Records from 1985 to 2006. Most recent: inspection, 30 July 2006.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 38
30 July 2006
Administrative Inspection
Administrative · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2735815
28 July 2005
Annual Inspection
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 2447341
1 July 2004
Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 2119009
25 August 2003
Annual Inspection
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1880565
13 June 2002
COI Inspection · Simplified Stability Test · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 1671858
30 October 2001
Plan Review "T" Boat
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 772496
12 September 2001
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1072417
27 July 2001
Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1370306
2 August 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1360998
2 August 1999
Plan Review "T" Boat
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1378775
15 July 1998
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1472340
11 September 1997
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1409778
7 July 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1447773
21 May 1997
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1101829
16 January 1997
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1099581
22 April 1996
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1414631
5 September 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1192692
17 July 1995
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1182560
17 May 1995
Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1192949
11 July 1994
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 866746
22 April 1994
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1167822
28 March 1994
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 855513
18 March 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1166245
31 January 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 852162
17 December 1993
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 849256
30 August 1993
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 828692
12 July 1993
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1157548
2 July 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 844041
23 June 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1154354
2 July 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 954624
29 June 1992
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1265507
10 May 1989
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1346104
11 May 1988
COI Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1348108
20 April 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1042732
8 May 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1331402
6 May 1986
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1001078
30 April 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1307944
2 May 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 982858
Documentation › Certificates/Documents › FCC SSL
Issued 28 July 2005
No resolution recorded
Provide current FCC Communications Act Safety Radiotelephony Certificate
Action required: 705 - Other - as specified
Due 28 August 2005 — due date passed with no resolution recorded
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 July 2002
Resolved
MAKE PERM REPAIRS TO PORT ENGINE COOLING LINE (LEAKING) LEGACY COMPONENT DESC: HOSE
Condition: Unknown
Due 1 August 2002
Resolved 1 August 2002
Resolution: DONE
Lifesaving › Visual Distress Signals (General)
Issued 27 June 2002
Resolved
MOUNT EPRIB LEGACY COMPONENT DESC: EPRIB
Condition: Unknown
Due 1 August 2002
Resolved 1 August 2002
Lifesaving › Visual Distress Signals (General)
Issued 27 June 2002
Resolved
REGISTER EPRIB LEGACY COMPONENT DESC: EPRIB
Condition: Unknown
Due 1 August 2002
Resolved 1 August 2002
Resolution: DONE
Lifesaving › Buoyant Apparatus
Issued 27 June 2002
Resolved
