MAURY USCG vessel records Sign in
← All vessels

PLAYERS RIVERBOAT III

PLAYERS RIVERBOAT III is a 1994 passenger vessel (inspected). The Coast Guard has recorded 57 inspections since 1995, most recently in August 2001, along with 125 deficiencies — 2 with no resolution recorded —.

Records from 1995 to 2001. Most recent: inspection, 13 August 2001.

Built
1994
Last inspected
13 August 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCV7654
432837
Flag
UNITED STATES
—
Maury page id
psix-432837

Inspections, by type

…with no type recorded11
…past their stated due date2
Years with a record 7 calendar years (1995–2001)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it1826 - Convention (Subpart B), Net Ton
1516 - Regulatory (Subpart C or D), Net Ton
5700 - Convention (Subpart B), Gross Ton
1586 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 57

13 August 2001 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1444589
18 July 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1073076
20 June 2001 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1067505
13 March 2001 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1456953
7 February 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1059513
13 September 2000 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1450521
14 June 2000 Damage Survey · Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1365875
14 June 2000 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1386848
4 May 2000 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1476
17 March 2000 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1369601
16 March 2000 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1369600
14 December 1999 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1459562
27 October 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1404857
18 October 1999 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 188776
14 September 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1391070
14 September 1999 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1440195
8 June 1999 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1411919
10 March 1999 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 805368
8 January 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1045742
15 December 1998 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 807596
4 November 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 807182
22 September 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 798765
21 September 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 801925
18 September 1998 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1413414
19 June 1998 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1434738
19 March 1998 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1426047
12 March 1998 Deficiency Check · Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1388506
17 December 1997 Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1386164
3 October 1997 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 47862
3 October 1997 Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1111212
22 September 1997 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1434630
17 July 1997 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1451222
17 June 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 777122
23 May 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1106557
8 April 1997 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1407864
6 March 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1092686
12 February 1997 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1097028
6 January 1997 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1445148
15 November 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1093234
30 September 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1465275
16 July 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 54551
16 July 1996 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1443726
16 May 1996 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1084070
17 April 1996 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1437076
7 February 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 876730
26 January 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 22807
19 January 1996 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1416230
15 January 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2810
13 January 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 132460
13 January 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 170312
9 January 1996 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 42939
27 December 1995 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 881712
26 December 1995 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 882139
9 December 1995 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 9134
7 December 1995 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 881570
19 October 1995 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1189042
19 October 1995 Initial Certification
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1387873

Deficiency record · 125

Navigation
Issued 13 August 2001 No resolution recorded
Repair starboard radar.
Condition: Unknown
Due 13 September 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 13 August 2001 No resolution recorded
Provide annual service report for fire extinguishing equipment prior to vessel being placed in service. Vessel will be going into lay-up status prior to annual servicing is due.
Condition: Unknown
Due 13 October 2001 — due date passed with no resolution recorded
Fire Fighting
Issued 13 September 2000 Resolved
Repair or replace engineroom ventilation system Louvres, motors or relays. Vents failed to close upon activation of fire system.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Accommodation/Occupational Safety
Issued 13 September 2000 Resolved
Repair potable water system piping in forward generator room and Aux. machinery room. Piping has numerous holes with softpatches.
Condition: Unknown
Due 13 September 2000
Resolved 13 September 2000
Engineering
Issued 13 September 2000 Resolved
Replace exhaust lagging on exhaust pipe near hull on the #3 SSDG.
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Lifesaving
Issued 14 June 2000 Resolved
Provide retro-reflective material for the lifering located on the aft main deck port side.
Condition: Unknown
Due 25 July 2000
Resolved 25 July 2000
Electrical
Issued 17 March 2000 Resolved
Make proper repairs to emergency generator's fuel system and supply an alternative means of emergency power.
Condition: Unknown
Due 8 April 2000
Resolved 8 April 2000
Lifesaving
Issued 16 March 2000 Resolved
Clean oil and dirt build up and remove trash from behind the cell phone power supply rack located on the second deck forward of the galley.
Condition: Unknown
Due 8 April 2000
Resolved 8 April 2000
Construction/Loadline
Issued 16 March 2000 Resolved
Make proper repairs to both automatic WTD's to ensure proper opening and closing. One door is located in the office area at frame 41 and the other is located between the FWD and AFT generator room.
