MAURY USCG vessel records
← All vessels

DENISE D

Built
1956
Last inspected
3 February 2010
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.

Inspection record

Last inspected 3 February 2010
…with no type recorded13
Operational controls None recorded without a removal date
Years with a record 25 calendar years (1984–2010)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WH5225
Flag
UNITED STATES
Tonnage
433 - Regulatory (Subpart C or D), Gross Ton 433 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-43242
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 52

3 February 2010 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3689089
25 February 2009 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3423497
3 July 2008 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3255693
13 June 2008 Periodic Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 3235995
10 May 2007 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2927656
15 March 2007 Damage Survey
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 2890697
1 December 2005 Annual Inspection · Hull Examination · Cargo Tank Internal · Internal Structural Exam
Physical examination · Marine Safety Unit Paducah · USCG Heartland District (CGD-H) · Activity 2544217
3 February 2005 MTSA Verification · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2285755
9 February 2004 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2003324
3 February 2004 Periodic Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2000210
30 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997487
23 January 2001 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1444448
16 November 2000 Hull Examination
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1405076
7 February 2000 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1465535
16 August 1999 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1113499
28 July 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 769124
23 July 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 195749
23 July 1999 Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1402912
30 June 1999 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1092115
25 February 1999 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1410042
25 February 1998 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1436056
27 February 1997 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1450006
24 December 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 752843
21 December 1996 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1095613
17 December 1996 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 195748
17 December 1996 Damage Survey
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1092811
28 February 1996 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 885172
2 November 1995 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1183502
7 March 1995 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1171584
3 March 1994 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 853131
9 December 1993 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 172424
22 April 1993 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1454005
11 May 1992 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 951802
16 April 1992 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 957010
5 March 1992 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1317954
13 March 1991 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 907663
12 March 1991 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 907849
24 September 1990 Hull Examination
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 904632
20 March 1990 Deficiency Check
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1220621
9 March 1990 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 904804
4 May 1989 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 891772
23 March 1989 Administrative
Administrative · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1041088
8 March 1989 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1201001
14 February 1989 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 440033
10 March 1988 COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1296092
23 December 1987 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 526112
12 March 1987 Re-Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1321297
10 March 1986 Credit Drydock · COI Inspection
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 1298734
10 February 1986 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 997715
18 November 1985 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 985253
7 December 1984 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 976108
4 December 1984 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1286072

