MAURY USCG vessel records
← All vessels

DELIVERANCE

Built
1956
Last inspected
12 September 2016
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 12 September 2016
…with no type recorded10
Operational controls 1 with no removal date recorded
Years with a record 26 calendar years (1985–2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Tonnage
22 - Regulatory (Subpart C or D), Gross Ton 22 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-43155
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. Only barges and towing vessels are in this archive, so any other vessel type in the same activity does not appear here: these lists are a floor, not a complete manifest.

FUEL PUSHER Towing Vessel · MISLE 487775 · 19 August 2004 · activity 2171029

Inspection history · 44

12 September 2016 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5999207
1 January 2015 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5144311
28 August 2012 Drydock Exam · Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · Deficiency Check · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4425493
19 December 2008 Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3382501
24 January 2007 Cargo Tank Internal · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2861283
19 January 2007 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2858730
29 November 2005 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2534515
31 August 2005 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2480290
25 October 2004 Annual Inspection · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2224706
19 August 2004 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2171029
18 December 2003 Cargo Tank Internal · Examination of Repairs · COI Inspection · Hull Examination · Internal Structural Exam
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1966627
24 July 2003 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1855569
30 August 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1670353
27 July 2001 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1070249
10 July 2000 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1420357
2 August 1999 Hull Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1411941
25 May 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1372632
26 March 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 14374
26 March 1999 Type not recorded
No type recorded · Station Fort Lauderdale · USCG Southeast District (CGD-SE) · Activity 1508806
31 July 1998 Hull Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1470730
27 June 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 76469
11 June 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 86420
28 October 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1112634
30 September 1997 MARPOL Annex II Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1456518
26 June 1996 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 934448
26 June 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1249368
13 December 1995 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1190355
27 October 1995 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 711639
23 October 1995 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1189693
7 July 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1435505
7 July 1993 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1457183
21 June 1993 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1354367
20 July 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 88954
13 July 1992 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1260063
23 June 1992 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1261885
26 June 1991 Hull Examination · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1244561
28 June 1990 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1218278
6 July 1989 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1036057
20 June 1989 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1343701
28 June 1988 COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1207152
27 August 1987 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1000177
22 May 1987 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1025341
2 July 1986 COI Inspection · Credit Drydock
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1003773
6 September 1985 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 990865

