MAURY USCG vessel records
← All vessels

EXPLORER 9

EXPLORER 9 is a 1995 passenger vessel (inspected). The Coast Guard has recorded 4 inspections since 2016, most recently in January 2019, along with 7 deficiencies.

Records from 2016 to 2019. Most recent: inspection, 22 January 2019.

Built
1995
Last inspected
22 January 2019
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

430762
Flag
UNITED STATES
Maury page id
psix-430762

Inspections, by type

Years with a record 4 calendar years (2016–2019)
The 4 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 7 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 4

22 January 2019 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6613599
20 June 2018 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6450781
13 April 2017 DAPI Audit · COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6103821
14 March 2016 Annual Inspection · Examination of Repairs · Drydock Exam · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5832609

Deficiency record · 7

Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 June 2018 Resolved
The owner or managing operator shall make the vessel available for Drydock examination as require by this section. Vessel's Drydock credit has lapsed. Vessel must complete satisfactory Drydock prior to carriage of passengers. - 46CFR176.600(a) - 17c
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: Vessel has been placed out of service.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 April 2017 Resolved
EMERGENCY INSTRUCTIONS NOT POSTED, POST EMERGENCY INSTRUCTIONS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 185.512
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 19 April 2017
Resolution: EMERGENCY INSTRUCTIONS POSTED, DEFICIENCY CORRECTED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 13 April 2017 Resolved
LIFEJACKETS STOWAGE MARKING MISSING, LABLE STOWAGE LIFEJACKETS LOCATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 180.78
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 19 April 2017
Resolution: LIFEJACKETS STOWAGE MARKING DEFICIENCY CORRECTED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 April 2017 Resolved
LIFEBUOY LINE IS NOT APROPIATE TYPE, REPLACE IT WITH APROPIATE TYPE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 180.70
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 19 April 2017
Resolution: LIFEBUOY LINE REPLACED WITH APROPIATE TYPE, DEFICIENCY CORRECTED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 April 2017 Resolved
BATTERY MISSING APROPIATE NUTS TYPE, REPLACE THEM WITH APROPIATE TYPE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. 46 CFR 183.350
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 13 April 2017
Resolution: PROPERLY ISTALLED AND TYPE, CORRECTED ON THE SPOT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Engineering › Gasoline Engine (propulsion) › Gasoline Fuel Tank Ventilation
Issued 15 March 2016 Resolved
Fuel Tank vent hose was dry rotted. 46CFR177
Action required: 705 - Other - as specified
Due 15 April 2016
Resolved 25 March 2016
Construction/Loadline › Hull › Weld
Issued 15 March 2016 Resolved
Vessel had 11 cracked welds. 3 at stern( 2 on port tube and 1 on STBD tube where deck is attached to tubes), 2 on STBD hand rail station at deck, 5 under fwd deck, 1 on port fwd station. 46CFR177
Due 15 April 2016
Resolved 30 March 2016
Resolution: Owner repaired all cracks.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.