Deficiency record · 54

Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 February 2010 Resolved
Owner/Operator did not submit written application for inspection for certification to cognizant OCMI within 30 day time period as per 46CFR 31.01-159(a).
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 4 March 2010
Resolution: Sector SIO notified, SOHV command currently working with SIO and owner/operator on possible resolution.
Pollution Prevention/Response › Prevention Equipment › Fixed Containment
Issued 3 February 2010 Resolved
Fixed containment did not meet requirements of 33CFR 155.310 due to having rainwater and product within containment.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 8 April 2010
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 3 February 2010 Resolved
Oil transfer hose has significant wear/tear/kinks; oil transfer hose also had a coupling that was not approved as per 33 CFR 154.500 using a non-approved coupling and wire banding.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 8 April 2010
Resolution: Hose was removed and discarded.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 3 February 2010 Resolved
Oil transfer procedures were not current with owner/operator procedures.
Action required: 705 - Other - as specified
Due 4 March 2010
Resolved 4 March 2010
Resolution: Owner/operator amended transfer procedures on-site.
Pollution Prevention/Response › Prevention Equipment › Cargo Monitor/Control System
Issued 3 February 2010 Resolved
DOI's were not filled out completely; several DOI's were missing times/dates.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 8 April 2010
Resolution: Reviewed several DOI''''s and all were filled out correctly.
Deck/Cargo › Vapor Control Systems › Flame Screens
Issued 3 February 2010 Resolved
Flame Screen on STBD #3 tank torn.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 8 April 2010
Resolution: Flame screen was renewed.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 3 February 2010 Resolved
Exhaust piping in pump room not lagged IAW with NFPA 302 4-1.2 as required by 46CFR 58.10-5
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 8 April 2010
Resolution: Insulation installed.
Engineering › Diesel Engine (auxiliary) › Air Cleaner
Issued 3 February 2010 Resolved
Breather for diesel engine in the pump room saturated with oil and dust.
Action required: 705 - Other - as specified
Due 5 April 2010
Resolved 8 April 2010
Resolution: Breather cleaned.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 3 February 2010 Resolved
Excessive leaks on pump engines and hosing.
Action required: 705 - Other - as specified
Due 5 March 2010
Resolved 8 April 2010
Resolution: F/O pump leak repaired.
Engineering › Diesel Engine (auxiliary) › Pump, High Pressure (fuel injection)
Issued 3 February 2010 Resolved
Flexible fuel lines do not meet SAE-J-1942 standard; length greater than 30 inches.
Action required: 705 - Other - as specified
Due 5 March 2010
Resolved 8 April 2010
Resolution: Fuel oil filter moved so shorter hoses could be installed IAW 46 CFR.
Engineering › Diesel Engine (auxiliary) › Gear/Clutch Starter (hydraulic)
Issued 25 February 2009 Resolved
Remove no longer used hydraulic starter accumulator and associated components.
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 26 February 2009
Resolution: Received call from vessel representative stating all unnecessary components have been removed.
Engineering › Fuel Oil Service System › Hose
Issued 25 February 2009 Resolved
Replace all leaking fuel oil hoses for cargo pump prime mover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 26 February 2009
Resolution: Received call from vessel representative stating that all fuel oil lines for the cargo pump prime mover have been replaced.
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 25 February 2009 Resolved
Repair leaking jacket water fitting on water cooled exhaust manifold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 26 February 2009
Resolution: Received call from vessel representative stating that the fittings were replaced and the leak stopped.
Engineering › Lubricating Oil Service System › Hose
Issued 25 February 2009 Resolved
Repair/ Replace leaking lube oil gage line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 26 February 2009
Resolution: Received call from vessel representative stating the gage line has been replaced and the leak is corrected.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 25 February 2009 Resolved
Replace flame screen on # 3 port cargo tank pressure vacuum valve.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 March 2009
Resolved 26 February 2009
Resolution: Flame screen replaced prior to completion of inspection.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 25 February 2009 Resolved
Remove standing water from cargo pump room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 25 February 2009
Resolution: Corrected prior to the completion of the vessel inspection.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 25 February 2009 Resolved
Repair/ replace leaking packing on cargo transfer pump.
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 25 February 2009
Resolution: Corrected prior to completion of vessel inspection.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 25 February 2009 Resolved
Properly mark all draft readings with contrasting colors for clear visibility on barge.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 9 April 2009
Resolution: Vessel representative stenciled draft marks on vessel and will have them permanently affixed at next dry-dock.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 25 February 2009 Resolved
Replace two (2) worn transfer hoses.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 9 April 2009
Resolution: New hoses placed onboard.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 25 February 2009 Resolved
Properly identify all transfer hoses to match transfer hose test log book.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 9 April 2009
Resolution: Test log created.
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 25 February 2009 Resolved
Place a copy of the piping diagram on vessel and in transfer procedures.
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 9 April 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 February 2009 Resolved
Find original Certificate Of Inspection (COI) and place on board vessel, if original can not be found request another original COI from cognizant Officer in Charge of Marine Inspections.
Action required: 705 - Other - as specified
Due 26 March 2009
Resolved 8 May 2009
Resolution: Printed and sent new copy.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 13 June 2008 Resolved
Failed to maintain valid COI. Annual inspection was scheduled outside the period(s) specified in 46CFR31.10-17 and therfore endorsed by the CG MI approximately 40 days late.
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 June 2008
Resolved 13 June 2008
Resolution: Inspection conducted and enforcement action pends.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 10 May 2007 Resolved