Condition: Unknown
Due 8 April 2000
Resolved 8 April 2000
Construction/Loadline
Issued 14 September 1999 Resolved
Move the two automatic bilge pumps for the port and starboard shaft_x001C_ packing containments from the main engine room bilge and locate inside the containment.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Lifesaving
Issued 14 September 1999 Resolved
Provide 224 child size life perservers.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Electrical
Issued 14 September 1999 Resolved
Label door leading to main deck electrical room with electrical room high voltage. Room is currently labeled "stowage space".
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Lifesaving
Issued 14 September 1999 Resolved
Properly secure paddles to second life float.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Lifesaving
Issued 14 September 1999 Resolved
Install machinery guard covers on the three money counting machines locatedin the hard count room. The covers were removed by the crew.
Condition: Unknown
Due 1 October 1999
Resolved 1 October 1999
Fire Fighting
Issued 14 September 1999 Resolved
Repair or renew radios used by the crew for communications during_x001C_ emergency or provide alternative means of communications for the crew. seven out of ten radios were not working properly.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Accommodation/Occupational Safety
Issued 14 September 1999 Resolved
Cap or remove opened pipe fitting for the removed sink located in the main deck men employees' head.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Engineering
Issued 14 September 1999 Resolved
Install containment around emergency generator fuel fill piping.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Fire Fighting
Issued 14 September 1999 Resolved
Repair vent clousers on the starboard side fwd and aft generator rooms.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Fire Fighting
Issued 14 September 1999 Resolved
Provide for pump handle and operation instructions for emergency WTD_x001C_ manual pumps located on main deck port side.
Condition: Unknown
Due 14 September 1999
Resolved 14 September 1999
Electrical
Issued 8 June 1999 Resolved
Properly mount temperature control switch for A/C supply fan in deckhand's storage room. Switch is hanging exposing bare wires.
Condition: Unknown
Due 6 July 1999
Resolved 6 July 1999
Engineering
Issued 8 June 1999 Resolved
Reinstall flame shields on bottom of the plastic fuel filters for #2 and #3generators. Shields were removed and never replaced.
Condition: Unknown
Due 9 July 1999
Resolved 9 July 1999
Construction/Loadline
Issued 10 March 1999 Resolved
Verify proper manual operation of aft Class III wtd.
Condition: Unknown
Due 10 March 1999
Resolved 1 April 1999
Navigation
Issued 10 March 1999 Resolved
Replace cap for unused outlet to SPP box located in aft pilothouse. (Outletis located on top of box and collecting debris, possible shorting of system).
Condition: Unknown
Due 10 March 1999
Resolved 1 April 1999
Lifesaving
Issued 15 December 1998 Resolved
Remove or provide proper storage for loose deck plates located in auxilliary machinery room.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Electrical
Issued 15 December 1998 Resolved
Repair "E" light fixture over 3rd deck stairwell.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Engineering
Issued 15 December 1998 Resolved
Double clamp radiator outlet hose to emergency generator.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Electrical
Issued 15 December 1998 Resolved
Repair wiring junction box located aft of SSG #2, portside. _x001C_ Provide enclosure box for "dead-end" wiring in pump room (discontinued auto-pump controller)
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Engineering
Issued 15 December 1998 Resolved
Repair leak in fuel inlet hose fitting to SSG #3.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Engineering
Issued 15 December 1998 Resolved
Tighten/replace packing to port/stbd MDE shafts. (Excessive leakage)
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Lifesaving
Issued 15 December 1998 Resolved
Provide approved storage rack for lifefloats.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Electrical
Issued 15 December 1998 Resolved
Provide "blank" cover inside G-1 electrical distribution panel.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Lifesaving
Issued 15 December 1998 Resolved
Properly secure the following loose gear: computers in MIS and hold space offices, slot tech parts trunk in 2nd deck electrical room, video rack in 3rd deck video room
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Lifesaving
Issued 18 September 1998 Resolved
Steering rudder room access hatch leading from smoking room missing safety sign
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Lifesaving
Issued 18 September 1998 Resolved
Bulletin boards improperly secured on fire main piping
Condition: Unknown
Due 18 October 1998
Resolved 8 October 1998
Engineering
Issued 18 September 1998 Resolved
Improper use of hose utilized for raw water alarm sensors to #1,2,3 generators, requiring hard piping
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Lifesaving
Issued 18 September 1998 Resolved
Fire damper location labling in crew's area is of similar color to background wall color making locations difficult to distinguish
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Engineering
Issued 18 September 1998 Resolved
Loose hose clamps to pre-heating line to emergency generator
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Lifesaving
Issued 18 September 1998 Resolved
Supply fan located in tool room missing protective screen
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Deck/Cargo
Issued 18 September 1998 Resolved
Bow winch wheel brake secured in "release" position
Condition: Unknown
Due 18 October 1998
Resolved 8 October 1998
Engineering
Issued 18 September 1998 Resolved
Tops to battery boxes not secured
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Electrical
Issued 18 September 1998 Resolved
Neon lighting missing safety caps
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Lifesaving
Issued 18 September 1998 Resolved
Maintenance ladders improperly stowed against 4th deck fire damper access
Condition: Unknown
Due 18 October 1998
Resolved 8 October 1998
Lifesaving
Issued 18 September 1998 Resolved
Music system receiver in platinum room, "added on" computer center equipt in way of cash cages, small refrigerator in cash office, large ATMs, excesscases of drinking cups stacked in smoking room, snack machine in crew's lounge.
