SPIRIT OF BROWNVILLE

SPIRIT OF BROWNVILLE is a 1956 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1985, most recently in March 2026, along with 137 deficiencies.

Records from 1985 to 2026. Most recent: inspection, 19 March 2026.

Built
1956
Last inspected
19 March 2026
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI 2768
Flag
UNITED STATES
368418430
Maury page id
psix-43200

Inspections, by type

…with no type recorded2
Years with a record 37 calendar years (1985–2026)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.0 ft × 11.3 ft × 3.5 ft
Registered tonnagegross 42 / net 28
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · DUBUQUE, IA, UNITED STATES · built 1956
Hull materialSteel
PropulsionDiesel Direct
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST LOUIS, MO
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it42 - Regulatory (Subpart C or D), Gross Ton
28 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3616MMSI 368418430 · active · voluntarily equipped · granted 9 May 2025, expires 9 May 2035
WDI2768MMSI 367681540 · expired · compulsorily equipped · granted 1 July 2015, cancelled 2 August 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 61

19 March 2026 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8341435
17 April 2025 COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 8113509
29 April 2024 Administrative Inspection · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7903747
5 May 2023 In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7681599
10 May 2022 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7447868
9 November 2021 Drydock Exam
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7348519
16 June 2021 Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 7229189
6 July 2020 DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6998246
17 April 2020 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6940586
1 July 2019 Deficiency Check · Annual Survey · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6741909
1 August 2018 Spot Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6524270
19 April 2018 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6397608
9 August 2017 Spot Check · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6240649
12 April 2017 Administrative Inspection · Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 6131750
6 August 2016 Spot Check · Administrative Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5968831
15 July 2016 Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5941742
16 June 2016 Administrative Inspection · Annual Inspection · MARPOL Annex IV Survey
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5913218
22 April 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5860438
26 February 2016 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5828120
15 January 2016 Administrative Inspection
Administrative · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5805101
29 October 2015 Spot Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Quad Cities · USCG Heartland District (CGD-H) · Activity 5755953
11 May 2012 Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4308276
16 July 2008 Plan Review "T" Boat · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3337416
29 May 2008 Periodic Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3213867
25 April 2007 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2914054
22 March 2006 COI Inspection · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2607454
6 June 2005 Deficiency Check
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2381490
19 May 2005 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 2359585
6 May 2004 Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 2061260
20 May 2003 Type not recorded
No type recorded · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1802540
30 April 2002 Re-Inspection
Physical examination · MSD QUAD CITIES · USCG Heartland District (CGD-H) · Activity 1610891
17 April 2001 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1405167
27 March 2001 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1453869
6 April 2000 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1446927
25 June 1999 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 884905
6 April 1999 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1404758
6 April 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1414983
8 July 1997 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 777445
6 April 1997 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1435917
14 August 1996 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1084301
27 March 1996 Hull Examination · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1443679
30 March 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1148654
2 May 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 859827
6 April 1994 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1169210
3 June 1993 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1149729
20 May 1993 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1457104
27 July 1992 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 954578
19 May 1992 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1473158
25 July 1991 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 941783
1 May 1991 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 901698
20 February 1991 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 916162
2 May 1990 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 926196
31 August 1989 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1043818
22 June 1989 Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1352538
12 June 1989 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1204746
28 April 1989 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1349295
10 May 1988 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1201124
6 May 1987 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1023076
10 September 1986 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1031831
14 July 1986 Re-Inspection · Credit Drydock
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1304515
22 May 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1292235

Deficiency record · 137

01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 May 2025 Resolved
Vessel Captain must have a current medical certificate to operate a commercial vessel. Vessel Master's last approved medical certificate was dated 17FEB2016. Medical certificates are only valid for a period of up to 5 years.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 February 2026
Resolution: Received notification of the vessels Masters passing. Cleared remaining deficiency for pending medical certificate.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 7 May 2025 Resolved
The vessels portable fire extinguishers have not been maintained in accordance with NFPA 10. There were no logs of quarterly maintenance and 01 of the extinguishers gauge was in the red.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 May 2025
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 7 May 2025 Resolved
Vessel could not provide any logs of previous MOB or fire drills that had been conducted in the previous year. Vessel must create and fill out log to include the requirements in 46 CFR 185.520 and 185.524.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2025
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 7 May 2025 Resolved
The upper passenger deck was not marked with the maximum number of passengers permitted.as indicated by the vessel stability letter. It must be marked in at least 1 inch durable numers and letters at all entranceways to that deck.No passengers are permitted on the upper deck until it is properly marked.
