Records from 1996 to 2019. Most recent: inspection, 6 June 2019.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
6 June 2019
Administrative Inspection · Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6705786
16 August 2018
DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6510241
12 June 2017
COI Inspection · Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6173744
28 April 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5865392
9 September 2015
Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5726802
24 June 2014
Annual Inspection · DAPI Audit
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4897977
7 June 2012
COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 4336398
21 July 2009
Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3541421
15 January 2009
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3394896
17 June 2008
Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 3235801
25 June 2007
Hull Examination · Re-Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2710802
10 July 2006
Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2711298
17 July 2005
Type not recorded
No type recorded · Station Belle Isle · USCG Great Lakes District (CGD-GL) · Activity 2431474
18 May 2005
COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 2360248
18 May 2004
Hull Examination · Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 2154422
24 June 2003
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1825830
26 June 2002
Administrative Inspection
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1637109
23 May 2001
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1399634
11 May 2000
COI Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1361748
30 April 1999
Hull Examination
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1404760
23 October 1998
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1378499
15 October 1997
Re-Inspection
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1398777
16 May 1997
Administrative
Administrative · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 773773
22 November 1996
Hull Examination · Initial Certification
Physical examination · MSO DETROIT · USCG Great Lakes District (CGD-GL) · Activity 1414725
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 16 August 2018
Resolved
Complete proper repairs to leaking transom IWO starboard MDE exhaust penetration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 August 2018
Resolution: Received photograph indicating completion.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 August 2018
Resolved
Provide 2 additional day/night distress signals.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 August 2018
Resolved 27 September 2018
Resolution: Cleared
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 16 August 2018
Resolved
Complete servicing of fixed CO2 system.servici
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 August 2018
Resolved 27 September 2018
Resolution: Reviewed receipt; cleared.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 16 August 2018
No resolution recorded
Provide proof of monthly training program including completing and logging of drills.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2018 — due date passed with no resolution recorded
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 16 August 2018
Resolved
Provide CG approved 1st aid kit.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2018
Resolved 27 September 2018
Resolution: Viewed picture of new CG approved 1st aid kit.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 16 August 2018
Resolved
Provide current copy of charts, Coast Pilot and CG Light List that pertains to the vessels area of operations.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2018
Resolved 27 September 2018
Resolution: Viewed new copies; cleared.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 August 2018
No resolution recorded
Provide Emergency Broadcast Placard
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 August 2018 — due date passed with no resolution recorded
Resolution: Viewed; cleared.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 12 June 2017
No resolution recorded
Provide company policy statement regarding drug and alcohol use.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 July 2017 — due date passed with no resolution recorded
Communications › Radio Communications › VHF Radiotelephone
Issued 12 June 2017
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017
Resolved 16 August 2018
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 12 June 2017
No resolution recorded
Provide Great Lakes Agreement
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Permit, Other
Issued 12 June 2017
No resolution recorded
Provide marine radio operators permit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2017 — due date passed with no resolution recorded
Fire Fighting › Structural - Horizontal Zones › General
Issued 12 June 2017
No resolution recorded
Re-install insullation blanketing in engine room overhead port side aft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 July 2017 — due date passed with no resolution recorded
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 12 June 2017
Resolved
Provide proof of service for fixed CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2017
Resolved 16 June 2017
Resolution: Provided service receipt for fire service and cylinder renewal.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 12 June 2017
Resolved
Make permanent repairs to sternlight
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 June 2017
Resolved 16 June 2017
Resolution: Installed new navigation light.
Construction/Loadline › Hull › Bottom Plating
Issued 9 September 2015
Resolved
Forward compartment is making water through the butt block located on the port side aft.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 September 2015
Resolved 17 September 2015
Resolution: Noted proper repairs; boat was afloat with no water leaking around new butt block.
