Records from 2007 to 2025. Most recent: inspection, 16 September 2025.
Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 33
16 September 2025
Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8235402
28 August 2024
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8021092
8 May 2024
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7909543
8 May 2024
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7912700
19 July 2023
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7750799
22 June 2023
Administrative Inspection · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7727100
22 June 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7730352
27 April 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7678672
26 April 2023
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7676535
15 February 2023
Administrative Inspection · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7637509
15 February 2023
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7639418
6 December 2022
Examination of Repairs · Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7605026
3 December 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7605704
12 August 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7547901
10 August 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7529952
8 August 2022
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7538350
20 July 2022
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7511748
1 July 2021
In-Service Inspection · COI Inspection · Hull Examination · Examination of Repairs
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7218685
12 February 2021
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7144012
10 September 2020
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7055228
27 May 2020
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6962469
20 March 2020
Damage Survey
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6930365
24 July 2019
Type not recorded
No type recorded · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6768477
11 July 2019
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6746293
10 October 2018
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6561758
20 September 2018
Annual Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6544532
24 October 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6303503
2 June 2017
Administrative Inspection
Administrative · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6163749
8 February 2017
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6085229
2 February 2017
In-Service Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6085226
21 October 2016
Deficiency Check · COI Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6023841
16 September 2016
Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6006889
29 January 2016
Deficiency Check
Physical examination · Sector Northern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5812252
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 16 September 2025
Resolved
Mainland side ramp cable is chafed, must be replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 29 September 2025
Resolution: replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 16 September 2025
Resolved
SSDG has chafed hydraulic lines which must be replaced.
SSDG has small coolant leak at line fitting, must be repaired or replaced.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 September 2025
Resolved 29 September 2025
Resolution: replaced, corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 16 September 2025
Resolved
Engine room rotating machinery must be properly protected by a cover, guard, or rail.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 October 2025
Resolved 1 October 2025
Resolution: protective rails installed.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 19 July 2023
Resolved
Island side collision bulkhead valve not functioning – correct & demonstrate proper operation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 1 August 2023
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 19 July 2023
Resolved
Ramp cable improperly routed, damaged overhead primary girder (mainland side). Submit repair proposal; effect repairs upon approval.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 August 2023
Resolved 17 August 2023
Resolution: repaired.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 15 February 2023
Resolved
Steering system cannon plug connectors to steering gear actuator boxes worn which caused the plugs to vibrate loose. Plugs were reconnected and secured to avoid loosening. Dockside and underway testing was completed, all sat.
This temporary repair is approved. EUPTA is ordering replacement plug connectors. Permanent repair required.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 March 2023
Resolved 23 March 2023
Resolution: All plug connectors have been replaced, operational tests witnessed, all sat.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 6 December 2022
Resolved
Vessel must be made available for Coast Guard inspectors to conduct thorough island side internal and external damage survey to determine extent of damage.
Action required: 60 - Rectify deficiencies prior to movement
Due 6 December 2022
Resolved 6 December 2022
Resolution: Vessel was made available for thorough damage survey.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 6 December 2022
Resolved
Temporary repair plans must be submitted for approval to [name withheld] to make the island side peak void watertight. Island side must be made watertight IAW approved plans prior to movement.
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2022
Resolved 6 December 2022
Resolution: Temp repair plans approved, temp repairs completed and inspected.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 6 December 2022
Resolved
Repair proposal must be submitted for approval to [name withheld] to make permanent repairs to the island side king posts, ramp and associated appurtenances prior to any further use of the island side ramp/system.
Permanent repairs shall be completed upon repair proposal approval.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 January 2023
Resolved 16 January 2023
Resolution: Permanent repairs completed, all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 September 2022
Resolved
Lifejacket stowage containers require remarking.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 20 October 2022
Resolution: corrected.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 20 September 2022
Resolved
Steering system cannon plug temp fix, permanent repair is required.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2022
Resolved 20 October 2022
Resolution: replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 20 September 2022
Resolved
Coll blkhd closure valve inop, requires repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2022
Resolved 20 October 2022
Resolution: repaired.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 July 2021
Resolved
Pilothouse bilge alarm panel needs permanent markings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 1 July 2021
Resolution: corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 July 2021
Resolved
Pilothouse portable fire extinguisher needs to be properly mounted (or replaced with correct PFE).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 1 July 2021
Resolution: corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 July 2021
Resolved
Both main deck ring life buoys require attention. Mainland side needs retro-reflective tape applied; island side needs to be replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 1 July 2021
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2021
Resolved
Passenger accommodation space storage closet dead-end wiring must be capped or removed; camera back-up power supply must be permanently wired (& extension cord removed).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 1 July 2021
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access Deck - hold/tank, etc.
