MAURY USCG vessel records
← All vessels

SBI NO. 550

SBI NO. 550 is a 1956 freight barge. The Coast Guard has recorded 71 inspections since 1980, most recently in October 2014, along with 26 deficiencies and 1 casualty investigation in 2013.

Records from 1980 to 2014. Most recent: inspection, 21 October 2014.

Built
1956
Last inspected
21 October 2014
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 21 October 2014
…with no type recorded22
Operational controls None recorded without a removal date
Years with a record 32 calendar years (1980–2014)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-43267

Documentation record

Tonnage as PSIX records it1249 - Regulatory (Subpart C or D), Gross Ton
1249 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

JUDSON B Towing Vessel · MISLE 175533 · 10 June 2013 · activity 4619971

Inspection history · 71

21 October 2014 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5009522
7 April 2014 Administrative Inspection · MTSA Verification · Periodic Inspection · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4830674
10 June 2013 Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4616859
10 June 2013 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4619971
4 April 2012 MTSA Verification · Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 4279206
19 July 2010 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3800362
8 June 2010 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3760894
18 June 2009 Internal Structural Exam · Cargo Tank Internal · Drydock Exam · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3505973
30 July 2008 Periodic Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3283298
28 January 2008 Examination of Repairs · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3137758
13 August 2007 Internal Structural Exam · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3026990
20 June 2007 Permit to Proceed
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2967076
18 August 2006 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2752171
29 June 2006 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2695100
15 May 2006 COI Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2650079
16 November 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2535881
26 July 2005 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2440952
22 July 2005 Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2435431
8 April 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2329543
25 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2299283
5 January 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2269405
9 July 2004 Hull Examination · Internal Structural Exam · Cargo Tank Internal · Periodic Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2127231
17 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1966172
2 September 2003 Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1894261
27 March 2002 Hull Examination · Annual Inspection · Internal Structural Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1599904
14 June 2001 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1395757
6 July 2000 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 822692
10 September 1999 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 515442
28 June 1999 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1464194
4 May 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1437537
16 April 1998 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1109848
16 April 1998 COI Inspection · Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1122755
20 June 1997 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1386039
26 June 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1425765
19 July 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1396349
9 July 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 511556
24 January 1995 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 446827
8 December 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1142848
10 September 1994 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 447018
28 July 1994 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 866527
1 February 1994 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 852033
21 June 1993 Type not recorded
No type recorded · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 510324
22 December 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 686116
20 November 1992 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1137751
14 July 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 502228
16 June 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 454373
26 November 1991 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 944108
14 May 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 521358
28 March 1991 Examination of Repairs
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 934911
19 November 1990 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 925846
8 September 1990 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1222398
21 May 1990 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 449441
10 April 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1235983
10 February 1989 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 538159
31 January 1989 Deficiency Check
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 898102
19 January 1989 COI Inspection
Physical examination · MSO Paducah · USCG Heartland District (CGD-H) · Activity 894426
19 January 1989 Administrative
Administrative · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1338062
12 July 1988 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 508736
19 January 1988 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1013896
19 January 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1026025
17 December 1987 Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 454517
21 January 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013128
18 November 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1327113
2 July 1986 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1297908
15 November 1985 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991250
3 August 1985 Damage Survey
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 984107
24 January 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977936
9 October 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1282164
6 March 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972260
19 January 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273484
31 December 1980 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967644

