Records from 2016 to 2026. Most recent: inspection, 19 March 2026.
Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 20
19 March 2026
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8341435
17 April 2025
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8113509
29 April 2024
Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7903747
5 May 2023
In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7681599
10 May 2022
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7447868
9 November 2021
Drydock Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7348519
16 June 2021
Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7229189
6 July 2020
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6998246
17 April 2020
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6940586
1 July 2019
Deficiency Check · Annual Survey · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6741909
1 August 2018
Spot Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6524270
19 April 2018
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6397608
9 August 2017
Spot Check · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6240649
12 April 2017
Administrative Inspection · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6131750
6 August 2016
Spot Check · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5968831
15 July 2016
Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5941742
16 June 2016
Administrative Inspection · Annual Inspection · MARPOL Annex IV Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5913218
22 April 2016
Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5860438
26 February 2016
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5828120
15 January 2016
Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5805101
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 May 2025
Resolved
Vessel Captain must have a current medical certificate to operate a commercial vessel. Vessel Master's last approved medical certificate was dated 17FEB2016. Medical certificates are only valid for a period of up to 5 years.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2026
Resolution: Received notification of the vessels Masters passing. Cleared remaining deficiency for pending medical certificate.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 May 2025
Resolved
The vessels portable fire extinguishers have not been maintained in accordance with NFPA 10. There were no logs of quarterly maintenance and 01 of the extinguishers gauge was in the red.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2025
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 May 2025
Resolved
Vessel could not provide any logs of previous MOB or fire drills that had been conducted in the previous year. Vessel must create and fill out log to include the requirements in 46 CFR 185.520 and 185.524.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2025
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 7 May 2025
Resolved
The upper passenger deck was not marked with the maximum number of passengers permitted.as indicated by the vessel stability letter. It must be marked in at least 1 inch durable numers and letters at all entranceways to that deck.No passengers are permitted on the upper deck until it is properly marked.
Action required: 705 - Other - as specified
Resolved 19 May 2025
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 May 2025
Resolved
There was visible wastage at the base of the superstructure above the engine room on the starboard side. Submit a repair proposal to the local Coast Guard for approval and complete repairs in accordance with proposal. All repairs must be approved by Coast Guard. Notify Coast Guard marine inspectors of progress to include cut out fit up and final welds PRIOR to proceeding to the next steps.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2025
Resolved
The vessels air compressor is over 5 cubic feet and per 46 CFR 176.812 it must be inspected externally and internally (if there is an inspection opening)in accordance with 46 CFR 61.10 every 5 years. The safety relief valves must be tested or replaced twice every five years not to exceed 3 years. The air compressor cannot be used until all tests and inspections are completed. Provide alternate means for sound signal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 19 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 May 2025
Resolved
Vessel must have emergency instructions placard containing instructions for Man over board, fire and rough weather/flooding mounted at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 8 May 2025
Resolution: they were posted during the inspection
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 7 May 2025
Resolved
Each vessel must have a FCC station license. The current license expired in 2005.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2025
Resolved 19 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2024
Resolved
All vessels must have navigation lights. One light nav light had an burnt out build. Replace prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2024
Resolved
generator basin was full of coolant and diesel. Remove contents from basin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 20 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 April 2024
Resolved
Lube oil gauges on port engine were not operational. Repair/replace gauge in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 5 August 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2024
Resolved
All electrical connections should be permenent. Remove jumper cables from inside the battery box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 20 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2024
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard . Vessel only had 2 fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 5 August 2024
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 29 April 2024
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 5 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2022
Resolved
Replace 25 of the deteriorated adult life jackets with new life jackets marked with the vessels name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 21 September 2022
Resolution: new life jackets on board
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 May 2022
Resolved
Install permanent guards on front of engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 21 September 2022
Resolution: installed yellow metal guards
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2022
Resolved
