← All vessels
NYLSA
NYLSA is a 1956 freight ship. The Coast Guard has recorded 20 inspections since 1984, most recently in September 1996, along with 39 deficiencies and 1 operational control.
Records from 1984 to 1996. Most recent: operational control imposed, 30 September 1996.
- Built
- 1956
- Last inspected
- 30 September 1996
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 39 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
Inspections, by type
…with no type recorded6
Years with a record
13 calendar years (1984–1996)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 30 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it36 - Regulatory (Subpart C or D), Net Ton
44 - Regulatory (Subpart C or D), Gross Ton
44 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
30 September 1996
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 396361
8 April 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 109220
4 December 1995
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1387896
13 October 1994
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1462411
5 November 1993
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1405451
12 October 1993
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1409038
14 October 1992
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1407088
27 November 1991
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1250699
28 October 1991
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 939612
25 October 1990
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 917147
20 October 1989
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1195204
31 October 1988
COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1202195
27 August 1987
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1309487
6 October 1986
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1317752
3 October 1986
Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1317750
3 October 1985
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 989188
17 December 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1283852
19 October 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 974715
19 October 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1282665
5 October 1984
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1286814
Deficiency record · 39
Documentation
Issued 30 September 1996
Resolved
Provide one capt and one licensed mate (required)
Documentation
Issued 30 September 1996
Resolved
Provide medical certificates for all crew onboard
Documentation
Issued 30 September 1996
Resolved
PROVIDE SHIP'S REGISTRY PRIOR TO DEPARTURE.
Fire Fighting
Issued 30 September 1996
Resolved
Provide two additional BII fire extinguishers properly mounted at engine room.
Electrical
Issued 30 September 1996
Resolved
Provide different circuits for anchor lights and mast light.
Construction/Loadline
Issued 30 September 1996
Resolved
INSTALL FIXED BILGE PIPING FROM EACH COMPARTMENT TO A COMMON MANIFOLD/PUMP ENGINE ROOM.
Lifesaving
Issued 30 September 1996
Resolved
Provide proper anchor and anchor line for vsl.
Engineering
Issued 30 September 1996
Resolved
Provide "discharge of oil prohibited" placard for engine room.
Electrical
Issued 30 September 1996
Resolved
Provide proper light bulbs for navigation lights (Maritime bulbs vice housebulbs)
Electrical
Issued 30 September 1996
Resolved
Provide proper cover/box for batteries at engine room.
Navigation
Issued 30 September 1996
Resolved
Provide the following publications: 1)Nav rules_x001C_ 2)Tide and tidal tables_x001C_ 3)light list_x001C_ 4)US Coast Pilot
Engineering
Issued 30 September 1996
Resolved
Provide fuel tanks capacity and transfer procedures if more than 10,500 gal
Lifesaving
Issued 30 September 1996
Resolved
Provide two ring buoys with proper retroflective tape, 50' line and waterlights
Documentation
Issued 30 September 1996
Resolved
Provide a garbage disposal book with proper entries.
Lifesaving
Issued 30 September 1996
Resolved
Properly install a hydrostatic release for liferaft.
Documentation
Issued 30 September 1996
Resolved
Provide a crew list for personnel onboard
Lifesaving
Issued 30 September 1996
Resolved
Provide three additional red flares and three add smoke signals.
Navigation
Issued 30 September 1996
Resolved
Provide a current deviation table for vsl.
Engineering
Issued 30 September 1996
Resolved
Provide flame screens for fuel vents.
Fire Fighting
Issued 13 October 1994
Resolved
1 ADDITIONAL B-II EXTINGUISHER REQUIRED TO MEET REQUIRED COMPLEMENT.
Electrical
Issued 5 November 1993
Resolved
USE PROPER CONECTING DEVICE FOR BILGE PUMP FLOAT SWITCH PIGTAIL TO SHIP SUPPLY WIRING.
Fire Fighting
Issued 5 November 1993
Resolved
PROVIDE CLOSURE DEVICES FOR CARGO TANK VENTS TO PREVENT EXCAPE OF CO2 MEDIUM.
Navigation
Issued 5 November 1993
Resolved
PROVIDE UPDATED COMPASS DEVIATION TABLE.
Fire Fighting
Issued 5 November 1993
Resolved
PROVIDE LABELS FOR CO2 SELECTOR VALVES TO INDICATE WHICH CARGO TANKS THE SERVE.
Engineering
Issued 14 October 1992
Resolved
SHOW PROPER OPERATION OF MAIN ENGINE DRIVE OIL PRESSURE GUAGE.
Fire Fighting
Issued 14 October 1992
Resolved
PROVIDE PROPER FITTING BRACKET FOR B-II CO2 PORTABLE FIRE EXTINGUISHER.
Documentation
Issued 14 October 1992
Resolved
VESSEL MUST HAVE DOCUMENTATION NUMBER PERMANTLY AFFIXED TO MAIN BEAM OF VESSEL.
Deck/Cargo
Issued 14 October 1992
Resolved
REPAIR/REPLACE HOUSING FOR NO2 PORT CARGO TANK VENT FLAME SCREEN.
Fire Fighting
Issued 14 October 1992
Resolved
NAME OF VESSEL MUST BE PERMANTLY AFFIXED TO FIRE AXE.
Construction/Loadline
Issued 19 October 1984
Resolved
REPLACE BROKEN GLASS WINDOW ON PORT SIDE DOOR OF THE PILOT HOUSE.
Electrical
Issued 19 October 1984
Resolved
REPLACE BROKEN CIRUIT BREAKER NUMBER (9) IN THE PILOT HOUSE OR REPLACE ENTIRE CIRCUIT BREAKER PANEL.
Construction/Loadline
Issued 19 October 1984
Resolved
REPLACE BROKEN GLASS WINDOW ON PORT SIDE DOOR OF THE PILOT HOUSE.
Electrical
Issued 19 October 1984
Resolved
REPLACE BROKEN CIRCUIT BREAKER NUMBER 9 IN THE PILOT HOUSE OR REPLACE ENTIRE CIRCUIT BREAKER PANEL.
Deck/Cargo
Issued 5 October 1984
Resolved
REPLACE COVER ON LISTER PUMP CLUTCH.
Electrical
Issued 5 October 1984
Resolved
REPLACE BROKEN CIRCUT BREAKER LEFT CIDE NUMBER 9 IN PILOT HOUSE DISTRIBUTION PANEL.
Construction/Loadline
Issued 5 October 1984
Resolved
REPLACE PORT HOLE GLASS ON THE PORT SIDE OF THE PILOT HOUSE.
Engineering
Issued 5 October 1984
Resolved
REPLACE VALUE HANDLE TO VALUE FOR STBD REMOTE FUEL SHUT OFF.
Electrical
Issued 5 October 1984
Resolved
REPLACE GLOBE AND GUARD ON LIGHT IN AFT STBD CORNER OF ENGINE ROOM.
Engineering
Issued 5 October 1984
Resolved
PROVIDE A GUARD FOR THE BILGE/FIRE PUMP DRIVE BELTS IN ENGINE ROOM.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.