MOUNT LIFE FLOATS, W/ VESSEL NAME AND PADDLES LEGACY COMPONENT DESC: LIFE FLOATS
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2002
Resolution: DONE
Lifesaving › Buoyant Apparatus
Issued 27 June 2002
Resolved
PROVIDE PROPERLY SIZED WEAK LINK TO LIFE FLOAT LEGACY COMPONENT DESC: WEAK LINNK TO L/F
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2002
Lifesaving › Lifejacket/PFD (General)
Issued 27 June 2002
Resolved
PROPERLY MARK PFD LOCKER LEGACY COMPONENT DESC: PFD LOCKER
Condition: Unknown
Due 1 August 2002
Resolved 3 July 2002
Lifesaving › Lifejacket/PFD (General)
Issued 27 June 2002
Resolved
PROPERLY MARK CHILD PFD LOCKER AND WITH NUMBER OF PFDs LEGACY COMPONENT DESC: CHILD PFD LOCKER
Condition: Unknown
Due 1 August 2002
Resolved 3 July 2002
Lifesaving › Lifejacket/PFD (General)
Issued 27 June 2002
Resolved
MARK ALL PFD WITH VESSEL'S NAME LEGACY COMPONENT DESC: MARK PFD
Condition: Unknown
Due 1 August 2002
Resolved 3 July 2002
Resolution: DONE (NOT ALL WERE MARKED)
Lifesaving › Lifebuoys
Issued 27 June 2002
Resolved
PROVIDE 60FT LINE TO RING BUOY LEGACY COMPONENT DESC: LINE TO RING BUOY
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2002
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 27 June 2002
Resolved
PROVE PROEPR OPERATION OF FIXED FIRE SYSTEM AND SHUT DOWN OF MDE LEGACY COMPONENT DESC: PROVE PROPER OPERATION
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2002
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 27 June 2002
Resolved
DOUBLE CLAMP BOTH ENG ROOM RAW WATER SUCTION LEGACY COMPONENT DESC: HOSE
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2002
Engineering › Bilge Water Management System
Issued 27 June 2002
Resolved
PROVE PROPER OPERATION OF FWD BILGE PUMP'S IN AUTOMATIC MODE (WITH INDICATOR) LEGACY COMPONENT DESC: BILGE PUMP
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2002
Engineering › Bilge Water Management System
Issued 27 June 2002
Resolved
PROVE PROPER OPERATION OF ENGINE ROOM HIGH LEVEL ALARM IN AUTO WITH A LIGHT LEGACY COMPONENT DESC: ENGINE ROOM BILGE ALARM
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2002
Engineering › Bilge Water Management System
Issued 27 June 2002
Resolved
PROVE PROPER OPERATION OPF STROAGE COMPT BILGE ALARM LIGHT IN AUTO MODE. LEGACY COMPONENT DESC: STORAGE COMP BILGE ALARM
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 27 June 2002
Resolved
PROVIDE FOR AN ADDITINAL COURSE IN RAILS LEGACY COMPONENT DESC: Deck Rail
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 July 2002
Fire Fighting › Fire Pumps
Issued 13 June 2002
Resolved
PROVIDE 3 FIRE BUCKETS WITH LANYARDS LEGACY COMPONENT DESC: FIRE BUCKETS
Condition: Unknown
Action required: 703 - Prior to bunkering operations
Resolved 3 July 2002
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 June 2002
Resolved
PROVIDE CLIP FOR RING BUOY'S LIGHT LANYARD
Condition: Unknown
Due 1 August 2002
Resolved 1 August 2002
Construction/Loadline › Hull › Stiffener
Issued 2 August 1999
Resolved
PEFORM CREDIT HULL EXAMINATION. PROVIDE CG APPROVED PLANS FOR ENTIRE HULL REFURBISHMENT/GUTTING AND EXTERIOR HULL REFASTENING, PLYWOOD AND FRP APPLICATION, MATERIALS LIST, ENGINE INFORMATION TO THE COGNIZANT [name withheld] TEST.
Condition: Unknown
Due 13 June 2002
Resolved 13 June 2002
Resolution: See Activity 1671858 13Jun05.
Construction/Loadline
Issued 7 July 1997
Resolved
RENEW 1 ROTTED PLANK AT THE SHEAR, STARBOARD SIDE JUST AFT OF BOW AND AFT 6'._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 September 1997
Resolved 7 January 1998
Unknown
Issued 7 July 1997
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 12 November 1997
Resolved 12 November 1997
Construction/Loadline
Issued 22 April 1996
Resolved
INSTALL ADEQUATE (NOT LESS THAN 383 SQ IN) OF SCUPPER DRAINAGE AND PRESENT FOR INSPECTION.
Condition: Unknown
Due 4 June 1996
Resolved 4 June 1996
Construction/Loadline
Issued 5 September 1995
Resolved
PROVIDE PROPOSAL FOR INSTALLING DECK DRAINAGE (FREEING PORTS) IN BULWARKS TO COMPLY WITH THE REQUIREMENTS OF 46CFR 171.150.
