Records from 2016 to 2026. Most recent: inspection, 6 May 2026.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 6 May 2026
Resolved
Conduct underway man over board drills with Coast Guard Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2026
Resolved 7 May 2026
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2026
Resolved
Proplery stow adult and children's life jackets. Adult life jackets were found in the children's mark locations on the main deck
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2026
Resolved 20 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 May 2026
Resolved
Properly mark stowage location of life jackets with size and number stored on aft texas deck both sides
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 5 June 2026
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 6 May 2026
Resolved
Make aft bulkhead starboard side engine room vapor tight to prevent CO2 from expecting
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 5 June 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 May 2026
Resolved
Prove proper operation of emergency lights on main deck forward and starboard side aft
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2026
Resolved 5 June 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 6 May 2026
Resolved
Provide a properly working flashlight for the bridge
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 20 May 2026
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 6 May 2026
Resolved
Replace all expried items in the first aid kit
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 20 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 May 2026
Resolved
Remove all expired flares and labeling form the bridge
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2026
Resolved 20 May 2026
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 8 May 2025
Resolved
Conducted underway man overboard drill with CG inspector before carrying passengers
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 May 2025
Resolved 5 June 2025
Resolution: all sat
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 8 May 2025
Resolved
Install guard on front of the generator to prevent anyone from coming into contact with the flywheeel
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 June 2025
Resolved 5 June 2025
Resolution: All sat
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 9 May 2024
Resolved
Prove proper operation of fire pump to produce 50 PSI.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2024
Resolved 10 June 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 May 2024
Resolved
Replace broken/ hanging stern light prior to night operations.
Action required: 705 - Other - as specified
Due 9 May 2024
Resolved 10 June 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 May 2024
Resolved
Replace leaking fire hose on Starboard side are 2nd deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2024
Resolved 10 June 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 May 2024
Resolved
Prove proper operation of Emergency lighting on the boiler deck starboard side aft and both exit signs on the boiler deck aft
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2024
Resolved 10 June 2024
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 1 June 2023
Resolved
Prove proper operation of Emergency light on port side engine room and in wheelhouse.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 3 July 2023
Resolution: all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 June 2023
Resolved
Secure both battery boxes in engine room to prevent shifting during vessel operations.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 June 2023
Resolved 3 July 2023
Resolution: all sat.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 5 May 2023
Resolved
replaced worn/wasted Max Capacity sign on starboard side going to the top deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 30 May 2023
Resolution: all sat
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 May 2023
Resolved
Remark vessel’s name on all faded Life ring bouys
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 30 May 2023
Resolution: all sat
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 5 May 2023
Resolved
replace all combustible plastic trash cans with non-combustible ones with no openings in the sides or bottom.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 31 July 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 May 2023
Resolved
Prove proper operation of life ring buoy light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 30 May 2023
Resolution: all sat
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 June 2022
Resolved
Window is broken. Glass and other glazing material used in windows must be of material that will not break into dangerous fagments if fractured.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2022
Resolved 22 June 2022
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 8 June 2022
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Engine room supply vent does not close when fixed fire system is activated.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 June 2022
Resolved
Vessel name is not properly stenciled on life ring (faded). Remark 2 life rings with vessels name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 June 2022
Resolved
Life jackets must be in servicable condition. 6 life jackets were found sun rotted and with water damage to reflective material. Passengers reduced to 393 total until new life jackets are procured.
Action required: 705 - Other - as specified
Resolved 3 May 2023
Resolution: vessel has replaced Life jackets
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 8 June 2022
Resolved
Life jackets are required to be marked with the vessel name. Restencil child life jackets with vessels name.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 June 2022
Engineering › Electric Propulsion System › Feeder Circuitry
Issued 11 May 2016
Resolved
Properly tape exposed leads on the bow thruster motor.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 May 2016
Resolved 19 May 2016
Resolution: Received pictures showing properly taped wires.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 May 2016
Resolved
Secure CO2 beverage bottle below galley.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2016
Resolution: Bottle secured.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 11 May 2016
Resolved
Double clamp hose aft of M/E stbd side.
Due 19 May 2016
Resolved 11 May 2016
Resolution: Hose was double clamped.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 11 May 2016
Resolved
Properly secure outlet cover top deck galley stbd side fwd.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2016
Resolution: Outlet cover properly secured.
Lifesaving › Lifebuoys › Serviceable
Issued 11 May 2016
Resolved
Replace wire w/proper uv resistant lanyard on stbd bridge wing.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2016
Resolution: Wire replaced with nylon lanyard.
Engineering › Fuel Oil Service System › Valve, Control
Issued 11 May 2016
Resolved
Install remote fuel shutoff on generator day tank in the Engine Room Port side.
Due 31 January 2017
Resolved 13 October 2016
Resolution: remote fuel shutoff installed.