Records from 1986 to 2026. Most recent: inspection, 6 May 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 34
6 May 2026
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8314685
1 April 2025
DAPI Audit · Plan Review "T" Boat · Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8118781
8 May 2024
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7909071
30 May 2023
Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7684074
7 June 2022
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7469955
8 December 2021
Examination of Repairs · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7373261
22 September 2021
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7312424
23 April 2021
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7332212
7 May 2019
COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6678806
8 May 2017
Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6178027
13 October 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6015251
9 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5885956
12 May 2014
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4854681
10 May 2012
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4321891
27 September 2011
Drydock Exam · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 4163486
12 May 2009
Deficiency Check · COI Inspection
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3469024
8 May 2008
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3206419
8 April 2007
Administrative Inspection · Construction Oversight · Plan Review "T" Boat · Annual Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2933364
2 October 2006
Hull Examination · Internal Structural Exam
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2792210
18 August 2006
Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 2755324
26 May 2005
Deficiency Check · Annual Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2378298
24 May 2004
Deficiency Check · COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2093914
11 July 2003
Plan Review "T" Boat
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2094359
8 May 2002
Administrative Inspection
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1699583
18 September 1992
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1267019
17 September 1992
Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1267018
16 October 1990
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1210918
8 September 1989
Hull Examination · COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1195065
17 May 1988
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1196194
15 May 1987
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1032003
14 May 1987
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1023782
3 December 1986
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1024932
24 September 1986
Credit Drydock
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1009461
15 May 1986
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 988639
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 6 May 2026
No resolution recorded
Conduct underway man over board drills with CG Marine Inspector
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2026 — due date passed with no resolution recorded
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 May 2026
Resolved
Repair both broken stern and anchor light
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 15 July 2026
Resolution: Received pictures of repair.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 May 2026
Resolved
Replace missing mesh on second deck fwd deck rails
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2026
Resolved 15 July 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 May 2026
Resolved
Reinstall all items that were removed for painting and 2 deck cover replacement. Life ring bouy holder, fire extinguisher mount and life jacket holders and markings
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2026
Resolved 15 July 2026
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 May 2026
Resolved
remove dead end wire on main deck starboard side fwd going thought the gooseneck
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2026
Resolved 12 June 2026
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 May 2025
Resolved
repaint starboard side running light backer screen black.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 5 June 2025
Resolution: all sat
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 May 2025
Resolved
Replace first aid kit with a approved one.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 May 2025
Resolved 5 June 2025
Resolution: All sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2024
Resolved
Remark all life buoy rings with the vessels name.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 10 June 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 May 2024
Resolved
Prove proper operation of stern light before operating at night.
Action required: 705 - Other - as specified
Due 9 May 2024
Resolved 10 July 2024
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 May 2024
Resolved
Conduct underway man overboard drills with USCG inspectors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2024
Resolved 10 July 2024
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 May 2024
Resolved
Prove proper of pre-engineered fire fighting system. Vessel alarm is very quit, over ride switch didn’t work and no visual indication.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2024
Resolved 5 June 2025
Resolution: all sat
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 1 June 2023
Resolved
Prior to carrying passengers conduct underway man overboard drill and fire drill with USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2023
Resolved 10 July 2024
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 May 2023
Resolved
replace all combustible plastic trash cans with non-combustible ones with no openings in the sides or bottom
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 23 August 2023
Resolution: all sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 31 May 2023
Resolved
reinstall white webbed netting on all rails on deck
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2023
Resolved 8 May 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 31 May 2023
Resolved
Provide a first aid kit that meets the requirements of ISO 18813:2006
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2023
Resolved 23 August 2023
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 31 May 2023
Resolved
Prove proper operation of Audible Alarm at operating station
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 May 2023
Resolved 10 July 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 31 May 2023
Resolved
Label Exit on Main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 23 August 2023
Resolution: all sat
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 10 May 2016
Resolved
Mount fixed fire system in accordance with the MFG Instructions. Currently bottle is 45 degrees, MFG states either veritcal or 5 degress from horizontal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 November 2016
Resolution: Adimistravely closed
Lifesaving › Lifebuoys › Serviceable
Issued 10 May 2016
Resolved
Mount 1 life ring with line.
