This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)150.0 ft × 32.1 ft × 9.5 ft
Registered tonnagegross 346 / net 346
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBEAUMONT, TX, UNITED STATES · built 1957
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNot recorded
Endorsements, as the file codes themcw_un
DocumentationInvalid
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it346 - Regulatory (Subpart C or D), Gross Ton 346 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 36 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 36
12 February 2008Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3146359
9 August 2006COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2741150
5 December 2005Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2547196
18 November 2005Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2535757
22 December 2003Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1973519
3 November 2003Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1955616
15 July 2002Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1644756
25 April 2002Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1608928
10 August 2001COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1399696
11 August 2000Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440368
30 November 1999Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 810878
11 August 1999COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451434
11 September 1998Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431999
14 August 1997Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449061
14 August 1997COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464057
20 June 1995Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 878906
23 January 1995Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1181454
13 June 1994Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398025
12 January 1993COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444695
18 February 1992Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944175
14 January 1991Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1235151
11 December 1989Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1216232
19 December 1988Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 898448
7 November 1988Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1206903
26 October 1988Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1199425
11 February 1988Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1327253
28 October 1987Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1318894
28 October 1987COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1326412
6 January 1987Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309746
18 November 1986Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1330905
27 November 1985COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992577
7 November 1984Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1283251
18 November 1983Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971048
5 May 1983Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969194
11 May 1982Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272194
5 May 1981Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964544
Port side navigation light stand was missing. LEGACY COMPONENT DESC: Navigation Lights
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 November 2003
Resolution: Renewed port side navigation light stand.
Construction/Loadline › Markings
Issued 3 November 2003Resolved
Draft marks were unreadable. LEGACY COMPONENT DESC: Draft Marks/Indicating System
Due 3 December 2003
Resolved 4 November 2003
Resolution: Repainted draft marks.
Engineering › Fuel Oil Service System
Issued 3 November 2003Resolved
Two fuel lines were dry rotting and cracked. LEGACY COMPONENT DESC: Hose
Due 3 December 2003
Resolved 4 November 2003
Resolution: Renewed fuel lines with approprate hoses.
Engineering › Fuel Oil Service System
Issued 3 November 2003Resolved
Several hosed were showing signs of chaffing. LEGACY COMPONENT DESC: Hose
Due 3 December 2003
Resolved 4 November 2003
Resolution: Adequate chaffing gear provided.
Engineering › Diesel Engine (auxiliary)
Issued 3 November 2003Resolved
The installed emergency shutdown device did not work. LEGACY COMPONENT DESC: Emergency Shutdown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 November 2003
Resolution: Demostrated proper emergency shutdown ability.
Unknown
Issued 11 August 2000Resolved
PRIOR TO OPERATING VESSEL STENCIL VESSEL'S NAME AND HAILING PORT ON STERN.
Condition: Unknown
Due 18 August 2000
Resolved 21 August 2000
Documentation
Issued 11 August 2000Resolved
PROVIDE TO LOADING CARGO PROVIDE CARGO TRANSFER PROCEDURES.
Condition: Unknown
Due 18 August 2000
Resolved 21 August 2000
Deck/Cargo
Issued 11 August 2000Resolved
RENEW FLAME SCREEN AND 1 MISSING DOG ON #3 STARBOARD CARGO TANK ULLAGE.
Condition: Unknown
Due 18 August 2000
Resolved 21 August 2000
Unknown
Issued 11 August 2000Resolved
PERMANENTLY REMOVE LOADLINE MARKINGS OR PROVIDE CURRENT CLASSIFICATION SOCIETY LOADLINE CERTIFICATE.
Condition: Unknown
Due 18 August 2000
Resolved 21 August 2000
Documentation
Issued 11 August 2000Resolved
PROVIDE CARGO PIPING DIAGRAM SHOWING CARGO MANIFOLD CONTAINMENT DRAIN TO CARGO TANKS.
Condition: Unknown
Due 14 August 2000
Resolved 14 August 2000
Deck/Cargo
Issued 11 August 2000Resolved
RE-STENCIL EMERGENCY STOP SIGN.
Condition: Unknown
Due 18 August 2000
Resolved 21 August 2000
Deck/Cargo
Issued 11 August 2000Resolved
REPLACE PUMP PRIME MOVER FUEL TANK FLAME SCREEN.
Condition: Unknown
Due 18 August 2000
Resolved 21 August 2000
Documentation
Issued 13 June 1994Resolved
BARGE IS TO BE MAINTAINED IN A GAS FREE CONDITION (I.E. CARRY NO SUBCHAPTER"D" CARGOES) UNTIL A U.S. COAST GUARD APPROVED VESSEL RESPONSE PLAN IS PLACED ABOARD THE VESSEL.
Condition: Unknown
Due 13 June 1994
Resolved 13 June 1994
Deck/Cargo
Issued 28 October 1987Resolved
PROIR TO LOADING CARGO HYDRO TEST PIPING TO A MINIMUM OF 1-1/2 TIMES THE MAWP AND PROVIDE AFFADAVIT OF SAME.
Condition: Unknown
Due 28 October 1987
Resolved 28 October 1987
Deck/Cargo
Issued 6 January 1987Resolved
UPON COMPLETING INSTALLATION OF CARGO PUMP, CONDUCT OPERATIONAL TEST OF PUMP AND EMERGENCY STOP.
Condition: Unknown
Due 6 January 1987
Resolved 6 January 1987
Deck/Cargo
Issued 18 November 1986Resolved
UPON COMPLETING INSTALLATION OF CARGO PUMP, CONDUCT OPERATIONAL TEST OF PUMP AND EMERGENCY STOP.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.