MAURY USCG vessel records Sign in
← All vessels

EXPLORER

EXPLORER is a 1995 passenger vessel (inspected). The Coast Guard has recorded 59 inspections since 1995, most recently in March 2026, along with 254 deficiencies and 2 operational controls.

Records from 1995 to 2026. Most recent: inspection, 6 March 2026.

Built
1995
Last inspected
6 March 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP9870
431692
Flag
UNITED STATES
367647920
Maury page id
psix-431692

Inspections, by type

…with no type recorded3
Years with a record 27 calendar years (1995–2026)
The 59 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)77.0 ft × 21.8 ft × 4.5 ft
Registered tonnagegross 50 / net 40
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBEAVER SHIPWORKS INC · BIDDEFORD, ME, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portORANGE BEACH, AL
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 25 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Simplified, Gross Ton
55 - Displacement, Gross Ton
40 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP9870MMSI 367647920 · active · compulsorily equipped · granted 31 January 2025, expires 31 January 2035
WDH7416MMSI 367647920 · expired · compulsorily equipped · granted 22 November 2014, cancelled 25 January 2025
WDE9639MMSI 368496000 · expired · compulsorily equipped · granted 22 July 2009, cancelled 21 September 2019
WCY8355MMSI not assigned · expired · compulsorily equipped · granted 20 January 1999, cancelled 28 March 2009
WCV5878MMSI not assigned · expired · voluntarily equipped · granted 30 November 1995, cancelled 4 February 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 59

6 March 2026 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8320871
29 April 2025 COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8108398
2 December 2024 Administrative Inspection · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8041858
6 May 2024 Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7907661
8 March 2023 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7647826
13 February 2023 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7636137
14 December 2022 Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7631317
9 November 2022 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7605902
29 July 2022 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7519786
8 November 2021 Administrative Inspection · In-Service Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7349663
29 April 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7185986
8 March 2021 Hull Examination · Deficiency Check · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7151939
29 April 2020 Administrative Inspection · COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6945555
6 December 2019 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6868834
18 September 2019 In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6814771
18 March 2019 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6644843
6 February 2019 Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6621288
12 April 2018 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6390447
24 July 2017 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6220582
27 March 2017 DAPI Audit · Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6112129
10 February 2017 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6086223
24 May 2016 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5885910
18 April 2016 Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5857096
15 March 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5834050
21 October 2015 Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5747537
27 January 2011 Examination of Repairs
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3973300
10 March 2010 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3693264
21 July 2009 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3541739
14 November 2008 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3363208
15 September 2008 Deficiency Check · Plan Review "T" Boat
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3325426
26 August 2008 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3310351
18 April 2008 Deadweight Survey · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 3187033
25 January 2008 Hull Examination · Internal Structural Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3136140
8 August 2006 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2739915
11 October 2005 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2507396
11 March 2004 Deficiency Check · Re-Inspection · MARPOL Annex V Examination · Annual Inspection · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2022500
10 February 2003 Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1739298
17 January 2003 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1729946
27 December 2002 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 1724298
27 November 2002 Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1709583
18 September 2001 Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1450673
30 August 2001 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1457984
26 November 1999 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1421800
2 July 1999 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1086399
2 July 1999 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1345180
10 December 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 807457
10 December 1998 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1400896
18 August 1998 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1461902
14 July 1998 MARPOL Annex V Examination · Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1434743
3 April 1998 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1392940
27 March 1998 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1123409
16 December 1997 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1117418
11 December 1997 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1120474
16 December 1996 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1094604
6 March 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 885629
5 February 1996 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1452137
16 December 1995 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 884254
16 December 1995 Initial Construction-Excluding Oversight · Initial Certification · MARPOL Annex V Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1191783
7 November 1995 Inclining Experiment
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 884255

Deficiency record · 254

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 March 2026 Resolved
An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided... MI observed 115 adult life jackets and 11 child size life jackets in satisfactory condition on board. Vessel passenger count shall not exceed 115 and shall have appropriately sized life jackets for all passengers on board. 46 CFR 180.71
Action required: 705 - Other - as specified
Resolved 1 April 2026
Resolution: Vessel provided photographic evidence of new life jackets placed in service and properly labeled.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 March 2026 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. MI observed degraded retro-reflective tape and missing cork on one of vessel's ring buoy. Vessel shall renew the retro-reflective tape. 46 CFR 180.70 (a)(3)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 April 2026
Resolution: Vessel provided photographic evidence of ring buoy repaired. All sat.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 6 March 2026 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. MI observed signage for upper deck was degraded. Vessel shall renew signage. 46 CFR 185.602 (g)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 April 2026
Resolution: Vessel provided evidence of signage repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 April 2025 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than buoyancy compartments, under all practical conditions. Bilge pickup in bunkroom inoperable. 46 CFR 182.25-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 30 April 2025
Resolution: Witnessed successful operation of the bilge pick up in the bunkroom.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2025 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements of the hull of which it is installed and capable of operating at constant marine load. Turbo filter missing on port-side engine. 46 CFR 182.05-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 2 May 2025
Resolution: Turbo filter satisfactorily replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2025 Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Steering linkage missing nut and secondary nut backed off. 46 CFR 182.30-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 30 April 2025
Resolution: Examined steering linkage and observed both nuts reinstalled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 April 2025 Resolved
Non-conducting mats or grating shall be provided on deck in front and rear of switchboards. No mat provided in front of switchboard in machinery space. 46 CFR 183.10-15(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 2 May 2025
Resolution: Received photo of new mat placed in front of switchboard.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 April 2025 Resolved
The marine inspector shall require that all unsafe practices and hazardous situations be corrected. Batteries behind operating station are not secured and battery for port-side generator is not contained in box. 46 CFR 176.25-50
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 2 May 2025
Resolution: Battery for generator now in box, and batteries behind operating station are now secured by straps.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 29 April 2025 Resolved
The marine inspector shall require that all unsafe practices and hazardous situations be corrected. Flooring in port-side entrance of salon is folded up, creating a potential tripping hazard.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2025
Resolved 2 May 2025
Resolution: Received photo of mat placed over folded up flooring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2025 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel is reduced to carrying 128 passengers until a sufficient amount of PFDs can be provided for the total persons on board per the vessel's COI. 46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 May 2025
Resolution: Sufficient amount of lifejackets were provided for total persons on board vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 April 2025 Resolved
A number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided, or such greater number as necessary to provide a life jacket for each person being carried. Vessel is reduced to carrying 9 child passengers until a sufficient amount of PFDs can be provided for the total number of child passengers on board per the vessel's COI. 46 CFR 180.71(b)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 May 2025
Resolution: Sufficient amount of lifejackets were provided for total children on board vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2024 Resolved
46 CFR 180.75 Each life jacket carried on a vessel on oceans, coastwise, or Great Lakes route, must have a life jacket light. 20 of the 103 life jackets on board were missing lights. Attach lights to 20 life jackets. Passenger count will be limited to 83 until the lights are on all life jackets.
Action required: 705 - Other - as specified
Resolved 9 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2024 Resolved
46 CFR 180.71 An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provide. Vessel is certificated for up to 153 total persons on board. Vessel must have 153 adult size life jackets and 16 child size life jackets. Vessel currently has 103 adult and 11 child. Passenger count is limited to the number of life jackets on board.
