Records from 1985 to 2002. Most recent: inspection, 1 November 2002.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 39
1 November 2002
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1699620
1 November 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1484004
22 February 2001
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1057963
23 October 2000
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1448185
3 October 2000
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1455922
8 September 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1406563
24 November 1998
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 808411
13 October 1998
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 802775
3 August 1998
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 800419
23 July 1998
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 800365
2 September 1997
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 786190
24 August 1997
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 97179
8 July 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1446515
2 May 1996
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1355781
9 April 1996
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1079754
31 July 1995
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1188308
31 July 1995
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1454260
9 August 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1173745
5 May 1994
Hull Examination
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 861566
19 April 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 660792
20 February 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 90012
3 November 1993
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1150073
14 July 1993
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 847146
20 April 1993
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1138146
29 December 1992
Drydock Extension
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1133163
11 December 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1134709
27 July 1992
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 944866
24 June 1992
Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 952446
3 June 1992
Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1258378
11 June 1991
Hull Examination · COI Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1325859
28 June 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 886490
27 June 1989
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1198565
13 May 1988
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1348325
15 January 1988
Hull Examination · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1320834
5 June 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1002245
23 May 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 987260
29 January 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1305724
20 September 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 990972
28 June 1985
Re-Inspection · Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1286486
Construction/Loadline › Hull › Bottom Plating
Issued 1 November 2002
Resolved
Complete a credit dry-dock hull exam and complete all worklist items prior to carrying passengers. To be completed to the satifaction of the cognizant OCMI and attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2003
Resolved 17 November 2005
Resolution: ADMIN - COI Deactivated
Documentation
Issued 23 October 2000
Resolved
POST CERTIFICATES.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Lifesaving
Issued 23 October 2000
Resolved
PROVIDE TWO ADULT PFD'S.
Condition: Unknown
Due 23 October 2000
Resolved 23 October 2000
Construction/Loadline
Issued 3 October 2000
Resolved
ADDRESS ROT AROUND CABIN WINDOW, STARBOARD SIDE.
Condition: Unknown
Due 3 November 2000
Resolved 18 October 2000
Construction/Loadline
Issued 3 October 2000
Resolved
REPLACE STRAINER TO STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 4 October 2000
Resolved 18 October 2000
Accommodation/Occupational Safety
Issued 3 October 2000
Resolved
MOUNT TOILET.
Condition: Unknown
Due 3 November 2000
Resolved 18 October 2000
Construction/Loadline
Issued 3 October 2000
Resolved
CLEAN BILGES.
Condition: Unknown
Due 10 October 2000
Resolved 18 October 2000
Documentation
Issued 8 September 1999
Resolved
Provide FCC operators permit
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Electrical
Issued 8 September 1999
Resolved
Line battery box with acid ressitant material
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Electrical
Issued 8 September 1999
Resolved
Install cover to battery box
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Fire Fighting
Issued 8 September 1999
Resolved
Service fixed firefighting system
Condition: Unknown
Due 10 September 1999
Resolved 20 September 1999
Documentation
Issued 8 September 1999
Resolved
AFFIX NAME OF VESSEL TO BOW.
Condition: Unknown
Due 8 September 1999
Resolved 8 September 1999
Electrical
Issued 8 September 1999
Resolved
Replace bulb and light cover in foward compartment
Condition: Unknown
Due 7 October 1999
Resolved 27 September 1999
Accommodation/Occupational Safety
Issued 8 September 1999
Resolved
Refasten handrail on gunwale starboard side
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Electrical
Issued 8 September 1999
Resolved
Resplice wiring to deck lights on port side
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Fire Fighting
Issued 8 September 1999
Resolved
Replace fire extinguisher bracket on the starboard side of foward cabin with one of proper size
Condition: Unknown
Due 10 September 1999
Resolved 20 September 1999
Accommodation/Occupational Safety
Issued 8 September 1999
Resolved
Refasten handrail to foward ladder starboard side
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Fire Fighting
Issued 8 September 1999
Resolved
Recharge and replace tamper seal on portable fire extinguisher portside of foward cabin
Condition: Unknown
Due 10 September 1999
Resolved 20 September 1999
Lifesaving
Issued 8 September 1999
Resolved
REPAIR OR REPLACE LIFE FLOAT.
