MAURY USCG vessel records Sign in
← All vessels

BALTIC BREEZE

BALTIC BREEZE is a 1977 freight ship. The Coast Guard has recorded 78 inspections since 1995, most recently in January 2008, along with 139 deficiencies — 10 with no resolution recorded — and 26 operational controls.

Records from 1995 to 2008. Most recent: operational control imposed, 25 January 2008.

Built
1977
Last inspected
25 January 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7624439 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP9445
432776
Flag
ANTIGUA AND BARBUDA
—
Maury page id
psix-432776

Inspections, by type

…with no type recorded42
…past their stated due date8
Years with a record 14 calendar years (1995–2008)
The 78 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it1286 - Convention (Subpart B), Net Ton
3928 - Displacement, Ton
2827 - Dead Weight, Ton
2139 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 78

25 January 2008 PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3135874
25 January 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3136318
18 January 2008 ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3132607
14 January 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3129946
10 January 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3128347
5 January 2008 ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3124338
5 January 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3125234
4 January 2008 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3124621
21 December 2007 PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3119187
20 December 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3118789
14 December 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3115958
13 December 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3115172
9 December 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3112250
9 December 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3112255
7 December 2007 PII Safety Exam · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3111362
7 December 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3111392
5 December 2007 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3109864
5 December 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3110096
1 December 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3107766
29 November 2007 PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3106376
24 November 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3103370
23 November 2007 PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3103063
16 November 2007 Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3099967
10 November 2007 PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3095993
6 November 2007 ISPS III Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3093774
27 October 2007 Ballast Water Examination · MARPOL Annex I Examination · PI Safety Exam · MARPOL Annex V Examination · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3087151
22 October 2007 PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3084409
5 October 2007 MARPOL Annex V Examination · Random ISPS/MTSA/PSC · MARPOL Annex I Examination · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3073934
6 July 2007 Deficiency Check · PII Safety Exam · ISPS III Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2983048
14 June 2007 MARPOL Annex I Examination · ISPS II Exam · MARPOL Annex V Examination · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2961217
14 June 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2961843
24 May 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2939098
18 May 2007 Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2935774
17 May 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2933119
26 April 2007 Type not recorded
No type recorded · Station Mayport · USCG Southeast District (CGD-SE) · Activity 2915986
25 April 2007 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 2915122
10 April 2007 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2904841
21 August 2006 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2755879
12 July 2006 Ballast Water Examination · ISPS II Exam · PII Safety Exam · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2710541
29 July 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2443915
24 July 2005 ISPS III Exam · Ballast Water Examination · MARPOL Annex I Examination · PII Safety Exam · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2434713
22 July 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2435402
21 July 2005 Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2434466
18 June 2005 In-Service Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2393813
16 May 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2358940
13 May 2005 Random ISPS/MTSA/PSC
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2356514
8 February 2005 Ballast Water Examination · ISPS III Exam · PII Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2288522
13 January 2005 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2275059
20 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2244933
9 November 2004 Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2239296
29 September 2004 Administrative Inspection
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2208506
17 August 2004 PI Safety Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2168414
2 July 2004 ISPS II Exam
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2118875
11 March 2004 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 2022488
2 December 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1957195
30 September 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1917136
22 April 2003 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1778155
16 September 2002 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1675949
2 July 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1639961
28 March 2002 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1598471
26 February 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1489380
8 February 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1485120
7 February 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1486200
15 January 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1494947
5 January 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 285831
29 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 282628
3 January 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 723238
27 December 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 436015
3 December 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 167950
25 July 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 431061
14 May 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 428819
24 November 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 423018
2 December 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 410449
6 October 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 408310
4 November 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 510226
1 June 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 527274
2 January 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 386629
10 November 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 385098

Deficiency record · 139

Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 24 January 2008 Resolved
Vessel has two main generators & 1 emergency generator - #1 generator & #3 generator not fully operational; prime movers operate, but generators cannot put power to the switchboard. Per SOLAS 60 II /26 emergency source of power is required. Per statements from attending technician, emergency generator had been inoperative for approx 1 week (prior to previous departure from Jacksonville).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 August 2008
Resolution: Rec''d final report from PMA surveyor attesting to proper operation of 1 & 2 SSDGs & EDG.
Construction/Loadline › Structures › Superstructure
Issued 24 January 2008 No resolution recorded
Noted several hatches with faulty gaskets & inability to seal watertight/weather tight. Chalk test all hatches to satisfaction of Administration, To the Flag state
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 24 January 2008 No resolution recorded
A60 boundary surrounding emergency generator space has exhaust pipe penetrating bulkhead / boundary is compromised To the satisfaction of the Administration
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Fire Fighting › Fire Main › Valves
Issued 24 January 2008 Resolved
Severe wastage #4 valve on firefighting main (in Main Engine Room), To the satisfaction of the Administration
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2008
Resolution: Confirmed renewed valve in presence of PMA surveyor.
Construction/Loadline › Hull › Transverse Frame
Issued 24 January 2008 Resolved
Damage/wastage in vessel is so severe as to call into question overall structural seaworthiness of vessel. To the satisfaction of the Administration
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 8 August 2008
Resolution: Rec''d report from PMA surveyor attesting to temporary repairs and authorizing 1-way trip to drydock.
