Records from 1985 to 1991. Most recent: inspection, 1 February 1991.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
1 February 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 932623
28 April 1989
Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 887218
3 June 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1197288
14 April 1988
Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1339852
17 February 1988
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1329892
12 June 1987
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1029375
23 April 1987
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1018477
2 April 1987
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1023631
3 March 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1320565
28 February 1986
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 989486
11 February 1986
Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 987383
5 March 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 979316
5 February 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 974058
Lifesaving
Issued 28 April 1989
Resolved
PROVIDE NEW FLARES: 6 RED AND 6 ORANGE (SMOKES), OR 12 COMBINATION FLARES.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Construction/Loadline
Issued 28 April 1989
Resolved
ATTACH KEEPER CHAIN TO LAZARETTE HATCH.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Fire Fighting
Issued 28 April 1989
Resolved
REMOVE UNAPPROVED B1 FIRE EXTINGUISHER FROM PILOTHOUSE.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Fire Fighting
Issued 28 April 1989
Resolved
HAVE ALL FIRE EXTINGUISHERS SERVICED.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Lifesaving
Issued 28 April 1989
Resolved
REPLACE PENDANTS ON STBD LIFE RING.
Condition: Unknown
Due 28 April 1989
Resolved 28 April 1989
Construction/Loadline
Issued 14 April 1988
Resolved
REMOVE ENGINEROOM FURRING FROM UNDERDECK BEAMS TO GOOD WOOD AND TREAT.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Construction/Loadline
Issued 14 April 1988
Resolved
RECAULK AROUND ENTIRE DECK AND RAIL/BULWARK TO STOP LEAKAGE OF WATER FROM DECK TO INTERNAL COMPARTMENTS.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Engineering
Issued 17 February 1988
Resolved
4 STENCIL/TAG BILGE SYSTEM VALVES.
Condition: Unknown
Due 17 February 1988
Resolved 17 February 1988
Construction/Loadline
Issued 17 February 1988
Resolved
9 PROVIDE VALVES ON INLET AND OUTLET OF KEEL COOLER AS CLOSE TO THE THROUGH HULL FITTING AS PRACTICLE.
Condition: Unknown
Due 17 February 1988
Resolved 17 February 1988
Accommodation/Occupational Safety
Issued 17 February 1988
Resolved
7 CHAIN AND LOCK OR POST SIGN NOT TO OPEN MSD DISCHARGE VALVE.
Condition: Unknown
Due 17 February 1988
Resolved 17 February 1988
Electrical
Issued 3 March 1987
Resolved
REPAIR BILGE ALARM LOCATED IN MID-BODY COMPARTMENT.
Condition: Unknown
Due 3 March 1987
Resolved 3 March 1987
Construction/Loadline
Issued 3 March 1987
Resolved
REMOVE FURRING IN ENGINE ROOM, USING SOUND MARINE PRACTICE.
Condition: Unknown
Due 3 March 1987
Resolved 3 March 1987
Engineering
Issued 3 March 1987
Resolved
PROVIDE FLAME PROTECTION FOR EMERGENCY FUEL SHUT-OFF.
Condition: Unknown
Due 3 March 1987
Resolved 3 March 1987
Engineering
Issued 3 March 1987
Resolved
PROVIDE FLAME SCREEN ON PORT FUEL TANK VENT.
Condition: Unknown
Due 3 March 1987
Resolved 3 March 1987
Engineering
Issued 11 February 1986
Resolved
INSTALL ENGINEROOM VENTILATION DUCT CONSTRUCTED OF FIRE PROOF MATERIAL THATEXTENDS TO A POINT NEAR THE BOTTOM OF THE COMPARTMENT.
Condition: Unknown
Due 11 February 1986
Resolved 11 February 1986
Unknown
Issued 11 February 1986
Resolved
CHAIN AND LOCK SANITARY HOLDING TANK OVERBOARD DISCHARGE VALVE IN CLOSED POSITION.
Condition: Unknown
Due 11 February 1986
Resolved 11 February 1986
Lifesaving
Issued 5 February 1985
Resolved
PROVIDE 1 ADULT AND 1 CHILD PFD.
Condition: Unknown
Due 5 February 1985
Resolved 5 February 1985
Unknown
Issued 5 February 1985
Resolved
REPLACE WINDOW IN CABIN STARBOARD SIDE AFT.
Condition: Unknown
Due 5 February 1985
Resolved 5 February 1985
Documentation
Issued 5 February 1985
Resolved
CONDUCT STABILITY TEST OR OBTAIN AN EXEMPTION.
Condition: Unknown
Due 5 February 1985
Resolved 5 February 1985