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Lifesaving
Issued 18 September 1998 Resolved
Permanent use of temporary lt in Captain's office
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Construction/Loadline
Issued 18 September 1998 Resolved
New deck drain from 4th deck incomplete (old fire hose), and unsecured.
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Electrical
Issued 18 September 1998 Resolved
Distribution panel, power unit 3rd deck aft, missing index card
Condition: Unknown
Due 18 October 1998
Resolved 8 October 1998
Fire Fighting
Issued 18 September 1998 Resolved
Fire damper located in 4th deck air handler closet missing securing wingnuts
Condition: Unknown
Due 18 October 1998
Resolved 8 October 1998
Electrical
Issued 18 September 1998 Resolved
Electrical in 3rd deck women's bathroom missing cover
Condition: Unknown
Due 18 October 1998
Resolved 8 October 1998
Fire Fighting
Issued 18 September 1998 Resolved
Magnetic releases to fire screen door #5 not working
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Accommodation/Occupational Safety
Issued 18 September 1998 Resolved
Unsecured slot tournament table on 3rd deck, unsecured snack table in pokerroom, unsecured standing fan in poker room and requires permanent wiring application, unsecured cash carts on 3rd deck, excessive furniture in platinum room, unsecured garbage cans outside galley
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Lifesaving
Issued 18 September 1998 Resolved
Aft lifering located on 3rd deck past service life
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Electrical
Issued 18 September 1998 Resolved
Improper protective practices (tape) utilized on wire connections in air handler closets
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Construction/Loadline
Issued 18 September 1998 Resolved
Hinge pins to generator room watertight doors worn/distorted requiring replacement
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Electrical
Issued 18 September 1998 Resolved
Overhead light located in tool room not fitted with protective cover
Condition: Unknown
Due 18 September 1998
Resolved 18 September 1998
Accommodation/Occupational Safety
Issued 18 September 1998 Resolved
Emergency public address system intermittent on 3rd deck of power unit_x001C_ Emergency public address system audible level weak on 2nd deck
Condition: Unknown
Due 21 September 1998
Resolved 8 October 1998
Electrical
Issued 17 December 1997 Resolved
Remove extension cords & power strips from bar service areas and change cages_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 15 January 1998
Accommodation/Occupational Safety
Issued 17 December 1997 Resolved
Secure liquor lines on main deck bar. (hanging)
Condition: Unknown
Due 18 January 1998
Resolved 15 January 1998
Accommodation/Occupational Safety
Issued 17 December 1997 Resolved
Clean bar service areas (all)_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 21 January 1998
Lifesaving
Issued 17 December 1997 Resolved
Repair door on port lifejacket locker (difficult to open) 02 deck fwd._x001C_
Condition: Unknown
Due 18 January 1998
Resolved 15 January 1998
Fire Fighting
Issued 17 December 1997 Resolved
Repair insulation in liquor storage area Main deck forward. (4 square ft damaged)_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 15 January 1998
Accommodation/Occupational Safety
Issued 17 December 1997 Resolved
Repair drain line under bar on second deck aft (leaks)
Condition: Unknown
Due 18 January 1998
Resolved 15 January 1998
Electrical
Issued 17 December 1997 Resolved
Instal globe on light fixture in flanking rudder room (missing)_x001C_
Condition: Unknown
Due 18 January 1998
Resolved 15 January 1998
Construction/Loadline
Issued 3 October 1997 Resolved
PROVIDE PROPOSAL FOR PERMANENT REPAIR TO WASTED HULL PLATE IN WAY OF PORT MAIN ENGINE EXHAUST PIPING.