Engineering › Bilge Water Management System › Pump
Issued 9 September 2015
Resolved
Fixed power bilge pump is leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 17 September 2015
Resolution: Noted new pump installed and tested.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 9 September 2015
Resolved
Provide updated publications; US Coast Pilot and Light List.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 1 October 2015
Resolution: updated pubs obtained and placed on board.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 9 September 2015
Resolved
Provide proper bracket for B-II fire extinguisher near pilot station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 17 September 2015
Resolution: Noted new bracket.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 9 September 2015
Resolved
Designate DER per DAPI requirements.
Action required: 705 - Other - as specified
Due 7 October 2015
Resolved 28 September 2015
Resolution: Responsibilities of DER were reassigned to an administrative employee who is not enrolled in the drug testing program.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 9 September 2015
Resolved
Provide current Certificate of Documentation.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2015
Resolved 17 September 2015
Resolution: Noted canceled check and copy of application.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 24 June 2014
Resolved
Provide proof of enrollment in a Drug and Alcohol Program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2014
Resolved 7 July 2014
Resolution: Received compliance certificate.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 24 June 2014
Resolved
Provide employee list showing all employees within the program.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2015
Resolved 7 July 2014
Resolution: Received compliance document from Sea Test Inc.
Fire Fighting › Semiportable CO2 Fire Extinguishers › Service
Issued 24 June 2014
Resolved
Provide proof of servicing to all fire-fighting equipment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2015
Resolved 29 June 2014
Resolution: Received document from [name withheld] attesting to annual servicing of fixed and portable fire systems.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 7 June 2012
Resolved
Vessel had 2 B-II and 3 B-I dry chemical portable fire extinguishers. COI required 5 B-II portable fire extinguishers. Issued requirement to provide 3 B-II portable fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 June 2012
Resolution: [name withheld] called & reported he had the correct size & number of portable fire extinguishers on board and that he had faxed the servicing report to our office.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 7 June 2012
Resolved
SSDG would not start due to dead battery. SSDG is needed to provide power for fire pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 June 2012
Resolution: Owner charged battery and demonstrated operation of SSDG and fire pump during second visit.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 July 2009
Resolved
Several 110V AC outlets in main salon indicated reverse polarity and one had an open ground.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 17 June 2010
Resolution: Deficiencies corrected.
Engineering › Bilge Water Management System › Not Operational
Issued 21 July 2009
Resolved
Engine room bilge high level alarm inoperable.
Action required: 705 - Other - as specified
Resolved 17 June 2010
Resolution: High level alarm is now operable.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 17 June 2008
Resolved
Prvide DAPI documentation
Action required: 705 - Other - as specified
Resolved 17 July 2008
Resolution: DAPI information has been provided.
Personnel › Training › First Aid/CPR
Issued 17 June 2008
Resolved
Provide first aidCPR certificates.
Action required: 705 - Other - as specified
Resolved 15 January 2009
Resolution: corrected
Documentation › Logs/Records › Logbook (official)
Issued 17 June 2008
Resolved
Provide log book of drills.
Action required: 705 - Other - as specified
Resolved 15 January 2009
Resolution: corrected
Documentation › Certificates/Documents › Stability Letter
Issued 17 June 2008
Resolved
Provide a stability letter
Action required: 705 - Other - as specified
Resolved 17 July 2008
Resolution: Stability letter has been provided.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 26 June 2006
Resolved
Replace life line with 5/16" dark line and 3'-6' dark line for the ring buoy light with corrosion resistant clip.
Due 10 July 2006
Resolved 10 July 2006
Resolution: New line has been provided.
Communications › Audible Communications › Horn/Whistle
Issued 26 June 2006
Resolved
Repaire horn.
Due 10 July 2006
Resolved 10 July 2006
Resolution: Horn works properly.
Fire Fighting › Fire Bucket › Quantity
Issued 26 June 2006
Resolved
Provide two fire buckts and properly stencile them.
Due 10 July 2006
Resolved 12 July 2006
Resolution: Fire buckets have been provided to vessel.
Electrical › Electrical Distribution System (service) › Cable
Issued 26 June 2006
Resolved
Trace and remove any 120V and 32V wiring through out vessel.
