TILGHMAN LADY

TILGHMAN LADY is a 1955 passenger vessel (inspected). The Coast Guard has recorded 39 inspections since 1985, most recently in November 2002, along with 73 deficiencies.

Records from 1985 to 2002. Most recent: inspection, 1 November 2002.

Built
1955
Last inspected
1 November 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WH8346
Flag
UNITED STATES
—
Maury page id
psix-43111

Inspections, by type

…with no type recorded6
Years with a record 17 calendar years (1985–2002)
The 39 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it9 - Regulatory (Subpart C or D), Net Ton
14 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCX4374MMSI not assigned · expired · compulsorily equipped · granted 30 April 1997, cancelled 1 July 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 39

1 November 2002 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1699620
1 November 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1484004
22 February 2001 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1057963
23 October 2000 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1448185
3 October 2000 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1455922
8 September 1999 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1406563
24 November 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 808411
13 October 1998 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 802775
3 August 1998 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 800419
23 July 1998 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 800365
2 September 1997 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 786190
24 August 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 97179
8 July 1997 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1446515
2 May 1996 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1355781
9 April 1996 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1079754
31 July 1995 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1188308
31 July 1995 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1454260
9 August 1994 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1173745
5 May 1994 Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 861566
19 April 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 660792
20 February 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 90012
3 November 1993 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1150073
14 July 1993 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 847146
20 April 1993 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1138146
29 December 1992 Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1133163
11 December 1992 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1134709
27 July 1992 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 944866
24 June 1992 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 952446
3 June 1992 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1258378
11 June 1991 Hull Examination · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1325859
28 June 1989 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 886490
27 June 1989 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1198565
13 May 1988 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1348325
15 January 1988 Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1320834
5 June 1987 Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1002245
23 May 1986 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 987260
29 January 1986 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1305724
20 September 1985 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 990972
28 June 1985 Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1286486