Construction/Loadline › Hull › Transverse Frame
Issued 18 January 2008 No resolution recorded
3 bent vertical Frames in the vicenity of the emergency generator. Solas 60 I/II
Action required: 705 - Other - as specified
Due 23 February 2008 — due date passed with no resolution recorded
Construction/Loadline › Hull › Transverse Frame
Issued 18 January 2008 No resolution recorded
4 bent frames and 2 possible cracked welds in the vicinity of the steering gear room, Also there is heavy corrosion overhead which corresponds with the main house on the deck. SOLAS 60 I/II
Action required: 705 - Other - as specified
Due 23 February 2008 — due date passed with no resolution recorded
Construction/Loadline › Hull › Transverse Frame
Issued 18 January 2008 No resolution recorded
2 bent frames in the storage room adjacent to the engine control room. SOLAS 60 I/II
Action required: 705 - Other - as specified
Due 23 February 2008 — due date passed with no resolution recorded
Construction/Loadline › Hull › Transverse Frame
Issued 18 January 2008 No resolution recorded
6 bent frames in the engine control room, 2 possible craked welds. SOLAS 60 I/II
Action required: 705 - Other - as specified
Due 23 February 2008 — due date passed with no resolution recorded
Lifesaving › Launching Appliances › Davit
Issued 21 December 2007 Resolved
During launch of starboard lifeboat: 1aft deck sheave seized; 1 aft deck sheave broke free from deck; 1 forward sheave bent approximately 45degrees. Davit is currently in-operative & lifeboat may have additional damage. Rectify prior to departure to satisfaction of Flag.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 December 2007
Resolution: Received report from Panama the repairs were completed. See narrative
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 7 December 2007 Resolved
Safety Management Plan explains responsibility of Master regarding implementation of Plan aboard vessel; however, Master is unclear of those responsibilities. Though plan requires Master to submit improvements to company, Master said that was not his responsibility. Non-Conformity Report is in English-but working language is Russian - officers are not using form.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2007
Resolution: Panama to conduct external audit NLT 3rd week of December 2007.
Operations/Management › Vessel Safety Management › Reports and Analysis
Issued 7 December 2007 Resolved
Echo depth sounder in-op for over 2 weeks, yet no NCR filed. Master had no record of any NCRs that had been filed with company. Master and [name withheld] could not identify section of Safety Management Plan which explains when/how to file NCRs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2007
Resolution: Panama to conduct external audit NLT 3rd week of December 2007.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 7 December 2007 Resolved
Company has not ensured all personnel involved in Safety Management System have an adequate understanding of relevant rules, regulations, codes and guidelines. Master & chief Mate displayed inadeuate knowledge of Safety Management System.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 December 2007
Resolution: Panama to conduct external audit NLT 3rd week of December 2007.
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 23 November 2007 No resolution recorded
Starboard bridge wing: Ladder to the top of the house is severely corroded at the bottom bracket
Action required: 705 - Other - as specified
Due 23 December 2007 — due date passed with no resolution recorded
Navigation › Collision/Grounding Avoidance › Echo-sounding Device Recorder
Issued 23 November 2007 Resolved
Printer for Echo Depth Sounder is out of paper, replace or request letter of deviation prior to departure. 30Nov2007 Vessel received paper however Echo Depth Sounder is still non-operational. Extended deficiency, vessel is still required to submit an LOD request until satisfactory repairs have been made.
Action required: 705 - Other - as specified
Due 10 December 2007
Resolved 14 January 2008
Resolution: The vessel had seacoast electronics install new Furno FE-700 navigational echo sounder. Sector Jacksonville commmand center received tech report on 13JAN08. Copy of report scanned into MISLE(Baltic B.pdf)
Construction/Loadline › Hull › Hull Plating
Issued 23 November 2007 No resolution recorded
Multiple hull insets 1) On Stem 2) On Stern- Port corner of the transom 3) Hole in Rub Rail on port quarter, internals need to be examined
Action required: 705 - Other - as specified
Due 23 December 2007 — due date passed with no resolution recorded
Documentation › Certificates/Documents › Minimum Safe Manning Document
Issued 10 November 2007 Resolved
Vessel is crewed for 2 watch system based on short route (less than 600NM); however, ports of call are typically short in duration. It is questionable whether master and watchkeeping personnel can consistently meet rest reequirements of STCW.