Action required: 705 - Other - as specified
Resolved 20 June 2024
Resolution: Received photo evidence of additional 50 adult and 5 child life jackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2024 Resolved
46 CFR 185.604 (f) The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Life jacket stowage area is labeled only for 103 adult and 11 child. Once vessel gets additional life jackets on board, update these numbers to 153 adult and 16 child.
Action required: 705 - Other - as specified
Resolved 20 June 2024
Resolution: Received photo evidence of appropriate labels for adult and child life jackets (additional storage below deck)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 March 2023 Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel to replace 8 life jacekts onboard due to condition. Vessel limited to carry only 95 total persons onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 April 2023
Resolution: Received photograph of 09 lifejackets onboard the vessel.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 1 August 2022 Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel. Vessel had no alcohol swabs on board. Provide enough alcohol swabs to test all members that could be directly involved in a Serious Marine Incident. Vessel is limited to an operating area that is within 2 hours of ability for chemical testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 August 2022
Resolution: Received objective evidence of new alcohol testing swabs.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 August 2022 Resolved
The maximum number of passengers allowed on an upper deck must be indicated by durable marking of at least 1" numbers and letters at the entranceway to that deck. Max passengers signage was missing. Relabel.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 8 August 2022
Resolution: Received objective evidence of new signage posted limiting customers on upper deck.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 August 2022 Resolved
A vessel must carry a first aid kit under approval 160.041 or equivalent. Aspirin in kit is expired. Replace with un-expired aspirin.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 3 August 2022
Resolution: Received photographic evidence that the aspirin was replaced.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 August 2022 Resolved
Provision must be made for closure of all supply ducts and exhaust ducts for a space protected by a fixed system starboard closure broken make provision for securing ventilation. 46 CFR 182.65(h)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2022
Resolution: C channel was reinstalled during the inspection and verified operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 August 2022 Resolved
Each Survival craft must be secured to the vessel with a float free link. Tag with breaking strength unavailable provide evidence that float free link is suitable for installation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 August 2022
Resolution: Objective evidence was received that the weak link was purchased and installed satisfactorily.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 1 August 2022 Resolved
Each item of survival craft must be of good quality and efficient for the purpose it is intended to serve. Life float was missing vessel name and solas tape is worn. Label floats and ensure retro-reflective solas tape is renewed.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 3 August 2022
Resolution: Received photographic evidence that the Solas tape was replaced and floats were properly labeled.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 1 August 2022 Resolved
Fire detection must be installed in compliance with 181.400 through 181.420. Vessel is missing fire detector in accommodation space. Replace missing detector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 8 August 2022
Resolution: Received documentary evidence of new smoke detector replaced and installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2022 Resolved
All electrical equipment and circuits must be clearly marked and identified. Breaker panel in the engine room is missing labels. Identify supplied equipment and label.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2022
Resolved 29 August 2022
Resolution: Received objective evidence of labeled pannel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 March 2021 Resolved
Replace wasted strainers on lazarette and accommodation space bilge suction inlets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 April 2021
Resolution: New suction strainer installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2021 Resolved
Replace wasted hydraulic capstan mounted on forepeak gunwale/bulwark and associated piping/flexible tubing/couplings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2021
Resolved 12 April 2021
Resolution: Unused hydraulic system removed to the satisfaction of the OCMI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 March 2021 Resolved
Repair damaged/wasted exhaust piping in lazarette. Submit an acceptable repair proposal to the OCMI prior to beginning repairs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2021
Resolution: Pictures submitted as objective evidence for exhaust repair. Uploaded to documents section.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 8 March 2021 Resolved
Replace wasted ladder in forepeak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2021
Resolved 2 April 2021
Resolution: New ladder satisfactorily installed. Pictures uploaded into the documents section.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 March 2021 Resolved
Provide means to secure reach rod for bilge suction in forepeak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2021
Resolved 2 April 2021
Resolution: Reach rod secured as originally installed. Pictures uploaded into the documents section.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 March 2021 Resolved
Provide photo of clean and operable bilge suction in forepeak.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 April 2021
Resolution: Pictures uploaded into the documents section.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 12 May 2020 Resolved
Vessel Captain did not have supervisor training per vessel DAPI program. provide evidence captain has completed supervisor training.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2020
Resolved 26 May 2020
Resolution: Submitted photo of certificate showing completion of training
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 12 May 2020 Resolved
Vessel did not have full compliment of current first aid kit inventory. Provide current advil, eye wash, ammonia inhalants, and burn gel or replace with a new kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2020
Resolved 15 May 2020
Resolution: Recieved photos of current inventory
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 12 May 2020 Resolved
Vessel did not have proper logs for maintenance of life saving and fire fighting equipment. Provide evidence of vessel crew logging maintenance of equipment.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2020
Resolved 18 May 2020
Resolution: recieved pictures, all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 12 May 2020 Resolved
Vessels life ring aft of pilot house was missing the bung plug and the approval number series from Q Spec/manufacturer. Repair and provide information regarding approval series or replace with new and approved type.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2020
Resolved 19 May 2020
Resolution: Recieved pictures of lifering with proper labeling and in proper condition
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 May 2020 Resolved
Vessels battery charger did not have a cover on top to prevent debris or liquid from entering in. If out of service, remove, or install cover on top of battery charger.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2020
Resolved 15 May 2020
Resolution: Recieved photos, all sat
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 September 2019 Resolved
Outboard vertical support beam located in the tank room was found to be missing a section located approximately 1 foot from the bottom of the beam. Vessel O/O must submit a repair plan prior to commencing repairs.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 6 December 2019
Resolved 9 December 2019
Resolution: Replaced.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 25 April 2019 Resolved
US Coast Pilot, CG Light List, Tide/Currents, and Navigational charts are out of date. Provide updated charts and publications.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2019
Resolution: Provided updated publications
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 25 April 2019 Resolved
Port side MSD valve not locked out. Secure valve to prevent discharge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2019
Resolution: MSD Valve locked
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2019 Resolved
Generator missing sign verifying derated capacity. Provide sign showing generator has been derated.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2019
Resolution: Generator sign provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2019 Resolved
Small battery installation missing cover. Replace cover for battery box.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2019
Resolution: Battery cover provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 April 2019 Resolved
Switch for potable water pump missing cover. Replace cover for switch.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2019
Resolution: Cover provided for water pump switch.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 April 2018 Resolved
Buoyant line was wasted and needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 10 May 2018
Resolution: Buoyant Line Replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 19 April 2018 Resolved
Bracket was too large for fire extinguisher, replace bracket with approved bracket.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 10 May 2018
Resolution: Bracket Replaced.
Electrical › Electric Supply System (service) › Battery Charger
Issued 19 April 2018 Resolved
Battery charger was open on top for venting and was missing a drip shield. Provide drip proof cover for battery charger.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 10 May 2018
Resolution: Drip Shield was installed.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 19 April 2018 Resolved
Circuit breaker was found with openings, provide blanks for both panels on the bridge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 10 May 2018
Resolution: Blanks provided.
Engineering › Steering Gear System › Rudder
Issued 12 April 2018 Resolved
Port steering gear rudder post support was found wasted and cracked. Provide repair proposal and repair to the satisfaction of attending marine inspector. Conduct visual inspection prior to getting underway and log inspection.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2018
Resolved 10 May 2018
Resolution: Replaced support with new piece. Operational test satified.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 May 2017 Resolved
Lifeline needs to be attached around the body of the life buoy IAW 46 CFR 180.70.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2017
Resolved 1 June 2017
Resolution: Life line was attached around the body of the life bouy.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 May 2017 Resolved
Life float water light tethers need to be at least 18’ long IAW 46 CFR 180.150.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 5 June 2017
Resolution: Life lines for water lights were at least 18 feet.