Condition: Unknown
Due 5 September 1995
Resolved 5 September 1995
Documentation
Issued 5 September 1995
Resolved
CONDUCT SIMPLIFIED STABILITY TEST IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 5 September 1995
Resolved 5 September 1995
Accommodation/Occupational Safety
Issued 17 July 1995
Resolved
REPAIR STAIR TREAD ON WEATHER DECK STAIR (LOWER) ON PORT SIDE.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Construction/Loadline
Issued 17 July 1995
Resolved
RENEW BLOCK COVERING UNUSED OVER BOARD ON THE PORT SIDE #3 COMPARTMENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Construction/Loadline
Issued 17 July 1995
Resolved
REPAIR UNDER DECK BEAM ON PORT SIDE OF COMPARTMENT #3.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Unknown
Issued 17 July 1995
Resolved
SUBMIT PROPOSAL FOR REPAIRS TO DETERIORATED CHINE BOARD ON THE PORT SIDE OF#3 COMPARTMENT AS DETAILED ON WORKLIST ITEMS 1,2,3 AND 4 ISSUED ON 11JUL95.
Condition: Unknown
Due 17 July 1995
Resolved 30 July 1995
Construction/Loadline
Issued 17 May 1995
Resolved
REPAIR DECK ON PORT SIDE FORWARD AS DISCUSSED DURING INSPECTION.
Condition: Unknown
Due 27 May 1995
Resolved 30 July 1995
Unknown
Issued 17 May 1995
Resolved
CONDUCT UNDERWAY TEST IN PRESENCE OF A CG MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 5 July 1995
Resolved 30 July 1995
Construction/Loadline
Issued 17 May 1995
Resolved
RENEW PLANK #17 STBD AND #32 PORT.
Condition: Unknown
Due 27 May 1995
Resolved 30 July 1995
Unknown
Issued 17 May 1995
Resolved
INSTALL VENTILATION IN THE #3 COMPARTMENT.
Condition: Unknown
Due 27 May 1995
Resolved 30 July 1995
Construction/Loadline
Issued 17 May 1995
Resolved
PULL ADDITIONAL BOTTOM FASTENING IN AREAS DESINATED DURING INSPECTION AND MAKE AVAILABLE FOR EXAMINATION.
Condition: Unknown
Due 17 May 1995
Resolved 30 July 1995
Construction/Loadline
Issued 17 May 1995
Resolved
REFASTEN TRANSVERSE TO VERTICAL FRAME CONNECTIONS IN #3 COMPT., ENGINE ROOMAND LAZARETTE.
Condition: Unknown
Due 27 May 1995
Resolved 30 July 1995
Construction/Loadline
Issued 18 March 1994
Resolved
PRIOR TO PLACING VESSEL IN SERVICE AND NO LATER THAN 10 APRIL 1994, MAKE VESSEL READY FOR UNDERWAY HULL EXAMINATION.
Condition: Unknown
Due 18 March 1994
Resolved 18 March 1994
Unknown
Issued 31 January 1994
Resolved
PRIOR TO PLACING VESSEL IN SERVICE AND NO LATER THAN 28 FEBRUARY 1994 MAKE VESSEL READY FOR DRYDOCK EXAMINATION.
Condition: Unknown
Due 31 January 1994
Resolved 31 January 1994
Lifesaving
Issued 23 June 1993
Resolved
PROVIDE ADEQUATE MEANS TO RECOVER PERSONS OVERBOARD.
Condition: Unknown
Due 23 June 1993
Resolved 23 June 1993
Lifesaving
Issued 10 May 1989
Resolved
REPLACE ONE ADULT TYPE I PFD.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Documentation
Issued 10 May 1989
Resolved
OBTAIN VALID FCC MARINE OPERATORS PERMIT.
Condition: Unknown
Due 10 May 1989
Resolved 10 May 1989
Engineering
Issued 11 May 1988
Resolved
PROVIDE INFROMATION AS TO CONSTRUCTION AND APPROVAL OF NEW FUEL TANKS.
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988
Lifesaving
Issued 11 May 1988
Resolved
PROVIDE SIX ORANGE SMOKE DISTRESS SIGNALS.
Condition: Unknown
Due 11 May 1988
Resolved 11 May 1988