MAURY USCG vessel records Sign in
← All vessels

BLUE MARLIN

BLUE MARLIN is a 1996 offshore supply vessel. The Coast Guard has recorded 29 inspections since 1996, most recently in September 2015, along with 41 deficiencies — 2 with no resolution recorded —.

Records from 1996 to 2015. Most recent: inspection, 16 September 2015.

Built
1996
Last inspected
16 September 2015
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8968636 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
433357
Flag
NIGERIA
367042940 (licence lapsed)
Maury page id
psix-433357

Inspections, by type

…with no type recorded3
Years with a record 18 calendar years (1996–2015)
The 29 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 11 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it113 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
377 - Convention (Subpart B), Gross Ton
98 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD4868MMSI 367042940 · expired · compulsorily equipped · granted 13 November 2006, cancelled 14 January 2017 · licensed under a name not among this hull’s recorded names (not shown)
WCW4641MMSI 367042940 · expired · compulsorily equipped · granted 24 April 1996, cancelled 24 June 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 29

16 September 2015 COE-Dockside · ISPS II Exam · NPV Safety Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5717941
16 October 2014 Administrative Inspection
Administrative · Activities Europe · Activity 5006052
28 June 2012 Administrative Inspection
Administrative · Activities Europe · Activity 4359260
19 February 2012 MTSA/ISPS Verification · COI Inspection · DAPI Audit
Physical examination · Activities Europe · Activity 4202494
20 January 2012 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4228444
11 January 2011 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · Activities Europe · Activity 3901761
11 January 2009 Hull Examination · Annual Inspection
Physical examination · Activities Europe · Activity 3385776
28 July 2008 Administrative Inspection
Administrative · Activities Europe · Activity 3281946
2 June 2008 Annual Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 3224686
19 March 2007 MTSA/ISPS Verification · COI Inspection
Physical examination · Activities Europe · Activity 2878268
8 January 2007 Hull Examination
Physical examination · Activities Europe · Activity 2832703
27 April 2006 Internal Structural Exam · Annual Inspection
Physical examination · Activities Europe · Activity 2556386
27 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2502055
23 August 2005 MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2472491
19 April 2005 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2337807
1 April 2004 Internal Structural Exam · Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2036032
2 May 2003 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1782231
4 April 2002 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1600829
16 May 2001 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387068
14 June 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1381918
13 April 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817239
7 February 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1391209
4 May 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365198
23 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 769678
1 February 1999 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 208453
11 May 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453483
25 April 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443855
12 March 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1092456
2 May 1996 Initial Construction-Excluding Oversight · Inclining Experiment · Hull Examination · Initial Certification
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1357634