Lifesaving › Lifefloat › Lifeline
Issued 22 May 2017 Resolved
Life lines on all life floats need to be replaced IAW 46CFR 180.150.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 1 June 2017
Resolution: Life lines on all life floats were replaced.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 22 May 2017 Resolved
Port forward water light and starboard aft floating water light for life floats have expired batteries IAW 46 CFR 180.150.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 24 July 2017
Resolution: New batteries provided.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 May 2017 Resolved
Repair or replace starboard navigation light meeting UL 1104 (All lights need to meet UL 1104) IAW 46 CFR 183.420.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2017
Resolved 1 June 2017
Resolution: Repaced all nav lights with UL 1104 lights.
Accommodation/Occupational Safety › Potable Water System › General
Issued 22 May 2017 Resolved
Potable water tanks need to have caps on fill pipes IAW 46 CFR 176.818
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 1 June 2017
Resolution: Potable water tanks had caps on fill pipes.
Fire Fighting › Fire Pumps › Pressure
Issued 22 May 2017 Resolved
Show proper operation of fire pump with pressure of at least 60 psi IAW 46 CFR 181.10-19(c).
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 22 May 2017
Resolution: Fire pump was operating correctly.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 22 May 2017 Resolved
Prove proper operation of emergency lighting in FWD berthing IAW 46 CFR 183.30.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 24 July 2017
Resolution: Demonstrated proper oeration of emergency lighting.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 22 May 2017 Resolved
Generator belt cover guards bolts need to be tightened and bracket fixed IAW 46 CFR 184.620.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 1 June 2017
Resolution: Guards wer fixed and properly in place.
Stability › Watertight Integrity › General
Issued 22 May 2017 Resolved
Ensure watertight hatch for anchor locker is watertight, tighten dogs IAW 46 CFR 179.360.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 1 June 2017
Resolution: Watertight hatch for anchor locker was watertight
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 22 May 2017 Resolved
Post EAP hotline phone number IAW 46 CFR 16.401.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 1 June 2017
Resolution: Posted EAP hotline number.
Communications › Radio Communications › VHF Radiotelephone
Issued 22 May 2017 Resolved
Install GPS to VHF-DSC and input MMSI IAW 46 CFR 184.502.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 1 June 2017
Resolution: GPS was installed to VHF-DSC and MMSI was inputted.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 22 May 2017 Resolved
Update Inland Navigation Rules IAW 46 CFR 184.420.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 1 June 2017
Resolution: Inland Navigation Rules was updated.
Lifesaving › Lifefloat › Painter
Issued 22 May 2017 Resolved
Each life float painter line must be long enough that each life float can float without contacting any other life float in the group IAW 46 CFR 180.137.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 1 June 2017
Resolution: Life float painter lines were of a correct length.
Engineering › Steering Gear System › Rudder Stock
Issued 22 May 2017 Resolved
STBD rudder needs packing, tightened, and bolt missing at rudder post IAW 46 CFR 176.804.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 24 July 2017
Resolution: New bolts installed and rudder packed approrpriately.
Engineering › Diesel Engine (propulsion-direct drive) › Waste Heat Recovery
Issued 22 May 2017 Resolved
Port engine jacket water leak needs repaired IAW 46 CFR 176.804.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2017
Resolved 1 June 2017
Resolution: Verified that port jacket water leak was fixed.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 22 May 2017 Resolved
Have placard or written directions for generator amps, hertz, and volts gauges to work properly IAW 46 CFR 183.320.
Action required: 705 - Other - as specified
Due 22 June 2017
Resolved 24 July 2017
Resolution: Markings provided for generator.
Communications › Radio Communications › EPIRB
Issued 21 March 2016 Resolved
EPIRB battery was expired. Replace with new battery or new CAT 1 EPIRB. Vessel limited to 3NM of shore until EPIRB battery is fixed.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Replaced EPIRB
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 21 March 2016 Resolved
Vessel's SSB radio was not installed. Install SSB and have FCC tech add radio to station license and inspect radio. Provide report. Vessel is limited to 20NM of shore until SSB is operational.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Owner requested change in route to 20NM in order to eliminate the requirement for a MF or SSB radio.
Communications › Radio Communications › VHF Radiotelephone
Issued 21 March 2016 Resolved
Vessel had no bridge to bridge certificate or second VHF radio. Install VHF radio and have FCC tech issue a bridge to bridge certificate.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 May 2016
Resolved 24 May 2016
Resolution: Bridge to bridge certificate was on board.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 March 2016 Resolved
Emergency light in accommodation space was non operational. Repair or replace light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Emergency light operable.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 March 2016 Resolved
Door to the starboard panel box in pilot house was unable to be latched. Replace door or install latch
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Added latch.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 March 2016 Resolved
A dead ended wire was found aft of the port engine in a junction box without a cover. Remove wire or properly cap and enclose wire in junction box with cover.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Properly capped and in enclosed junction box.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 March 2016 Resolved
A dead ended wire was found fwd of STBD engine. Remove or properly cap and enclose in a junction box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Properly capped and in enclosed junction box.
Stability › Watertight Integrity › General
Issued 21 March 2016 Resolved
Two through hull fittings were found without a cap or anything on them aft of each engine. Properly cap holes to ensure watertightness.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Properly capped.
Deck/Cargo › Holds/Tanks › Hatch
Issued 21 March 2016 Resolved
Forward void hatch could not be opened without pry bar and once open the mechanics were loose. Make hatch operational as designed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: hatch operable.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 21 March 2016 Resolved
Panel boxes in engine room were not labeled. Label panel boxes and breakers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Panel box labeled.
Fire Fighting › Fire Hoses › Location
Issued 21 March 2016 Resolved
Fire hose not easily accessible. Container needs to be notched out for better stowage and removal.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Hose made readily accessible.
Engineering › Generator (propulsion/auxiliary-electric) › Wiring
Issued 21 March 2016 Resolved
The water cooler hose on the port generator was being chaffed. Replace hose and add chaffing gear to prevent future damage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Replaced hose.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 21 March 2016 Resolved
During operation, the port engine had excessive exhaust smoke coming from the air intake/circulation area. Repair and eliminate leaking exhaust smoke. Owner stated that diesel mechanics are working on issue.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Replaced parts to remove smoke.
Engineering › Bilge Water Management System › Pump
Issued 21 March 2016 Resolved
Automatic bilge pump in engine room needs light to come on in pilot house when bilge pump operates.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2016
Resolved 18 April 2016
Resolution: Verified operation.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 26 March 2010 Resolved
Tighten all deck rails.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2010
Resolved 6 April 2010
Construction/Loadline › Structures › Deck Plating
Issued 10 March 2010 Resolved
Complete repairs to main deck aft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2010
Resolved 6 April 2010
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 10 March 2010 Resolved
Paint vessel name on stern.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2010
Resolved 6 April 2010
Construction/Loadline › Structures › Deck Plating
Issued 10 March 2010 Resolved
Prove all deck hatches are watertight.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2010
Resolved 6 April 2010
Fire Fighting › Fire Pumps › Pressure
Issued 10 March 2010 Resolved
Prove proper operation of fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2010
Resolved 6 April 2010
Engineering › Sea-water System (primary cooling) › Piping
Issued 10 March 2010 Resolved
Properly mount seawater pump and support wiring.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2010
Resolved 6 April 2010
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 10 March 2010 Resolved
Double clamp starboard sewage line.
