administrative · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1091212
4 November 1996
Deficiency Check
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1168244
4 October 1996
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 842254
26 July 1996
Hull Examination
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1087933
5 October 1995
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1183286
28 March 1995
Type not recorded
No type recorded · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 109168
5 October 1994
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 1178537
26 October 1993
COI Inspection
Physical examination · MSO SAULT STE MARIE · USCG Great Lakes District (CGD-GL) · Activity 836626
6 October 1992
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 934949
30 October 1991
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 940801
10 September 1991
Hull Examination
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 933214
4 April 1991
Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 918060
29 March 1991
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1213460
22 May 1990
Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 901909
6 April 1990
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1209389
10 April 1989
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1196561
5 April 1988
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1034875
5 May 1987
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1335937
31 October 1986
Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1307001
8 September 1986
Credit Drydock
Administrative · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1023747
6 August 1986
Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1304848
13 June 1986
Deficiency Check
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1302507
8 April 1986
COI Inspection
Physical examination · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 1307183
9 April 1985
Type not recorded
No type recorded · MIO ST. IGNACE · USCG Great Lakes District (CGD-GL) · Activity 981854
Deficiency record · 117
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 23 May 2024
No resolution recorded
port side engineroom vents are damaged & should be repaired or replaced; wastage sighted at both ladderwell windows; forward draft marks are not correct; vessel does not have loading marks, confirm whether required or not, properly apply if required.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 23 May 2024
No resolution recorded
Pilothouse MDE oil pressure gauge inoperative/erratic & unreliable, must be corrected
Pilothouse MDE emergency stop inoperative, must be corrected
Pilothouse MDE alarm panel inoperative, must be corrected
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 May 2024
No resolution recorded
MDE emergency fuel shut-off mechanism needs to be adjusted or modified to ensure complete closure and reliability
** corrected but still needs additional routing to be considered permanently repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2024
Resolved
Port side genset inoperative due to faulty starter. Company is awaiting replacement part. Complete repairs and demonstrate proper operation to attending CG Marine Inspector. Vessel must be provided with and maintain battery back-up power for vital systems until second genset is repaired & operational.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 29 January 2024
Resolved
Crew is unable to provide accurate documentation/attestation to the amount of cargo/baggage that is carried. This is in direct contradiction to the vessels issued stability letter. The carriage of passengers and cargo/baggage combinations is not authorized until accurate weight calculations can be obtained for the vessels crew/shore-side facility personnel and presentable to the OCMI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 18 December 2023
Resolved
1 pilothouse window is cracked and must be replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2023
Resolved
All dead-end wiring must be properly terminated &/or removed. Any new wiring installations must be properly approved prior to installation.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 18 December 2023
Resolved
Vessels engine room has accumulation of oil on the machinery and oil/trash on deck plates and in the bilges, all must be properly cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 October 2023
No resolution recorded
Auxiliary heating boiler has been installed by reputable vendor with Marine Inspector oversight, however submitted installation plans & equipment list have yet to be approved by the MSC. Until approval is granted, installation confirmed to be in compliance with these approved plans (to include an emergency fuel shut-off valve), hydrostatic test & operational testing of all the installed safety devices are witnessed by CG MI, operating the boiler is prohibited.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 July 2023
Resolved
Maindeck overhead sprinkler system diffuser heads must be standardized, both relating to type and position.
Correct prior to "winter season" operations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2023
Resolved
Pilothouse emergency comms battery requires proper cover.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 July 2023
Resolved
Gensets do not have emergency fuel shut-offs. Install & demonstrate proper operation.
Correct prior to "winter season" operations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 July 2023
Resolved
Cover missing from electrical J-box under stbd side of helm. Replace.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 10 July 2023
Resolved
Several wasted areas sighted at maindeck forward area outboard by loading doors.