Action required: 705 - Other - as specified
Due 24 November 2007
Resolved 30 November 2007
Resolution: Flag has not altered Minimum Safe Manning document - but has instructed company to temporarily add additional deck officer to assist in addressing maintenance issues.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 6 November 2007 Resolved
Fire Control Plan does not correspond with observed locations of fire and lifesaving equipment. In addition to deficiency 2030 noted in USCG activity 3087151 on 27 Oct 2007, the following discrepancies exist: 1) Location of fire control plan on the main deck does not correspond with observed locations on port and starboard main deck. 2) Locations of the fire hoses.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 December 2007
Resolved 5 December 2007
Resolution: Flag State report states fire control plan has been corrected
Fire Fighting › Fire Main › Condition
Issued 6 November 2007 Resolved
Fire fighting equipment not properly maintained: 1) Exterior fire hydrant connection gasket on port side [name withheld] severely wasted and rotted. 2) Exterior fire hydrant piping on starboard side Officers’ Deck shows signs of soft patching. Thick layer of paint makes determination of presence of soft patches difficult. 3) Three fire main piping mounting brackets on starboard side missing/broken
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 December 2007
Resolved 5 December 2007
Resolution: Flag State report states fire hydrants have repaired
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 October 2007 Resolved
Self-closing door penetrating Class "A" division from Pilothouse Deck to [name withheld] does not latch. SOLAS 60 II/38(e).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 6 November 2007
Resolution: CG PSC O witnessed repair.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 27 October 2007 Resolved
Fire Control Plan does not indicate Class "A" divisions surrounding bridge control station. SOLAS 74 (Amend) II-2/15.2.4
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 27 November 2007
Resolved 5 December 2007
Resolution: Flag State report states fire control plan has been corrected
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 October 2007 Resolved
Shock and electrical hazards present: 1) Exposed wire dead-ends above Number 1 ship's service generator not insulated. 2) Front door to electric panel box for main engine seawater cooling pump missign and cables exposed around perimeter of box. SOLAS 60 II/27(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 5 December 2007
Resolution: Flag State report states hazards have removed and repaired
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 27 October 2007 Resolved
Oil Transfer Procedures missing. Vessel prohibited from transfering or lightering oil internally or externally until CG verifies presence of Oil Transfer Procedures onboard. Vessel produced Transfer Procedures 10 Nov; however, procedures did not adequately address certain elements of 33CFR155.720. Amended def to be due 24Nov.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 November 2007
Resolved 23 November 2007
Resolution: Vessels transfer procedures now follow 33CFR155.720
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 27 October 2007 Resolved
Personnel not properly trained in ship's Safety Management System and Environmental Protection Policy for bunkering: See Activity 3087151 for details. ISM A/6.4
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2007
Resolved 27 November 2007
Resolution: External audit conducted 26Oct07 - 3 non-conformities.
Operations/Management › Drills/Instruction › Fire
Issued 27 October 2007 No resolution recorded
During fire drill, crew did not check fire-fighter's outfits to determine proper outfitting: see Activity 3087151 for details. SOLAS 74 (Amend) III/19.3.4.2.3 and II-2/10.1.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 November 2007 — due date passed with no resolution recorded
Operations/Management › Drills/Instruction › Abandon Ship
Issued 27 October 2007 Resolved
Abandon ship drill not conducted in accordance with recommendations listed in MSC/Circular.1136, with due regard to personnel safety: See Activity 3087151 for details. SOLAS 74 (Amend) III/19.3.3.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 27 October 2007
Resolution: Witnessed satisfactory abandon ship drill and operation of starboard lifeboat in water. Master altered current procedures to maximize safety of crew by testing launching appliances prior to placement of crew on boat lifeboat being lowered.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 22 October 2007 Resolved
Relief master did not have STCW endorsement from Flag-state, nor did he have receipt of application. Off-going master was not scheduled to sail with vessel. Without properly licensed/endorsed master, vessel did not meet staffing requirements of Minimum Safe Manning document.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2007
Resolution: Approx 1815, SCC received fax of relief Master''s Panama receipt of application.
Operations/Management › Vessel Safety Management › Resources and Personnel
Issued 22 October 2007 Resolved
SMS at company level is apparently not effectively implemented with regards to staffing vessel in accordance with STCW. Recommend external audit.
Action required: 705 - Other - as specified
Due 5 November 2007
Resolved 5 November 2007
Resolution: Rec''''d audit report - attached to MISLE Activity # 3073934.
Fire Fighting › Fire Pumps › Location
Issued 22 October 2007 Resolved
SOLAS 60 II/65: "In a cargo ship of 1000 tons and upwards, if a fire in any one compartment could put all the pumps out of action, there must be an alternative means of providing water for fire fighting. In a cargo ship of 2000 tons and upwards this alternative means shall be a fixed emergency pump independently driven." Vessel has 2 fire pumps, but both are located in E/R.
Action required: 705 - Other - as specified
Due 5 December 2007
Resolved 6 December 2007
Resolution: Panama req''d temp emergency firepump on board NLT 5Dec - permanent emergency firepump to be installed at next dry dock.
Electrical › Electric Generation Source (emergency) › Generator
Issued 5 October 2007 Resolved
EDG malfunctioning: prime mover operates; however, power level to emergency switchboard fluctuates under load. C/E reported increased fluctuations in Voltage & Amps under load, such that emergency power is insufficient for required circuits. SOLAS 60 II-2 / 26(b); to satisfaction of Adminsitration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2007
Resolution: Reviewed Administration report attesting to satisfactory repairs and testing: deficiency was result of faulty generator governor solenoid.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 5 October 2007 Resolved
C/E, 2/E & 2/O all had expired Flag-state receipts of application for STCW endorsements. Without properly licensed C/E 2/E, vessel did not meet staffing req'ts of Minimum Safe Manning document. To satisfaction of Administration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2007
Resolution: Reviewed Administration report attesting to presence of STCW certificates on board: C/E''''''''s endorsement had been lost in mail; 2/E endorsement on board; 2/O debarked vessel in Jacksonville for repatriation.
