Records from 1985 to 2007. Most recent: inspection, 2 July 2007.
Documentation record
Registered dimensions (L × B × D)36.0 ft × 9.8 ft × 3.7 ft
Registered tonnagegross 14 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderJOHN B LAUGHEAD · BRENT, KY, UNITED STATES · built 1956
Hull materialSteel
PropulsionGasoline Engine
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCINCINNATI, OH
Trade endorsementsCoastwise, unrestricted
DocumentationNo Operation - PM · issued 10 April 2008 · expires 31 May 2009
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Regulatory (Subpart C or D), Net Ton
14 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
2 July 2007
Administrative Inspection
Administrative · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2980878
20 October 2001
COI Inspection · Hull Examination
Physical examination · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 1454983
30 April 1998
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1124719
10 February 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1103576
22 January 1997
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1099864
31 July 1996
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1095504
2 October 1995
COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1193547
11 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1193741
11 May 1995
Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1193548
6 May 1992
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1264347
4 May 1992
Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1262393
1 May 1992
Hull Examination · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 946474
18 April 1990
Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1211682
7 June 1989
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 892743
12 July 1988
Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1342729
28 July 1987
Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1331775
8 May 1987
Hull Examination · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1332292
6 June 1986
Re-Inspection
Physical examination · MSO CINCINNATI · Activity 1299639
5 July 1985
Type not recorded
No type recorded · MSO CINCINNATI · Activity 1287314
Engineering
Issued 31 July 1996
Resolved
REPLACE WELL DECK FUEL TANK VENT FLAME SCREEN WITH ACCEPTABLE MATERIAL.
Condition: Unknown
Due 31 July 1996
Resolved 31 July 1996
Engineering
Issued 4 May 1992
Resolved
Replace engine flame arrestor with an arrestor that meets the approval specified by 46 CFR 182.15-7(b) prior to the compliance date.
Condition: Unknown
Due 4 May 1992
Resolved 4 May 1992
Deck/Cargo
Issued 7 June 1989
Resolved
REPAIR LOOSE CLEAT ON MAIN DECK PORT SIDE.
Condition: Unknown
Due 7 June 1989
Resolved 7 June 1989
Documentation
Issued 8 May 1987
Resolved
PROVIDE A CURRENT DOCUMENT SHOWING THE PROPER ADDRESS FOR THE VESSEL OWNER.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Engineering
Issued 6 June 1986
Resolved
PROPERLY AND ADEQUATELY INSULATE THE VESSEL'S EXHAUST PIPING. THIS ITEM ISTO BE COMPLETED PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Fire Fighting
Issued 6 June 1986
Resolved
PROVIDE PROPER BRACKETS FOR ALL ONBOARD PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Engineering
Issued 6 June 1986
Resolved
REPLACE THE WATER MANIFOLD OR PROPERLY REPAIR THE LEAK. THIS ITEM IS TO BECOMPLETED PRIOR TO OPERATING THE VESSEL.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986
Lifesaving
Issued 6 June 1986
Resolved
PROVIDE NINE (09) ADDITIONAL ADULT LIFE JACKETS. THIS ITEM IS TO BE COM- PLETED PRIOR TO PLACING THE VESSEL IN SERVICE.
Condition: Unknown
Due 6 June 1986
Resolved 6 June 1986