Records from 2000 to 2001. Most recent: inspection, 14 August 2001.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 7
14 August 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1069711
12 March 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1061182
17 February 2001
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1444471
18 September 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1054284
1 September 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 821934
5 July 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 819860
26 April 2000
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1440303
Accommodation/Occupational Safety
Issued 17 February 2001
Resolved
CROP AND RENEW WASTED VENTILATION DUCT STBD STOREROOM.
Condition: Unknown
Due 17 February 2001
Resolved 17 February 2001
Engineering
Issued 17 February 2001
Resolved
REMOVE EXCESS FUEL FROM COFFERDAM AND PROVE OIL TIGHT INTEGRITY OF SLOP_x001C_ TANK.
Condition: Unknown
Due 17 February 2001
Resolved 17 February 2001
Electrical
Issued 17 February 2001
Resolved
PROVE PROPER OPERATION OF #3 GENERATOR.
Condition: Unknown
Due 17 February 2001
Resolved 17 February 2001
Construction/Loadline
Issued 17 February 2001
Resolved
CROP AND RENEW UNDER DECK SUPPORTS AT #1 LIFEBOAT STATION.
Condition: Unknown
Due 17 February 2001
Resolved 17 February 2001
Accommodation/Occupational Safety
Issued 26 April 2000
Resolved
Galley store room - remove plastic bag and install grease trap.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Deck/Cargo
Issued 26 April 2000
Resolved
Install cover over motor on forklift.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Lifesaving
Issued 26 April 2000
Resolved
Replace on-deck life rings.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Fire Fighting
Issued 26 April 2000
Resolved
AT FIX FIREFIGHTING SYSTEMS: PAINT LOCKERS AND ENGINE ROOM POST OPERATING INSTRUCTIONS.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Lifesaving
Issued 26 April 2000
Resolved
EPIRB - label with unit name.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Accommodation/Occupational Safety
Issued 26 April 2000
Resolved
Connect door closure at 2nd deck lounge.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Electrical
Issued 26 April 2000
Resolved
REMOVE DEAD END WIRE AT AFT END OF HOUSE PORT SIDE MAIN DECK.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Lifesaving
Issued 26 April 2000
Resolved
PROVE PROPER OPERATION OF PORT LIFEBOAT GRAVITY DAVIT.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Lifesaving
Issued 26 April 2000
Resolved
CONDUCT LIFEBOAT HOOK RELEASE GEAR TEST.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Accommodation/Occupational Safety
Issued 26 April 2000
Resolved
PROVIDE DOCUMENTATION FOR TESTING OF PRESSURE VESSEL SAFETY RELIEF VALVES.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Lifesaving
Issued 26 April 2000
Resolved
EPIRB - untie from rail.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Electrical
Issued 26 April 2000
Resolved
Label switches in breaker panels.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Construction/Loadline
Issued 26 April 2000
Resolved
Replace gasket on water tight door at STBD leg well.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Electrical
Issued 26 April 2000
Resolved
Install blanks in breaker panel 101 and 103 in engine room and 106 in air compressor room.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Accommodation/Occupational Safety
Issued 26 April 2000
Resolved
Make repairs to sink 01 deck head.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Lifesaving
Issued 26 April 2000
Resolved
Label on-deck life jacket lockers.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Electrical
Issued 26 April 2000
Resolved
In galley, properly label E-lights.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Lifesaving
Issued 26 April 2000
Resolved
In lifeboats, replace aspirin and provide an equipment checkoff list.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Construction/Loadline
Issued 26 April 2000
Resolved
Install plugs in all kick pipes and through holes on top of shale shaker house.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000