Action required: 705 - Other - as specified
Due 9 April 2010
Resolved 6 April 2010
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 21 July 2009 Resolved
Prove proper operation of vessels smoke detectors prior to operating.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 24 July 2009
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 21 July 2009 Resolved
Vessel is to remove the fuel and gas free the after diesel tank and secure all lines or effect permanent repairs to the supply/return lines prior to operating.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 24 July 2009
Resolution: O/O to make permanent repairs to fuel tank at next hull exam or gas free or remove it.
Stability › Watertight Integrity › General
Issued 21 July 2009 Resolved
All aft deck hatches are to be made watertight and hose tested in the presence of a CG Marine Inspector prior to operating.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 24 July 2009
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 21 July 2009 Resolved
Replace starboard generator fuel hose with approved type hose, not to exceed 30" in length of run, prior to operting.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 24 July 2009
Documentation › Certificates/Documents › FCC SSL
Issued 21 July 2009 Resolved
Provide valid FCC station license and safety certificate prior to operating beyond 1000' from shore.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 24 July 2009
Documentation › Logs/Records › Drug Test Records
Issued 21 July 2009 Resolved
Provide proof of enrollment for all vessel crew members in valid drug testing program prior to operating.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 24 July 2009
Communications › Audible Communications › Horn/Whistle
Issued 21 July 2009 Resolved
Repair and prove proper operating of vessels horn/whistle prior to operating.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 24 July 2009
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 21 July 2009 Resolved
Vessel shall provide logbook and properly log all record training and drills.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 24 July 2009
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 21 July 2009 Resolved
Excessive leaking of starboard shaft seal shall be corrected prior to operating.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 24 July 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 July 2009 Resolved
Properly install battery volt meter and remove wire nuts.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 24 July 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2009 Resolved
Remove temporary connections to the starboard engine compartment exhaust fan and make permanent connections.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 24 July 2009
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 21 July 2009 Resolved
Properly support MSD lines in engine compartment.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 24 July 2009
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 21 July 2009 Resolved
Provide securing device for port MSD overboard discharge valve and ensure that it is secured while inside of 3 NM prior to operating.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 24 July 2009
Engineering › Bilge Water Management System › Hose
Issued 21 July 2009 Resolved
Remove improper hoses for electrical submersible bilge pumps and provide proper hose. Additionally install double clamping IWO hose attachment to the sea valve.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 24 July 2009
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 July 2009 Resolved
Tighten all deck rails.
Action required: 705 - Other - as specified
Due 28 July 2009
Resolved 24 July 2009
Stability › Unintentional Flooding › General
Issued 21 July 2009 Resolved
Renew flotation for the starboard vent closure.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 24 July 2009
Electrical › Electric Supply System (service) › Battery Installation
Issued 21 July 2009 Resolved
Batteries under vessels control station shall be placed in appropriate battery boxes and secured.
Action required: 705 - Other - as specified
Due 28 July 2009
Resolved 24 July 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2009 Resolved
Household wiring for the constavolt shall be removed along with the alligator clips and system properly wired with approved marine wiring.
Action required: 705 - Other - as specified
Due 28 July 2009
Resolved 24 July 2009
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 21 July 2009 Resolved
Label CO2 discharge alarm in engine compartment.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 24 July 2009
Communications › Radio Communications › EPIRB
Issued 21 July 2009 Resolved
Provide valid EPIRB registration prior to operating.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 24 July 2009
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 21 July 2009 Resolved
Repair and prove proper operation of emergency light in vessels wheel house.
Action required: 705 - Other - as specified
Due 21 August 2009
Resolved 24 July 2009
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 21 July 2009 Resolved
Renew fuel fill access hatch in main cabin.
Action required: 705 - Other - as specified
Due 28 July 2009
Resolved 24 July 2009
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 21 July 2009 Resolved
Thirteen adult PFD's are to be provided with new retroreflective tape. Vessels passenger count temporarily reduced to 97 until corrected.
Action required: 705 - Other - as specified
Due 21 July 2009
Resolved 24 July 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 26 August 2008 Resolved
Prior to the carriage of passengers, all wiring and misc controls to the A/C system on the upper deck are to be removed. The A/C system can be returned to service when amended plans are submitted and approved.
Action required: 705 - Other - as specified
Due 27 September 2008
Resolved 15 September 2008
Resolution: Plan submitted and approved this date.
Engineering › Bilge Water Management System › Valve
Issued 26 August 2008 Resolved
Install skin valve for starboard side sub pump.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 August 2008
Resolved 26 August 2008
Stability › Incline Test › General
Issued 17 March 2008 Resolved
Conduct a Stability Test.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Stability › Intact Righting Energy › General
Issued 17 March 2008 Resolved
Install the draft marks correctly.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 June 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 11 October 2005 Resolved
Ensure vsl's electrical is IAW 46 CFR 183.
Due 15 December 2005
Resolved 17 March 2008
Resolution: All unused wiring removed. All wiring properly supported.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 11 October 2005 Resolved
Provide locks for MSD's.
Due 15 December 2005
Resolved 17 March 2008
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 11 October 2005 Resolved
Provide proper lettering and numbering of vsl name and hailing port on hull.
Due 15 December 2005
Resolved 17 March 2008
Construction/Loadline › Structures
Issued 25 March 2004 Resolved
Make all watertight bulkheads water tight (tank space). LEGACY COMPONENT DESC: Transverse Bulkhead
Due 9 April 2004
Resolved 14 April 2004
Resolution: Watertight blkd sealed properly.
Navigation › Collision/Grounding Avoidance
Issued 11 March 2004 Resolved
Replace all navigation lights with fixtures that meet UL 1104 standards. Vessel is restricted from night time operations and restricted visibility until corrected. LEGACY COMPONENT DESC: Navigation Lights
Due 9 April 2004
Resolved 14 April 2004
Resolution: All nav lights sat.
Operations/Management › Navigation Safety
Issued 11 March 2004 Resolved
Install one all-round white light at the highest point on vessel (anchor light) that meets UL 1104 standards. Vessel is restricted from night time operations and restricted visibility until corrected. LEGACY COMPONENT DESC: Requirements for Vessels at Anchor
Due 9 April 2004
Resolved 14 April 2004
Resolution: All around white light installed.
Electrical › Lighting (service)
Issued 11 March 2004 Resolved
Make all exterior light fixtures watertight. LEGACY COMPONENT DESC: Lighting Fixture
Due 9 April 2004
Resolved 14 April 2004
Resolution: Exterior lights removed.
Stability › Weathertight Integrity
Issued 11 March 2004 Resolved
Replace all broken windows on the bridge.
Due 9 April 2004
Resolved 14 April 2004
Resolution: Windows replaced.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 11 March 2004 Resolved
Make proper repairs to aft main deck railing. Passengers are restricted from the aft 4' of deck until corrected. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 9 April 2004
Resolved 11 October 2005
Engineering › Fuel Oil Service System
Issued 11 March 2004 Resolved
Make permanent and proper repairs to fuel vent at the tank/elbow (remove epoxy for further inspection). LEGACY COMPONENT DESC: Ventilation
Due 9 April 2004
Resolved 14 April 2004
Resolution: Elbow replaced.