Correct prior to "winter season" operations.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 March 2023
Resolved
While underway carrying passengers en route to Mackinac Island, Captain reported feeling a resistance in the steering system. Upon investigation deckhands found the forward-most chain knuckle in the steering shaft to be cracked. This is the second time in three days the steering had bound up and caused this same knuckle to crack under heavy torsion. Upon inspection, MI found that the steering shaft had shifted approximately 1/4 to 3/8's of an inch at numerous spots along the joints and unions. As well as the key had rolled in the key-way at the section where the shaft reduces from 1 1/2 down to 1 inch.
Submit repair proposal to this office for approval in correcting failures occurring in the steering system and, once approved, affect repairs to the satisfaction of the attending Coast Guard Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 January 2023
Resolved
Mechanics found flattened cam lobe on MDE. Effect repairs and confirm safe operation via underway trials with Coast Guard Marine Inspectors.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 21 November 2022
Resolved
Locally fabricated steering gear pillow block/bearing must be replaced with a properly manufactured and system appropriate pillow block/bearing.
Installation and operational testing must be witnessed by attending CG Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 October 2022
Resolved
Replace rejected (burst) maindeck fire hose.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 25 May 2022
Resolved
Sighted many areas of concern relating to corrosion/wastage. Areas included: lazarrette, stairs to 2nd deck, port side mooring bits, holding tank compartment, accommodation space outer edges, pilothouse landing and deck, along with port qtr damage.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 25 May 2022
Resolved
Engineroom – sighted MDE oil leak, MDE exhaust leak, throttle/transmission linkage needs to be professionally assembled with proper hardware.
Oil leak on genset at dipstick requires repair/replacement.
Transmission oil temp alarm constantly on in pilothouse, sensor/transducer on order.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 May 2022
Resolved
Found 1-50 person IBA servicing expired April 2022.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 25 May 2022
Resolved
Found all 4 IBAs painter lines not properly secured. Instructed crew how to properly install & regularly inspect.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 6 April 2022
Resolved
Vessel experienced a loss of steering while transiting between Mackinac Island and St. Ignace, MI. The cause appears to be damage sustained to the rudder by ice.
Assess damage, submit repair proposal to OCMI, repair IAW approved plan, demonstrate proper operation prior to carriage of passengers.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 June 2021
Resolved
Vessels 4-50 person permanent IBAs servicing has expired; IBAs must be sent out for annual servicing.
Vessel is not authorized carriage of passengers until IBAs are serviced or replaced & the OCMI is notified.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 1 June 2021
Resolved
Make vessel available for underway operational testing, demonstrate emergency drills. All to be witnessed by CG Marine Inspectors.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 September 2020
Resolved
Clean and descale port side sewage void and schedule CG Marine Inspector to attend and inspect.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 September 2020
Resolved
Fire extinguisher bracket is loose on the deck in engine room. Secure fire extinguisher bracket.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 September 2020
Resolved
Label GENSET with de-rating placard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2020
Resolved
Remove extension cords from under the port bridge console, passenger cabin, and aft life jacket storage. They have been there for some time and are no longer temporary.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 24 September 2020
Resolved
Flange on fire main pump is leaking. Effect repairs to make pump not leak into engine room.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 February 2020
Resolved
Secure/ remove exposed wiring in the forepeak overhead.
46 CFR 183.01-5
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 1 November 2019
Resolved
Vessels 4-50 person permanent IBAs have been sent out for annual servicing. Replacement IBAs total capacity is 160 persons (2-50 person & 2-30 person). Vessel is limited to 320 total persons allowed until permanent IBAs are re-installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2019
Resolved
A quarter sized crack is present on the stbd side, 6 inches from the keel, in the void aft of the forepeak. Submit repair proposal for approval and effect permanent repairs to hull plating to the satisfaction of the attending marine inspector prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 October 2018
Resolved
Bilge suction piping wasted, leak caused loss of suction, corrected during inspection.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018
Resolved
The vessel is currently broadcasting (1) Improper MMSI Number, (2) Improper Call Sign, (3) Improper Ship Type. Ship Type should be a two digit number (60) Per the US Official Encoding guide.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 18 June 2018
Resolved
Wastage identified in internal structural members. Areas identified to be cropped and renewed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 18 June 2018
Resolved
Hatch covers leak and need to be maintained or renewed.
