Records from 2017 to 2019. Most recent: inspection, 7 October 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 October 2019
No resolution recorded
All gearing and every shaft of the coupling used for transmission of power to machinery essential for the propultion and safety of the ship or for the safety of persons on board shall be so designated and constructed that they withstand the maximum workign stresses to which they may be submected. PSCO noted numerous leaks on boht sides of they dydraulic ram emergency steering gear system during testing.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 October 2019
No resolution recorded
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present reguations to ensure that the ship in all respects will remain fit to proceed to sea. The air conctioner concencer si frozen over and leaking.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Fire Pumps › Pressure
Issued 11 September 2017
Resolved
0740 - PUMPS - IN CARGO SHIPS OF 2,000 GT AND UPWARDS, IF A FIRE IN ANY ONE COMPARTMENT COULD PUT ALL THE PUMPS OUT OF ACTION, THERE SHALL BE AN ALTERNATIVE MEANS CONSISTING OF A FIXED INDEPENDENTLY DRIVEN FIRE PUMP WHICH SHALL BE CAPABLE OF SUPPLYING TWO JETS OF WATER. PSCO OBSERVED THE VESSEL'S EMERGENCY FIRE PUMP WAS NOT CAPABLE OF SUPPLYING SUCTION. - SOLAS 74(1997 CONS) CH. II-2 REG. 4.3.3.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2017
Resolution: RECEIVED ADEQUATE CLASS DOCUMENTATION REGARDING REPAIRS
Fire Fighting › Fire Pumps › Pressure
Issued 11 September 2017
Resolved
0740 - PUMPS - EACH OF THE REQUIRED FIRE PUMPS SHALL BE CAPABLE OF DELIVERING AT LEAST THE TWO REQUIRED JETS OF WATER. [name withheld] ON THE NO. 1 AND NO. 2 GSP PUMPS PREVENTING THE PUMPS WORKING IN ACCORDANCE WITH THE REGULATION. - SOLAS 74(1997 CONS) CH. II-2 REG.4.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2017
Resolution: RECEIVED ADEQUATE CLASS DOCUMENTATION REGARDING REPAIRS.
Engineering › Fuel Oil Storage/Transfer System › Pump
Issued 11 September 2017
Resolved
0999 - FUEL OIL TRANSFER ARRANGEMENT - WHERE NECESSARY, FUEL OIL SHALL BE SUITABLY PROTECTED TO AVOID AS FAR AS PRACTICABLE OIL SPRAY AND OIL LEAKAGE. PSCO OBSERVED A SUBSTANTIAL LEAK ON THE NO. 2 FUEL OIL TRANSFER PUMP. - SOLAS 74(1997 CONS) CH. II-2 REG. 16.5.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2017
Resolution: RECEIVED ADEQUATE CLASS DOCUMENTATION REGARDING REPAIRS.
Electrical › Electric Generation Source (emergency) › Generator
Issued 11 September 2017
Resolved
0999 - CONDITION AFTER SURVEY - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO INSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR CREW. PSCO OBSERVED AN EXCESSIVE LEAK ON THE EMERGENCY GENERATOR WHILE CONDUCTING OPERATIONAL TEST. - SOLAS 74 (2014 CONS) CH. I REG. 11(a)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2017
Resolution: RECEIVED ADEQUATE CLASS DOCUMENTATION REGARDING REPAIRS.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 11 September 2017
Resolved
0999 - FUEL TRANSFER ARRANGEMENTS - IN A SHIP IN WHICH FUEL OIL IS USED, THE ARRANGEMENTS FOR THE STORAGE, DISTRIBUTION, AND UTILIZATION OF THE FUEL OIL SHALL BE SUCH AS TO ENSURE THE SAFETY OF THE SHIP AND PERSONS ON BOARD. PSCO OBSERVED 04 FUEL VALVES REMOVED FROM THE TRANSFER PIPING SYSTEM. - SOLAS 74(1997 CONS) CH. II-2, REG. 15.2
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 September 2017
Resolution: RECEIVED ADEQUATE CLASS DOCUMENTATION REGARDING REPAIRS.
Engineering › Feedwater/Condensate Water System › Piping
Issued 11 September 2017
Resolved
0999 - CONDITION AFTER SURVEY - AFTER ANY SURVEY OF THE SHIP UNDER REGULATIONS 7, 8, 9, 10 HAS BEEN COMPLETED, NO CHANGE SHALL BE MADE IN THE STRUCTURE AND MACHINERY ARRANGEMENTS. PSCO OBSERVED PATCHES ON THE COOLING WATER PIPING, ON THE MDG, AND ON THE FIRE MAIN. - SOLAS 74(2004 CONS) CH. I, REG. 11(b)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 12 September 2017
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 11 September 2017
Resolved
2550 - MAINTENANCE OF SHIP AND EQUIPMENT - THE COMPANY AND THE SHIP SHALL COMPLY WITH THE REQUIREMENTS OF THE ISM CODE. THE COMBINED SIGNIFICANCE OF THE ABOVE DEFICIENCIES INDICATE A SUBSTANTIAL NONCOMPLIANCE WITH THE ISM CODE AND MAY POSE A SERIOUS THREAT TO THE SHIP AND CREW. [name withheld] ISM AUDIT. - SOLAS 74(2014 CONS) CH. IX REG. 3.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 12 September 2017
Resolved 7 October 2019
Resolution: Cleared as a result of reviewing internal and external audits.