Electrical › Electric Supply System (service)
Issued 11 March 2004 Resolved
Make permanent repairs to shore power pigtail prior to use. LEGACY COMPONENT DESC: Cable
Due 11 March 2004
Resolved 14 April 2004
Resolution: Removed land side shore tie.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Nozzle
Issued 11 March 2004 Resolved
Install discharge outlet for fixed CO2 system in engine room.
Due 9 April 2004
Resolved 17 March 2008
Engineering › Diesel Engine (propulsion-direct drive)
Issued 11 March 2004 Resolved
Make permanent repairs to centerline main diesel engine's port exhaust piping and port main diesel engine's inboard exhaust piping (minor leak). LEGACY COMPONENT DESC: Piping (exhaust)
Due 9 April 2004
Resolved 14 April 2004
Resolution: Exhaust leaks repaired.
Engineering › Fuel Oil Service System
Issued 11 March 2004 Resolved
Mark remote fuel shut off stations in at least one inch letters indicating purpose of valve and direction of operations. LEGACY COMPONENT DESC: Valve, Control
Due 9 April 2004
Resolved 14 April 2004
Resolution: Labeled.
Electrical › Electric Generation Source (service)
Issued 11 March 2004 Resolved
Make permanent repairs to generator (minor water leak). LEGACY COMPONENT DESC: Generator
Due 9 April 2004
Resolved 14 April 2004
Resolution: Water pump leak repaired.
Operations/Management › Drills/Instruction
Issued 11 March 2004 Resolved
Make vessel available for man overboard and fire drills.
Due 9 April 2004
Resolved 26 March 2004
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 March 2004 Resolved
Provide 6 adult lifejackets with lights. Vessel restricted from carrying no more than 100 persons until corrected.
Due 11 March 2004
Resolved 17 March 2008
Fire Fighting › Fire Hoses › Connections
Issued 11 March 2004 Resolved
Attach two nozzels approved by the Commandant or in accordance with 46 CFR 160.027 to fire hoses. LEGACY COMPONENT DESC: Connections
Due 9 April 2004
Resolved 17 March 2008
Fire Fighting › Fire Pumps
Issued 11 March 2004 Resolved
Prove proper operation of fire pumps (60 psi/50gpm).
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2004
Resolved 26 March 2004
Fire Fighting › Fire Pumps
Issued 11 March 2004 Resolved
Make permanent repairs to leaking fire main/bilge system; to include but not limited to aft fixed bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 April 2004
Resolved 26 March 2004
Engineering › Fuel Oil Service System
Issued 11 March 2004 Resolved
Replace fuel shutoff valve handles (3 aft). LEGACY COMPONENT DESC: Valve
Due 9 April 2004
Resolved 14 April 2004
Resolution: Valve handles replaced.
Stability › Watertight Integrity
Issued 11 March 2004 Resolved
Install proper deck covers in way of transmission hoisting access.
Due 9 April 2004
Resolved 14 April 2004
Resolution: Deck covers installed.
Communications › Visual Communication
Issued 11 March 2004 Resolved
Mark emergency exit in main cabin.
Due 9 April 2004
Resolved 14 April 2004
Resolution: Emergency exit marked properly.
Lifesaving › Launching Appliances › Padeye
Issued 11 March 2004 Resolved
Remove line securing padeyes and make permanent and proper repairs to hull in way of accommodation space.
Due 30 November 2004
Resolved 3 November 2005
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 11 March 2004 Resolved
Properly run shore tie cable from e/r to deck connection.
Due 9 April 2004
Resolved 17 March 2008
Stability › Watertight Integrity
Issued 11 March 2004 Resolved
Properly mount main deck aft door and replace door knob.
Due 9 April 2004
Resolved 14 April 2004
Resolution: Door and knob installed properly.
Deck/Cargo › Holds/Tanks
Issued 11 March 2004 Resolved
Install new hasp to e/r hatch cover. LEGACY COMPONENT DESC: Hatch
Due 9 April 2004
Resolved 14 April 2004
Resolution: New hasp installed.
Operations/Management › Drills/Instruction
Issued 11 March 2004 Resolved
Provide more suitable "hook" in order to recover/pull alongside man overboard (i.e. shepards crook). LEGACY COMPONENT DESC: Man Overboard Recovery
Due 9 April 2004
Resolved 14 April 2004
Resolution: New boat hook installed onboard.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 March 2004 Resolved
Create vessel preventative maintenace schedule to include, but not limited to fire fighting, lifesaving, steering, bridge, and other engine room systems (i.e. daily, weekly, monthly, semi-annually and annually) and submit for review & implement.
Due 26 April 2004
Resolved 25 January 2008
Construction/Loadline › Structures
Issued 11 March 2004 Resolved
Make permanent & proper repairs to transverse deck frame under main deck and above bilge in void #2. Vessel restricted to routes of limited coastwise no more than 20 miles from a harbor of safe refuge) until corrected. LEGACY COMPONENT DESC: Transverse Bulkhead
Due 26 April 2004
Resolved 14 April 2004
Resolution: Repairs made to hull.
Engineering › Bilge Water Management System
Issued 5 February 2003 Resolved
Label Bilge Manifold. LEGACY COMPONENT DESC: Manifold
Condition: Improper/Lack of Maintenance
Due 12 February 2003
Resolved 6 February 2003
Resolution: INSTALLED PLASTIC TAGS.
Fire Fighting › Fire Pumps
Issued 5 February 2003 Resolved
Repair fire pump or replace. LEGACY COMPONENT DESC: Pumpshaft
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: REPLACED AND TESTED - SAT.
Operations/Management
Issued 5 February 2003 Resolved
Provide a PMS schedule and a person in charge of the maintenance of machinery. LEGACY COMPONENT DESC: PMS
Condition: Improper/Lack of Maintenance
Due 12 February 2003
Resolved 10 February 2003
Resolution: RCVD FAX LETTER.
Engineering › Bilge Water Management System
Issued 5 February 2003 Resolved
Prove proper operation of bilge system by pumping each compartment out. LEGACY COMPONENT DESC: Pump
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: TESTESD ALL BILGE SUCTIONS - SAT.
Electrical › Lighting (service)
Issued 5 February 2003 Resolved
Provide a light cover for light in after steering compartment. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Improper/Lack of Maintenance
Due 12 February 2003
Resolved 6 February 2003
Resolution: REMOVED FIXTURE AND WIRING.
Fire Fighting › Fire Pumps
Issued 5 February 2003 Resolved
Provide a on/off switch for fire pump. LEGACY COMPONENT DESC: Arrangement
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: SWITCH INSTALLED ON BRIDGE.
Engineering › Fuel Oil Service System
Issued 5 February 2003 Resolved
Replace covers to the emergency fuel oil shut off valves. (1 in cabin & 1 on AFT deck) LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: INSTALLED PLASTIC TAGS.
Accommodation/Occupational Safety › Occupational Safety
Issued 5 February 2003 Resolved
Provide a safety shield around fire pump & pully. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 13 February 2003
Resolution: INSTALLED.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 5 February 2003 Resolved
Remove FRP temp patch on STBD engine, inboard exhaust pipe and repair as needed. LEGACY COMPONENT DESC: Exhaust pipe
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: NO REPAIR NEEDED.