Construction/Loadline › Hull › Bottom Plating
Issued 5 October 2007 Resolved
Hull watertight integrity compromised: E/R bilge in vicinity of frame 15, approx 3 feet port of centerline, hull has hole approx 2" in diameter. Master had affected temporary repair with 10" x 15" cement patch (on 20 Sept 2007). SOLAS 74 Amend I /11; to satisfaction of Administration.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2007
Resolution: Reviewed Administration report attesting to satisfactory repairs and testing: Hull plating cofferdammed and replaced with insert; surrounding plating gauged by NDT and found satisfactory; weld inspected satisfactory.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 5 October 2007 Resolved
#1 Fuel Tank: plating fractured in cargo hold approx 1 meter starboard of enterline in vicinity of Frame 97. Fuel leaking into cargo hold. SOLAS 74 Amend I /11; to satisfaction of Administration.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2007
Resolution: Reviewed Administration report attesting to satisfactory repairs and testing: plating cropped and renewed; surrounding plating gauged by NDT; weld tested; all satisfactory.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 5 October 2007 Resolved
Based on def's 0220, 1430, 0938, 0940, and including multiple reports concerning all from vessel to company, Safety Management System does not appear to be effectively implemented at the company level. Recommend external audit. Flag to provide CG report detailing course of action prior to departure. ISM A / 3.3, A / 6.2, A / 10.2.3; to satisfaction of Administration.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2007
Resolution: Reviewed Administration report requiring extrinsic audit of Company by RO and Administration ISM audit of vessel as condition of Registry.
Deck/Cargo › Ballast › Tank
Issued 5 October 2007 Resolved
Ref def 0938, when hole discovered in hull, Master's damage control procedures included pumping oily water from bilge into Ballast Water Tank #2 Starboard. Vessel must develop plan that will adequately address ballasting needs, contamination of ballast pumping and piping systems, and prevent discharge of oil. MARPOL 73/78 (2006 Consol.) I / 15; to satisfaction of Administration.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 October 2007
Resolution: Reviewed Administration report attesting to discharge of ballast water to shore and testing of ballast piping and pumps for oil residue; no residue detected; ballast system satisfactory.
Documentation › Safety/Response Plans/Programs › Ballast Water Management Plan
Issued 5 October 2007 No resolution recorded
BWM plan not updated to include current U.S. BWM req'ts & U.S. reporting req'ts.
Action required: 705 - Other - as specified
Due 6 November 2007 — due date passed with no resolution recorded
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 5 October 2007 Resolved
Warning statement absent from manuevering fact sheet.
Action required: 705 - Other - as specified
Due 6 November 2007
Resolved 30 November 2007
Construction/Loadline › Penetrations › Gasket
Issued 14 June 2007 Resolved
Emergency escape hatch (steering gear space to deck) is not sealing completely: From steering gear room there is a clearly visible beam of light coming from the hatch when it is closed and dogged.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 6 July 2007
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 14 June 2007 Resolved
Port lifeboat: wooden tiller is split at the connecting point to the rudder. Repair to the satisfaction of Class.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 15 June 2007
Resolved 6 July 2007
Engineering › Generator (propulsion-electric) › Winding
Issued 14 June 2007 Resolved
#1 Generator inoperative due to broken windings: Non Conformity Report has been filed, and replacement parts are scheduled for delivery in Miami
Action required: 705 - Other - as specified
Due 22 June 2007
Resolved 6 July 2007
Fire Fighting › Structural - A Class Divisions › Doors
Issued 14 June 2007 Resolved
Fire door: door between emergency generator space and maine engine room (in Class A boundary) was tied back in open position.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 15 June 2007
Resolution: Def. corrected on the spot
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 14 June 2007 Resolved
Fire control PlanL Fire Control Plan is not "permanently exhibited fo the guidance of the ship's officer's." Plan is stowed on either side of the house in weather-tight containers for emergency access; however, the plan is posted no where else. Additionally, the approved plan states "Sheet 1 of 2", however, sheet 2 is unavailable. Correct to the satisfaction of Class.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 15 June 2007
Resolved 6 July 2007
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 14 June 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 15 June 2007
Resolved 15 June 2007
Resolution: Cheif Engineer received a Receipt of Application from the Flag State.
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 14 June 2007 Resolved
Due to multiple mariners arriving without valid flag state endorsements, company has not fully implemented this portion of the SMS system recommend external audit.
Action required: 705 - Other - as specified
Due 15 July 2007
Resolved 6 July 2007
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 21 August 2006 Resolved
Vessel arrived early in US waters. Vsl failed to update its ANOA on time. Vsl ordered to update the ANOA with the NVMC.