Issued 1 July 2021
Resolved
Bridge wing access door needs door handles installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 July 2021
Resolved 1 July 2021
Resolution: corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 February 2021
Resolved
During transit, the engineer conducted a round of the machinery space and identified loss of oil cooler on the main propulsion engine. Determine cause of failure, effect reparies, and prove proper operation of the propulsion main engine prior to deparutre from Sault Ste. [name withheld] Terminal.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 February 2021
Resolution: Got underway with the vessel to conduct sea trials of the main propulsion engine once engine was repaired. Sea trials were conducted satisfactory.
01 - Certificates & Documentation › 012 - Crew Certificates › Evidence of Basic Training
Issued 10 September 2020
Resolved
Provide documentation attesting to having held recent emergency drills and training.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 September 2020
Resolved 23 September 2020
Resolution: Received proper documentation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 March 2020
Resolved
Deck rails must be designed and constructed to withstand a point load of 200 lbs applied in any direction and a uniform load of 50 lbs per foot applied to the top rail in any direction. The island end, port side bitt is cracked and the hand rail attached to the bulwark is bent. Submit repair proposal for base of bitt in accordance with applicable regulations, to the Officer in Charge, Marine Inspections Sault Sainte Marie, by 30 March 2020.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 March 2020
Resolved 27 May 2020
Resolution: corrected.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 11 July 2019
Resolved
Correctly label bilge alarm panel for engine room high water at the operating station.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 25 July 2019
Resolution: corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 11 July 2019
Resolved
Engine room bilges have trash, debris and oily water accumulation. Engine room in disarray, deck plates oily, loose gear, tools, spare parts and oil containers not secured creating hazardous work environment/potential bilge pumping clogs.
Steering hardware (hydraulic rams, hoses) and steering compartments covered and coated with fluid, dirt and debris creating hazardous work environment/potential bilge pumping clogs.
Thoroughly clean and make ready for inspection steering compartments, engine room bilge and deck plates. Stow all loose gear and properly store or remove all oil/chemicals in vessels engine room.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 July 2019
Resolved 25 July 2019
Resolution: All spaces were cleaned and are free of gear adrift.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 September 2018
Resolved
Main engine lube oil pressure gages are required at the operating station. Repair inoperable lube oil pressure gauges in wheelhouse consoles before 27SEP2018 and demonstrate proper operation of same to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 September 2018
Resolved 10 October 2018
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 September 2018
Resolved
Electrical systems must be safe and maintained properly. Repair or replace multiple missing or broken fuse caps in wheelhouse electrical lighting panel, before 04OCT2018, to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2018
Resolved 10 October 2018
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 20 September 2018
Resolved
Fire and safety hazards must be minimized in accomodations areas. Guard missing on overhead heater fan, sharp edges from bent vent louvers and metal wall coverings present physical injury hazards and must be corrected before 04OCT2018 to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2018
Resolved 10 October 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 20 September 2018
Resolved
Machinery must be maintained properly. Excessive leakage from engine cooling system for #2 ship service generator must be repaired and proper operation to be proven before 20OCT2018, to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2018
Resolved 10 October 2018
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 20 September 2018
Resolved
Bilge alarms must indicate which space is flooded. 5 bilge alarms in the wheelhouse are not labeled. Provide legible permanent label for each bilge alarm light at the operating station, before 04OCT2018, to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 October 2018
Resolved 10 October 2018
Fire Fighting › Fixed Fire Detection System › Indicator Light
Issued 8 November 2017
Resolved
Repair and demonstrate operation of fire alarm strobe light in engineroom.