Lifesaving › Buoyant Apparatus
Issued 5 February 2003 Resolved
Properly instal life floats, weak link, 100 ft sea painter, waterlight with 15' floatable line attached. Vessel name and capacity stenciled on each float. Each life float stack shall be attached to a weak link of the proper capacity. LEGACY COMPONENT DESC: Life floats
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: SEA PAINTERS INSTALLED ON EACH FLOAT - ALL SAT.
Stability › Severe Wind/Roll
Issued 5 February 2003 Resolved
Repair broken bridge windows. LEGACY COMPONENT DESC: Bridge windows
Condition: Damaged By Earlier Event
Due 5 March 2003
Resolved 6 February 2003
Resolution: WINDOWS REPLACED.
Lifesaving › Buoyant Apparatus
Issued 5 February 2003 Resolved
Replace life ring. Ensure 1 life ring has 60' of floatable line, waterlight with 6' line and corrosion resistant clip & proper vessel name. LEGACY COMPONENT DESC: Life ring
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: REPLACED RING.
Engineering › Bilge Water Management System
Issued 5 February 2003 Resolved
Label high bilge level alarms on bridge. LEGACY COMPONENT DESC: High Level Alarms
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: LABELED.
Electrical › Mast
Issued 5 February 2003 Resolved
Properly support mast light wiring. LEGACY COMPONENT DESC: Lightning Ground
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: INSTALLED METALLIC SUPPORTS.
Lifesaving › Lifejacket/PFD (General)
Issued 5 February 2003 Resolved
Post life jacket donning proceedures, emergency proceedures, waste management plan, emergency broadcast placard, oil pollution placard, and garbage placard. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: ALL POSTED.
Lifesaving
Issued 5 February 2003 Resolved
Properly outfit first-aid kit. LEGACY COMPONENT DESC: First aid kit
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: REPLACED FIRST AID KIT.
Lifesaving
Issued 5 February 2003 Resolved
Modify rescue platform to retrieve helpless person from water. LEGACY COMPONENT DESC: POB platform
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: ADDED 30" X 30" PLATFORM TO EXISTING LADDER.
Electrical › Electric Generation Source (emergency)
Issued 5 February 2003 Resolved
Properly install battery pack under console(battery box) LEGACY COMPONENT DESC: Wiring
Condition: Placed in Improper Service
Due 5 February 2003
Resolved 6 February 2003
Resolution: INSTALLED PLASTIC BATTERY BOX.
Electrical › Electric Generation Source (service)
Issued 5 February 2003 Resolved
Remove pigtails from under console. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: REMOVED.
Operations/Management › Drills/Instruction
Issued 5 February 2003 Resolved
Initiate crew training drill logs.
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: INITIATED.
Navigation › Piloting/Steering
Issued 5 February 2003 Resolved
Provide charts, excerpts of coast pilot and light list for local AOR. LEGACY COMPONENT DESC: Every thing IWO charts, pubs
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: PROVIDED.
Stability › Water on Deck
Issued 5 February 2003 Resolved
Install 6" combing in way of AFT weather door. LEGACY COMPONENT DESC: Combing
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: INSTALLED.
Operations/Management › Drills/Instruction
Issued 5 February 2003 Resolved
Complete person OVBD and fire drills. LEGACY COMPONENT DESC: All
Condition: Improper/Lack of Maintenance
Due 5 February 2003
Resolved 6 February 2003
Resolution: DRILLS SAT. MAN OVERBOARD MUST BE CONDUCTED USING 2-WAY RADIOS DUE TO VISIBILITY FROM BRIDGE.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 5 February 2003 Resolved
REPAIR SSB RADIO. VESSEL RESTRICTED TO LIMITED COASTWISE LESS THAN 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL COMPLETED. LEGACY COMPONENT DESC: Radiotelephone Transveiver (2-4 MHz)
Condition: Improper/Lack of Maintenance
Due 12 February 2003
Resolved 17 March 2008
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 February 2003 Resolved
Repair all salt water leaks on the STBD exhaust system. LEGACY COMPONENT DESC: Exhaust
Condition: Improper/Lack of Maintenance
Due 3 February 2003
Resolved 5 February 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 February 2003 Resolved
Repair all leaks on the PORT salt water system going to exhaust. LEGACY COMPONENT DESC: Exhaust
Condition: Improper/Lack of Maintenance
Due 3 February 2003
Resolved 5 February 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 February 2003 Resolved
Provide exhaust lagging for all exhaust pipes. LEGACY COMPONENT DESC: Exhaust Lagging
Condition: Placed in Improper Service
Due 10 February 2003
Resolved 10 February 2003
Resolution: CLEARED VIA FAX DOCUMENTATION.
Stability › Watertight Integrity
Issued 3 February 2003 Resolved
Plug/cap through hull fitting IAW PORT engine, FWD. LEGACY COMPONENT DESC: Through hull fitting
Condition: Improper/Lack of Maintenance
Due 3 February 2003
Resolved 5 February 2003
Electrical › Electric Supply System (service)
Issued 3 February 2003 Resolved
Provide battery cell caps and covers for all batteries. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 3 February 2003
Resolved 5 February 2003
Lifesaving › Lifejacket/PFD (General)
Issued 3 February 2003 Resolved
Properly label all life preserver stowage areas. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 3 February 2003
Resolved 5 February 2003
Operations/Management
Issued 3 February 2003 Resolved
Complete 04 other outstanding CG-835's issued from MSO New York and MSD Fort Meyers. LEGACY COMPONENT DESC: Outstanding CG-835''''s
Condition: Improper/Lack of Maintenance
Due 3 February 2003
Resolved 5 February 2003
Fire Fighting › Fire Hydrants
Issued 3 February 2003 Resolved
Provide valve handle for STBD fire station. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 3 February 2003
Resolved 5 February 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 3 February 2003 Resolved
Label and prove proper operation of all emergency fuel oil shut-off valves. LEGACY COMPONENT DESC: Emergency fuel shut off
Condition: Improper/Lack of Maintenance
Due 3 February 2003
Resolved 5 February 2003
Electrical › Electric Supply System (service)
Issued 3 February 2003 Resolved
Make distribution panel IWO sink drip proof. (Protected from splashing water) LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 3 February 2003
Resolved 5 February 2003
Electrical › Electric Supply System (service)
Issued 3 February 2003 Resolved
Remove 220v pig tail from distribution panel IAW sink. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 3 February 2003
Resolved 6 February 2003
Resolution: Removed and plugged.
Electrical › Electric Supply System (service)
Issued 3 February 2003 Resolved
Install wet location outlets IWO STBD weather door. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 3 February 2003
Resolved 5 February 2003
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 27 December 2002 Resolved
Fixed CO2 system had no proof of annual inspection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 December 2002
Resolved 27 December 2002
Resolution: Owner provided proof that system had undergone annual inspection.
Engineering › Fuel Oil Service System
Issued 27 December 2002 Resolved
Shut off valves for fuel tank were not operable from outside the machinery space. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 December 2002
Resolved 27 December 2002
Resolution: Owner installed cable to operate valves from outside the space.