Deficiency record · 26

Engineering › Fuel Oil Service System › Hose
Issued 7 April 2014 Resolved
Replace leaking fuel hose on cargo pump prime mover. Nonmetallic flexible hose must be complete with factory-assembled end fittings complying with SAE J1942. Due in 30 days.
Due 7 May 2014
Resolved 8 April 2014
Resolution: Fuel hose to return piping replaced.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 7 April 2014 Resolved
Vessel's hailing port shall be permanently marked as per vessel's certificate of documentation.
Condition: Improper Installation
Due 7 May 2014
Resolved 8 April 2014
Resolution: Vessel''''s old hailing port grinded off and new hailing port permanently marked and painted to reflect hailing port on current certificate of documentation.
Construction/Loadline › Markings › Load Line Mark
Issued 4 April 2012 Resolved
Vessel Restricted to Lakes, Bays, and Sounds & Rivers only due to Load Line not being current. 835 to be cleared when new COI is issued with LBS route or when current Load Line is issued/endorsed for Oceans route.
Action required: 705 - Other - as specified
Resolved 16 October 2012
Resolution: Cleared 835 due to vessel automatically inelegible for Oceans Route because of invalid Load Line Certificate.
Construction/Loadline › Hull › Girder
Issued 15 May 2006 Resolved
Crop and renew centerline girder to good material from rake to No. 1 cargo hatch as required by 46 CFR 30.01-10 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 18 June 2006
Resolved 29 June 2006
Resolution: Attended the vessel and verified that the centerline girder was cropped and renewed to good steel from the bow rake to the No. 1 cargo hatch as in accordance with 46 CFR 30.01-10.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2006 Resolved
Provide and install lagging for the exhaust piping on the cargo pump prime mover as required by 46 CFR 32-02-15 to the satisfaction of the attending marine inspector..
Action required: 705 - Other - as specified
Due 18 June 2006
Resolved 29 June 2006
Resolution: Attend the vessel and verified that the proper lagging for the exhaust piping on the cargo pump prime mover was installed in accordance with 46 CFR 32.02-15.
Engineering › Diesel Engine (auxiliary) › Block
Issued 15 May 2006 Resolved
Repair or replace the cover over the cargo pump prime mover as required by 46 CFR 32-35-5 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 18 June 2006
Resolved 29 June 2006
Resolution: Attended the vessel and verified that the cover to the pump prime mover was satisfactorily repaired as in accordance with 46 CFR 32.35-5.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2006 Resolved
Marked all cargo hatches in three inch letters " DANGER-KEEP OUT" as required by 46 CFR 35.05-15 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 18 June 2006
Resolved 29 June 2006
Resolution: Attended the vessel and verified that all cargo hatches were marked "DANGER-KEEP OUT" in accordance with 46 CFR 35.05-15.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 15 May 2006 Resolved
Conspicuously mark the emergency shutdown station for the cargo pump prime mover as required by 46 CFR 32-50-35 to the satisfaction of the attending marine inspector.
Action required: 705 - Other - as specified
Due 18 June 2006
Resolved 29 June 2006
Resolution: Attended the vessel and verified that the emergency engine shutdown station is clearly marked as in accordance with 46 CFR 32.50-35.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 22 July 2005 Resolved
Properly repair vent to diesel fuel tank.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 26 July 2005
Resolution: Diesel fuel tank vent was properly repaired.
Engineering › Fuel Oil Service System › Valve
Issued 22 July 2005 Resolved
Provide access to both shut-off valves on diesel fuel supply line.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 26 July 2005