Deficiency record · 73

Construction/Loadline › Hull › Bottom Plating
Issued 1 November 2002 Resolved
Complete a credit dry-dock hull exam and complete all worklist items prior to carrying passengers. To be completed to the satifaction of the cognizant OCMI and attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2003
Resolved 17 November 2005
Resolution: ADMIN - COI Deactivated
Documentation
Issued 23 October 2000 Resolved
POST CERTIFICATES.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Lifesaving
Issued 23 October 2000 Resolved
PROVIDE TWO ADULT PFD'S.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Construction/Loadline
Issued 3 October 2000 Resolved
ADDRESS ROT AROUND CABIN WINDOW, STARBOARD SIDE.
Condition: Unknown
Due 3 November 2000
Resolved 18 October 2000
Construction/Loadline
Issued 3 October 2000 Resolved
REPLACE STRAINER TO STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 4 October 2000
Resolved 18 October 2000
Accommodation/Occupational Safety
Issued 3 October 2000 Resolved
MOUNT TOILET.
Condition: Unknown
Due 3 November 2000
Resolved 18 October 2000
Construction/Loadline
Issued 3 October 2000 Resolved
CLEAN BILGES.
Condition: Unknown
Due 10 October 2000
Resolved 18 October 2000
Documentation
Issued 8 September 1999 Resolved
Provide FCC operators permit
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Electrical
Issued 8 September 1999 Resolved
Line battery box with acid ressitant material
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Electrical
Issued 8 September 1999 Resolved
Install cover to battery box
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Fire Fighting
Issued 8 September 1999 Resolved
Service fixed firefighting system
Condition: Unknown
Due 10 September 1999
Resolved 20 September 1999
Documentation
Issued 8 September 1999 Resolved
AFFIX NAME OF VESSEL TO BOW.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Electrical
Issued 8 September 1999 Resolved
Replace bulb and light cover in foward compartment
Condition: Unknown
Due 7 October 1999
Resolved 27 September 1999
Accommodation/Occupational Safety
Issued 8 September 1999 Resolved
Refasten handrail on gunwale starboard side
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Electrical
Issued 8 September 1999 Resolved
Resplice wiring to deck lights on port side
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Fire Fighting
Issued 8 September 1999 Resolved
Replace fire extinguisher bracket on the starboard side of foward cabin with one of proper size
Condition: Unknown
Due 10 September 1999
Resolved 20 September 1999
Accommodation/Occupational Safety
Issued 8 September 1999 Resolved
Refasten handrail to foward ladder starboard side
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Fire Fighting
Issued 8 September 1999 Resolved
Recharge and replace tamper seal on portable fire extinguisher portside of foward cabin
Condition: Unknown
Due 10 September 1999
Resolved 20 September 1999
Lifesaving
Issued 8 September 1999 Resolved
REPAIR OR REPLACE LIFE FLOAT.
Condition: Unknown
Due 7 October 1999
Resolved 27 September 1999
Construction/Loadline
Issued 8 September 1999 Resolved
Repair high water bilge alarm forward
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Fire Fighting
Issued 8 September 1999 Resolved
Mount fixed firefighting heat detector and rehang wiring
Condition: Unknown
Due 10 September 1999
Resolved 20 September 1999
Engineering
Issued 8 September 1999 Resolved
Install hose clamp on port exhaust cooling line to main diesel engine
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Engineering
Issued 8 September 1999 Resolved
Install mounting bracket for solenoid on port main diesel engine
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Accommodation/Occupational Safety
Issued 8 September 1999 Resolved
Repair/replace second broken step to starboard side ladder
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Electrical
Issued 8 September 1999 Resolved
Install safety plugs in all open deck light sockets
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Accommodation/Occupational Safety
Issued 13 October 1998 Resolved
REPAIR PORT HANDRAIL, MAINDECK AMIDSHIPS, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 October 1998
Resolved 13 October 1998
Fire Fighting
Issued 13 October 1998 Resolved
REPAIR FIRE PUMP PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 October 1998
Resolved 13 October 1998
Fire Fighting
Issued 23 July 1998 Resolved
PROVIDE NOZZLE FOR FIRE HOSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Construction/Loadline
Issued 23 July 1998 Resolved
PROVIDE THREADED CAP FOR UNUSED GENERATOR WATER SUPPLY VALVE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Navigation
Issued 23 July 1998 Resolved
ADDRESS EXCESSIVE LEAK AT STBD RUDDER PACKING PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Construction/Loadline
Issued 23 July 1998 Resolved
PROVE PROPER OPERATION OF BILGE MANIFOLD SYSTEM & ENGINE ROOM ELECTRIC PUMPFLOAT SWITCH PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Accommodation/Occupational Safety
Issued 23 July 1998 Resolved
ADDRESS ROT IN AFT PORTION OF PILOTHOUSE.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Accommodation/Occupational Safety
Issued 23 July 1998 Resolved
REPAIR UPPER DECK STBD SIDE HANDRAIL PRIOR TO PERMITTING PASSENGERS ON UPPER DECK.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Construction/Loadline
Issued 23 July 1998 Resolved
ADDRESS ROT IN UPPER STRAKE STRIP PLANKING PORT AND STBD SIDES FORWARD.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Engineering
Issued 23 July 1998 Resolved
REFASTEN PORT SHAFT INTERMEDIATE BEARING PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 8 July 1997 Resolved
Provide additional reflective tape, pendants, paddles and repair to cover of life floats.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Electrical
Issued 8 July 1997 Resolved
Tighten battery connections.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Documentation
