Records from 1995 to 2009. Most recent: inspection, 16 December 2009.
Inspection history · 70
16 December 2009
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3651544
15 December 2009
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3651042
10 July 2009
Administrative Inspection · COE-Administrative
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3534110
25 April 2009
COE-Dockside
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3460806
20 April 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3456544
30 October 2008
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3354173
25 June 2008
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3245318
29 May 2008
ISPS III Exam · MARPOL Annex I Examination · Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3214424
13 May 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3205429
25 April 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3192213
23 April 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3192084
6 April 2008
Type not recorded
No type recorded · USCGC COBIA (WPB 87311) · USCG Heartland District (CGD-H) · Activity 3203164
17 March 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3167399
15 November 2007
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3099043
18 October 2007
Ballast Water Examination · COC-TVE Annual · ISPS II Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · PII Safety Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3082132
21 July 2007
PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3002265
13 July 2007
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2993926
22 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2936889
22 May 2007
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2940080
22 May 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2947641
13 May 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2929118
11 May 2007
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2926685
8 April 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2903800
6 April 2007
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2902803
19 March 2007
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2890821
8 March 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2884139
26 January 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2862445
18 January 2007
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2858255
4 January 2007
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2849950
26 October 2006
ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2809603
27 September 2006
ISPS II Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2788920
12 June 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2688269
4 May 2006
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2641263
5 April 2006
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2646037
29 March 2006
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2612273
8 March 2006
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2598456
10 November 2005
COC-TVE Annual · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2532514
9 November 2005
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2531943
21 October 2005
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2519514
25 September 2005
ISPS II Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2500052
26 April 2005
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2348982
27 December 2004
Random ISPS/MTSA/PSC
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2267952
2 December 2004
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2251784
30 October 2004
COC-TVE Renew
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2227593
30 May 2004
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2082352
11 May 2004
MTSA/ISPS Verification · Ballast Water Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2065119
8 January 2004
Administrative Inspection
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1978939
29 December 2003
Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1970519
1 November 2002
Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1699687
25 October 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1696006
29 October 2001
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 294918
15 September 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 293797
6 October 2000
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 282602
19 May 2000
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 515158
12 October 1999
Tank Vessel Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 789556
10 October 1999
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 433881
30 June 1999
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 439548
9 November 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 422477
16 October 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 421706
1 May 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 465638
28 October 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 409443
25 August 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 407070
22 August 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 407096
18 August 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 468210
6 February 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 499549
4 November 1996
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 396943
4 October 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 395855
17 November 1995
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 17776
17 November 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 166987
11 November 1995
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 384694
Engineering › Lubricating Oil Service System › Pump
Issued 16 December 2009
Resolved
The vessel reported a "loss of linkage from chain drive" resulting in a main lubricator shaft stoppage.
Action required: 17 - Rectify deficiencies prior to departure
Due 16 December 2009
Resolved 16 December 2009
Resolution: Received, reviewed, and accepted class report form Det [name withheld] stating the deficiency was rectified. The report stated: A thorough visual inspection and tests were carried out by the class surveyor with no defects noted.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 30 October 2008
Resolved
Span gas onboard the vessel is expired. No spares bottles on board the vessel.
Condition: Unknown
Due 6 November 2008
Resolved 30 October 2008
Resolution: Received copy of recepit of span gas. Deficiency has been cleared.
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 18 October 2007
Resolved
Temporary repairs made to the IGS scrubber venturi box, lower aft inside corner. Class to examine the condition of box and make repairs to the satisfaction of Class as needed.
Action required: 705 - Other - as specified
Due 18 November 2007
Resolved 2 November 2007
Resolution: Received class report attesting to repairs. Side shells were replaced with new ones.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 18 October 2007
Resolved
Fire brick inside of incinerator starting to fail, lower forward port corner. Class to examine the condition of the fire brick.
Action required: 705 - Other - as specified
Due 18 November 2007
Resolved 2 November 2007
Resolution: Received class report attesting to repairs. Bricks were replaced and covered additional with cement.
Engineering › Diesel Engine (propulsion-direct drive) › Camshaft
Issued 22 May 2007
Resolved
The vessel experienced a power loss while entering the Lower Mississippi River.
Action required: 705 - Other - as specified
Due 22 May 2007
Resolved 22 May 2007
Resolution: Received class report from Det Norske Veritas satisfying requirement.
Navigation › Collision/Grounding Avoidance › Radar
Issued 8 April 2007
Resolved
Vessel requested deviation from the rules to enter the lower Mississippi river with an inoperable radar.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 April 2007
Resolution: After review of the tech. report from [name withheld], PSC/ Arrivals Branch approved the rescission of restriction and cleared the deficiency.
Deck/Cargo › Mooring/Anchoring › Anchor
Issued 8 March 2007
Resolved
Vessel is missing one (1) of two (2) required anchors. Make repairs to class. Submit class report upon completion.
Action required: 705 - Other - as specified
Due 16 March 2007
Resolved 19 March 2007
Resolution: Received a Letter of Class stating that a second anchor has been provided.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 8 March 2007
Resolved
Vessel reported a ARPA system error on their 3cm radar. Vessel must make repairs and submit a class report attesting to proper operation of the radar prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 March 2007
Resolution: Received tech report attesting to proper operation.