Action required: 705 - Other - as specified
Resolved 19 May 2025
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 May 2025 Resolved
There was visible wastage at the base of the superstructure above the engine room on the starboard side. Submit a repair proposal to the local Coast Guard for approval and complete repairs in accordance with proposal. All repairs must be approved by Coast Guard. Notify Coast Guard marine inspectors of progress to include cut out fit up and final welds PRIOR to proceeding to the next steps.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 May 2025 Resolved
The vessels air compressor is over 5 cubic feet and per 46 CFR 176.812 it must be inspected externally and internally (if there is an inspection opening)in accordance with 46 CFR 61.10 every 5 years. The safety relief valves must be tested or replaced twice every five years not to exceed 3 years. The air compressor cannot be used until all tests and inspections are completed. Provide alternate means for sound signal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 19 May 2025
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 7 May 2025 Resolved
Vessel must have emergency instructions placard containing instructions for Man over board, fire and rough weather/flooding mounted at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2025
Resolved 8 May 2025
Resolution: they were posted during the inspection
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 7 May 2025 Resolved
Each vessel must have a FCC station license. The current license expired in 2005.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 June 2025
Resolved 19 May 2025
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 29 April 2024 Resolved
All vessels must have navigation lights. One light nav light had an burnt out build. Replace prior to operating.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 20 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 April 2024 Resolved
generator basin was full of coolant and diesel. Remove contents from basin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 20 May 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 29 April 2024 Resolved
Lube oil gauges on port engine were not operational. Repair/replace gauge in engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 5 August 2024
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 April 2024 Resolved
All electrical connections should be permenent. Remove jumper cables from inside the battery box.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 20 May 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 April 2024 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (21/2 gallon) buckets, with an attached lanyard . Vessel only had 2 fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 5 August 2024
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 29 April 2024 Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and General description of the drill scenario and training topics
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2024
Resolved 5 August 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2022 Resolved
Replace 25 of the deteriorated adult life jackets with new life jackets marked with the vessels name.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 21 September 2022
Resolution: new life jackets on board
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 10 May 2022 Resolved
Install permanent guards on front of engines.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 21 September 2022
Resolution: installed yellow metal guards
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 May 2022 Resolved
Replace deteriorated oil hose with an adequate hose for the service.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 21 September 2022
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 10 May 2022 Resolved
Replace broken window on main deck
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 21 September 2022
Resolution: window replaced
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 May 2022 Resolved
Replace forward mooring cable
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 21 September 2022
Resolution: replaced cable
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 May 2022 Resolved
Keep logs and drill records up to date and available for inspection
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 June 2022
Resolved 21 September 2022
Resolution: conducted and logged drills
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 November 2021 Resolved
Fire main hull penetration and valve unable to open during inspection due to marine growth. Clear marine growth and provide evidence of clear hull penetration and actuation of valve.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 February 2022
Resolution: Vessel owner provided satisfactory objective evidence.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 10 November 2021 Resolved
Vessel has watertight hatches that are missing gasket material. Add and/or replace wasted gasket material to watertight hatches.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2022
Resolution: Owner installed new gaskets
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 June 2021 Resolved
Inspect and replace 25 adult lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 July 2021