Deficiency record · 41

Personnel › Certificates/Documents/Licenses › STCW Endorsement
Issued 16 September 2015 No resolution recorded
0220 - Crew - Documentary proof shall be available that application for a Flag Endorsement has been submitted to the Administration. Crew could not provide Flag Endorsement or proof of application. - STCW 2010 Reg I/10 5
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Communications › Alarms/Indicators › Bilge Alarm
Issued 16 September 2015 No resolution recorded
1500 - Navigation - Cargo ships of 150 gross tonnage and upwards but less than 500 gross tonnage constructed before 1 July 2011 shall be fitted with a bridge navigational watch alarm system. Vessel is not fitted with a bridge navigational watch alarm system. - SOLAS 2014 Consolidated Chapter V Reg 19 2.2.3.3.5
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Documentation › Certificates/Documents › Certificate of Inspection
Issued 19 February 2012 Resolved
COI operator does not match ISM / ISPS company. Review documents and apply for changes as appropriate.
Action required: 705 - Other - as specified
Due 19 March 2012
Resolved 30 October 2012
Resolution: CSR was amended to correct addresses, etc.
Construction/Loadline › Hull › Weld
Issued 19 February 2012 Resolved
Multiple deck support stanchins in engine room were found to be fractured at overhead weld. The following posts were found to be fractured: the two fwd posts between stbd. and center main engines; the two middle posts between stbd. and center main engines; one aft post between stbd. and center main engines; one aft post between port and center engines; one middle post between port and center eng.
Action required: 705 - Other - as specified
Due 4 March 2012
Resolved 5 March 2012
Electrical › Electrical Distribution System (service) › Cable
Issued 19 February 2012 Resolved
Multiple electrical cables in the engine room and thruster room are supported by plastic zip ties. Ensure cable runs are supported every two feet with metallic straps as per 46 CFR 183.340(b)(4).
Action required: 705 - Other - as specified
Due 19 March 2012
Resolved 14 March 2012
Resolution: Rcvd email from vsl Master [name withheld] lic # 55409 that all plastic zip ties have been replaced with metallic straps.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 11 January 2011 Resolved
Provide copy of corrected Safety Radio Certificate. Current certificate was issued with incorrect IMO Number, wrong keel laid date and wrong form R date.
Due 13 March 2011
Resolved 16 March 2011
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 11 January 2011 Resolved
Provide up-to-date navigation publications. Master to send verification via email.
Action required: 705 - Other - as specified
Due 13 March 2011
Resolved 13 March 2011
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 January 2011 Resolved
Provide proof of EAP surpervisor training.
Action required: 705 - Other - as specified
Due 13 March 2011
Resolved 13 March 2011
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 January 2011 Resolved
Repair all main engine and generator exhaust leaks and repair supports to all exhausts and the cooling water piping. Master to provide photos and statement when complete.
Action required: 705 - Other - as specified
Due 13 March 2011
Resolved 13 March 2011
Fire Fighting › Nozzles › Condition
Issued 2 June 2008 Resolved
Release tap for nose piecse forzen on tow of the four nozzles.
Condition: Improper/Lack of Maintenance
Due 5 June 2008
Resolved 5 June 2008
Lifesaving › Inflatable Liferafts › Container Construction
Issued 19 March 2007 Resolved
The life raft on the st side (forward) has 2 holes in the case. The case must be repaired or replaced & the life raft must be serviced (including an inflation test). to ensure there is no damage to the raft. The maximum number of persons onboard the vessel is reduced to 60 until the life raft is repaired or replaced. Received E-mail 20May08 fm [name withheld] attesting to repair.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 June 2008
Resolved 5 June 2008
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 19 March 2007 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 19 June 2008
Resolved 5 June 2008
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 27 February 2007 Resolved
Provide proper equipment to test the low lube oil pressure and high jacket water temperature shutdowns on the main engines and generators at the next annual inspection. Received E-mail dated 18 Apr 07 from Port [name withheld] attesting to items 2 & 3 are corrected. They shall remain open until verified to be corrected by attending USCG Marine Inspector.
Due 19 June 2008
Resolved 5 June 2008
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 January 2007 Resolved
Replace hoses iwa of keel coolers. Report cleared via phone dated 10 January 2007. Item remains open until cleared by attending Marine Inspector. See Activity 2832703.
Due 31 March 2007
Resolved 19 March 2007
Engineering › Steering Gear System › Piping
Issued 8 January 2007 Resolved
Properly support copper lines in engine room bilge. Report cleared via phone dated 10 January 2007. Item remains open until cleared by attending Marine Inspector. See Activity 2832703.
Due 31 March 2007
Resolved 19 March 2007
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 8 January 2007 Resolved
Properly mount junction box iwo engine room ventilation (stbd) in the engine room. Report cleared via phone dated 10 January 2007. Item remains open until cleared by attending Marine Inspector. See Activity 2832703.
Due 31 March 2007
Resolved 19 March 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 January 2007 Resolved
Replace water line going to engine exhaust. Report cleared via phone dated 10 January 2007. Item remains open until cleared by attending Marine Inspector. See Activity 2832703.
Due 31 March 2007