Deficiency record · 27

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 28 August 2012 Resolved
Provide proper rated hose for gasoline pump vent lines. Due in 14 days, 25 SEPT 12 IAW 46CFR32.50-30
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2012
Resolved 21 September 2012
Resolution: Provided proper rated hose for gasoline pump vent lines IAW 46CFR32.50-30
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Pumproom
Issued 28 August 2012 Resolved
Demonstrate proper cargo system operations IAW 46CFR31.01-1. Due in 14 days, 25 SEPT 12.
Action required: 705 - Other - as specified
Due 25 September 2012
Resolved 21 September 2012
Resolution: Demonstrated proper cargo system operations IAW 46CFR31.01-1.
Documentation › Markings/Placards › Warning Signs
Issued 28 August 2012 Resolved
Provide proper signage to include the following: WARNING; NO OPEN LIGHTS, NO SMOKING, NO VISITORS in accordance with 46CFR35.30-1 due in 14 days 25 SEPT 12.
Action required: 705 - Other - as specified
Due 25 September 2012
Resolved 21 September 2012
Resolution: Provided proper signage to include the following: WARNING; NO OPEN LIGHTS, NO SMOKING, NO VISITORS in accordance with 46CFR35.30-1
Construction/Loadline › Hull › Hull Plating
Issued 26 January 2009 Resolved
Complete credit dry-dock prior to engaging in commerce.
Action required: 705 - Other - as specified
Resolved 11 September 2012
Construction/Loadline › Hull › Hull Plating
Issued 26 January 2009 No resolution recorded
Submit mid-bofy gauging iaw 46CFR31.10-21a prior to completion of credit dry-dock
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Longitudinal Frame
Issued 26 January 2009 No resolution recorded
Replace longitudinal frame on CT bulkhead in Fwd & AFt rakes from bilge/bulkhead seam outward approximately 3 ft including bottom plate as needed not later than next dry-dock.
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Hull Plating
Issued 19 January 2007 Resolved
Make barge available for Hull, ISE, CTI exams, due 09JAN07. Do not operate barge until credit is complete.
Action required: 705 - Other - as specified
Resolved 24 January 2007
Resolution: Completed all exams, SAT
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 25 October 2004 Resolved
Install draft marks
Action required: 703 - Prior to bunkering operations
Resolved 5 November 2004
Resolution: installed
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 25 October 2004 Resolved
Submit vapor recovery plan to MSC for approval. 46 CFR 39.10-9
Action required: 703 - Prior to bunkering operations
Resolved 5 November 2004
Resolution: received fax, system removed, plan to be submitted prior to reinstallation.
Construction/Loadline › Hull
Issued 24 July 2003 Resolved
Observed heavy pitting in way of the bow thruster tunnel. Upper surface of the tunnel adjacent to the thruster blades. Make permenent repairs prior to launching. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 31 July 2003
Resolution: Installation of new thruster tunnel completed in kind. Observed successful air test of weldments.
Deck/Cargo › Holds/Tanks
Issued 24 July 2003 Resolved
Hatch cover to waste lube oil tank (cargo) was not secured. Make the tank watertight. A minimum of 4 bolts and gasket. LEGACY COMPONENT DESC: Hatch Cover
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 July 2003
Resolution: Installed a new hatch cover, gasket, and 8 bolts for a watertight seal.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 24 July 2003 Resolved
Provide report attesting to satisfactory testing of the cargo transfer system in accordance with 35.35-70. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2003
Construction/Loadline › Hull
Issued 24 July 2003 Resolved
Provide 30 year mid-body gauging reort as required by 46 CFR 31.10-21a. Conduct same during the next ISE Hull exam. LEGACY COMPONENT DESC: Hull Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 August 2004
Resolved 6 October 2003
Resolution: Completed hull gauging.
Construction/Loadline
Issued 27 July 2001 Resolved
Barge is to under go mid-body 30 year hull gauging as required by 46 CFR 31.10-21a at the next dry-docking.
Condition: Unknown
Due 31 July 2003
Resolved 6 October 2003
Fire Fighting
Issued 31 July 1998 Resolved
No later than 31 July 1998, provide fire extinguisher brackets for portablefire extinguishers as means of securing them during transit.
Condition: Unknown
Due 31 July 1998
Resolved 1 August 1998
Construction/Loadline
Issued 31 July 1998 Resolved
No later than 31 July 1998, provide mechanical hatch cover closure devices for all void space hatch covers. At the time of the inspection, the hatch covers were being overhauled.
Condition: Unknown
Due 31 July 1998
Resolved 1 August 1998
Construction/Loadline
Issued 31 July 1998 Resolved
No later than 31 July 1998, provide sufficient gasket material for void space hatch covers.
Condition: Unknown
Due 31 July 1998
Resolved 1 August 1998
Deck/Cargo
Issued 30 September 1997 Resolved
HYDRO-TEST CARGO PIPING AND CARGO HOSE PRIOR TO CONDUCTING CARGO OPERATIONS.
Condition: Unknown
Due 30 September 1997
Resolved 16 October 1997
Documentation
Issued 30 September 1997 Resolved
PROVIDE USCG APPROVED VESSEL RESPONSE PLAN PRIOR TO CARGO OPERATIONS.
Condition: Unknown
Due 30 September 1997
Resolved 28 October 1997
Construction/Loadline
Issued 26 June 1996 Resolved
Properly repair the forward hatch prior to placing the vessel in service.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Accommodation/Occupational Safety
Issued 26 June 1996 Resolved
Properly repair the two vents for the forward rake space prior to placing the vessel in service.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Construction/Loadline
Issued 26 June 1996 Resolved
Properly repair the aft rake space hatch handle prior to placing the vesselin service.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Construction/Loadline
Issued 26 June 1996 Resolved
Properly repair the starboard side center cleat prior to placing the vesselin service.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Fire Fighting
Issued 26 June 1996 Resolved
Properly service the two fire extinguishers prior to placing the vessel in service.
Condition: Unknown
Due 26 June 1996
Resolved 26 June 1996
Deck/Cargo
Issued 23 October 1995 Resolved
Prior to transfering cargo, properly hydrostatic test the cargo piping to the MAWP of the cargo pump.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995
Deck/Cargo
Issued 23 October 1995 Resolved
Prior to transfering cargo, properly hydrostatict test all transfer hoses.
Condition: Unknown
Due 15 November 1995
Resolved 9 November 1995
Deck/Cargo
Issued 23 October 1995 Resolved
Prior to transfering cargo, properly repack the three main deck reach rods.
Condition: Unknown
Due 23 October 1995
Resolved 23 October 1995

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.

Maury does not score, rate, or grade vessels. What Maury does not do · Glossary · Correct a record.