Due 21 September 2006
Resolved 21 August 2006
Resolution: Vessel updated its arrival time at 1330 on 21AUG06. The updated arrival time became 1000 on 21AUG06.
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 12 July 2006 Resolved
Provide Flag State endorsement for Master, Chief Engineer, and Second Engineer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2006
Documentation › Safety/Response Plans/Programs › SOPEP
Issued 12 July 2006 Resolved
Provide Approval Letter for SOPEP
Action required: 705 - Other - as specified
Resolved 5 August 2006
Operations/Management › Vessel Safety Management › Documentation Maintenance/Control
Issued 12 July 2006 Resolved
Provide current certificate of registry under Baltic Breeze.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2006
Fire Fighting › International Shore Connection › Gasket
Issued 24 July 2005 Resolved
Provide Gasket for International Shore Connection.
Action required: 705 - Other - as specified
Due 7 August 2005
Resolved 3 August 2005
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 24 July 2005 Resolved
Replace expired charges for line throwing apparatus.
Action required: 705 - Other - as specified
Due 31 July 2005
Resolved 3 August 2005
Electrical › Electric Generation Source (emergency) › Generator
Issued 24 July 2005 Resolved
Make starting battery arrangment for Emergency Generator permanent.
Action required: 705 - Other - as specified
Due 7 August 2005
Resolved 3 August 2005
Lifesaving › Rocket Parachute Flares › General
Issued 21 July 2005 Resolved
Eight of Twelve distress flares are expired. Provide new distress flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2005
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 21 July 2005 Resolved
Vessel does not have current edition of charts onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2005
Lifesaving › Line-Throwing Appliances › Projectiles
Issued 21 July 2005 Resolved
Vessels line throwing rockets are expired.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 July 2005
Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 21 July 2005 Resolved
Provide proof of application for flag state endorcement for Master [name withheld] and Second Engineer.
Due 29 July 2005
Resolved 29 July 2005
Resolution: Recieved fax copies of application for flag state endorcement (Panama).
Operations/Management › Mandatory Ship Reporting Systems › Entry Report
Issued 21 July 2005 Resolved
Vessel failed to provide correct information on thier Advanced Notice of Arrival. ANOA. The did not provide classification society, owner, or issung agency.
Action required: 705 - Other - as specified
Resolved 21 July 2005
Documentation › Logs/Records › Ballast Water Reporting Form
Issued 13 May 2005 Resolved
Vessel has not provided mandatory ballast water management reports.
Condition: Improper/Lack of Maintenance
Due 13 May 2005
Resolved 31 May 2005
Resolution: Vessel is currently meeting BWM reporting requirements.
Engineering › Bilge Water Management System › Not Operational
Issued 8 February 2005 Resolved
The bilge alarms in the engine room were not operative. Unable to test bilge alarms. Solas 60 1/10.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Fire Fighting › Fire Main › Condition
Issued 8 February 2005 Resolved
There was a crack in the firemain fwd on the main deck on the port side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 8 February 2005 Resolved
Classification marking on the loadline were not as per the loadline certificate.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Deck/Cargo › Holds/Tanks › Coaming
Issued 8 February 2005 Resolved
hatch gaskets were missing on sections of the hacth covers and the coaming along the holds are corrode and wasted in some areas.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 8 February 2005 Resolved
Not endorsed by class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Documentation › Certificates/Documents › IOPP Certificate
Issued 8 February 2005 Resolved
IOPP not endorsed by class.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Engineering › Steering Gear System › Pump
Issued 8 February 2005 Resolved
Number 2 pump can not be energized form the bridge and the number 1 pump can not be energized from the steering gear room. Solas 60 II/29 (2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Lifesaving › Launching Appliances › Falls
Issued 8 February 2005 Resolved
The falls appeared to worn and have not been replaced nor have they been end for ended. The vessel claimed a renewal date of 11/24/03, but there is no record of the renewal.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Personnel › Certificates/Documents/Licenses › License, Chief Engineer
Issued 8 February 2005 Resolved
The license is not endorsed by flag state. The endorsement expired 17 JAN 04.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 8 February 2005 Resolved
The licenses is not endorsed by flag state.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 February 2005 Resolved
Did not have a qualified oiler onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Personnel › Certificates/Documents/Licenses › License, Second Assistant Engineer
Issued 8 February 2005 Resolved
The license was not endorsed by flag state. The license expired 03 JAN 04.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 8 February 2005 Resolved
There was no ballast water management plan onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 8 February 2005 Resolved
The owner of the vessel was not addressing crew issues in a timely manner. There were several licenses of the that were not endorsed by flag state.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Operations/Management › Vessel Safety Management › Master's Responsiblity/Authority
Issued 8 February 2005 Resolved
The master did not ensure the ceritficates were endorsed as per the anniversity date. Teh master also did not ensure the vessel had licensed and qualified crewmembers onboard. The master made several trips without the safe min. manning.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2005
Engineering › Fuel Oil Service System › Piping
Issued 17 August 2004 Resolved
Improper fuel lines on suction side of fuel filter on STBD generator. To satisfaction of Flag Rep.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 August 2004
Engineering › Fuel Oil Service System › Hose
Issued 17 August 2004 Resolved
Inproper Fuel lines on Port generator iwo fuel filter. Relace with Proper fuel line to satisfaction of flag rep.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 August 2004
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 17 August 2004 Resolved
Suction line on Ows has Improper patch. Renew piping to satisfaction of flag rep.