Resolution: Proper access is now provided for both shut-off valves on diesel fuel supply line.
Accommodation/Occupational Safety › Ventilation › General
Issued 22 July 2005 Resolved
Properly repair ball-check vents on stern void and No. 3 port void.
Action required: 705 - Other - as specified
Due 22 August 2005
Resolved 26 July 2005
Resolution: Ball-check vents on stern void and No. 3 port void were replaced with proper vents.
Construction/Loadline › Structures
Issued 27 March 2002 Resolved
Renew 5 frame brackets as marked in the aft rake, 3 by frame 29S and 2 by frame 28P LEGACY COMPONENT DESC: Rake
Action required: 705 - Other - as specified
Resolved 5 April 2002
Construction/Loadline › Structures
Issued 27 March 2002 Resolved
Repair frame #5 on the port side shell LEGACY COMPONENT DESC: Rake
Action required: 705 - Other - as specified
Resolved 5 April 2002
Construction/Loadline › Structures
Issued 27 March 2002 Resolved
Repair fractured welds as marked. LEGACY COMPONENT DESC: Void
Action required: 705 - Other - as specified
Resolved 5 April 2002
Pollution Prevention/Response › Prevention Equipment
Issued 27 March 2002 Resolved
Renew the bottom of the port aft manifold cargo containment drip pan. Drip pan is wasted and has a hole in it. LEGACY COMPONENT DESC: Containment
Action required: 705 - Other - as specified
Resolved 5 April 2002
Documentation
Issued 19 July 1995 Resolved
SUBMIT TO THE USCG (G-MRO-2) MARPOL SHIPBOARD OIL EMERGENCY RESPONCE PLAN FOR APPROVAL I.A.W. REG. 26 OF MARPOL 73/78. UPON RECEIPT PROVIDE LOCAL OCMI WITH COPY TO CLEAR THIS.
Condition: Unknown
Due 19 September 1995
Resolved 14 September 1995
Documentation
Issued 19 July 1995 Resolved
_x001C_
Condition: Unknown
Due 19 September 1995
Resolved 31 August 1995
Construction/Loadline
Issued 20 November 1992 Resolved
NO. 1 PORT WING VOID - CROP AND RENEW BOTTOM LONGITUDINAL NEXT TO CENTERLINE IN 2ND BAY FORWARD OF AFT BULKHEAD IN DOUBLE BOTTOM; TO GOOD METAL.
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Construction/Loadline
Issued 20 November 1992 Resolved
NO. 1 PORTWING VOID - CROP AND RENEW BOTTOM LONGITUDINAL NEXT TO CENTERLINE FORWARD OF FALSE TRANSVERSE BULKHEAD IN DOUBLE BOTTOM; TO GOOD METAL.
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Construction/Loadline
Issued 20 November 1992 Resolved
NO. 1 PORTWING VOID - CROP AND RENEW OUTBOARD 1/2 OF WEB ABOVE FLAT BAR ON FORWARD VERTICAL SIDE SHELL FRAME OF 4TH BAY FORWARD OF FALSE TRANSVERSE BULKHEAD
Condition: Unknown
Due 20 November 1992
Resolved 20 November 1992
Deck/Cargo
Issued 19 January 1989 Resolved
STENCIL ALL CARGO HATCHES "DANGER KEEP OUT"
Condition: Unknown
Due 19 January 1989
Resolved 19 January 1989
Deck/Cargo
Issued 19 January 1989 Resolved
PROVIDE RECORD OF TEST OF CARGO TRANSFER SYSTEM IN ACCORDANCE WITH POLLUTION PREVENTION REGULATIONS
Condition: Unknown
Due 19 January 1989
Resolved 19 January 1989
Deck/Cargo
Issued 19 January 1989 Resolved
TEST CARGO HEATING SYS STEAM LINE RELIEF VALVE
Condition: Unknown
Due 19 January 1989
Resolved 19 January 1989
Deck/Cargo
Issued 19 January 1989 Resolved
MAKE NECESSARY REPAIRS TO ALL PV VALVES 1 THRU 5 CARGO TANKS
Condition: Unknown
Due 19 January 1989
Resolved 19 January 1989
Navigation
Issued 19 January 1988 Resolved
RENEW DAMAGED STARBOARD NAVIGATION LIGHT STANCHION AND SCREEN PRIOR TO OPERATING VESSEL AS A LEAD BARGE DURING HOURS OF DARKNESS.
Condition: Unknown
Due 19 January 1988
Resolved 19 January 1988
Electrical
Issued 15 November 1985 Resolved
PROVIDE TWO WATER TIGHT SWITCH BOXES TO REPLACE THE NON-WATERTIGHT SWITCH BOXES ON BOARD. REPAIRS TO BE COMPLETED NO LATER THAN 15DEC85.
Condition: Unknown
Due 15 November 1985
Resolved 15 November 1985

Casualty record · 1

10 June 2013Routine · role: Involved in a Marine Casualty · activity 4619971
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.