Due 19 May 2016
Resolved 19 May 2016
Resolution: Life ring mounted with line as required.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 May 2014
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 16 May 2014
Resolved 12 May 2014
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Electrical › Electric Supply System (service) › Cable
Issued 12 May 2014
Resolved
PROPERLY MOUNT ALL CABLE IN THE MACHINERY SPACE W/ METAL SUPPORTS.
Action required: 705 - Other - as specified
Due 26 May 2014
Resolved 13 May 2015
Resolution: Cables mounted properly.
Lifesaving › Hand Flares › Not on Board
Issued 12 May 2014
Resolved
PROVIDE 3 RED HAND FLARES AND 3 ORANGE SMOKE FLARES OR 6 ROCKET PARACHUTE FLARES. RESTRICTED TO VOYAGES OF 30 MINS OR LESS.
Action required: 705 - Other - as specified
Due 26 May 2014
Resolved 13 May 2014
Resolution: VESSEL OBTAINED 3 RED HAND FLARES AND 3 ORANGE SMOKE FLARES.
Construction/Loadline › Hull › Hull Plating
Issued 27 September 2011
Resolved
Provide hull gauging report for the entire hull of the vessel starting one foot above the chime.
Action required: 705 - Other - as specified
Resolved 10 May 2012
Resolution: After further isnpection and discussion with vsl owner, it has been determined that the coating presently installed is arresting any corrosion and nothing further is required right now.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 27 September 2011
Resolved
Properly bond both fuel tanks to the hull and provide non-abrasive and non-absorbent material on tank supports.
Action required: 705 - Other - as specified
Resolved 10 May 2012
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 27 September 2011
Resolved
Provide proper lifejacket stowage prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 10 May 2012
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 27 September 2011
Resolved
Provide machinery guards on steering cabling to both stern thruster stations.
Action required: 705 - Other - as specified
Resolved 10 May 2012
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 27 September 2011
Resolved
Provide lagging on stern heating boiler and replace exhaust piping with approved material.
Action required: 705 - Other - as specified
Resolved 10 May 2012
Stability › Watertight Integrity › General
Issued 27 September 2011
Resolved
Ensure watertight integrity of aft bulkhead in engine room space.
Action required: 705 - Other - as specified
Resolved 10 May 2012
Construction/Loadline › Structures › Superstructure
Issued 12 May 2009
Resolved
Renew cracked window STBD side main deck.
Action required: 705 - Other - as specified
Resolved 20 May 2009
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 8 May 2008
Resolved
Add 200 sq. cm of retroreflective tape to life jackets
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 4 September 2008
Electrical › Electrical Distribution System (service) › Conductor
Issued 8 May 2008
Resolved
Remove extention cord @ refrigerator.
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 4 September 2008
Electrical › Electrical Distribution System (service) › Conductor
Issued 8 May 2008
Resolved
Remove power strip from wheel house.
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 4 September 2008
Fire Fighting › Fire Pumps › Arrangement
Issued 8 May 2008
Resolved
Provide means to remotely operate fire fire pump @ operating station.
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 4 September 2008
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 May 2008
Resolved
Prove proper operation of automatic shutdown for fixed firefighting system.
Action required: 705 - Other - as specified
Due 8 June 2008
Resolved 4 September 2008
Construction/Loadline › Hull › Weld
Issued 2 October 2006
Resolved
Provide weld to underside of post pocket on portside fwd deck to make forepeak watertight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 27 October 2006
Resolved 16 May 2007
Operations/Management › Pollution › Arrival Reporting, Garbage
Issued 26 May 2005
Resolved
Post waste management plan.
Due 26 June 2005
Resolved 14 December 2005
Resolution: Received copy of waste management plan.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 26 May 2005
Resolved
Post life jacket donning placard.