Action required: 15 - Rectify deficiencies by next port
Resolved 20 August 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 17 August 2004 Resolved
Dead end wiring in paint locker. Rmove cable or terminate in a box. To the satisfaction of flag state Rep
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 20 August 2004
Construction/Loadline › Structures › Ventilators
Issued 17 August 2004 Resolved
Knife edge on stbd side engine room vent is wasted at the bottom. Crop and renew to satisfaction of flag rep.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 August 2004
Resolved 29 September 2004
Resolution: CORRECTED
Construction/Loadline › Structures › Superstructure
Issued 17 August 2004 Resolved
AC units improperly installed in bulkheads not allowing areas to be weathertight. Provide a solution to make areas weather tight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 September 2004
Resolved 29 September 2004
Resolution: CORRECTED
Lifesaving › Lifeboat Equipment
Issued 11 March 2004 Resolved
Lifeboat rations have lost their airtight seal (qty: 3). IAW SOLAS 74 AMD/ III/ 20/ ALL SHIPS CITE. Provide proof of purchase (receipt) prior to departure. LEGACY COMPONENT DESC: Food Ration
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2004
Resolved 17 March 2004
Engineering › Steering Gear System
Issued 11 March 2004 Resolved
Rudder Angle Indicator on bridge does not reflect actual position at the rudder post (deviation: 10 degrees). IAW SOLAS 60/ II/ 29 (a) (iv). Repair to the satisfaction of the certificate issuing authority prior to departure. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2004
Resolved 11 March 2004
Accommodation/Occupational Safety › Occupational Safety
Issued 11 March 2004 Resolved
Handrails iwo portside lifeboat deck are damaged. IAW ICLL 66/88/ ANNEX I/ 25 (2). LEGACY COMPONENT DESC: Deck Rail
Action required: 705 - Other - as specified
Due 11 April 2004
Resolved 17 March 2004
Lifesaving › Lifebuoys
Issued 11 March 2004 Resolved
Life Ring Buoys are damaged or excessively worn. IAW SOLAS 74 AMD/ III/ 20/ ALL SHIPS CITE.
Action required: 705 - Other - as specified
Due 11 April 2004
Resolved 11 March 2004
Electrical › Electrical Distribution System (service)
Issued 11 March 2004 Resolved
Exposed wiring in machinery spaces. IAW SOLAS 60/ II/ 27 LEGACY COMPONENT DESC: Wiring
Action required: 705 - Other - as specified
Due 11 April 2004
Resolved 17 March 2004
Lifesaving › Lifeboat
Issued 11 March 2004 Resolved
Lifeboat has damaged top rail (iwo lifeboat securing straps). IAW SOLAS 74 AMD/ III/ 20/ ALL SHIPS CITE
Action required: 705 - Other - as specified
Due 11 April 2004
Resolved 17 March 2004
Construction/Loadline › Markings
Issued 11 March 2004 Resolved
Load Line mark not iaw Load Line Certificate. IAW ICLL 66/88/ ANNEX I/ 9. ALSO, current cert. is expired.
Action required: 705 - Other - as specified
Due 11 April 2004
Resolved 17 March 2004
Construction/Loadline › Markings
Issued 30 September 2003 Resolved
Actual load line markings do not reflect markings specified on the Int'l Load Line Certificate (iaw ICLL 66/Annex I/4, 5, 7, & 8). Make permanent correction nlt 01NV03.
Due 1 November 2003
Resolved 10 December 2003
Resolution: Resolved via fax. See vessel unit file.
Documentation › Manuals/Policy Documentation
Issued 30 September 2003 Resolved
Stability book not approved (iaw SOLAS 60/II/19). Correct to the satisfaction of the certificate issuing authority nlt 01NOV03. LEGACY COMPONENT DESC: Stability Instructions
Action required: 705 - Other - as specified
Due 1 November 2003
Resolved 10 December 2003
Resolution: Resolved via fax. See vessel unit file.
Documentation › Safety/Response Plans/Programs
Issued 26 February 2002 Resolved
Rewrite the Oil Transfer Procedures to include procedures and diagrams for all oil transfer operations. LEGACY COMPONENT DESC: Oil Transfer Procedures
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Resolution: Corrected.
Documentation › Certificates/Documents
Issued 26 February 2002 Resolved
Provide Coast Guard with a Letter of Designation & Declaration of Inspection for oil transfer. 33 CFR 156.150. LEGACY COMPONENT DESC: Letter of Designation (oceanographic research)
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Resolution: Corrected, reviewed PIC letter and DOI.
