Records from 1985 to 2012. Most recent: inspection, 18 January 2012.
Documentation record
Registered dimensions (L × B × D)36.9 ft × 10.3 ft × 4.5 ft
Registered tonnagegross 11 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHRIS-CRAFT CORPORATION · ALGONAC, MI, UNITED STATES · built 1943
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBODEGA BAY, CA
Trade endorsementsFishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itCommercial Fishing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it7 - Regulatory (Subpart C or D), Net Ton
11 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
18 January 2012
Type not recorded
No type recorded · Station Bodega Bay · USCG Southwest District (CGD-SW) · Activity 4227849
17 November 2003
Type not recorded
No type recorded · Station Bodega Bay · USCG Southwest District (CGD-SW) · Activity 1949278
17 November 2003
Type not recorded
No type recorded · Station Bodega Bay · USCG Southwest District (CGD-SW) · Activity 1950508
17 November 2003
Type not recorded
No type recorded · Station Bodega Bay · USCG Southwest District (CGD-SW) · Activity 1953797
17 November 2003
Type not recorded
No type recorded · Station Bodega Bay · USCG Southwest District (CGD-SW) · Activity 2170133
17 February 1999
Type not recorded
No type recorded · Station Vallejo · USCG Southwest District (CGD-SW) · Activity 1511960
4 August 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 842808
4 July 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 36728
15 November 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 940345
31 January 1991
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 931426
13 February 1989
Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1035664
30 January 1989
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1209230
17 February 1988
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1021981
26 January 1988
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1016515
1 April 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1328767
6 February 1987
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1319533
28 February 1986
Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1300995
20 February 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1283207
13 February 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 976170
Documentation
Issued 13 February 1989
Resolved
NEED TO PROVIDE VESSEL DOCUMENT AND KEEP IT ON THE VESSEL AT ALL TIMES.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Engineering
Issued 13 February 1989
Resolved
MOUSE DOWN EMERGENCY FUEL SHUT DOWN RODS TO PREVENT VIBRATING LOOSE, SWITCHSTARBOARD FORWARD REACH ROD TO FUEL TANK VALVE INSTEAD OF THE FUEL CROSS- OVER VALVE.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Lifesaving
Issued 13 February 1989
Resolved
REWORK WEAK LINK ON BUOYANT APPARATUS SO THAT LINE COMES FREE OF HOLDER WITHOUT SNAGGING AND REATTACH TO THE BUOYANT APPARATUS.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Documentation
Issued 13 February 1989
Resolved
POST POLLUTION PREVENTION REQUIREMENTS ON THE VESSEL.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Navigation
Issued 13 February 1989
Resolved
PROVIDE VHF RADIO FOR VESSEL.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Navigation
Issued 13 February 1989
Resolved
REPAIR OR HOOK UP FATHOMETER.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Construction/Loadline
Issued 13 February 1989
Resolved
REPAIR PORT BILGE PUMP IN AFTERSTEERING SPACE AND DEMONSTRATE OPERATION.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Construction/Loadline
Issued 13 February 1989
Resolved
HATCHES TO ENGINEROOM AND AFTERSTEERING NEED TO BE WORKED ON SO THAT THEY MAY BE SECURED AND WON'T FLOAT FREE OR BREAK LOOSE IN HEAVY SEAS.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Engineering
Issued 13 February 1989
Resolved
STENCIL OR LABEL EMERGENCY FUEL SHUT DOWN REMOTE OPERATORS AS TO LOCATION.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Navigation
Issued 13 February 1989
Resolved
PROVIDE DEVIATION TABLE FOR VESSELS COMPASS.
Condition: Unknown
Due 13 February 1989
Resolved 13 February 1989
Engineering
Issued 30 January 1989
Resolved
INSTALL FUEL SHUTOFF VALVE REACH RODS AT EACH FUEL TANK CONNECTION SO AS TO BE OPERABLE FROM OUTSIDE THE SPACE.
Condition: Unknown
Due 30 January 1989
Resolved 30 January 1989
Electrical
Issued 1 April 1987
Resolved
3. REPAIR OR REPLACE LIGHT GLOBES IN ENGINROOM.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Lifesaving
Issued 1 April 1987
Resolved
4. STENCIL VESSEL NAME ON NEW PFD'S.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Construction/Loadline
Issued 1 April 1987
Resolved
2. DOUBLE CLAMP WASH DOWN HOSE AT THE THROUGH HULL FITTING IN LAZARETTE (PORT SIDE).
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Lifesaving
Issued 1 April 1987
Resolved
1. RESTENCIL BOUYANT APPARATUS.
Condition: Unknown
Due 1 April 1987
Resolved 1 April 1987
Accommodation/Occupational Safety
Issued 28 February 1986
Resolved
CHAIN AND LOCK SANITARY SYSTEM OVERBOARD DISCHARGE VALVE IN CLOSED POSITION
Condition: Unknown
Due 28 February 1986
Resolved 28 February 1986
Lifesaving
Issued 20 February 1985
Resolved
REPLACE ONE ADULT LIFEJACKET.
Condition: Unknown
Due 20 February 1985
Resolved 20 February 1985