MAURY USCG vessel records Sign in
← All vessels

PAMPERO

PAMPERO is a 1995 freight ship. The Coast Guard has recorded 28 inspections since 1995, most recently in July 2006, along with 15 deficiencies and 5 operational controls.

Records from 1995 to 2006. Most recent: inspection, 25 July 2006.

Built
1995
Last inspected
25 July 2006
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9113628 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
430898
Flag
GERMANY
—
Maury page id
psix-430898

Inspections, by type

…with no type recorded18
Years with a record 11 calendar years (1995–2006)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 20 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it5660 - Dead Weight, Metric Ton
7984 - Displacement, Metric Ton
2447 - Convention (Subpart B), Net Ton
2447 - Regulatory (Subpart C or D), Net Ton
4628 - Convention (Subpart B), Gross Ton
4628 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 28

25 July 2006 ISPS II Exam · PII Safety Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2724021
24 July 2006 Type not recorded
No type recorded · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2723508
14 October 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2514632
29 September 2005 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2507428
13 September 2005 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2496195
13 April 2005 PII Safety Exam · Ballast Water Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2333389
14 October 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2221086
5 August 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2157247
5 August 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2161928
11 March 2004 Annual Inspection · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2022513
26 January 2004 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1992715
24 October 2003 Re-Inspection · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1935747
14 April 2003 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1773262
6 March 2003 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1753479
25 February 2003 Ballast Water Examination · Annual Inspection · MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1747783
4 May 2002 MARPOL Annex I Examination · Annual Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1610428
4 October 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 283377
24 September 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 433021
4 February 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 425194
8 December 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 423440
30 May 1998 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 416538
29 November 1997 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 410325
2 August 1997 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 406428
18 February 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 400664
4 January 1997 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 398970
26 October 1996 Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 396746
3 April 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 389729
29 September 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 383465

Deficiency record · 15

Engineering › Steering Gear System › Ram
Issued 14 October 2005 Resolved
Starboard hydraulic ram developed a leak at the rod seals. A new ram was delivered as spare parts were intstalled by ships crew and workshop. The steering system was inspected visually and operated satisfactorily.
Condition: Unknown
Action required: 705 - Other - as specified
Due 14 October 2005
Resolved 14 October 2005
Resolution: Received class report, cleared deficiency.
Engineering › Steering Gear System
Issued 11 March 2004 Resolved
Vessel's #2 steering gear pump failed during steering gear test. Vsl to remain in port until Class/Flag survey the vessel and provide a written report attesting to proper repairs and sat operation. LEGACY COMPONENT DESC: Pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2004
Resolution: After careful observation of testing of steering system, all is satisfactory. Vessel cleared to depart. Result of incident were ruptured O-rings, O-ring were replaced and operated properly when system was tested.
Navigation › Piloting/Steering
Issued 11 March 2004 Resolved
Vessel to obtain copy of US Coast Pilot or equivalent. Vessel to send Master's statement attesting to the possession of acquired publication. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2004
Resolution: Recieved fax from master of vessel stating the purchase of the proper navigational publications.
Navigation › Piloting/Steering
Issued 11 March 2004 Resolved
Repair/ replace Gyrocompass repeater for steering gear room in 30 days or prior to entering next US port. Send invoice to cognizant OCMI of proper receipt and installation. LEGACY COMPONENT DESC: Gryo Compass Repeater
Condition: Damaged By Earlier Event
Action required: 15 - Rectify deficiencies by next port
Due 11 April 2004
Resolved 1 April 2004
Resolution: Recieved fax from vessel, recipet showing the purchase of a new repeater steering compass.
Electrical › Electric Generation Source (emergency)
Issued 24 October 2003 Resolved
To the satisfaction of Class, properly operate Emergency Generator with 2 means of starting. Solas 74 as amended II-1/44.2 LEGACY COMPONENT DESC: Generator
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 November 2003
Resolved 26 January 2004
Resolution: Attending MI verified to means of properly operating the Emergency Generator.
Fire Fighting › Fire Hoses
Issued 25 February 2003 Resolved
Vessel to remove from service 2 fire hoses found to be punctured during the fire drill. Vessel to inspect all fire hoses and replace all that are not fit for service. LEGACY COMPONENT DESC: Material
Condition: Unknown
Due 25 February 2003
Resolved 25 February 2003
Resolution: All punctured fire hoses replaced.
Accommodation/Occupational Safety › Occupational Safety
Issued 25 February 2003 Resolved
Accommodation passageways where found blocked by inappropriate stores.
Due 25 February 2003
Resolved 25 February 2003
Resolution: Items removed and properly stored during boarding.
Electrical › Lighting (service)
Issued 25 February 2003 Resolved
Class/Flag to survey electrical light fixture in the paint locker to determine if fixture is certified as a safe type in accordance with SOLAS 74 (amended). LEGACY COMPONENT DESC: Lighting Fixture
Due 25 March 2003
Resolved 14 April 2003
Resolution: Received via fax a statement from vessel master dated 10Apr03, stateting the correction of the deficiency issued on 25feb03 by SJPMS, activity number 1747783.
Accommodation/Occupational Safety › Occupational Safety
Issued 4 May 2002 Resolved
PROVIDE ADDITIONAL NON-SLIP MATERIALS IN THE STEERING GEAR ROOM.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 June 2002
Resolved 20 May 2002
Resolution: Received a fax reciept from ITAL MARINE located in Purto Cabello, VE indicating the vessel has purchased non-slip matting.
Documentation
Issued 8 December 1998 Resolved
Prior to returning to U.S. waters, include COFR applicant's name, address, and contact numbers in the SOPEP ship interest contacts.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Lifesaving
Issued 8 December 1998 Resolved
Prior to returning to U.S. waters, provide on board for review documentation from the "company" to the vessel's master containing policy and procedures for familiarization training for newly assigned crew.
Condition: Unknown
Due 4 February 1999
Resolved 4 February 1999
Navigation
Issued 26 October 1996 Resolved
PROVIDE WARNING FOR MANEUVERNG FACT SHEET._x001C_
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Documentation
Issued 26 October 1996 Resolved
PROVIDE PROPER NAME FOR PERSON IN CHARGE.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Documentation
Issued 26 October 1996 Resolved
PROVIDE PROPER NAME OF VESSEL ON ITC TONNAGE CERTIFICATE.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Documentation
Issued 29 September 1995 Resolved
PROVIDE ONBAORD VESSEL A COMPLETE SET OF OIL TRANSFER PROCEDURES IAW 33 CFR155.750 PRIOR TO NEXT US BUNKERING BUT NO LATER THAN 19OCT95.
Condition: Unknown
Due 6 October 1995
Resolved 6 October 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.