Replace/repair fuel hose on cargo pump engine in way of fuel oil leak.
Condition: Unknown
Due 10 May 2007
Resolved 10 May 2007
Resolution: Replaced fuel hose.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 15 March 2007 Resolved
Vessel shall conduct NO cargo operations until permanant repairs are made to leak in #2S cargo tank. Repairs to be made to the satisfaction of attending CG marine inspector.
Action required: 705 - Other - as specified
Resolved 13 July 2008
Resolution: Permanent repair completed.
Documentation › Certificates/Documents › Certificate of Financial Responsibility
Issued 3 February 2005 Resolved
Found Certificate of Financial Responsibility expired (25NOV04).
Due 3 March 2005
Resolved 4 February 2005
Resolution: applied for and received new COFR.
Deck/Cargo › Holds/Tanks
Issued 3 February 2004 Resolved
Replace flame screen, aft port stern slop tank ullage opening. LEGACY COMPONENT DESC: Flame Arrester
Condition: Unknown
Due 3 February 2004
Resolved 3 February 2004
Resolution: Replaced with new.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 February 2004 Resolved
Owners of the barge failed to have the annual inspection conducted for the previous two years.
Due 3 February 2004
Resolved 3 February 2004
Resolution: MSO Louisville inspector conducted satisfactory inspection of barge.
Construction/Loadline
Issued 23 July 1999 Resolved
Effect permanent repairs to the approximate 1.5 inch fracture in the side shell plating of #2 cargo tank to the satisfaction of the attending marine inspector. Temporary repairs shall be maintained and no further cargo may be loaded until permanent repairs have been completed.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Deck/Cargo
Issued 25 February 1999 Resolved
REPLACE MISSING HOLD DOWN (WING NUT) ON #3 PORT CARGO TANK ULLAGE OPENING.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Deck/Cargo
Issued 25 February 1999 Resolved
PROPERLY LABEL ALL CARGO TANKS.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Deck/Cargo
Issued 25 February 1999 Resolved
PLUG CARGO PUMP VENT LINE.(DISCHARGE SIDE)
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Deck/Cargo
Issued 25 February 1999 Resolved
Replace torn flame screen on stern void lube oil tank P/V valve.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Deck/Cargo
Issued 25 February 1999 Resolved
PROPERLY PACK ALL CARGO TANK REMOTE OPERATED VALVES.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Deck/Cargo
Issued 25 February 1999 Resolved
PLUG EXPOSED GATE OPENING ON MOBIL 477 DECK LUBE OIL TANK DRAIN VALVE.
Condition: Unknown
Due 25 February 1999
Resolved 25 February 1999
Construction/Loadline
Issued 17 December 1996 Resolved
Make permanent repairs to leaking side shell plating in way of no. 3 starboard cargo tank to the satisfaction of the attending USCG Marine Inspector prior to the loading of cargo but no later than 17 January 1997.
Condition: Unknown
Due 17 December 1996
Resolved 17 December 1996
Deck/Cargo
Issued 5 March 1992 Resolved
Replace missing bolts and nuts, and tighten all loose bolts and nuts on allbutterworth openings as required by 33CFR155.815(a)(5) prior to compliance date.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Documentation
Issued 5 March 1992 Resolved
Provide oil transfer procedures as required by 33CFR155.720 prior to compliance date.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Construction/Loadline
Issued 5 March 1992 Resolved
Replace gasket on hatch cover to stern void prior to compliance date.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Deck/Cargo
Issued 5 March 1992 Resolved
Replace flame screens in pressure-vacuum relief valves with fire resistant screen as required by 46CFR30.10-25 prior to compliance date.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Deck/Cargo
Issued 5 March 1992 Resolved
Replace missing bolts in each hole of each permanently connected flange on the cargo piping as required by 33CFR156.130(a)(4) prior to compliance date.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Deck/Cargo
Issued 5 March 1992 Resolved
Remove two oil transfer hoses that show deterioration of the outer cover through to the wire reinforcement as required by 33CFR156.170(c)(1)(i) prior to compliance date.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Deck/Cargo
Issued 5 March 1992 Resolved
Secure small discharge containment to deck under manifold of independent lube oil tank located on bow as required by 33CFR155.310(a)(1)(i) prior to compliance date.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Documentation
Issued 5 March 1992 Resolved
Provide a valid Certificate of Financial Responsibility (COFR) as required by 33CFR130.3(a) prior to moving the vessel, or transferring oil to, from, or within the vessel.
Condition: Unknown
Due 6 March 1992
Resolved 6 March 1992
Deck/Cargo
Issued 5 March 1992 Resolved
Mark all oil transfer hoses with the maximum allowable working pressure (MAWP) and the words "OIL SERVICE" as required by 33CFR155.800 prior to compliance date.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Engineering
Issued 5 March 1992 Resolved
Install a flame screen in the opening of the gooseneck vent to the fuel tank as required by 46CFR56.50-85(a)(8) prior to compliance date.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Construction/Loadline
Issued 5 March 1992 Resolved
Repair cracks in the weldment attaching the stern "tow knees" to the sideshell plating on the transom prior to the compliance date.
Condition: Unknown
Due 5 March 1992
Resolved 5 March 1992
Deck/Cargo
Issued 20 March 1990 Resolved
MAKE PERMANENT REPAIRS TO THE CRACK BETWEEN #1 CARGO TANKS AND THE FORWARD RAKE AT THE NEXT GAS FREEING BUT NO LATER THAN THE COMPLIANCE DATE. THE #1 CARGO TANKS SHALL NOT BE USED UNTIL PERMANENT REPAIRS HAVE BEEN COMPLETED.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Deck/Cargo
Issued 9 March 1990 Resolved
PROVIDE PROPER VENTS WITH P/V VALVES FOR THE FORWARD AND AFT SLOP TANKS AT THE NEXT GAS FREEING OR DRYDOCKING BUT NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Engineering
Issued 9 March 1990 Resolved
MAKE PERMANENT REPAIRS TO THE DIESEL PUMP ENGINE FUEL RETURN LINE PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Construction/Loadline
Issued 9 March 1990 Resolved
REMOVE FUEL FROM THE FORWARD RAKE PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Deck/Cargo
Issued 9 March 1990 Resolved
PERMANENTLY MOUNT THE LUBE OIL PUMP MOTOR AT THE NEXT GAS FREEING OR DRYDOCKING BUT NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 9 March 1990
Resolved 9 March 1990
Deck/Cargo
Issued 8 March 1989 Resolved
PERMANENTLY MOUNT TWO DECK LUBE OIL TANKS AT THE NEXT DRYDOCKING OR NEXT GAS FREEING BUT NO LATER THAN THE COMPLIANCE DATE.
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989
Electrical
Issued 8 March 1989 Resolved
MAKE ALL ELECTRICAL SWITCHES, MOTORS AND CABLE RUNS EXPLOSION PROOF USING U.L. APPROVED EQUIPMENT PRIOR TO THE COMPLIANCE DATE.
Condition: Unknown
Due 8 March 1989
Resolved 8 March 1989

Source. US Coast Guard records through 23 August 2026, retrieved 5 September 2026. Vessels the Coast Guard classes as Barge or Towing Vessel. Coverage and known gaps.