Condition: Unknown
Due 3 October 1997
Resolved 3 October 1997
Accommodation/Occupational Safety
Issued 22 September 1997 Resolved
Provide cover for thermostat to auxilliary machinery space heater.
Condition: Unknown
Due 22 October 1997
Resolved 20 November 1997
Electrical
Issued 22 September 1997 Resolved
Prominently mark deep fat fryer breakers and prominently service box containing breakers.
Condition: Unknown
Due 22 October 1997
Resolved 20 November 1997
Accommodation/Occupational Safety
Issued 22 September 1997 Resolved
Make repairs to backflow preventer valve in way of A/C chiller piping.
Condition: Unknown
Due 22 October 1997
Resolved 20 November 1997
Electrical
Issued 22 September 1997 Resolved
Repair/renew wiring to 110V outlet, 01 deck, portside fwd of breakroom.
Condition: Unknown
Due 22 October 1997
Resolved 20 November 1997
Construction/Loadline
Issued 22 September 1997 Resolved
Provide permanent installation for main engine room sump pump (service)._x001C_
Condition: Unknown
Due 22 October 1997
Resolved 20 November 1997
Accommodation/Occupational Safety
Issued 22 September 1997 Resolved
Provide proper storage of crew room beverage stand.
Condition: Unknown
Due 22 October 1997
Resolved 20 November 1997
Engineering
Issued 22 September 1997 Resolved
Provide technician report on all engineering trips and alarms.
Condition: Unknown
Due 22 October 1997
Resolved 20 November 1997
Construction/Loadline
Issued 22 September 1997 Resolved
Renew/replace operating instructions to WTD remote operation site.
Condition: Unknown
Due 22 October 1997
Resolved 20 November 1997
Lifesaving
Issued 22 September 1997 Resolved
Mount concession machines in crew break room.
Condition: Unknown
Due 22 October 1997
Resolved 20 November 1997
Lifesaving
Issued 22 September 1997 Resolved
Repair/replace bow lift eyelet to port rescue boat.
Condition: Unknown
Due 22 October 1997
Resolved 20 November 1997
Accommodation/Occupational Safety
Issued 17 July 1997 Resolved
SECURE CASH ADVANCE MACHINE SECOND DECK IWO STAIRWAY, BOLT DOWN ACCESS PANEL TO 4TH DECK AHU CABINET, SECURE GALLEY GRILL TO BULKHEAD, SECURE BREAD RACK, ALTOSHAM, AND GREASE TUB TO DECK/BULKHEAD.
Condition: Unknown
Due 17 August 1997
Resolved 28 August 1997
Engineering
Issued 17 July 1997 Resolved
DRAIN & RENEW FUEL IN F.O. TANK FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 17 August 1997
Resolved 28 August 1997
Accommodation/Occupational Safety
Issued 17 July 1997 Resolved
REMOVE HOUSEKEEPING LOCKER FROM SECOND DECK STAIRWAY
Condition: Unknown
Due 17 August 1997
Resolved 28 August 1997
Construction/Loadline
Issued 17 July 1997 Resolved
PROVIDE WRENCH FOR RUDDER ROOM WT HATCH.
Condition: Unknown
Due 17 August 1997
Resolved 28 August 1997
Fire Fighting
Issued 17 July 1997 Resolved
PROVIDE LOW VELOCITY APPLICATOR FOR ENGINEERING SPACES
Condition: Unknown
Due 17 July 1997
Resolved 17 July 1997
Lifesaving
Issued 17 July 1997 Resolved
REPAIR ALARM BELL FOR ENGINE ROOM WTD.