Due 10 July 2006
Resolved 10 July 2006
Resolution: 120V and 32V wiring has been traced and removed. O/O will continue to trace and remove non-essential wires.
Construction/Loadline › Hull › Transverse Frame
Issued 26 June 2006
Resolved
Make perminant repaires to lateral frame at port chine and starboard lateral frame.
Due 10 July 2006
Resolved 10 July 2006
Resolution: Perminant repairs to lateral frame at port chine has been done. Repairs to the stbd fracture was temporarly repaired and until september 2006 when the vessel will be hauled out at end of operating season. Permanent repairs will then be made to the stbd.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 26 June 2006
Resolved
Replace STBD main and SSG through-hull valves.
Due 10 July 2006
Resolved 10 July 2006
Resolution: New through hulls have been installed.
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 26 June 2006
Resolved
Remove all non approved hoses through out vessel.
Due 10 July 2006
Resolved 10 July 2006
Resolution: All non approved hoses have been removed or replaced with approved hose.
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 26 June 2006
Resolved
Secure all non-vital through hulls to prevent water from entering into vessel.
Due 10 July 2006
Resolved 10 July 2006
Resolution: All non-vital through hulls have been secured.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 18 May 2005
Resolved
Portable fire extinguishers including the fixed CO2 bottle needs to be serviced by end of May
Due 31 May 2005
Resolved 1 June 2005
Resolution: All extinguishers have been serviced.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 May 2005
Resolved
Replace water light on one lifering.
Due 20 May 2005
Resolved 20 May 2005
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 18 May 2005
Resolved
Replace batteries in smoke detectors.
Due 20 May 2005
Resolved 1 June 2005
Lifesaving › Lifefloat › Lifeline
Issued 18 May 2005
Resolved
Place a corrosion resistant clip on approved size lifering.
Due 20 May 2005
Resolved 20 June 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 18 May 2005
Resolved
Remove all dead end wires.
Due 31 May 2005
Resolved 31 May 2005
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 May 2005
Resolved
Provide covers for batteries.
Due 20 May 2005
Resolved 20 June 2005
Engineering › Compressed Air System (control) › Valve
Issued 18 May 2005
Resolved
Fix air operated horn.
Due 31 May 2005
Resolved 31 May 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 18 May 2005
Resolved
Place light guards over lights in the engine room.
Due 20 May 2005
Resolved 20 June 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 May 2005
Resolved
Replace glass cover over fixed CO2 pull handle located on helm console.
Due 31 May 2005
Resolved 1 June 2005
Resolution: Replaced glass cover.
Lifesaving › Lifefloat › Markings
Issued 18 May 2005
Resolved
Mark all life jacket stowage areas with 1" letters that indicate number of life jackets.
Due 20 May 2005
Resolved 20 May 2005
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 18 May 2005
Resolved
Provide two portable flash lights.
Due 20 May 2005
Resolved 20 May 2005
Lifesaving
Issued 23 May 2001
Resolved
Replace battery in waterlight attached to buoyant apparatus and mark buoyant apparatus with vessel name.
Condition: Unknown
Due 23 May 2001
Resolved 6 June 2001
Fire Fighting
Issued 23 May 2001
Resolved
Provide 2 B-II portable fire extinguishers and mount on brackets.
Condition: Unknown
Due 23 May 2001
Resolved 6 June 2001
Fire Fighting
Issued 23 May 2001
Resolved
Provide new fire hose and nozzle.
Condition: Unknown
Due 23 May 2001
Resolved 6 June 2001
Engineering
Issued 23 May 2001
Resolved
Label emergency fuel oil shutdown stations.
Condition: Unknown
Due 23 May 2001
Resolved 6 June 2001
Lifesaving
Issued 23 May 2001
Resolved
Replace life ring with line attached.
Condition: Unknown
Due 23 May 2001
Resolved 6 June 2001
Unknown
Issued 22 November 1996
Resolved
ISSUED REQUIREMENT TO CONDUCT FIRE AND BOAT DRILLS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 22 November 1996
Resolved 22 November 1996