MAURY USCG vessel records Sign in
← All vessels

FLYING HIGH

FLYING HIGH is a passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 1995, most recently in May 2026, along with 28 deficiencies.

Records from 1995 to 2026. Most recent: inspection, 26 May 2026.

Built
Not recorded
Last inspected
26 May 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH9510
431533
Flag
UNITED STATES
—
Maury page id
psix-431533

Inspections, by type

Years with a record 19 calendar years (1995–2026)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records itNot recorded
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 27

26 May 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8412226
18 June 2025 Drydock Exam · COI Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8151424
4 June 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7927374
18 May 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7694373
24 May 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7471897
18 May 2021 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7204231
21 September 2020 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7067270
8 July 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7001215
5 May 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6948524
5 May 2020 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6948540
24 May 2019 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6698493
9 May 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6405226
19 May 2017 Annual Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6144303
13 May 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5876616
26 June 2003 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1911315
7 May 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1612534
29 September 2000 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1055850
20 November 1999 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 811515
28 September 1999 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1420204
22 September 1998 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1453519
20 May 1998 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 794457
31 October 1997 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1108718
2 October 1997 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1115849
22 September 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 829572
30 May 1996 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1088299
17 January 1996 Plan Review "T" Boat
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1355621
26 September 1995 Inclining Experiment · Hull Examination · Initial Certification · Plan Review "T" Boat
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1360266

Deficiency record · 28

01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 June 2025 Resolved
No person may use a vessel to which this part applies unless it has a number issued on a certificate of number by the issuing authority in the state of principal operation. Vessel unable to provide valid state registration or COD. 33CFR173.15(a)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 June 2025
Resolved 18 June 2025
Resolution: Vessel owner got state registration after inspection.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 18 June 2025 Resolved
The vessel owner shall maintain a log or otherwise record all maintenance and inspection performed on the vessel and its equipment. Vessel unable to provide maintenance record for parasail harnesses. 46CFR176.25-1(a) ASTM F3009-14 5.3.4.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2025
Resolved 1 July 2025
Resolution: Owner bought all new parasail harnesses and started new maintenance log.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 June 2024 Resolved
State registration expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 1 July 2025
Resolution: Recitfied
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 June 2024 Resolved
Crew training shall be logged or otherwise documented for review by the Coast Guard upon request. O/O had no records of training/drils.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 1 July 2025
Resolution: Drill record was onboard
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 4 June 2024 Resolved
Alcohol test strips expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 June 2024
Resolved 1 July 2025
Resolution: Valid alcohol test strips onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2023 Resolved
A vessel must be provided with a steering gear that is of adequate strength and capable of steering the vessel at all service speeds. The cable on the vessel's steering gear is damaged and the steering gear is inoperable. Replace cable and conduct a successful steering test approved by a marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 May 2023
Resolved 22 May 2023
Resolution: Replaced steering cable and conducted successful steering test. Vessel steering is fully functional.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 18 May 2021 Resolved
Provide documentation for annual servicing of fire extinguishing system. 46 CFR 176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2022
Resolution: Fire Extinguishing Service up to date.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 May 2021 Resolved
Replace struts to middle storage compartment for lifesaving equipment and batteries. 46 CFR 180.78
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 24 May 2022
Resolution: Verified
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 May 2021 Resolved
Repair punctures in ring buoy per manufacturers procedures. 46 CR 180.70
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 June 2021
Resolved 24 May 2022
Resolution: Replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 May 2021 Resolved
Provide name and hailing port on stern of vessel. 46 CFR 67.123
Action required: 705 - Other - as specified
Due 18 September 2021
Resolved 24 May 2022
Resolution: Verified name and hailing port.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 7 May 2002 Resolved
install engine restart switch
Condition: Improper Installation
Due 15 July 2002
Resolved 10 July 2002
Construction/Loadline
Issued 28 September 1999 Resolved
INVESTIGATE AND REPAIR LEAK IN TRANSOM WHERE OUT DRIVE PENETRATES HULL AND REPORT TO OFFICE.
Condition: Unknown
Due 28 September 1999
Resolved 28 September 1999
Lifesaving
Issued 22 September 1998 Resolved
VESSEL TO PROVIDE THREE (03) SMOKE SIGNALS.
Condition: Unknown
Due 22 October 1998
Resolved 26 October 1998
Construction/Loadline
Issued 2 October 1997 Resolved
PROVIDE SUFFICIENT SUCTION HOSE FOR HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Lifesaving
Issued 2 October 1997 Resolved
PROVIDE AND STOW ONBOARD THREE RED FLARES, APPROVAL #160.021
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Documentation
Issued 2 October 1997 Resolved
RENEW VESSEL'S REGISTRATION AND DISPLAY NUMBER IN ACCORDANCE WITH 33CFR173
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Engineering
Issued 2 October 1997 Resolved
DOUBLE CLAMP FUEL OIL VENT LINES.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Fire Fighting
Issued 2 October 1997 Resolved
SERVICE FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 2 October 1997
Resolved 2 October 1997
Engineering
Issued 22 September 1996 Resolved
INSTALL HOSE CLAMPS ON BOTH FUEL TANK VENT LINES.
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Lifesaving
Issued 22 September 1996 Resolved
LABLE PYRO BOX WITH DISTRESS SIGNALS IN 1/2" LETTERS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Engineering
Issued 22 September 1996 Resolved
PROVIDE SECOND INDEPENDENT MEANS OF ENGINE CONTROL_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Navigation
Issued 22 September 1996 Resolved
POST EMERGENCY BROADCAST PLACARD AS PER 184.506_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Engineering
Issued 22 September 1996 Resolved
SECURE HEAT EXCHANGER IN ENGINE ROOM_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Lifesaving
Issued 22 September 1996 Resolved
MARK LIFE BUOY WITH RETRO AS PER 185.604_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Fire Fighting
Issued 22 September 1996 Resolved
SERVICE ENGINE ROOM FIXED FIRE EX. SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Deck/Cargo
Issued 22 September 1996 Resolved
PROVIDE GROUND TACKLE INCLUDING ANCHOR AND LINE_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1996
Resolved 13 November 1996
Navigation
Issued 26 September 1995 Resolved
ATTAIN THE FCC SAFETY RADIOTELEPHONY CERTIFICATE AND THE FCC STATION LICENSE PRIOR TO THE START OF THE 1996 TOURIST SEASON.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995
Electrical
Issued 26 September 1995 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE, REPLACE BILGE PUMP WIRING WITH WIRING THAT IS APPROVED FOR WET LOCATIONS.
Condition: Unknown
Due 26 September 1995
Resolved 26 September 1995

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.