Condition: Unknown
Due 7 October 1999
Resolved 27 September 1999
Construction/Loadline
Issued 8 September 1999
Resolved
Repair high water bilge alarm forward
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Fire Fighting
Issued 8 September 1999
Resolved
Mount fixed firefighting heat detector and rehang wiring
Condition: Unknown
Due 10 September 1999
Resolved 20 September 1999
Engineering
Issued 8 September 1999
Resolved
Install hose clamp on port exhaust cooling line to main diesel engine
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Engineering
Issued 8 September 1999
Resolved
Install mounting bracket for solenoid on port main diesel engine
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Accommodation/Occupational Safety
Issued 8 September 1999
Resolved
Repair/replace second broken step to starboard side ladder
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Electrical
Issued 8 September 1999
Resolved
Install safety plugs in all open deck light sockets
Condition: Unknown
Due 7 October 1999
Resolved 20 September 1999
Accommodation/Occupational Safety
Issued 13 October 1998
Resolved
REPAIR PORT HANDRAIL, MAINDECK AMIDSHIPS, PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 October 1998
Resolved 13 October 1998
Fire Fighting
Issued 13 October 1998
Resolved
REPAIR FIRE PUMP PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 13 October 1998
Resolved 13 October 1998
Fire Fighting
Issued 23 July 1998
Resolved
PROVIDE NOZZLE FOR FIRE HOSE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Construction/Loadline
Issued 23 July 1998
Resolved
PROVIDE THREADED CAP FOR UNUSED GENERATOR WATER SUPPLY VALVE PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Navigation
Issued 23 July 1998
Resolved
ADDRESS EXCESSIVE LEAK AT STBD RUDDER PACKING PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Construction/Loadline
Issued 23 July 1998
Resolved
PROVE PROPER OPERATION OF BILGE MANIFOLD SYSTEM & ENGINE ROOM ELECTRIC PUMPFLOAT SWITCH PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Accommodation/Occupational Safety
Issued 23 July 1998
Resolved
ADDRESS ROT IN AFT PORTION OF PILOTHOUSE.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Accommodation/Occupational Safety
Issued 23 July 1998
Resolved
REPAIR UPPER DECK STBD SIDE HANDRAIL PRIOR TO PERMITTING PASSENGERS ON UPPER DECK.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Construction/Loadline
Issued 23 July 1998
Resolved
ADDRESS ROT IN UPPER STRAKE STRIP PLANKING PORT AND STBD SIDES FORWARD.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Engineering
Issued 23 July 1998
Resolved
REFASTEN PORT SHAFT INTERMEDIATE BEARING PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 23 July 1998
Resolved 23 July 1998
Lifesaving
Issued 8 July 1997
Resolved
Provide additional reflective tape, pendants, paddles and repair to cover of life floats.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Electrical
Issued 8 July 1997
Resolved
Tighten battery connections.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Documentation
Issued 8 July 1997
Resolved
Provide passenger capacity plate for upper deck.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Navigation
Issued 8 July 1997
Resolved
Remove air tank for air horn.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Lifesaving
Issued 8 July 1997
Resolved
Provide additional reflective tape for 16 adult and 7 child PFD's.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Engineering
Issued 8 July 1997
Resolved
Provide strainer for port MDE coolant supply._x001C_
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Engineering
Issued 8 July 1997
Resolved
Replace fuel hose with USCG approved fuel hose._x001C_
Condition: Unknown
Due 22 July 1997
Resolved 21 July 1997
Engineering
Issued 8 July 1997
Resolved
Replace stbd MDE coolant hose (after end).
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Engineering
Issued 8 July 1997
Resolved
Tighten port shaft packing.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Engineering
Issued 8 July 1997
Resolved
Resecure stbd shaft roller bearing.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Electrical
Issued 8 July 1997
Resolved
Remove house cable stbd side of fuel compartment._x001C_
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Accommodation/Occupational Safety
Issued 8 July 1997
Resolved
Secure forward ladder properly.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Construction/Loadline
Issued 8 July 1997
Resolved
Provide securing chain for forward hatch.