Resolved 23 June 2021
Resolution: Vessel owner purchased new PFD's.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2020 Resolved
Replace 01 adult PFD.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 15 July 2020
Resolution: Owner had replacement on hand, put it into service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 July 2020 Resolved
Replace retro reflective tape on 14 child and 38 adult PFDs.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 August 2020
Resolution: replaced retro tap on life jackets in question
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2020 Resolved
Replace retro reflective tape on ring buoy on 2nd deck.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 August 2020
Resolution: replaced retro tape on ring buoy
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 July 2020 Resolved
Replace expired ring buoy waterlight battery.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 August 2020
Resolution: repalced battery
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 15 July 2020 Resolved
Replace expired first aid kit behind bar and replace all expired items in various first aid kits throughout vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 August 2020
Resolution: replaced first aid kit with approved kit
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 July 2020 Resolved
Provide onboard required distress signals.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 17 August 2020
Resolution: replaced distress signals
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 15 July 2020 Resolved
Provide lightbulb in operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 July 2020
Resolved 15 July 2020
Resolution: Lightbulb installed before CG departure.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 15 July 2020 Resolved
Conduct and record emergency drills and send objective evidence of completion.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 17 August 2020
Resolution: conducted and recorded drills
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 15 July 2020 Resolved
Provide onboard Light List and Navigation Rules.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 17 August 2020
Resolution: printed light list and has nav rules
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 July 2019 Resolved
Received 18 Adult PFDS, 146 of the total 152 Adult PFDS in accordance with COI. Vessel is limited to 146 Adult Passengers
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 October 2019
Resolved 1 October 2019
Resolution: Received 06 Adult PFDS, 152 of the total 152 Adult PFDS in accordance with COI.
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 April 2017 Resolved
Middle three vertical longitudinal frames in bow void space found wasted and fractured.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 12 May 2017
Resolution: Middle three vertical longitudinal frames in bow void space cropped and renewed
Construction/Loadline › Hull › Longitudinal Frame
Issued 12 April 2017 Resolved
Wasted deck longitudinal in #2 starboard void.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 12 May 2017
Resolved 12 May 2017
Resolution: Cropped and renewed wasted deck longitudinal in #2 starboard void.
Engineering › Diesel Engine (propulsion-electric) › Exhaust Manifold
Issued 12 April 2017 Resolved
Exhaust insulation found to be wasted on both starboard and port sides.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 May 2017
Resolution: Exhaust insulation replaced on both starboard and port sides
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 16 June 2016 Resolved
36 lifejackets found to be wasted and not in servicable condition. 12 replaced in kind on the spot.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 June 2016
Resolved 15 July 2016
Resolution: Owner replaced 30 Coast Guard approved lifejackets, passenger restriction has been lifted
Deck/Cargo › Holds/Tanks › Coaming
Issued 22 April 2016 Resolved
Vessel's hatch coaming in the #9 port side void has extensive wastage requiring repairs. Owner must submit drawings, sketches, or written specifications describing the details of any proposed alterations to MSD Quad Cities Marine Inspector as required 46CFR176.700(a). Proposed alterations must be approved by the MSD Quad Cities Marine Inspector before work is started as required 46CFR1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 24 May 2016
Resolution: Vessel's hatch coaming in the #9 port side void has been repaired to the satisfaction of the MSD Quad Cities Marine Inspector
Construction/Loadline › Hull › Keel
Issued 3 March 2016 Resolved
Vessel's dry dock examinations (DDX), internal structural examinations (ISE) and tail shaft examinations (TSE) are due to expire on 22MAR16 and will not meet the minimum requirement that vessels shall be made available for DDX , ISE, and TSE at least once every five years as required by 46 CFR 176.600(c)(2) and 46 CFR 176.670. Owner must keep the Marine Inspector updated to when the vessel will b
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 May 2016
Resolution: Hull and ISE inspections have been completed
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 May 2008 Resolved
Properly support the 2nd deck overhead awning wires and remove the abandoned wire in the vessel’s bridge overhead.