Fire Fighting › Combustible Materials › Insulation
Issued 27 December 2017
Resolved
Provide oil resistant insulation to prevent combustible materials from coming into contact with hot surfaces of engine exhausts for main engine and ship service generators.
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 27 December 2017
Resolved
Discharge end of fuel tank vent piping shall be fitted with a removable flame screen made of corrosion resistant wire in at least 30 X 30 mesh.
Stability › Weathertight Integrity › General
Issued 27 December 2017
Resolved
Demonstrate proper operation of engineroom access door; must be weathertight and securing devices must work properly as per 46 CFR 116.1160.
Construction/Loadline › Hull › Transverse Frame
Issued 11 October 2017
Resolved
Determine extent of steel wastage in internal structures and hull plating in way of forepeak void and 1st void abaft the collision bulkhead, and complete permanent repairs to same, prior to operating in commercial service.
Personnel › Training › Cargo Safety
Issued 25 September 2017
Resolved
Complete appropriate hazardous material employee training prior to the carriage of hazardous materials.
Engineering › Steering Gear System › Linkage
Issued 11 June 2017
Resolved
Make permanent repairs to steering system and demonstrate proper operation of same to the satisfaction of the attending marine inspector.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 October 2016
Resolved
Post EAP policy and hotline information wither oin vessel or at crew time-clocks.
Stability › Freeing Ports › General
Issued 21 October 2016
Resolved
Permanently repair broken non-return flap on freeing port in way of port bulwark next to engineroom access.
Engineering › Fuel Oil Service System › Piping
Issued 21 October 2016
Resolved
Reconfigure fuel supply piping to aft ship service generator to eliminate risk of damage.
Engineering › Bilge Water Management System › Strainer
Issued 21 October 2016
Resolved
Replace wasted bilge suction strainers as required throughout the vessel.
Fire Fighting › Combustible Materials › Insulation
Issued 21 October 2016
Resolved
Cover exposed high temperature areas on main engine exhausts to prevent contact eith combustible materials.
Fire Fighting › Combustible Materials › Insulation
Issued 5 November 2015
Resolved
Provide oil resistant insulation on exposed high temperature areas of main engine exhausts as to prevent contact with combustible materials.
Lifesaving › Lifefloat › Serviceable
Issued 5 November 2015
Resolved
Life floats with deteriorated lines must be replaced or repaired, before operating after 31MARCH2016.
Electrical › Electric Supply System (service) › Cable
Issued 5 November 2015
Resolved
Provide permanently installed electrical circuit for Modine heater in engineroom.
Fire Fighting › Fire Hoses › Connections
Issued 5 November 2015
Resolved
Provide fire hoses and nozzles that have fully compatible threads. Meanwhile leave hoses and nozzles connected at all times.
Engineering › Pressure Vessel › Safety Valve
Issued 5 November 2015
Resolved
On the hot water heating boiler, relocate safety valve directly into boiler casing, and provide servicing report that documents testing and proper operation of all safefty devices and operating controls.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 November 2015
Resolved
Main fuel oil tank top severely wasted and epoxy coatings have not been maintained. Tank top was cleaned and new epoxy was applied to maintain remaining integrity until permanent repairs can be completed, related to outstanding requirement #10 issued 10/23/13 per Activity 4748242.
Construction/Loadline › Hull › Side Shell
Issued 14 September 2007
Resolved
Make permanent repairs/ weld 1" fracture in port quarter steering compartment just below rubrail.
Engineering › Steering Gear System › Bracket/Clamp
Issued 14 September 2007
Resolved
Replace missing quadrant nut on bracket.