Condition: Invalid
Action required: 705 - Other - as specified
Due 8 December 2017
Resolved 7 December 2017
Resolution: All 3 engineroom sensors and the audible/visual alarm were replaced by servicing technician. Completed ops check of all system components and pilothouse annunciator panel, all sat.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 24 October 2017
Resolved
Provide testing and servicing report for fixed smoke/fire detection & alarm system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 8 November 2017
Resolution: system serviced by Alpena Fire in my presence
Fire Fighting › Fire Hoses › Connections
Issued 24 October 2017
Resolved
provide spanner wrenches at each fire station
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 8 November 2017
Resolution: installed at each fire station
Electrical › Electric Supply System (service) › Battery Installation
Issued 24 October 2017
Resolved
E/R batteries must be properly secured to prevent shifting.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 8 November 2017
Resolution: installed chocks in all bsttery boxes
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 October 2017
Resolved
E/R emergency escape must be properly marked on the main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2017
Resolved 8 November 2017
Resolution: emergency exit properly marked
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 October 2017
Resolved
replaced expired items in first aid kit
Condition: Invalid
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 8 November 2017
Resolution: replaced
Engineering › Bilge Water Management System › Pump
Issued 24 October 2017
Resolved
provide operable portable hand bilge pump (handle missing)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 8 November 2017
Resolution: provided
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 24 October 2017
Resolved
post EAP information
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 November 2017
Resolved 8 November 2017
Resolution: posted
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 31 October 2016
Resolved
Demonstrate compliance with random drug testing requirements by providing last three test results of members employed on the vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 30 November 2016
Lifesaving › Lifebuoys › Serviceable
Issued 31 October 2016
Resolved
Replace UV damaged life line on life bouy outside of pilot house.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2016
Resolved 9 November 2016
Resolution: Completed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 31 October 2016
Resolved
Provide current revision of light list.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 1 December 2016
Resolution: Completed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 October 2016
Resolved
Wrap line from light on ring buoy around the body to the ring.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2016
Resolved 31 October 2016
Resolution: Cleared on the spot.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 31 October 2016
Resolved
Replace dry rotted hose on B-II fire extinguisher. Completed, however we found an additional extinguisher with dry rotted hose so will extend the def for the additional ext. Added - properly secure hose/nozzle ass'y on each portable fire ext. on main deck.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 17 November 2016
Resolution: Completed hose repalcement and securing of hose/nozzle assemblies.
Navigation › Piloting/Steering › Marine Charts
Issued 31 October 2016
Resolved
Provide updated chart of operating area.
Condition: Invalid
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 17 November 2016
Resolution: Updated charts verified on board.
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 October 2016
Resolved
Tape and place within an enclosure both twist on type connections for windshield heater controller under mainland side consel.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 9 November 2016
Resolution: Wire connections under console properly repaired and connected.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 31 October 2016
Resolved
Mark life jacket stowage containers with the number of life jackets stowed in each container.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 9 November 2016
Resolution: Completed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 31 October 2016
Resolved
Make quick release for life jackets stowed on the bridge wing operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 November 2016
Resolved 9 November 2016
Resolution: Completed.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 31 October 2016
Resolved
Make life jacket stowage quick release operable by a person standing on the deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 9 November 2016
Resolution: Rescinded, found to not be applicable to existing vessel per 46CFR180.
Fire Fighting › Nozzles › Condition
Issued 31 October 2016
Resolved
Make nozzle at number 1 firestation operable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2016
Resolved 31 October 2016
Resolution: corrected on the spot.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 31 October 2016
Resolved
Remove and clean excessive oil from bilges in engine room.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2016
Resolved 9 November 2016
Resolution: Completed.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 31 October 2016
Resolved
Provide name plate that derates both generators to 80% of full load capacity based on 40 degree celcius generator rating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 1 December 2016
Resolution: Sighted appropriate signage adhered to both gensets.
Electrical › Electrical Distribution System (service) › Cable
Issued 31 October 2016
Resolved
Properly support new installation wiring with metalic banding every 24 inches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 9 November 2016
Resolution: Completed.
Electrical › Electrical Distribution System (service) › Cable
Issued 31 October 2016
Resolved
Repair insulation on cranking motor wireson both MDE's & provide safe mounting to reduce risk of chaffing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 17 November 2016
Resolution: Completed.
Engineering › Steering Gear System › Ram
Issued 21 October 2016
Resolved
Make permanent repairs to linkage pins IWO island end hydraulic ram.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 17 November 2016
Resolution: Completed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 October 2016
Resolved
Replace retro-reflective markings on wheelhouse RLB.
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 17 November 2016
Resolution: Completed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 October 2016
Resolved
Provide proper lanyard and mounting bracket for float light on main deck RLB.
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 17 November 2016
Resolution: Completed.