Issued 8 July 1997 Resolved
Provide passenger capacity plate for upper deck.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Navigation
Issued 8 July 1997 Resolved
Remove air tank for air horn.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Lifesaving
Issued 8 July 1997 Resolved
Provide additional reflective tape for 16 adult and 7 child PFD's.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Engineering
Issued 8 July 1997 Resolved
Provide strainer for port MDE coolant supply._x001C_
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Engineering
Issued 8 July 1997 Resolved
Replace fuel hose with USCG approved fuel hose._x001C_
Condition: Unknown
Due 22 July 1997
Resolved 21 July 1997
Engineering
Issued 8 July 1997 Resolved
Replace stbd MDE coolant hose (after end).
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Engineering
Issued 8 July 1997 Resolved
Tighten port shaft packing.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Engineering
Issued 8 July 1997 Resolved
Resecure stbd shaft roller bearing.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Electrical
Issued 8 July 1997 Resolved
Remove house cable stbd side of fuel compartment._x001C_
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Accommodation/Occupational Safety
Issued 8 July 1997 Resolved
Secure forward ladder properly.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Construction/Loadline
Issued 8 July 1997 Resolved
Provide securing chain for forward hatch.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Electrical
Issued 2 May 1996 Resolved
A speaker wire was used in the engine room on a 12 volt system._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 May 1996
Resolved 26 June 1996
Electrical
Issued 2 May 1996 Resolved
Wing nuts were used to attatch wires to the main starting batteries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 May 1996
Resolved 26 June 1996
Lifesaving
Issued 31 July 1995 Resolved
Nylon webbing and lifeline on ringbuoy wasted, need to be replaced._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Lifesaving
Issued 31 July 1995 Resolved
Mark location and stow seperate the child PFD's._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Construction/Loadline
Issued 31 July 1995 Resolved
The impellor for the PTO bilge pump was worn out. Replace and demonstrate operation. Sufficient electric bilge pumps onboard as req._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Electrical
Issued 31 July 1995 Resolved
Positive terminal lead for battery corroded and insulation worn. Replace inlike kind._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Navigation
Issued 31 July 1995 Resolved
Copper hydraulic lines for steering suspended(supported)by plastic wire ties. Change out to tubing hangers or other suitable material.
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Electrical
Issued 31 July 1995 Resolved
Auxillary generator for fishing deck lighting(non-vital) inop. Generating motor out for repair/estimate at time of inspection. Repair or Remove._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Electrical
Issued 31 July 1995 Resolved
Replace all wire nuts on bilge pump wiring with butt connectors._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Lifesaving
Issued 31 July 1995 Resolved
Reflective tape missing on PFD's 01 Child/02 Adult._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Construction/Loadline
Issued 27 July 1992 Resolved
INSTALL AT OPERATING STATION, AUTO/OPERATIION INDICATOR LIGHTS FOR 4 BILGE PUMPS(S)
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Engineering
Issued 27 July 1992 Resolved
PROVIDE PLANS AND INSTALL 1 INTAKE/1EXHAUST VENT IN ENGINE ROOM.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Documentation
Issued 27 July 1992 Resolved
PROVIDE AND DISPLAY THE FOLLOWING FCC CERTIFICATES: OPERATORS LICENSE; STATION LICENSE; SAFETY CERTIFICATE.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Lifesaving
Issued 3 June 1992 Resolved
PROVIDE 26 ADDITIONAL ADULT PFD'S, TOTAL PERSONS ALLOWED IS REDUCED TO 112 UNTIL PROVIDED.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Electrical
Issued 11 June 1991 Resolved
PROVIDE OVERCURRENT PROTECTION FOR INSTALLED SERVICE GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Construction/Loadline
Issued 28 June 1989 Resolved
FOUND WASTED FASTENERS IN THE STEM AND BOW AREA, ISSUED 835 TO HAUL OUT PRIOR TO COI. COMPLETED 27 JUN 89 SEE MI89020372
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Lifesaving
Issued 5 June 1987 Resolved
20 PERSON L/F TORN ,MAKE REPAIRS.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Construction/Loadline
Issued 5 June 1987 Resolved
MAKE BILGE PUMPING SYSTEM OPERATIONAL.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Fire Fighting
Issued 5 June 1987 Resolved
SERVICE FIXED CO-2 SYSTEM.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Electrical
Issued 5 June 1987 Resolved
RENEW CHAFFED AND CORRODED BATTERY CABLES.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Electrical
Issued 5 June 1987 Resolved
REMOVE BIRDS NESTS AND HOUSEHOLD WIREING FROM VESSEL.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Lifesaving
Issued 5 June 1987 Resolved
REMOVE FROM VESSEL IMPROPER LIFE FLOAT.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Construction/Loadline
Issued 29 January 1986 Resolved
RENEW THE THIRD PLANK UP FROM THE BOTTOM OF THE TRANSOM FROM THE PORT SIDE TO A POINT 2FT INBOARD.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Construction/Loadline
Issued 29 January 1986 Resolved
RENEW THE SECOND PLANK UP FROM THE BOTTOM OF THE TRANSOM FROM THE CENTERLINE TO THE PORT SIDE.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Construction/Loadline
Issued 29 January 1986 Resolved
RENEW THAT PORTION OF THE KEEL FROM THE STOPWATER TOA POINT 6 FT AFT, THEN SCARF IN AT A 1TO6 RATIO.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986

Ownership record