Condition: Unknown
Due 29 June 2008
Resolved 16 July 2008
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 29 May 2008 Resolved
Replace both forward brow frapping lines and properly wire the brow electrical outlet box.
Condition: Unknown
Due 29 June 2008
Resolved 16 July 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 May 2008 Resolved
Installed CG approved navigational lights. (Currently colored glass globes).
Condition: Placed in Improper Service
Due 29 June 2008
Resolved 16 July 2008
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 29 May 2008 Resolved
Provide the specifications on the new carpet.
Condition: Placed in Improper Service
Due 29 June 2008
Resolved 16 July 2008
Resolution: Under T regs carpet specs are not required on a steel vessel.
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 May 2008 Resolved
Properly support overheads wire in the stern void.
Condition: Unknown
Due 29 June 2008
Resolved 16 July 2008
Engineering › Fuel Oil Service System › Piping
Issued 29 May 2008 Resolved
Install screw type hose clamps (currently spring type) on the generator fuel filter.
Condition: Placed in Improper Service
Due 29 June 2008
Resolved 16 July 2008
Engineering › Fuel Oil Service System › Hose
Issued 29 May 2008 Resolved
Replace all the port MDE flexible fuel lines.
Condition: Improper/Lack of Maintenance
Due 29 June 2008
Resolved 16 July 2008
Fire Fighting › Fire Hydrants › Condition
Issued 29 May 2008 Resolved
Ensure the fire station is properly outfitted at all times.
Condition: Unknown
Due 29 June 2008
Resolved 16 July 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 29 May 2008 Resolved
Ensure the crew is in a year round D&A program or conduct annual pre-employment tests.
Condition: Placed in Improper Service
Due 29 June 2008
Resolved 16 July 2008
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 25 April 2007 Resolved
Ensure chemical testing program meets 46 CFR16.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Engineering › Bilge Water Management System › Not Operational
Issued 25 April 2007 Resolved
Prove proper operation of bilge system and ensure piping system has installed check valves.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 25 April 2007 Resolved
Ensure the vessel has (3) B-II portable fire extinguishers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 25 April 2007 Resolved
Properly insulate both generators dry exhaust piping.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 25 April 2007 Resolved
Post life jacket donning instructions.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Engineering › Diesel Engine (auxiliary) › Cylinder Head
Issued 25 April 2007 Resolved
Provide a repair service report on the leaking main generator.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 25 April 2007 Resolved
Replace port MDE hydraulic hoses and fuel filter hose.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Engineering › Bilge Water Management System › Piping
Issued 25 April 2007 Resolved
Label bilge suction manifold valves.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 25 April 2007 Resolved
Properly secure the port engine room fire extinguisher.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Lifesaving › Hand Flares › Expired
Issued 25 April 2007 Resolved
Replace (3) expired day flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Fire Fighting › Fire Pumps › Capacity
Issued 25 April 2007 Resolved
Prove proper operation of the fire main system.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Engineering › Fuel Oil Service System › Valve
Issued 25 April 2007 Resolved
Ensure a fuel shut-off valve is located at the fuel tank and properly labeled.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 April 2007
Resolved 11 July 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 25 April 2007 Resolved
Ensure master has a restricted radio operator's permit.
Condition: Unknown
Due 25 May 2007
Resolved 11 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2007 Resolved
Remove abandoned wires in the #2 stbd, void, overhead.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 11 July 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 25 April 2007 Resolved
Secure the fuel line in the # 4 centerline void.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 11 July 2007
Stability › Watertight Integrity › General
Issued 25 April 2007 Resolved
Replace the # 1 void, scuttle gasket.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 11 July 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 25 April 2007 Resolved
Replace the stbd side, potable water, vent screen.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 11 July 2007
Engineering › Compressed Air System (control) › Piping
Issued 25 April 2007 Resolved
Properly secure the air line located above the air compressor.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 11 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2007 Resolved
Ensure all overhead wires are secured with metal supports.