Construction/Loadline › Hull › Hull Plating
Issued 22 August 2005
Resolved
Several fractured welds in the steering compartment on the outboard port side upper area. Renew welds or replace metal.
Fire Fighting › Fire Pumps › Pumpshaft
Issued 22 August 2005
Resolved
Repair leaking pump seal on main fire pump.
Stability › Watertight Integrity › General
Issued 30 August 2004
Resolved
Install a indicator light at the operating station showing whether the watertight door in the engineroom is open or closed.
Fire Fighting › Fire Pumps › Arrangement
Issued 18 September 2003
Resolved
Replace belt on engine driven fire pump.
Construction/Loadline › Penetrations › Gasket
Issued 18 September 2003
Resolved
Replace gasket on water tight door engine room.
Engineering › Steering Gear System › Linkage
Issued 18 September 2003
Resolved
Replace set screw on steering connection.
Construction/Loadline › Hull › Weld
Issued 18 September 2003
Resolved
Repair two weld fractures port side fwd void.
Construction/Loadline
Issued 15 November 2001
Resolved
Repair remote reach rod for forward bilge valve inside the forepeak prior to the compliance date.
Documentation
Issued 15 November 2001
Resolved
Provide copies of the latest service report for the hot water heater and the current certificate of documentation sticker prior to the compliance date.
Fire Fighting
Issued 15 November 2001
Resolved
Repair the cracked fire main shut off valve prior to operations and prior to the compliance date.
Fire Fighting
Issued 15 November 2001
Resolved
Replace the damaged 1.5 inch fire hose prior to operations and prior to thecompliance date.
Engineering
Issued 15 November 2001
Resolved
Replace the fuel oil return line (non-metalic flex-hose section) for the # 2 generator prior to the compliance date.
Construction/Loadline
Issued 15 November 2001
Resolved
Label watertight door in engine room "Watertight door-keep closed" in 4 inch letters, and repair the gasket, prior to the compliance date.
Accommodation/Occupational Safety
Issued 15 November 2001
Resolved
Label engine room emergency escape hatch with "Emergency exit-keep clear" in 2 inch letters prior to the compliance date.
Navigation
Issued 15 November 2001
Resolved
Tighten and double nut the rudder post packing flange bolts prior to the compliance date.
Construction/Loadline
Issued 15 November 2001
Resolved
Install strainers in the bilge suction lines, both port and starboard sides, inside the fuel tank space prior to the compliance date.
Fire Fighting
Issued 4 October 2000
Resolved
PRIOR TO GETTING UNDERWAY REPAIR AND PROVE OPERATSION OF ENGINE-DRIVEN FIRE& BILGE PUMP, BEFORE THE COMPLIANCE DATE.
Fire Fighting
Issued 4 October 2000
Resolved
PRIOR TO CARRYING PASSENGERS, RENEW DEFECTIVE FIRE HOSE ON MAIN DECK FIRESTATION BEFORE THE COMPLIANCE DATE.
Lifesaving
Issued 4 October 2000
Resolved
3 ADULT SIZE PFD'S REJECTED, DETERIORATED, RENEWED DURING INSPECTION.
Lifesaving
Issued 12 October 1999
Resolved
FLOAT-LIGHT LANYARD TOO LONG ON RING-BUOY, CORRECTED DURING INSPECTION.
Electrical
Issued 12 October 1999
Resolved
BROKEN GLOBE ON EMERGENCY LIGHT, 2ND DCK LANDING, PORTSIDE. CORRECTED DURING INSPECTION.
Lifesaving
Issued 12 October 1999
Resolved
9 ADULT AND 1 CHILD PFD'S UNSAT, REPLACED DURING INSPECTION.
Engineering
Issued 12 October 1999
Resolved
REPAIR, HYDROSTATICALLY TEST AND PROVE OPERATION OF HEATING BOILER BEFORE PLACING IT IN SERVICE AND BEFORE THE COMPLIANCE DATE.
