MAURY USCG vessel records
← All vessels

ALLISON CREEK

ALLISON CREEK is a 1955 oil recovery. The Coast Guard has recorded 18 inspections since 2016, most recently in September 2023, along with 22 deficiencies.

Records from 2016 to 2023. Most recent: inspection, 27 September 2023.

Built
1955
Last inspected
27 September 2023
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 September 2023
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCR5709
Flag
UNITED STATES
Maury page id
psix-43075

Documentation record

Registered dimensions (L × B × D)200.8 ft × 42.0 ft × 16.0 ft
Registered tonnagegross 1,028 / net 1,028
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNASHVILLE, TN, UNITED STATES · built 1955
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portVALDEZ, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 November 2025 · expires 30 November 2026
Service, as the file records itOil Recovery
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1028 - Regulatory (Subpart C or D), Gross Ton
1028 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

27 September 2023 Load Line/Change of Employment · Administrative Inspection
Administrative · Detached Duty Office Seward · USCG Arctic District (CGD-A) · Activity 7827590
14 February 2022 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7396357
31 January 2022 In-Service Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7389300
13 August 2021 Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7286213
26 May 2021 Construction Oversight
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7212648
7 May 2021 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7191984
10 August 2020 Damage Survey
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7029073
1 July 2020 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 7025173
29 March 2019 Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6652241
21 June 2018 Administrative Inspection
Administrative · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6451687
8 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6412183
11 May 2017 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6148815
10 April 2017 COI Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6121706
13 March 2017 Examination of Repairs · Drydock Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6114743
26 January 2017 Examination of Repairs
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6078748
23 January 2017 Internal Structural Exam
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 6075290
25 April 2016 Deficiency Check
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5862349
2 March 2016 Annual Inspection
Physical examination · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 5825778

Deficiency record · 22

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 14 August 2021 Resolved
Provide repair proposal of vessels broken 8” cargo pipe IWO tanks 3 and 4 prior to conducting repairs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 August 2021
Resolved 18 August 2021
Resolution: Failed piping segment replaced to satisfaction of the Coast Guard.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 March 2019 Resolved
Provide gauging report of port bow area, in vicinity of the hole found on 3/29/2019 to [name withheld] must extend outwards from hole in a 2 foot radius. 46 CFR 8.110
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2019
Resolved 31 March 2019
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 29 March 2019 Resolved
Provide repair proposal prior to cropping for damage discovered in bow area on 3/29/2019. Should further damage or corrosion in need of repair in the bow area be noted in the gauging report referenced, ensure repair proposal addresses repair of that as well. 46 CFR 8.110
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2019
Resolved 31 March 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 March 2019 Resolved
Drill stop crack in port frame #3. 46 CFR 8.110
Action required: 17 - Rectify deficiencies prior to departure
Due 29 March 2019
Resolved 31 March 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 March 2019 Resolved
Permanently repair crack in frame #3 at next ddx. 46 CFR 8.110
Action required: 705 - Other - as specified
Due 29 March 2019
Resolved 31 March 2019
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 29 March 2019 Resolved
Repair cracked welds in way of port frame #5 and bottom shell at next drydock. 46 CFR 8.110
Action required: 705 - Other - as specified
Due 31 March 2022
Resolved 27 August 2025
Resolution: Vessel is no longer in Active Status.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 March 2019 Resolved
Gauge hull from inside in way of fenders at next ddx. 46 CFR 8.110
Action required: 705 - Other - as specified
Due 31 March 2022
Resolved 27 August 2025
Resolution: Vessel is no longer in Active Status.
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 13 April 2017 Resolved
Repair/replace holed generator exhaust
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2017
Resolved 11 May 2017
Construction/Loadline › Hull › Weld
Issued 23 January 2017 Resolved
Repair cracked weld aft rake port 3rd side long IWO of tank. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 27 March 2017
Resolution: Properly repaired crack weld
Construction/Loadline › Hull › Bracket
Issued 23 January 2017 Resolved
Crop and renew wasted bracket in aft rake below port 3rd side long. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 28 March 2017
Resolved 27 March 2017
Resolution: Bracket was properly repaired
Construction/Loadline › Hull › Weld
Issued 23 January 2017 Resolved
Repair failed weld in bracket in aft rake below port 3rd side long. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 27 March 2017
Resolution: Bracket was properly repaired.
Construction/Loadline › Hull › Stringer
Issued 23 January 2017 Resolved
In fwd rake, crop and renew to good metal wasted stringers (approx bottom 2 feet)port and stb of centerline. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 27 March 2017
Resolution: Bottom longs were cropped out and renewed
Construction/Loadline › Hull › Transverse Frame
Issued 23 January 2017 Resolved
Crop and renew cracked frame and bent bracket at port side frame 36 IWO centerline. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 27 March 2017
Resolution: Frame #36 was properly repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 23 January 2017 Resolved
Crop and renew fractured in frame 47 under tank bottom IWO side shell. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 27 March 2017
Resolution: Frame was properly repaired.
Construction/Loadline › Hull › Weld
Issued 23 January 2017 Resolved
Repair cracked welds in port side 3rd frame IWO centerline. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 27 March 2017
Resolution: Crack welds were properly repaired.
Construction/Loadline › Hull › Weld
Issued 23 January 2017 Resolved
Repair cracked weld in port side 6th frame IWO side shell. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 27 March 2017
Resolution: Crack welds were properly repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 23 January 2017 Resolved
Crop and renew cracked stb frame 1 IWO bottom plate 6 feet from side shell. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 27 March 2017
Resolution: Frame was properly repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 23 January 2017 Resolved
Crop and renew cracked stb frame 4 IWO bottom plate 6 feet from side shell. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 27 March 2017
Resolution: Frame was properly repaired.
Construction/Loadline › Hull › Hull Plating
Issued 23 January 2017 Resolved
Crop and renew to good metal wasted tank top in port #4 tank. Do not use tank until permanent repair completed. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 24 February 2017
Construction/Loadline › Hull › Hull Plating
Issued 23 January 2017 Resolved
Crop and renew to good metal wasted tank top in stb #4 tank. Do not use tank until permanent repair completed. All repairs to be completed prior to completing next credit dry dock.
Action required: 705 - Other - as specified
Due 22 March 2017
Resolved 24 February 2017
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 12 April 2016 Resolved
Install circuit breaker blank
Condition: Improper/Lack of Maintenance
Due 26 April 2016
Resolved 25 April 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 April 2016 Resolved
Install guard on the hydraulic prime mover
Condition: Improper/Lack of Maintenance
Due 26 April 2016
Resolved 25 April 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.