Engineering › Steering Gear System
Issued 26 February 2002 Resolved
Prove correct alignment of rudder angle indicators between the bridge and aft steering/ LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Engineering › Compressed Air System (control)
Issued 26 February 2002 Resolved
Install fan cover on the portable fan near the compressor located in the engineroom. LEGACY COMPONENT DESC: Temp. install cooling fan
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Engineering › Generator (propulsion-electric)
Issued 26 February 2002 Resolved
Fix exhaust leak on port generator turbocharger and heat exchanger. LEGACY COMPONENT DESC: turbocharger and heat exchanger
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Fire Fighting › Fire Main
Issued 26 February 2002 Resolved
Repair soft patch from the firemain cross-over line. LEGACY COMPONENT DESC: Lines
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Resolution: Repaired, vessel to replace all of firemain on deck port and starboard.
Engineering › Compressed Air System (control)
Issued 26 February 2002 Resolved
Install safety guard on reefer compressor on the portside storage room. LEGACY COMPONENT DESC: Fan
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Pollution Prevention/Response › Prevention Equipment
Issued 26 February 2002 Resolved
Weld a new coaming around port bunkering station. LEGACY COMPONENT DESC: Coamings
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Resolution: Repaired.
Deck/Cargo › Holds/Tanks
Issued 26 February 2002 Resolved
Install flame screens on all deck fuel vents. LEGACY COMPONENT DESC: Ventilation Air Intake
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Deck/Cargo › Cargo Stowage
Issued 26 February 2002 Resolved
Prove proper operation of fwd cargo hole ventilation dampers. LEGACY COMPONENT DESC: Ventilation Dampers
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Lifesaving › Lifeboat
Issued 26 February 2002 Resolved
Renew lifelines on both port and starboard davit launched lifeboats. LEGACY COMPONENT DESC: Lifeline (becketed)
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Engineering › Steering Gear System
Issued 26 February 2002 Resolved
Provide steering gear instructions and display on bridge I.A.W. 33 CFR 164.35 LEGACY COMPONENT DESC: Steering Gear Instructions
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2002
Navigation
Issued 5 January 2001 Resolved
Provide International code of signals.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Deck/Cargo
Issued 5 January 2001 Resolved
Have class address securing and stability of portable generator on aft boatdeck.
Condition: Unknown
Due 11 January 2001
Resolved 11 January 2001
Navigation
Issued 5 January 2001 Resolved
Provide current Tidal current tables.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Navigation
Issued 5 January 2001 Resolved
Provide current International/Inland rules of the road.
Condition: Unknown
Due 12 January 2001
Resolved 12 January 2001
Fire Fighting
Issued 29 September 2000 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Documentation
Issued 29 September 2000 Resolved
HAVE CLASS ADDRESS DICREPANCIES BETWEEN LOADLINE CERTIFICATE AND ACTUAL PLIMSOL MARK, AND PROVIDE PERMANENT HULL REFERENCE LINE.
Condition: Unknown
Due 29 September 2000
Resolved 2 October 2000
Documentation
Issued 29 September 2000 Resolved
PROVIDE ORIGINAL COPY OF SAFE MANNING DOCUMENT ON BOARD.
Condition: Unknown
Due 6 November 2000
Resolved 6 November 2000
Fire Fighting
Issued 27 December 1999 Resolved
Prior to departure, provide a service certificate for the vessel's fixed CO2 fire-extinguishing system. Sercie report on board vessel indicates last servicing was conducted in November 1997.
Condition: Unknown
Due 27 December 1999
Resolved 3 January 2000
Lifesaving
Issued 27 December 1999 Resolved
Prior to departure, provide on board 3 portable GMDSS radioes.
Condition: Unknown
Due 27 December 1999
Resolved 3 January 2000
Engineering
Issued 27 December 1999 Resolved
Prior to departure, prove the proper operation of the vessel's oily water separator.
Condition: Unknown
Due 27 December 1999
Resolved 3 January 2000
Electrical
Issued 27 December 1999 Resolved
Prior to departure prove the proper operation of all 3 electrical generators.
Condition: Unknown
Due 27 December 1999
Resolved 3 January 2000
Electrical
Issued 24 November 1998 Resolved
REPLACE BROKEN RUBBER HOSE LEADING TO WATERTANK FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 24 November 1998 Resolved
PROVIDE ONBOARD A SOLAS TRAINING MANUAL FITTED FOR EQUIPMENT ONBOARD THIS VESSEL.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Lifesaving
Issued 24 November 1998 Resolved
PROVIDE SUITABLE CONTAINER FOR STORING ALL FOOD SUPPLY LOCATED AT PORT/STBDLIFE BOATS.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 24 November 1998 Resolved
PROVIDE OWNER'S NAME AND ADDRESS INCLUDING OPERATORS.
Condition: Unknown
Due 24 November 1998
Resolved 8 January 1999
Unknown
Issued 24 November 1998 Resolved
CLASS SOCIETY TO ADDRESS QUALITY OF GROSS TONNAGES.(ITC INDICATES 2139 AND SOLAS DOCS SHOW 898)
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 24 November 1998 Resolved
PROVIDE ON BOARD VALID SHIP'S SOLAS CERTIFICATES.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Unknown
Issued 24 November 1998 Resolved
PROVIDE CORRECT LLOYDS NUMBER FOR SUBJECT VESSEL.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 24 November 1998 Resolved
PROVIDE STATEMENT OF FACT FROM PRESENT CLASS SOCIETY THAT THEY HAVE BEEN DULY AUTHORIZED BY BUREAU OF VERITAS TO USE THEIR CERTIFICATES/FORMS.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 24 November 1998 Resolved
PROVIDE CARGO SECURING MANUAL AND CLASS SOCIETY APPROVAL FOR SUCH.