Fire Fighting
Issued 12 October 1999
Resolved
PROVIDE CREW TRAINING AND CONDUCT DRILLS FOR MANOVERBOARD AND FIRE BEFORE THE COMPLIANCE DATE.
Lifesaving
Issued 12 October 1999
Resolved
J-BAR DAVIT CONTROL LINES MISSING, CORRECTED DURING INSPECTION
Lifesaving
Issued 12 October 1999
Resolved
MAN-OVERBOARD LADDER/RECOVERY UNWORKABLE, RE-VAMPED DURING INSPECTION, SEE MINS.
Electrical
Issued 4 November 1998
Resolved
ELECTRICAL SHOCK HAZARDS IWO 220VAC MAIN POWER PANEL WHICH IS PRE-1958 AND EXEMPT FROM CURRENT SAFETY STANDARDS IN REGULATION. DANGER SIGN REQUIRED ASALTERNATIVE PRECAUTION. CORRECTED DURING INSPECTION.
Electrical
Issued 4 November 1998
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF BOTH SHIP SERVICE ELECTRICAL GENERATORS BEFORE CARRYING PASSENGERS AND BEFORE THE COMPLIANCE DATE.
Engineering
Issued 4 November 1998
Resolved
LABEL FUEL OIL SHUTOFF VALVE AS PER 46 CFR 185.608 BEFORE THE COMPLIANCE DATE.
Construction/Loadline
Issued 4 November 1998
Resolved
BILGE PUMP FUNCTIONED BUT COULD NOT DRAW SUCTION FROM VARIOUS COMPARTMENTS,DUE TO AIR LEAKS IN SUCTION PIPING. CORRECTED DURING INSPECTION.
Electrical
Issued 4 November 1998
Resolved
EMERGENCY LIGHTS IN WAY OF PASSENGER EGRESS ROUTES INOPERABLE, CORRECTED DURING INSPECTION.
Electrical
Issued 4 November 1998
Resolved
VARIOUS LIGHTING FIXTURES, GLOBES AND GUARDS IN PASSENGER AND CREW AREAS BROKEN OR MISSING, BROKEN-EXPOSED LIGHT BULBS IN SEVERAL LOCATIONS, SHOCK HAZARDS, CORRECTED DURING INSPECTION.
Accommodation/Occupational Safety
Issued 4 November 1998
Resolved
ALL TOILETS SPACES EXCESSIVELY SOILED AND INOPERABLE, CORRECTED DURING INSPECTION.
Lifesaving
Issued 4 November 1998
Resolved
LIFE PRESERVERS WERE STOWED IN EXTERIOR BOXES WHICH WERE DIFFICULT TO OPEN AND WERE MOT PROPERLY MARKED. CORRECTED DURING INSPECTION.
Engineering
Issued 4 November 1998
Resolved
PRESSURE GAGE ON PORT AIR RECEIVER BROKEN, RENEWED DURING INSPECTION.
Engineering
Issued 4 November 1998
Resolved
EXCESSIVE OIL LEAKS AT REDUCTION GEAR, CORRECTED DURING INSPECTION, REPLACED BAD O-RINGS.
Engineering
Issued 4 November 1998
Resolved
HIGH PRESSURE HYDRAULIC OIL HOSES ON REDUCTION GEAR BADLY WORN AND WEAKENED, RENEWED DURING INSPECTION.
Electrical
Issued 4 November 1998
Resolved
EMERGENCY POWER BATTERY CONNECTIONS CORRODED AND LOOSE, CORRECTED DURING INSPECTION.
Lifesaving
Issued 4 November 1998
Resolved
RING-BUOY LIFELINE EXCESSIVELY WEATHERED, CORRECTED DURING INSPECTION
Navigation
Issued 4 November 1998
Resolved
RADIO EMERGENCY BROADCAST INSTRUCTIONS NOT AVAILABLE, POSTED DURING INSPECTION.