Replace deteriorated oil hose with an adequate hose for the service.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 21 September 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 May 2022
Resolved
Replace broken window on main deck
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 21 September 2022
Resolution: window replaced
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 May 2022
Resolved
Replace forward mooring cable
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 21 September 2022
Resolution: replaced cable
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 May 2022
Resolved
Keep logs and drill records up to date and available for inspection
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 21 September 2022
Resolution: conducted and logged drills
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 November 2021
Resolved
Fire main hull penetration and valve unable to open during inspection due to marine growth. Clear marine growth and provide evidence of clear hull penetration and actuation of valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 February 2022
Resolution: Vessel owner provided satisfactory objective evidence.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 November 2021
Resolved
Vessel has watertight hatches that are missing gasket material. Add and/or replace wasted gasket material to watertight hatches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2022
Resolution: Owner installed new gaskets
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 June 2021
Resolved
Inspect and replace 25 adult lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 23 June 2021
Resolution: Vessel owner purchased new PFD's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2020
Resolved
Replace 01 adult PFD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 15 July 2020
Resolution: Owner had replacement on hand, put it into service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2020
Resolved
Replace retro reflective tape on 14 child and 38 adult PFDs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 August 2020
Resolution: replaced retro tap on life jackets in question
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2020
Resolved
Replace retro reflective tape on ring buoy on 2nd deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 August 2020
Resolution: replaced retro tape on ring buoy
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2020
Resolved
Replace expired ring buoy waterlight battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 August 2020
Resolution: repalced battery
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 July 2020
Resolved
Replace expired first aid kit behind bar and replace all expired items in various first aid kits throughout vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 August 2020
Resolution: replaced first aid kit with approved kit
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 July 2020
Resolved
Provide onboard required distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 August 2020
Resolution: replaced distress signals
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 15 July 2020
Resolved
Provide lightbulb in operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 15 July 2020
Resolution: Lightbulb installed before CG departure.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 July 2020
Resolved
Conduct and record emergency drills and send objective evidence of completion.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 17 August 2020
Resolution: conducted and recorded drills
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 July 2020
Resolved
Provide onboard Light List and Navigation Rules.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 17 August 2020
Resolution: printed light list and has nav rules
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2019
Resolved
Received 18 Adult PFDS, 146 of the total 152 Adult PFDS in accordance with COI. Vessel is limited to 146 Adult Passengers
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 1 October 2019
Resolution: Received 06 Adult PFDS, 152 of the total 152 Adult PFDS in accordance with COI.
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 April 2017
Resolved
Middle three vertical longitudinal frames in bow void space found wasted and fractured.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 12 May 2017
Resolution: Middle three vertical longitudinal frames in bow void space cropped and renewed
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 April 2017
Resolved
Wasted deck longitudinal in #2 starboard void.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 12 May 2017
Resolution: Cropped and renewed wasted deck longitudinal in #2 starboard void.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 12 April 2017
Resolved
Exhaust insulation found to be wasted on both starboard and port sides.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 May 2017
Resolution: Exhaust insulation replaced on both starboard and port sides
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 June 2016
Resolved
36 lifejackets found to be wasted and not in servicable condition. 12 replaced in kind on the spot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 15 July 2016
Resolution: Owner replaced 30 Coast Guard approved lifejackets, passenger restriction has been lifted
Deck/Cargo › Holds/Tanks › Coaming
Issued 22 April 2016
Resolved
Vessel's hatch coaming in the #9 port side void has extensive wastage requiring repairs. Owner must submit drawings, sketches, or written specifications describing the details of any proposed alterations to MSD Quad Cities Marine Inspector as required 46CFR176.700(a). Proposed alterations must be approved by the MSD Quad Cities Marine Inspector before work is started as required 46CFR1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 24 May 2016
Resolution: Vessel's hatch coaming in the #9 port side void has been repaired to the satisfaction of the MSD Quad Cities Marine Inspector
Construction/Loadline › Hull › Keel
Issued 3 March 2016
Resolved
Vessel's dry dock examinations (DDX), internal structural examinations (ISE) and tail shaft examinations (TSE) are due to expire on 22MAR16 and will not meet the minimum requirement that vessels shall be made available for DDX , ISE, and TSE at least once every five years as required by 46 CFR 176.600(c)(2) and 46 CFR 176.670. Owner must keep the Marine Inspector updated to when the vessel will b
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2016
Resolution: Hull and ISE inspections have been completed