Condition: Unknown
Due 25 July 1999
Resolved 25 July 1999
Construction/Loadline
Issued 24 November 1998 Resolved
PAINT LOADLINE MARK IN CONTRASTING COLOR FROM SHIP'S HULL.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Navigation
Issued 24 November 1998 Resolved
PROVIDE REPORT FROM CLASS ADDRESSING RUDDER ANGLE INDICATOR AT BRIDGE NOT SYNCRO WITH THE INDICATOR IN STEERING ROOM.
Condition: Unknown
Due 25 July 1999
Resolved 25 July 1999
Engineering
Issued 24 November 1998 Resolved
MAKE PERMANENT REPAIRS TO OWS PUMP AND PROVIDE A REPORT FROM CLASS SOCIETY ATTESTING PROPER OPERATION OF SYSTEM.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Documentation
Issued 24 November 1998 Resolved
PROVIDE LINE PIPE DIAGRAM FOR OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Unknown
Issued 24 November 1998 Resolved
PROVIDE SUITABLE BRACKETS OR STOWAGE LOCATION FOR OXYGEN TANK AT PORT SIDE AFT.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Fire Fighting
Issued 24 November 1998 Resolved
LABEL SPRINKLER ISOLATION VALVE LEADING TO PAINT LOCKER.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Lifesaving
Issued 24 November 1998 Resolved
CONDUCT FIRE AND ABANDON SHIP DRILL TO THE SATISFACTION OF CLASS. PROVIDE REPORT TO USCG.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Lifesaving
Issued 24 November 1998 Resolved
PROVIDE CLAS REPORT ADDRESSING POOR CONDITION OF LIFEBOAT'S RELEASE UNIT. PULLIES NOT TURNING.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Fire Fighting
Issued 24 November 1998 Resolved
PROVIDE SPANNER WRENCHES FOR ALL FIRE FIGHTING SATIONS.
Condition: Unknown
Due 30 November 1998
Resolved 30 November 1998
Engineering
Issued 6 October 1997 Resolved
MAIN ENGINE COOLING LINE HAD A SOFT PATCH INSTALLED. REPAIR/RENEW AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Fire Fighting
Issued 6 October 1997 Resolved
PIN HOLE IN FIREMAIN PIPING, MAIN DECK STARBOARD SIDE JUST AFT OF THE LOADLINE MARK. REPAIR/RENEW AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 6 October 1997 Resolved
PORT LIFEBOAT CABELING IMPROPERLY RIGGED. CABELING WAS RAN OUTSIDE TWO SHEAVE GUARDS. REPAIR/RENEW AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 6 October 1997 Resolved
PORT LIFEBOAT ENGINE CRANK DETERIORATED. REPAIR/RENEW AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 6 October 1997 Resolved
VARIOUS MEDICINES HAD PAST THEIR EXPIRATION DATES, AND MISSING MEDICAL INSTRUCTIONS WERE AVAILABLE. RENEW AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 2 December 1997
Resolved 2 December 1997
Lifesaving
Issued 6 October 1997 Resolved
STARBOARD LIFEBOAT COVER STRONG BACK BROKEN. REPAIR/RENEW AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 8 November 1997
Resolved 8 October 1997
Lifesaving
Issued 6 October 1997 Resolved
STARBOARD LIFERAFT REMOVED FOR SERVICING, UNABLE TO INSPECT. INSTALL LIFERAFT AND PROVIDE SERVICING AND INSTALLATION REPORT PRIOR TO DEPARTURE. SERVICING COMPANY (DATREX) PROVIDED SERVICING REPORT SHOWING LIFERAFT IN GOOD CONDITION
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Fire Fighting
Issued 6 October 1997 Resolved
INTERNATIONAL SHORE CONNECTION WAS MISSING AND IT'S LOCATION WAS NOT NOTED ON THE SHIPBOARD FIRE FIGHTING PLAN. SHORE CONNECTION WAS LOCATED DURING THE EXAM. UPDATE FIREPLANS WITH LOCATION OF SHORE CONNECTION.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Navigation
Issued 6 October 1997 Resolved
MANEUVERING FACT SHEET WAS MISSING THE WARNING STATEMENT.
Condition: Unknown
Due 6 November 1997
Resolved 8 October 1997
Fire Fighting
Issued 6 October 1997 Resolved
STARBOARD FIRE PUMP HAD A SOFT PATCH INSTALLED, AND THE PORT FIRE PUMP WAS REMOVED. REPAIR/RENEW AND PROVIDE CLASS REPORT.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Engineering
Issued 10 November 1995 Resolved
Provide Oil Transfer Procedures in accordance with 33 CFR 155.750._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 8 January 1996
Resolved 8 January 1996

Ownership record