Construction/Loadline
Issued 4 November 1998
Resolved
REMOVE OILY WASTE AND DEBRIS FROM ENGINEROOM BILGE BEFORE THE COMPLIANCE DATE.
Lifesaving
Issued 29 September 1997
Resolved
Carry no passengers prior to correcting discrepancies on attached worklist,no later than 29NOV97.
Engineering
Issued 4 October 1996
Resolved
Install a pilot house propulsion engine shut down switch, in accordance with 46 CFR 184.620(b).
Lifesaving
Issued 4 October 1996
Resolved
Carry no more than 337 persons until 17 additional adult PFD's are provided.
Lifesaving
Issued 4 October 1996
Resolved
Install retro-reflective tape and stencil marked ring buoys, buoyant apparatus, and the rescue boat.
Fire Fighting
Issued 4 October 1996
Resolved
Replace portable nitrogen fire extinguisher on the bridge with an approved halon, CO2, or dry chemical extinguisher.
Fire Fighting
Issued 29 March 1991
Resolved
Replace portable fire/bilge pump.
Engineering
Issued 29 March 1991
Resolved
Repair deteriorated engine exhaust stack.
Construction/Loadline
Issued 29 March 1991
Resolved
Remove excess oil from engine room bilges._x001C_ _x001C_ _x001C_ _x001C_
Lifesaving
Issued 29 March 1991
Resolved
Replace carbide type life float lights with approved electric lights._x001C_
Lifesaving
Issued 29 March 1991
Resolved
Replace bow and stern lines on rescue boat.
Lifesaving
Issued 29 March 1991
Resolved
Provide 19 additional adult PFD's.
Accommodation/Occupational Safety
Issued 29 March 1991
Resolved
Repair seats, second deck.
Fire Fighting
Issued 6 April 1990
Resolved
PRIOR TO CARRIAGE OF HAZARDOUS CARGO, DEMONSTRATE OPERATION OF MAIN DECK WATER SPRINKLER SYSTEM.
Electrical
Issued 8 April 1986
Resolved
PROVIDE COVERS FOR BATTERY BOXES.
Engineering
Issued 8 April 1986
Resolved
RENEW FUEL TANK VENT SCREENS.
Engineering
Issued 8 April 1986
Resolved
REPLACE RELIEF VALVE ON PORT A/R.
Construction/Loadline
Issued 8 April 1986
Resolved
PERMANENTLY CLOSE OPENING IN BLKHD BETWEEN NOS. 5&6 VOIDS AND PROVIDE ACCES THROUGH MAIN DECK TO NO.6 COMPARTMENT FITTED WITH SUITABLE HATCH COVER.
Engineering
Issued 8 April 1986
Resolved
PROVIDE STRAINERS ON BILGE SUCTIONS IN FOREPEAK & NO. 6 VOID.
Deck/Cargo
Issued 9 April 1985
Resolved
PROVIDE 30X30 MESH FLAME SCREEN ON FUEL OIL VENT.
Accommodation/Occupational Safety
Issued 9 April 1985
Resolved
PROVIDE WATER SERVICE TO SINKS IN HEADS
Casualty record · 9
31 March 2009Routine · role: Involved in a Marine Casualty · activity 3446575
17 April 2013Routine · role: Involved in a Marine Casualty · activity 4571026
9 April 2019Routine · role: Involved in a Marine Casualty · activity 6665453
8 April 2022Routine · role: Involved in a Marine Casualty · activity 7427370
17 November 2022Routine · role: Involved in a Marine Casualty · activity 7596707
9 December 2022Routine · role: Involved in a Marine Casualty · activity 7610802
12 January 2023Routine · role: Involved in a Marine Casualty · activity 7620526
3 March 2023Routine · role: Involved in a Marine Casualty · activity 7646843
6 March 2023Routine · role: Involved in a Marine Casualty · activity 7647579
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.