Engineering › Sea-water System (primary cooling)
Issued 27 December 2002 Resolved
Provide documentation which shows acceptance of flex hose used in vessel's raw water system. Hose must be replaced with ferrous metal piping if documentation cannot be provided to CG. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2003
Resolved 5 February 2003
Electrical › Electric Supply System (service)
Issued 27 November 2002 Resolved
Remount battery cut out switch. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 December 2002
Resolved 3 February 2003
Engineering
Issued 27 November 2002 Resolved
Panel hanging from wires. Remove/repair LEGACY COMPONENT DESC: Control Panal (micrprocessor)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 29 November 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 27 November 2002 Resolved
Fuel tank fwd sight glass missing guards. Connection at bottom of valve for priming generator loose Repair/remove provide proof that sight glass valve is self closing. LEGACY COMPONENT DESC: Gauge
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 27 December 2002
Resolution: Sight glass was removed by operator.
Construction/Loadline › Structures
Issued 27 November 2002 Resolved
Deck aft stbd corner leaks into laz. Repair/renew LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 5 February 2003
Construction/Loadline › Structures
Issued 27 November 2002 Resolved
Bilge penatration to lazzarett not sealed. Repair/renew. LEGACY COMPONENT DESC: Transverse Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 December 2002
Resolved 5 February 2003
Pollution Prevention/Response › Prevention Equipment
Issued 27 November 2002 Resolved
Overboard disharge valve frozen open. Repair/renew. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2002
Resolved 29 November 2002
Documentation
Issued 18 September 2001 Resolved
PROVIDE COPY OF FCC RADIOTELEPHONE SAFETY CERTIFICATE.-O/O STATES HE HAS RECENT ONE JUST MISPLACED AT PRESENT TIME.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Lifesaving
Issued 18 September 2001 Resolved
PROPERLY INSTALL WATERLIGHTS ON ALL 4 LIFEFLOATS
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Accommodation/Occupational Safety
Issued 18 September 2001 Resolved
PROVIDE AND PROPERLY POST EMRGENCY BROADCAST INFORMATION
Condition: Unknown
Due 27 September 2001
Resolved 7 November 2001
Lifesaving
Issued 18 September 2001 Resolved
Properly attach all 4 Lifefloats, Painter and grablines need to be correctly installed and water lights need to attached.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Engineering
Issued 18 September 2001 Resolved
PROPELY SUPPORT FUEL LINES IN ENGINE ROOM TO PREVENT EXCESSIVE VIBRATION AND SUBSEQUENT FAILURE OF FUEL LINE.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Electrical
Issued 18 September 2001 Resolved
PROVIDE GLOBES FOR ALL LIGHT FIXURES. GLOBES ARE MISSING FROM FIXTURES ON THE WX DECK AND IN THE PASSENGER BERTHING AREA.
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Lifesaving
Issued 18 September 2001 Resolved
PROPERLY INSTALL EPIRB ENSURE THAT HYDROSTATIC RELEASE IS CURRENT.
Condition: Unknown
Due 13 December 2001
Resolved 13 December 2001
Lifesaving
Issued 18 September 2001 Resolved
PROPERLY REPAIR EXHAUST PIPING AND TEST OIL FIRED FURNACE IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR PRIOR TO USING WITH PASSENGERS ABOARD. CURRENT CONDITION WOULD ALLOW THE BUILD UP OF CARBON MONOXIDE AND OTHER TOXIC GASES IN THE ENCLOSED PASSENGER COMPARTMENT.
Condition: Unknown
Due 13 December 2001
Resolved 13 December 2001
Fire Fighting
Issued 18 September 2001 Resolved
REPAIR FIRE DETECTION SYSTEM IN ENGING ROOM. HAVE DOCUMENTATION SHOWING PROPER OPERATION OF SYSTEM OR TEST IN THE PRESENCE CG INSPECTOR
Condition: Unknown
Due 5 October 2001
Resolved 5 October 2001
Engineering
Issued 30 August 2001 Resolved
LOCATE SOURCE OF, AND MAKE PERMANENT REPAIRS TO DIESEL FUEL LEAK IN ENGINE ROOM TO SATISFACTION OF ATTENDING MARINE INSPECTOR PRIOR TO RE-ISSUANCE OF COI.
Condition: Unknown
Due 31 August 2001
Resolved 31 August 2001
Construction/Loadline
Issued 10 December 1998 Resolved
Provide plans for any vessel modifications subject to prior CG OCMI approval and provide a laminate lay up schedule for the identified hull patches.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Documentation
Issued 10 December 1998 Resolved
As per NYCMI ltr 16711 dtd 10Dec98, vsl's COI is revoked pending credit drydock and outstanding deficiency completion. Vsl is not to operate with passengers for hire until COI is reissued. Since the vsl's temp COI was noton board, owner is to mail or deliver it to NYCMI no later than 17Dec98.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Lifesaving
Issued 10 December 1998 Resolved
Provide a 406 mhz epirb currently registered with NOAA as per 46 CFR 180.64.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Construction/Loadline
Issued 10 December 1998 Resolved
Provide required bilge alarms as per 46 CFR 182.530.
Condition: Unknown
Due 10 December 1998
Resolved 10 December 1998
Electrical
Issued 18 August 1998 Resolved
Remove wireties from deck lighting and provide suitable supporting bracketsfor same (port & stbd).
Condition: Unknown
Due 18 August 1998
Resolved 18 August 1998
Accommodation/Occupational Safety
Issued 18 August 1998 Resolved
Install handle on MSD overboard discharge valve on port side.
Condition: Unknown
Due 18 August 1998
Resolved 18 August 1998
Documentation
Issued 14 July 1998 Resolved
PROVIDE FCC STATION OPERATOR'S LICENSE BY FAX TO USCG OCMI
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Electrical
Issued 14 July 1998 Resolved
REWIRE LOUDHAILER SPEAKERS WITH APPROVED METHOD
Condition: Unknown
Due 14 July 1998
Resolved 16 July 1998
Accommodation/Occupational Safety
Issued 14 July 1998 Resolved
RENEW LADDER TREAD MATERIAL AS NEEDED
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Documentation
Issued 14 July 1998 Resolved
RECORD FIRE/MOB DRILLS IN SHIP'S LOG.
Condition: Unknown
Due 23 July 1998
Resolved 28 July 1998
Construction/Loadline
Issued 14 July 1998 Resolved
REMOVE STANDING WATER FROM AFT BILGES.
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Documentation
Issued 14 July 1998 Resolved
MOUNT STABILITY LETTER UNDER GLASS.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Navigation
Issued 14 July 1998 Resolved
PROVIDE CURRENT CHARTS, LIGHT LIST, TIDE TABLES, NOTICE TO MARINERS, COAST PILOT, COLREGS AND 46 CFR SUBCHAPTER 'T'.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Documentation
Issued 14 July 1998 Resolved
VESSEL TO CARRY NOT MORE THAN 80 TOTAL PERSONS UNTIL ADDITIONAL LIFEJACKETSARE PROVIDED AND INSPECTED BY CG MI.
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Documentation
Issued 14 July 1998 Resolved
PROVIDE PROOF OF CURRENT PRE-EMPLOYMENT DRUG TESTING AND FAX TO USCG OCMI
Condition: Unknown
Due 15 July 1998
Resolved 28 July 1998
Lifesaving
Issued 14 July 1998 Resolved
LABEL LIFEJACKETS WITH NEW VESSEL NAME
Condition: Unknown
Due 23 July 1998
Resolved 28 July 1998
Lifesaving
Issued 14 July 1998 Resolved
RENEW LIFEJACKET LIGHT BATTERIES AS NEC.