Navigation › Collision/Grounding Avoidance › Radar
Issued 26 January 2007
Resolved
Vsl has inop secondary radar. Vsl must submit tech report prior to departure.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2007
Resolution: Received sat tech report.
Navigation › Collision/Grounding Avoidance › Automatic Radar Plotting Aid (ARPA)
Issued 18 January 2007
Resolved
3cm Radar not working properly, Parts ordered and radar is to be repaired inport
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 January 2007
Resolution: Vessel had the parts and a tech from Mackay communications come on board vessel to make repairs. Radar is now working properly.
Deck/Cargo › Inert Gas System › Venting System
Issued 26 October 2006
Resolved
Mast Riser PV supply diaphragm (upper diaphragm housing, ambient portal leaking, indicating a worn diaphragm). New diaphragm on back order, to be installed within 30 days or next US port after sailing foreign, to the satisfaction to the attending CG marine inspector.
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 27 November 2006
Resolved 8 December 2006
Resolution: Vessel provided Class report of certified repairs.
Deck/Cargo › Inert Gas System › Venting System
Issued 26 October 2006
Resolved
Inert Gas Panel, (alarm function portion), defective CPU. CPU board replaced on 27 Oct06 by Scana Technician flown in from Norway. Panel tested satisfactory with minimum of 7 alarms and shutdowns tested: 1.Deck seal pump failure, 2.LP Scrubber , 3.Deck seal low level, 4.High temp blower shutdown,5. High O2 alarm, 6.Power failure to main regulating valve. 7.Boiler uptake valves.
Due 27 October 2006
Resolved 27 October 2006
Resolution: CPU Replaced
Navigation › Piloting/Steering › Swing Meter
Issued 4 May 2006
Resolved
Rudder indicator showed port while starboard, starboard while port. Class report must be submitted attesting to repairs and satisfactory operation of steering components.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 May 2006
Resolution: Received DNV class report attesting to repairs and full function steering test, all sat.
Deck/Cargo › Inert Gas System › Boiler Uptake
Issued 25 September 2005
Resolved
Prior to next U.S. Port, test entire IG system (boilers, valves, alarms, shutdowns, etc.) to the satisfaction of class. SOLAS 74/78 Amended 2001 11-2 Reg 62.
Action required: 15 - Rectify deficiencies by next port
Resolved 21 October 2005
Resolution: Received class report from Det Norske Veritas satisfying requirement.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 28 October 2004
Resolved
Vessel to complete outstanding condictions of Class for work to be done in Forepeak Tank, ballast Tank, and Longitudinal Framing, (Conditions of Class #'s 025, 034 & 045).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 November 2005
Resolved 9 November 2005
Resolution: Received Class report to the attestation of the repairs to all tanks .
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 28 October 2004
Resolved
Small soft patch discovered on sewage vacuum piping system, (located in engineroom, just above sewage holding tank).
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2005
Resolved 2 December 2004
Resolution: Received class survey report dated 05NOV04 attesting to the renewal of the sewage pipe spool from flange to flange. Repairs found satisfactory.
Fire Fighting › Fire Pumps
Issued 29 December 2003
Resolved
Soft patch found on discharge line of the #1 fire pump, vessel to make permanent and proper repairs to the satisfaction of the attending Class Surveyor.
Action required: 705 - Other - as specified
Due 29 February 2004
Resolved 8 January 2004
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 29 December 2003
Resolved
Ship Safety [name withheld] indicates that the vessel has missed dry-dock dates as required by SOLAS I/10. Prior to departing the port of New York, the vessel must provide proof from the certificate issuing authority that the vessel is in compliance with al dry-dock requirements.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 December 2003
Resolution: Vessel last three dry-dock were 26AUG1998, 20NOV1999 and 08MAY2002 as provide by DNV and now endorsed on Ship Safety Construction Certificate
Deck/Cargo
Issued 16 October 1998
Resolved
Repair and prove operation of the #1 inert gas blower prior to 16NOV98. Until repairs are complete, maintain onboard spare parts to completely overhaul working blower.
Condition: Unknown
Due 9 November 1998
Resolved 9 November 1998
Deck/Cargo
Issued 16 October 1998
Resolved
Provide starting interlock control to Oil Discharge Monitor for automatic valve control to prevent initiation of the opening of the discharge valve before the ODMC's monitoring is operational while in manual mode IAW 33 CFR157 APP. F/4.2.3 and 33 CFR 157 APP. F/4.5.
Condition: Unknown
Due 16 November 1998
Resolved 28 October 1998
Deck/Cargo
Issued 16 October 1998
Resolved
Prior to the next cargo operation in U.S. waters, provide class documentation of the cargo computer and software (specifically addressing the continuous "HULL STRESS WARNING").
Condition: Unknown
Due 20 October 1998
Resolved 20 October 1998
Deck/Cargo
Issued 16 October 1998
Resolved
Make the Oil Discharge Monitor and Control System capable of monitoring discharges into the sea while in the manual operation mode IAW 33 CFR 157.37 and 33 CFR 157 App. F, Footnote (6).
Condition: Unknown
Due 16 November 1998
Resolved 28 October 1998