MAURY USCG vessel records
← All vessels

JUSTICE

JUSTICE is a 1995 freight ship. The Coast Guard has recorded 9 inspections since 2016, most recently in April 2017, along with 7 deficiencies and 4 operational controls.

Records from 2016 to 2017. Most recent: operational control imposed, 29 April 2017.

Built
1995
Last inspected
29 April 2017
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 April 2017
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 2 calendar years (2016–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9116321
433074
Flag
LIBERIA
Maury page id
psix-433074

Documentation record

Tonnage as PSIX records it27900 - Dead Weight, Ton
34901 - Displacement, Ton
18108 - Convention (Subpart B), Gross Ton
10015 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
Detail on this page

9 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; 4 operational controls with the dates imposed and removed; the documentation record, as PSIX holds it. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 9

29 April 2017 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6134973
29 April 2017 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6135099
20 April 2017 Deficiency Check · COE-Administrative
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6129006
26 December 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6062513
19 December 2016 COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6059839
27 November 2016 Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6047943
25 November 2016 PII Safety Exam · Ballast Water Examination · Deficiency Check · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 6044250
14 September 2016 ISPS II Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6000380
14 September 2016 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6000897

Deficiency record · 7

Navigation › Collision/Grounding Avoidance › Radar
Issued 29 April 2017 Resolved
10cm Radar would not turn on
Action required: 17 - Rectify deficiencies prior to departure
Due 9 May 2017
Resolved 2 May 2017
Resolution: Received technician report attesting to the satisfactory working condition of the ships radar.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 25 November 2016 Resolved
Emergency Generator's fuel tank does not have a means of closing the valve from outside the space. 74SOLAS(97) CH II-2 REG 15.2.5 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2016
Resolved 27 November 2016
Resolution: Vessel crew memebers installed a stop valve for the emergency generator's fuel tank which is capable of being closed from a safe position outside the emergency generator room.
Communications › Alarms/Indicators › General Alarm
Issued 25 November 2016 Resolved
The vessel's engine control room does not have any visual indicating alarms. 74SOLAS(97) CHII-1/51.1.1 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2016
Resolved 27 November 2016
Resolution: Vessels crew members installed visual alarm in the engine room near main engine local control position.
Construction/Loadline › Structures › Door
Issued 25 November 2016 Resolved
The vessel has several self-closing dorrs throught the accomodation spaces with permanent hold backs. 74SOLAS(97) CH II-2// 47.2 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2016
Resolved 27 November 2016
Resolution: Vessels crew memeber removed hold back hooks for self-closing doors throughout accomodation spaces.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 25 November 2016 Resolved
Vessel has no documentation and certificates or visual verification to determine the expiration or test dates for the liferaft hydrostatic release units, specifically starboard side. 74SOLAS(97) III/ 19.9.1 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2016
Resolved 27 November 2016
Resolution: Port and Starboard life-rafts hydrostatic release units has been replaced by new units
Pollution Prevention/Response › Response Equipment › Containers
Issued 25 November 2016 Resolved
Vessel has multiple drums of chemicals for cleaning not labeled out on the cargo deck. 49CFR172.400 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2016
Resolved 27 November 2016
Resolution: All drums of chemicals for cleaning where labeled with their respective class labels.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 25 November 2016 Resolved
Vessel could not provide proof of their annual hydrostatic testing of their bunker lines 33CFR156.170(f)(3)
Condition: Improper/Lack of Maintenance
Action required: 703 - Prior to bunkering operations
Due 25 November 2016
Resolved 20 April 2017
Resolution: Testing report recieved by Sector New York

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.