Condition: Unknown
Due 17 August 1997
Resolved 28 August 1997
Accommodation/Occupational Safety
Issued 17 July 1997 Resolved
REMOVE EXCESS FLAMMABLES FROM CAPTIANS OFFICE
Condition: Unknown
Due 17 August 1997
Resolved 28 August 1997
Accommodation/Occupational Safety
Issued 17 July 1997 Resolved
CLEAN UNDER GALLEY GRILL
Condition: Unknown
Due 17 August 1997
Resolved 28 August 1997
Electrical
Issued 17 July 1997 Resolved
PROVIDE CIRCUIT INDEX FOR SERVICE PANEL E-20
Condition: Unknown
Due 17 July 1997
Resolved 28 August 1997
Accommodation/Occupational Safety
Issued 17 July 1997 Resolved
CLEAN GRATING AND DUCTING TO OUTSIDE DISCHARGE TO GALLEY VENTING
Condition: Unknown
Due 17 August 1997
Resolved 28 August 1997
Navigation
Issued 17 July 1997 Resolved
RENEW TIDE AND CURRENT TABLES
Condition: Unknown
Due 17 August 1997
Resolved 28 August 1997
Engineering
Issued 8 April 1997 Resolved
Provide pollution prevention placard for each fueling station.
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Lifesaving
Issued 8 April 1997 Resolved
Clean/lube working parts to freezer emergency escape system.
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Navigation
Issued 8 April 1997 Resolved
Calibrate all flanking/steering rudder angle indicators
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Fire Fighting
Issued 8 April 1997 Resolved
Replace/renew shaft seal to fire pump.
Condition: Unknown
Due 10 April 1997
Resolved 14 April 1997
Lifesaving
Issued 8 April 1997 Resolved
Replace standard outlets to all bathroom automatic faucets, 1st deck bar under well, and 3rd deck fwd bar under sink with GFI outlets.
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Accommodation/Occupational Safety
Issued 8 April 1997 Resolved
Clean out all AHU spaces. Remount all unsecured electronics. Secure weathertight box in AHU #14.
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Fire Fighting
Issued 8 April 1997 Resolved
Provide mounting device for CO2 extinguisher located in texas deck air receiver room.
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Lifesaving
Issued 8 April 1997 Resolved
Conduct a safety survey regarding cleaning, lubricating, and maintenence products. Create master file of MSDS. Properly lable all product usage bottles. Provide proper stowage of such products. Create hazardous communication plan for vessel.
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Lifesaving
Issued 8 April 1997 Resolved
Properly secure center rack of employee lockers
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Lifesaving
Issued 8 April 1997 Resolved
Hardcount Room - Repair electrical cord plug to UPS, provide faceplates to phone jacks.
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Lifesaving
Issued 8 April 1997 Resolved
Replace liferings located at pilothouse and 2nd deck fwd.
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Fire Fighting
Issued 6 January 1997 Resolved
Provide guard for engineroom fixed CO2 system tanks in crew locker room.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Electrical
Issued 6 January 1997 Resolved
Investigate electrical outlets "taped over" in bar service areas and repairas necessary.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Lifesaving
Issued 6 January 1997 Resolved
Secure the following: 2nd deck central bar storage rack, 1st deck fwd cigarette machine, valve actuators in pump room, all CO2 tank "hardracks", and storage racks in food/beverage office.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Lifesaving
Issued 6 January 1997 Resolved
Secure housekeeping supply locker, 3rd deck, portside
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Electrical
Issued 6 January 1997 Resolved
Repair broken electrical junction box cover in 2nd deck central bar storage.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Unknown
Issued 6 January 1997 Resolved
Provide updated fireload calculation for improvements to Platinum Room. (Casino Royale room) (New carpet, couches, chairs, tables)
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Lifesaving
Issued 6 January 1997 Resolved
Remove electrical extension cord to elevator cooling fan located in pump room. Provide permanent outlet.
Condition: Unknown
Due 6 January 1997
Resolved 6 January 1997
Electrical
Issued 30 September 1996 Resolved
Clear grounds on Main and Aux switchboards
Condition: Unknown
Due 7 October 1996
Resolved 22 October 1996
Fire Fighting
Issued 30 September 1996 Resolved
Conduct flow check of sprinkler system.
Condition: Unknown
Due 30 October 1996
Resolved 22 October 1996
Lifesaving
Issued 30 September 1996 Resolved
Install fan guard on exhaust on galley vent.