Condition: Unknown
Due 25 May 2007
Resolved 11 July 2007
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 25 April 2007 Resolved
Clean both MDE's air intake vents.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 11 July 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 25 April 2007 Resolved
Install a cover on the men's head, overhead light.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 11 July 2007
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 25 April 2007 Resolved
Properly secure both MDE's air intake hoses.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 11 July 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 April 2007 Resolved
Ensure the vessel has a CG light list.
Condition: Unknown
Due 25 May 2007
Resolved 11 July 2007
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 25 April 2007 Resolved
Properly label port and stbd, main deck, PFD lockers.
Condition: Unknown
Due 25 May 2007
Resolved 11 July 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 April 2007 Resolved
Carry only 132 passengers until the main deck, lifejackets are repaired or replaced.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 11 July 2007
Electrical › Electric Generation Source (service) › Panelboard
Issued 25 April 2007 Resolved
Prove proper operation of the main generator, voltage gauge.
Condition: Unknown
Due 25 May 2007
Resolved 11 July 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2007 Resolved
Ensure first aid kit meets 46 CFR 184.710.
Condition: Unknown
Due 25 May 2007
Resolved 11 July 2007
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2007 Resolved
Replace damaged wire in stern void overhead.
Condition: Improper/Lack of Maintenance
Due 25 May 2007
Resolved 11 July 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 25 April 2007 Resolved
Ensure an adequate supply of chemical agent is onboard for the installed MSD.
Condition: Unknown
Due 25 May 2007
Resolved 4 July 2007
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 12 April 2006 Resolved
Properly label all life jacket stowage areas with amount of life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2006
Resolved 21 April 2006
Documentation › Markings/Placards › Lifejacket Placard
Issued 12 April 2006 Resolved
Properly post life jacket donning instructions al life jacket stowage locations.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2006
Resolved 21 April 2006
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 April 2006 Resolved
Properly install retro-tape on all life jackets.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2006
Resolved 21 April 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 April 2006 Resolved
Remove extension cords from the main level bar.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2006
Resolved 21 April 2006
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 12 April 2006 Resolved
Properly connect all electrical outlets on the main deck (reverse polarity)
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2006
Resolved 21 April 2006
Engineering › Bilge Water Management System › Strainer
Issued 12 April 2006 Resolved
Properly install strainer on lazarette bilge suction.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2006
Resolved 21 April 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 April 2006 Resolved
Properly provide an approved first aid kit.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2006
Resolved 21 April 2006
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 12 April 2006 Resolved
Properly replace glass on 2nd window back port side on main deck.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2006
Resolved 12 April 2006
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 12 April 2006 Resolved
Provide and install an emergency broadcast placard at radio station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2006
Resolved 21 April 2006
Documentation › Markings/Placards › Warning Signs
Issued 12 April 2006 Resolved
Properly label all switches and alarms in the wheelhouse.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2006
Resolved 21 April 2006
Fire Fighting › Remote Fuel Shutoff › General
Issued 12 April 2006 Resolved
Properly label emergency fuel shutoff valves pull location.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2006
Resolved 21 April 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 May 2005 Resolved
Life Line and Light line are wasted due to Sun damage. Replace IAW 46 CFR.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2005
Resolved 6 June 2005
Resolution: Replaced with new line
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 19 May 2005 Resolved
Condemed 32 Adult PFD's due to sun Damage. Replace inkind.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2005
Resolved 6 June 2005
Resolution: Replaced with new PFD''s 32
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 19 May 2005 Resolved
Need to post Life Jacket donning placard.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2005
Resolved 6 June 2005
Resolution: Posted
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 19 May 2005 Resolved
Need to seperate the Child PFD's from the Adult PFD's and label
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2005
Resolved 6 June 2005
Resolution: Seperated and labled area
Electrical › Lighting (service) › Lighting Fixture
Issued 19 May 2005 Resolved
Lights on upper deck over head in passenger area need protective covers installed.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 June 2005
Resolved 6 June 2005
Resolution: Installed covers.