Due 26 June 2005
Resolved 14 December 2005
Resolution: Provided proof of life jacket donning placard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 May 2005
Resolved
Replace expired items in first aid kit.
Due 26 June 2005
Resolved 14 December 2005
Resolution: Provided proof of purchase for first aid kit items.
Engineering › Gasoline Engine (auxiliary) › Ventilation
Issued 26 May 2005
Resolved
Provide fuel tanks for outboard motors that meet ABYC or UL standards.
Due 26 June 2005
Resolved 14 December 2005
Resolution: Corrected.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 26 May 2005
Resolved
Provide proof of vessel documentation.
Condition: Unknown
Due 26 June 2005
Resolved 14 December 2005
Resolution: Received proof of vessel documentation.
Communications › Audible Communications › SPD (Other)
Issued 26 May 2005
Resolved
Provide proper operation of fixed public address system.
Due 26 June 2005
Resolved 14 December 2005
Resolution: Provided repair information.
Fire Fighting › Fire Pumps
Issued 8 May 2002
Resolved
Install and prove proper operation of fire pump.
Action required: 705 - Other - as specified
Due 6 May 2007
Resolved 4 June 2004
Resolution: Granted portable pump until 2007
Engineering › Bilge Water Management System
Issued 8 May 2002
Resolved
Install and prove proper operation of bilge pumps in all W/T compartments, add hand pump to vessel inventory.
Action required: 705 - Other - as specified
Due 6 May 2007
Resolved 4 June 2004
Resolution: Granted waiver to use portable until 2007
Engineering › Steering Gear System
Issued 8 May 2002
Resolved
Repair forward P & S rudders. LEGACY COMPONENT DESC: Rudder
Action required: 705 - Other - as specified
Resolved 13 May 2003
Resolution: renewed wood rudders
Fire Fighting › Structural Fire Protection - General
Issued 8 May 2002
Resolved
Make engine compartment vapor tight as required for fixed F/E system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Resolution: gasket installed
Engineering › Diesel Engine (propulsion-direct drive)
Issued 8 May 2002
Resolved
Insulate MDE exhaust silencer or shield the exposed wood underdeck above silencer with suitable heat restistant material. LEGACY COMPONENT DESC: Silencer (exhaust)
Action required: 705 - Other - as specified
Resolved 24 May 2004
Resolution: exhaust lagged
Communications › Internal Communications System
Issued 8 May 2002
Resolved
Prove proper operation of PA system.
Action required: 705 - Other - as specified
Resolved 24 May 2004
Resolution: installed & tested
Accommodation/Occupational Safety › Occupational Safety
Issued 8 May 2002
Resolved
Install minimum 4 X 4 mesh guards on all exterior rails. LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Resolved 24 May 2004
Resolution: installed mesh
Accommodation/Occupational Safety › Medical/First Aid
Issued 8 May 2002
Resolved
Update 1st aid kit with new (un-expired) items (existing) and additional items as listed in CFR. LEGACY COMPONENT DESC: Medicine Chest
Action required: 705 - Other - as specified
Resolved 24 May 2004
Resolution: updated
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 8 May 2002
Resolved
Service all portable F/E's and provide certs. LEGACY COMPONENT DESC: Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Resolution: serviced
Lifesaving › Lifejacket/PFD (Type I)
Issued 8 May 2002
Resolved
Provide minimum of 155 PFD's (or to equal owners request for capacity if less) and 10% child. LEGACY COMPONENT DESC: Quantity
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2004
Resolution: 155A/16C
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 8 May 2002
Resolved
Complete installation of fixed F/E system (partially completed) and prove proper operation/shutdowns.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2004
Resolution: corrected per phonecon w/ owner
Construction/Loadline
Issued 24 September 1986
Resolved
REMOVE FROM VESSEL A 1 1/4 INCH PIPE VALVE AND SPOOL PIECE PORT AND STARBOARD SIDE AND WELD IN A INSERT IN THE TRANSOM.
Condition: Unknown
Due 24 September 1986
Resolved 24 September 1986