Condition: Unknown
Due 30 October 1996
Resolved 22 October 1996
Lifesaving
Issued 30 September 1996 Resolved
Secure cabinets and stowage lockers located in galley
Condition: Unknown
Due 30 October 1996
Resolved 22 October 1996
Electrical
Issued 30 September 1996 Resolved
Install faceplate on electrical junction box on AHR # 8._x001C_
Condition: Unknown
Due 30 October 1996
Resolved 22 October 1996
Fire Fighting
Issued 30 September 1996 Resolved
Re install insulation in way of acess door bow thruster room.
Condition: Unknown
Due 8 October 1996
Resolved 22 October 1996
Construction/Loadline
Issued 30 September 1996 Resolved
Make stuffing tubes (2ea) water tight in sewage pumproom
Condition: Unknown
Due 30 October 1996
Resolved 22 October 1996
Navigation
Issued 30 September 1996 Resolved
Repair sound powered phone located on paddle wheel deck
Condition: Unknown
Due 30 September 1996
Resolved 30 September 1996
Accommodation/Occupational Safety
Issued 30 September 1996 Resolved
Permanently install vent extentions attached to sewage vents on Texas deck._x001C_ _x001C_
Condition: Unknown
Due 30 October 1996
Resolved 22 October 1996
Electrical
Issued 30 September 1996 Resolved
Permanently install lighting fixture in overhead of Texas Deck UPS room.
Condition: Unknown
Due 30 October 1996
Resolved 22 October 1996
Navigation
Issued 30 September 1996 Resolved
Calibrate rudder angle indicator on tug pilot house
Condition: Unknown
Due 30 October 1996
Resolved 22 October 1996
Electrical
Issued 30 September 1996 Resolved
Mark emergency lights with an "E"
Condition: Unknown
Due 30 October 1996
Resolved 22 October 1996
Engineering
Issued 30 September 1996 Resolved
Test relief valves on all pressure vessels.
Condition: Unknown
Due 30 October 1996
Resolved 22 October 1996
Accommodation/Occupational Safety
Issued 16 July 1996 Resolved
REPLACE MISSING REGISTERS ON VENTILATION OUTLETS IN MARDI GRAS GALLEY
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Accommodation/Occupational Safety
Issued 16 July 1996 Resolved
ADRESS OVERHEATING OF ELEVATOR HYDRAULIC OIL
Condition: Unknown
Due 16 July 1996
Resolved 16 July 1996
Fire Fighting
Issued 19 January 1996 Resolved
Repair inoperative general alarm bell 3rd deck midships.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Engineering
Issued 19 January 1996 Resolved
Repair exhaust leak on #2 S/S generator.
Condition: Unknown
Due 19 January 1996
Resolved 19 January 1996
Electrical
Issued 7 December 1995 Resolved
VESSEL TO REMAIN DOCKSIDE UNTIL BREAKER PROBLEM CORRECTED. VSL TO SUBMITT PROBLEM ANALYSIS INVOLVING PROBLEM.
Condition: Unknown
Due 8 December 1995
Resolved 14 December 1995
Electrical
Issued 7 December 1995 Resolved
ENSURE PROPER OPERATION OF REVERSE POWER RELAYS PRIOR TO OPERATING GENERATORS IN PARALLEL. SUBMIT CHANGES TO ELECTRICAL PRINTS UPON CORRECTIONOF PROBLEM.
Condition: Unknown
Due 7 December 1995
Resolved 7 December 1995
Deck/Cargo
Issued 19 October 1995 Resolved
PROVIDE DATA ON ANCHOR AS TO HOLDING EFFICIENCY FOR SIZE OF VESSEL EMPLOYED.
Condition: Unknown
Due 20 November 1995
Resolved 28 November 1995
Fire Fighting
Issued 19 October 1995 Resolved
INSTALL FIXED CO2 FIRE SUPPRESSION SYSTEM IN THIRD DECK ELECTRICAL ROOM.
Condition: Unknown
Due 15 December 1995
Resolved 8 December 1995
Electrical
Issued 19 October 1995 Resolved
PROVIDE UPDATED ELECTRICAL PLANS TO INCLUDE "AS BUILTS".
Condition: Unknown
Due 19 October 1995
Resolved 19 October 1995
Electrical
Issued 19 October 1995 Resolved
PROVIDE ASSURANCE OF OPERATION OF #3 SHIP'S SERVICE GENERATOR REPLACEMENT.
Condition: Unknown
Due 15 December 1995
Resolved 8 December 1995

Ownership record