Condition: Unknown
Due 14 July 1998
Resolved 16 July 1998
Lifesaving
Issued 14 July 1998 Resolved
LABEL CHILD/ADULT LIFEJACKETS STOWAGE PROPERLY
Condition: Unknown
Due 23 July 1998
Resolved 28 July 1998
Lifesaving
Issued 14 July 1998 Resolved
REMOVE OIL FROM ENGINE ROOM BILGE
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Electrical
Issued 14 July 1998 Resolved
ATTACH ENGINE ROOM OVERHEAD CABLES WITH METAL STRAPS EVERY 24 INCHES
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Lifesaving
Issued 14 July 1998 Resolved
RENEW RETROREFLECTIVE TAPE AND WATERLIGHT BATTERIES ON RING BUOYS
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Engineering
Issued 14 July 1998 Resolved
INSTALL TURBO AIR SILENCERS ON PROPULSION ENGINES
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Electrical
Issued 14 July 1998 Resolved
RENEW FRESH WATER PUMP CONTROLLER IN LAZERETTE
Condition: Unknown
Due 23 July 1998
Resolved 28 July 1998
Navigation
Issued 14 July 1998 Resolved
DEMONSTRATE PROPER OPERATION OF AIR HORN
Condition: Unknown
Due 23 July 1998
Resolved 28 July 1998
Electrical
Issued 14 July 1998 Resolved
INSTALL BREAKER/PANEL BLANKS IN ENGINE ROOM AND PILOTHOUSE CONSOLE
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Documentation
Issued 14 July 1998 Resolved
PROVIDE ORIGINAL COD BY FAX TO USCG OCMI
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Fire Fighting
Issued 14 July 1998 Resolved
MOUNT BUNK ROOM FIRE EXTINGUISHER
Condition: Unknown
Due 14 July 1998
Resolved 16 July 1998
Electrical
Issued 14 July 1998 Resolved
INSTALL NEW CENTERLINE ENGINE BATTERIES
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Documentation
Issued 3 April 1998 Resolved
PRIOR TO OPERATING WITH MORE THAN 49 PASSENGERS AND MORE THAN 20 MILES FROMA HARBOR OF SAFE REFUGE, PROVIDE SATBILITY LETTER FOR VESSEL WITH ONLY TWO MDE'S INSTALLED OR RE-INSTALL CENTER THIRD MDE.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Navigation
Issued 11 December 1997 Resolved
PRIOR TO OPERATING NORTH OF MONTAUK POINT, NY, AND SOUTH OF OCEAN CITY, MARYLAND, PROVIDE UPDATED CHARTS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Fire Fighting
Issued 11 December 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVE PROPER OPERATION OF BOTH MAIN FIRE PUMPS(60 PSI @ 50 GPM)
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Lifesaving
Issued 11 December 1997 Resolved
PROVIDE ONE FLOAT LIGHT FOR FORWARD L/F.
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Engineering
Issued 11 December 1997 Resolved
REPAIR LEAKING FUEL PIPE FITTING ON FORWARD SIDE OF PORT FUEL TANK._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Fire Fighting
Issued 11 December 1997 Resolved
REPLACE PORT FIRE HOSE.
Condition: Unknown
Due 8 January 1998
Resolved 8 January 1998
Lifesaving
Issued 11 December 1997 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE APPROVED FIRST AID KIT OR EQUIVILENT.
Condition: Unknown
Due 11 December 1997
Resolved 11 December 1997
Fire Fighting
Issued 16 December 1996 Resolved
PRIOR TO OPERATING WITH PASSENGERS, PROVIDE MSO PHILADELPHIA WITH SERVICINGREPORT FOR FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 9 January 1997
Resolved 9 January 1997
Accommodation/Occupational Safety
Issued 16 December 1995 Resolved
PROVIDE COVERED METAL TRASH CANS IAW 46 CFR 177.30-7(d)_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Lifesaving
Issued 16 December 1995 Resolved
PROVIDE TWO ADDITIONAL RING BUOYS IAW 46 CFR 180.30_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Lifesaving
Issued 16 December 1995 Resolved
PROVIDE PADDLES FOR LIFE FLOATS IAW 46 CFR 180.15 _x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Lifesaving
Issued 16 December 1995 Resolved
PROVIDE LIGHTS FOR ALL PFDs IAW 46 CFR 180.25_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Lifesaving
Issued 16 December 1995 Resolved
PROVIDE 6 ADDITIONAL ADULT AND 1 ADDITIONAL CHILD PFD IAW 46 CFR 180.25_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Fire Fighting
Issued 16 December 1995 Resolved
PROVIDE ONE FIRE AXE IAW 46 CFR 181.35_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Fire Fighting
Issued 16 December 1995 Resolved
PROVIDE POWER FIRE PUMP TO MEET 46 CFR 181-10_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Fire Fighting
Issued 16 December 1995 Resolved
PROVIDE NOZZLES FOR FIRE HOSES IAW 46 CFR 181.15_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Engineering
Issued 16 December 1995 Resolved
RENEW MAIN ENGINE FUEL HOSES TO BE IAW 46 CFR 182.40-5 AND 46 CFR 56.60-25_x001C_CORRECT PRIO TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Accommodation/Occupational Safety
Issued 16 December 1995 Resolved
PROVIDE EMERGENCY LIGHTING FOR ACCOMADATION SPACE IAW 46 CFR 184.30-5_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Documentation
Issued 16 December 1995 Resolved
PROVIDE FCC SAFETY CERTIFICATE_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Lifesaving
Issued 16 December 1995 Resolved
CONDUCT EMERGENCY DRILLS FOR MARINE INSPECTOR_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Lifesaving
Issued 16 December 1995 Resolved
MOUNT EPIRB IAW 46 CFR 180.40-1_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Lifesaving
Issued 16 December 1995 Resolved
PROVIDE PFD STOWAGE MARKINGS IAW 46 CFR 185.30-10_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Accommodation/Occupational Safety
Issued 16 December 1995 Resolved
LABEL ACCESS LADDER TO UPPER DECK NO PASSENGERS ALLOWED IAW 46 CFR 185.30_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Lifesaving
Issued 16 December 1995 Resolved
LABEL EPIRB WITH VESSEL NAME IAW 46 CFR 185.30-30_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Accommodation/Occupational Safety
Issued 16 December 1995 Resolved
PROVIDE BUNK MATTRESSES IAW 46 CFR 177.30-7_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Navigation
Issued 16 December 1995 Resolved
PROVIDE CHARTS AND PUBS FOR OPERATING AREA_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Lifesaving
Issued 16 December 1995 Resolved
POST EMERGENCY CHECK OFF LISTS IAW 46 CFR 185.25-5_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Accommodation/Occupational Safety
Issued 16 December 1995 Resolved
PROVIDE LADDER FOR ACCOMADATION ESCAPE ROUTE_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Documentation
Issued 16 December 1995 Resolved
POST STABILITY LETTER IAW 46 CFR 185.12-1_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Fire Fighting
Issued 16 December 1995 Resolved
PROVIDE PLAQUES IAW GENERAL NOTE 6 ON MIDSHIPS DRAWING OF 26MAY95_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995
Documentation
Issued 16 December 1995 Resolved
PROVIDE VESSEL DOCUMENT_x001C_ CORRECT PRIOR TO CARRYING PASSENGERS
Condition: Unknown
Due 16 December 1995
Resolved 16 December 1995