Electrical
Issued 6 April 2000 Resolved
Hard-wire A/C unit in pilot house and remove extension cord
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Fire Fighting
Issued 6 April 2000 Resolved
Place fire extinquisher in proper bracket in pilot house.
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Electrical
Issued 6 April 2000 Resolved
Place proper guards on lights in pilot house
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Electrical
Issued 6 April 2000 Resolved
Place proper stuffing tube in over head junction box in pilot house
Condition: Unknown
Due 6 April 2000
Resolved 6 April 2000
Construction/Loadline
Issued 6 April 1999 Resolved
PLUG AROUND WATER TIGHT PENETRATION STBD AFT MIDSHIP VOID
Condition: Unknown
Due 1 May 1999
Resolved 14 May 1999
Electrical
Issued 6 April 1999 Resolved
INSTALL LIGHT BULB COVERS FOR SECOND DECK ELECTRICAL LIGHTING.
Condition: Unknown
Due 1 May 1999
Resolved 14 May 1999
Engineering
Issued 6 April 1999 Resolved
REPLACE BROKEN INSP ACESS PLUG ON AIR RECEIVER.
Condition: Unknown
Due 1 May 1999
Resolved 14 May 1999
Electrical
Issued 6 April 1999 Resolved
REPLACE ELECTRICAL FACEPLATEON 01 DECK MIDSHIP PORTSIDE.
Condition: Unknown
Due 1 May 1999
Resolved 14 May 1999
Construction/Loadline
Issued 6 April 1999 Resolved
Install high level bilge alarms.
Condition: Unknown
Due 6 April 1999
Resolved 6 April 1999
Accommodation/Occupational Safety
Issued 6 April 1999 Resolved
MARINE SANITATION DEVICE NEEDS MANUFACTURING LABEL PERMENANTLY AFFIXED.
Condition: Unknown
Due 1 May 1999
Resolved 14 May 1999
Lifesaving
Issued 6 April 1998 Resolved
PROVIDE NEW LINE FOR LIFE RING PRIOR TO GETTING UNDERWAY WITH PASSENGERS.
Condition: Unknown
Due 7 April 1998
Resolved 28 April 1998
Construction/Loadline
Issued 6 April 1998 Resolved
REMOVE STEEL WOOL FROM ENGINEROOM BLKHDS AND MAKE WATERTIGHT.
Condition: Unknown
Due 7 April 1998
Resolved 28 April 1998
Lifesaving
Issued 6 April 1998 Resolved
REPLACE PASSENGER COUNT BY 9 UNTIL NEW LIFEJACKETS ARE ON BOARD.
Condition: Unknown
Due 7 April 1998
Resolved 28 April 1998
Lifesaving
Issued 6 April 1998 Resolved
RESTENCIL LIFE RINGS (2)
Condition: Unknown
Due 7 April 1998
Resolved 28 April 1998
Engineering
Issued 6 April 1998 Resolved
REPLACE 40X40 MESH WITH 30X30 MESH.
Condition: Unknown
Due 7 April 1998
Resolved 28 April 1998
Lifesaving
Issued 6 April 1998 Resolved
REPLACED 2 EXPIRED ORANGE FLARES PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 7 April 1998
Resolved 28 April 1998
Accommodation/Occupational Safety
Issued 27 March 1996 Resolved
PROVIDE INSECT SCREEN TO POTABLE WATER TANK VENT.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Engineering
Issued 27 March 1996 Resolved
REPAIR EMERGENCY FUEL OIL CUT-OFF VALVE TO BOTH MDE, GERNERATOR, AND FUEL TANK.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Engineering
Issued 27 March 1996 Resolved
REPLACE FUEL OIL FLAME ARRESTER SCREEN TO FUEL TANK VENT.