Condition: Unknown
Due 8 July 1997
Resolved 8 July 1997
Electrical
Issued 2 May 1996
Resolved
A speaker wire was used in the engine room on a 12 volt system._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 May 1996
Resolved 26 June 1996
Electrical
Issued 2 May 1996
Resolved
Wing nuts were used to attatch wires to the main starting batteries._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 May 1996
Resolved 26 June 1996
Lifesaving
Issued 31 July 1995
Resolved
Nylon webbing and lifeline on ringbuoy wasted, need to be replaced._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Lifesaving
Issued 31 July 1995
Resolved
Mark location and stow seperate the child PFD's._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Construction/Loadline
Issued 31 July 1995
Resolved
The impellor for the PTO bilge pump was worn out. Replace and demonstrate operation. Sufficient electric bilge pumps onboard as req._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Electrical
Issued 31 July 1995
Resolved
Positive terminal lead for battery corroded and insulation worn. Replace inlike kind._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 10 October 1995
Resolved 10 October 1995
Navigation
Issued 31 July 1995
Resolved
Copper hydraulic lines for steering suspended(supported)by plastic wire ties. Change out to tubing hangers or other suitable material.
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Electrical
Issued 31 July 1995
Resolved
Auxillary generator for fishing deck lighting(non-vital) inop. Generating motor out for repair/estimate at time of inspection. Repair or Remove._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Electrical
Issued 31 July 1995
Resolved
Replace all wire nuts on bilge pump wiring with butt connectors._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Lifesaving
Issued 31 July 1995
Resolved
Reflective tape missing on PFD's 01 Child/02 Adult._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 August 1995
Resolved 10 October 1995
Construction/Loadline
Issued 27 July 1992
Resolved
INSTALL AT OPERATING STATION, AUTO/OPERATIION INDICATOR LIGHTS FOR 4 BILGE PUMPS(S)
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Engineering
Issued 27 July 1992
Resolved
PROVIDE PLANS AND INSTALL 1 INTAKE/1EXHAUST VENT IN ENGINE ROOM.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Documentation
Issued 27 July 1992
Resolved
PROVIDE AND DISPLAY THE FOLLOWING FCC CERTIFICATES: OPERATORS LICENSE; STATION LICENSE; SAFETY CERTIFICATE.
Condition: Unknown
Due 27 July 1992
Resolved 27 July 1992
Lifesaving
Issued 3 June 1992
Resolved
PROVIDE 26 ADDITIONAL ADULT PFD'S, TOTAL PERSONS ALLOWED IS REDUCED TO 112 UNTIL PROVIDED.
Condition: Unknown
Due 3 June 1992
Resolved 3 June 1992
Electrical
Issued 11 June 1991
Resolved
PROVIDE OVERCURRENT PROTECTION FOR INSTALLED SERVICE GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Construction/Loadline
Issued 28 June 1989
Resolved
FOUND WASTED FASTENERS IN THE STEM AND BOW AREA, ISSUED 835 TO HAUL OUT PRIOR TO COI. COMPLETED 27 JUN 89 SEE MI89020372
Condition: Unknown
Due 28 June 1989
Resolved 28 June 1989
Lifesaving
Issued 5 June 1987
Resolved
20 PERSON L/F TORN ,MAKE REPAIRS.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Construction/Loadline
Issued 5 June 1987
Resolved
MAKE BILGE PUMPING SYSTEM OPERATIONAL.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Fire Fighting
Issued 5 June 1987
Resolved
SERVICE FIXED CO-2 SYSTEM.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Electrical
Issued 5 June 1987
Resolved
RENEW CHAFFED AND CORRODED BATTERY CABLES.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Electrical
Issued 5 June 1987
Resolved
REMOVE BIRDS NESTS AND HOUSEHOLD WIREING FROM VESSEL.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Lifesaving
Issued 5 June 1987
Resolved
REMOVE FROM VESSEL IMPROPER LIFE FLOAT.
Condition: Unknown
Due 5 June 1987
Resolved 5 June 1987
Construction/Loadline
Issued 29 January 1986
Resolved
RENEW THE THIRD PLANK UP FROM THE BOTTOM OF THE TRANSOM FROM THE PORT SIDE TO A POINT 2FT INBOARD.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Construction/Loadline
Issued 29 January 1986
Resolved
RENEW THE SECOND PLANK UP FROM THE BOTTOM OF THE TRANSOM FROM THE CENTERLINE TO THE PORT SIDE.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986
Construction/Loadline
Issued 29 January 1986
Resolved
RENEW THAT PORTION OF THE KEEL FROM THE STOPWATER TOA POINT 6 FT AFT, THEN SCARF IN AT A 1TO6 RATIO.
Condition: Unknown
Due 29 January 1986
Resolved 29 January 1986