Resolved 19 March 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 January 2007 Resolved
Repair hole in the exhaust water seal. Report cleared via phone dated 10 January 2007. Item remains open until cleared by attending Marine Inspector. See Activity 2832703.
Due 31 March 2007
Resolved 19 March 2007
Construction/Loadline › Hull › Weld
Issued 8 January 2007 Resolved
Repair crack in weld iwo keel cooler in bilge. Report cleared via phone dated 10 January 2007. Item remains open until cleared by attending Marine Inspector. See Activity 2832703.
Due 31 March 2007
Resolved 19 March 2007
Construction/Loadline › Hull › Hull Plating
Issued 8 January 2007 Resolved
Repair cracks in the skeg and in the stbd outboard keel cooler.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 January 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 27 April 2006 Resolved
Replace faulty breaker on the #1 generator and demonstrate proper operation of the reverse power relay.
Action required: 705 - Other - as specified
Due 27 June 2006
Resolved 29 April 2006
Resolution: [name withheld]
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 27 April 2006 Resolved
Repair or replace louver wing nut and bolts so that the engine room air supply ducts can be closed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 May 2006
Resolution: [name withheld]
Communications › Audible Communications › SPD (Other)
Issued 27 April 2006 Resolved
Demonstrate proper operation of the public announcement/general alarm system.
Due 31 March 2007
Resolved 19 March 2007
Communications › Audible Communications › Horn/Whistle
Issued 27 April 2006 Resolved
Demonstrate proper operation of the air horn.
Action required: 705 - Other - as specified
Due 27 June 2006
Resolved 28 July 2006
Resolution: [name withheld]
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 April 2006 Resolved
Update charts and obtain West Africa Sailing Directions, Light List and Tide and Current Tables.
Action required: 705 - Other - as specified
Due 31 March 2007
Resolved 19 March 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 27 April 2006 Resolved
Remove excessive oil from bow thruster and generator room bilges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2006
Resolution: [name withheld]
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 27 April 2006 Resolved
Repair holed and wasted wet exhaust piping.
Action required: 15 - Rectify deficiencies by next port
Due 27 June 2006
Resolved 27 April 2006
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 27 April 2006 Resolved
Make bridge deck battery box watertight.
Action required: 705 - Other - as specified
Due 27 June 2006
Resolved 28 May 2006
Resolution: [name withheld]
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 27 April 2006 Resolved
Demonstrate proper operation of the following prime mover shutdown and alarms; over-speed, high jacket water temperature and low lube oil pressure.
Action required: 705 - Other - as specified
Due 31 March 2007
Resolved 18 April 2007
Resolution: See Edison Chouest Offshore Field ticket report dated 4/18/07
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 27 April 2006 Resolved
Repair fuel oil leak from port side main diesel engine
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 April 2006
Resolution: [name withheld]
Construction/Loadline › Structures › Transverse Bulkhead
Issued 27 April 2006 Resolved
Repair fracture on in the support on the port side of the bow thruster prop.
Action required: 705 - Other - as specified
Due 27 June 2006
Resolved 8 January 2007
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 27 April 2006 Resolved
Install 20x20 flame screens on the crankcase vents on the main deck, starboard side aft.
Action required: 705 - Other - as specified
Due 27 June 2006
Resolved 27 April 2006
Resolution: [name withheld]
Engineering › Steering Gear System
Issued 2 May 2003 Resolved
Tighten all fittings on steering system to ensure no hydraulic leaks. LEGACY COMPONENT DESC: Hydraulic Hose
Action required: 17 - Rectify deficiencies prior to departure
Due 2 June 2003
Resolved 2 May 2003
Communications › Alarms/Indicators › Bilge Alarm
Issued 4 April 2002 Resolved
REPAIR ENGINE ROOM BILGE HIGH WATER LEVEL ALARM LIGHT AT THE PILOTHOUSE CONTROLL STATION.
Condition: Improper/Lack of Maintenance
Due 4 April 2002
Resolved 4 April 2002
Construction/Loadline › Penetrations
Issued 4 April 2002 Resolved
REPAIR 1/4" X 1" AIR GAP CREATED DURING BLOWER INSTALLATION AT ENGINE ROOM AFT BKLHD AT STBD CORNER.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2002
Resolved 4 April 2002
Communications › Alarms/Indicators › General Alarm
Issued 4 April 2002 Resolved
PROPERLY LABEL GENERAL ALARM BUTTON ON THE PA SYSTEM.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2002
Resolved 4 April 2002
Navigation › Collision/Grounding Avoidance
Issued 4 April 2002 Resolved
PROPERLY INSTALL ANCHOR TO ENSURE A QUICK RELAIBLE RELEASE. LEGACY COMPONENT DESC: ANCHOR
Condition: Improper Installation
Due 4 April 2002
Resolved 4 April 2002
Construction/Loadline › Hull
Issued 4 April 2002 Resolved
REPAIR CRACKS IN BLOWER TRUNKS IWO THE PORT AND STBD DECK KNUCKLES. LEGACY COMPONENT DESC: SIDE SHELL
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 April 2002
Resolved 4 April 2002
Navigation
Issued 7 February 2000 Resolved
INSTALL RUDDER STOPS IN ACCORDANCE WITH 46CFR182.610(E) TO PREVENT JAMMING_x001C_AND DAMAGE TO THE RUDDER AND ITS FITTINGS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000
Deck/Cargo
Issued 7 February 2000 Resolved
REPLACE ANCHOR HOLD DOWN BOLTS ON STORAGE RACK WITH QUICK RELEASE _x001C_ ARRANGEMENT.
Condition: Unknown
Due 7 February 2000
Resolved 7 February 2000
Lifesaving
Issued 11 May 1998 Resolved
Provide rescue platform of proper size and demonstrate use of same to the satisfaction of the attending Marine Inspector.
Condition: Unknown
Due 11 June 1998
Resolved 25 May 1998

Ownership record