Condition: Unknown
Due 27 March 1996
Resolved 27 March 1996
Lifesaving
Issued 6 April 1994 Resolved
SECURE CO2 BOTTLES TO THE BULKHEAD.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Lifesaving
Issued 6 April 1994 Resolved
FIND LEAK AND CORRECT PROBLEM WITH FRESH WATER SYSTEM
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Fire Fighting
Issued 6 April 1994 Resolved
DEMONSTRATE FIRE PUMP.
Condition: Unknown
Due 6 April 1994
Resolved 6 April 1994
Lifesaving
Issued 20 May 1993 Resolved
ATTACH FLOAT LIGHT TO RING BUOY WITH SEPARATE LINE.
Condition: Unknown
Due 20 June 1993
Resolved 14 June 1993
Navigation
Issued 19 May 1992 Resolved
PROVIDE ONE BELL.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Documentation
Issued 19 May 1992 Resolved
PROVIDE ONE OIL POLLUTION PLACARD AND INSTALL NEAR BILGE PUMP.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Lifesaving
Issued 19 May 1992 Resolved
PROVIDE SIX DAYLIGHT AND SIX NIGHT DISTRESS SIGNALS.
Condition: Unknown
Due 19 May 1992
Resolved 19 May 1992
Engineering
Issued 28 April 1989 Resolved
PROVIDE RELIEF VALVE TO ENGINE ROOM AIR RECEIVER.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Electrical
Issued 28 April 1989 Resolved
PROVIDE BATTERY BOX COVER.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Engineering
Issued 28 April 1989 Resolved
LABEL BILGE MANIFORD.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Fire Fighting
Issued 28 April 1989 Resolved
EQUIP HAND PUMP FOR FIRE FIGHTING.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Fire Fighting
Issued 28 April 1989 Resolved
MOUNT ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Lifesaving
Issued 28 April 1989 Resolved
PROVIDE 7 ADULT LIFE JACKETS TOTAL PERSONS LIMITED TO 143.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Electrical
Issued 28 April 1989 Resolved
PROVIDE GUARD FOR LIGHT ENGINE ROOM.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Electrical
Issued 28 April 1989 Resolved
SECURE OVERHEAD WIRING IN ENGINE ROOM.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Electrical
Issued 28 April 1989 Resolved
PERMANENTLY INSTALL BATTERY CHARGER SYSTEM.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Navigation
Issued 28 April 1989 Resolved
PROVIDE DISTRESS FLARES SUITABLE WATERPROOF CONTAINER.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Navigation
Issued 28 April 1989 Resolved
REPLACE STB RUNNING LIGHT GLOBE.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Documentation
Issued 28 April 1989 Resolved
POST FCC (RADIO) LICENSE.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Engineering
Issued 28 April 1989 Resolved
FIX LEAK TO FUEL OIL RETURN LINE PORT ENGINE.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Engineering
Issued 28 April 1989 Resolved
PROVIDE BELT GUARDS FOR DIESEL ENGINES.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Electrical
Issued 28 April 1989 Resolved
PROVIDE BLANKS TO CURCUIT BOARD (BEHIND BAR).
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Electrical
Issued 28 April 1989 Resolved
REMOVE DEAD END CABLES OVER BAR.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Electrical
Issued 14 July 1986 Resolved
REMOVE JUMPER CABLES FROM BATTERIES TO GENERATOR STARTER AND HARD WIRE STARTING SYSTEM.
Condition: Unknown
Due 14 July 1986
Resolved 14 July 1986
Construction/Loadline
Issued 14 July 1986 Resolved
PLUG THREE HOLES IN UPPER PORTION OF FORWARD ENGINE ROOM BULKHEAD NEAR CENTERLINE (OLD WIRING PENETRATIONS).
Condition: Unknown
Due 14 July 1986
Resolved 14 July 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.