MAURY USCG vessel records Sign in
← All vessels

SWAMP RUNNER

SWAMP RUNNER is a 1995 passenger vessel (inspected). The Coast Guard has recorded 29 inspections since 1995, most recently in December 2024, along with 5 deficiencies.

Records from 1995 to 2024. Most recent: inspection, 17 December 2024.

Built
1995
Last inspected
17 December 2024
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

430837
Flag
UNITED STATES
—
Maury page id
psix-430837

Inspections, by type

…with no type recorded1
Years with a record 22 calendar years (1995–2024)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)28.0 ft × 12.7 ft × 2.5 ft
Registered tonnagegross 7 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMILTON R WALKER SR · GONZALES, LA, UNITED STATES · built 1995
Hull materialAluminum
PropulsionGasoline Engine
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 13 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Simplified, Gross Ton
5 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 29

17 December 2024 Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8048572
6 August 2024 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7949810
26 June 2023 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7723591
18 July 2022 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7485134
4 October 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7297178
2 June 2020 COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6957763
24 January 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6885620
9 July 2019 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6731999
14 June 2018 Annual Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6444417
26 June 2017 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6186879
29 June 2016 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5921060
18 June 2014 Administrative Inspection · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4892045
6 July 2012 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4364423
11 August 2005 Hull Examination
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2458242
17 June 2005 Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 2393370
1 July 2004 Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 2117026
10 June 2003 Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1813669
13 May 2002 Annual Inspection
Physical examination · MIDET WEST DETAIL · USCG Heartland District (CGD-H) · Activity 1616039
27 September 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1074475
19 March 2001 COI Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1465014
24 August 2000 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 822454
31 May 2000 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 820542
7 April 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1421841
23 March 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1411834
31 March 1998 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1468848
2 September 1997 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448952
23 September 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1392535
27 November 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464607
20 September 1995 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1435670

Deficiency record · 5

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 10 July 2023 Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a). Bilge pump float switch in aft compartment was found inoperable, preventing dewatering. Repair or renew.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2023
Resolution: Conducted necessary repairs and proved proper operations of the pump.
Lifesaving › Buoyant Apparatus
Issued 13 May 2002 Resolved
Provide 5/16 inch uv resistant polypropylene line for ring buoy. LEGACY COMPONENT DESC: Attched line
Condition: Improper Installation
Due 13 May 2002
Resolved 13 May 2002
Accommodation/Occupational Safety
Issued 19 March 2001 Resolved
IAW 46CFR 177.900, install bars, slats, rail courses or an "equivalent" spaced at intervals of not more that 4" apart.
Condition: Unknown
Due 19 March 2001
Resolved 19 March 2001
Documentation
Issued 20 September 1995 Resolved
PROVIDE SATISFACTORY DOCUMENTATION THAT THE MARINE EMPLOYER HAS AN ESTABLISHED CHEMICAL TESTING PROGRAM (DRUG & ALCOHOL) AS IDENTIFIED IN 46 CFR PART 16.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995
Documentation
Issued 20 September 1995 Resolved
POST OR PLACE ON BOARD THE VESSEL THE STABILITY LETTER ISSUED TO THIS VESSEL.
Condition: Unknown
Due 20 September 1995
Resolved 20 September 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.