MAURY USCG vessel records Sign in
← All vessels

FRANCES

FRANCES is a 1957 passenger vessel (inspected). The Coast Guard has recorded 28 inspections since 1985, most recently in December 1994, along with 39 deficiencies.

Records from 1985 to 1994. Most recent: inspection, 28 December 1994.

Built
1957
Last inspected
28 December 1994
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAK2094
Flag
UNITED STATES
—
Maury page id
psix-43336

Inspections, by type

…with no type recorded8
Years with a record 10 calendar years (1985–1994)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 32 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it9 - Regulatory (Subpart C or D), Net Ton
14 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCG9951MMSI not assigned · expired · voluntarily equipped · granted 25 May 1994, cancelled 25 July 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 28

28 December 1994 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1159738
29 November 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1377305
20 May 1994 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1170214
25 April 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1167817
15 April 1994 Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 856779
13 April 1994 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 857782
10 December 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 849736
6 May 1993 Hull Examination · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1358066
14 April 1993 Re-Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1142728
5 May 1992 Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1266325
15 April 1991 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1196187
11 April 1991 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1237602
14 November 1990 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 900324
3 April 1990 Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 913997
17 April 1989 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1201183
11 April 1989 Hull Examination · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1194539
31 May 1988 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1200522
22 April 1988 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036719
9 December 1987 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1309687
16 June 1987 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1313342
8 April 1987 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1325007
18 November 1986 Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1324852
19 June 1986 Damage Survey
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1311657
11 April 1986 Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306583
3 April 1986 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1306770
16 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 979643
11 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 981375
4 April 1985 Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982743

Deficiency record · 39

Construction/Loadline
Issued 29 November 1994 Resolved
PRIOR TO CARRYING PASSENGERS, COMPLETE THE ENTIRE 42 ITEM WORKLIST ISSUED DURING ROUTINE HULL EXAMINATION AND PRESENT THE VESSEL FOR AN UNDERWAY EXAMINATION IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 30 April 1995
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 13 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS, REPAIR STERN PLANKING SO IT IS FLUSH WITH THESTERN FRAME AND WATERTIGHT.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Construction/Loadline
Issued 13 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS, ELIMINATE WATER WEEPAGE IN THE BILGE.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Engineering
Issued 13 April 1994 Resolved
MAKE PROPER PERMANENT REPAIRS TO THE MAIN ENGINE EXHAUST PIPE.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Construction/Loadline
Issued 13 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE CAPTIVE CHAINS AND SECURING DEVICES FOR ALL WEATHER DECK HATCHES.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Engineering
Issued 13 April 1994 Resolved
RENEW THE FLAME SCREEN ON THE STARBOARD FUEL TANK VENT.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Electrical
Issued 13 April 1994 Resolved
REMOVE DEAD-END WIRING FROM THE STARBOARD SIDE NEAR THE MAIN ENGINE.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Navigation
Issued 13 April 1994 Resolved
PROVIDE CURRENT EDITIONS OF TIDE, TIDAL CURRENT, LIGHT LIST AND CHARTS THATCOVER THE PERMITTED ROUTE ON THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Navigation
Issued 13 April 1994 Resolved
PROVIDE DEVIATION TABLES FOR EACH OF THE TWO COMPASSES, SPECIFIC TO EACH COMPASS.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Fire Fighting
Issued 13 April 1994 Resolved
PRIOR TO CARRYING PASSENGERS, PROVIDE PROPERLY SERVICED PORTABLE FIRE EXTINGUISHERS THAT ARE USCG APPROVED.
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Documentation
Issued 10 December 1993 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PRESENT EVIDENCE OF COMPLYING WITH THE CHEMICAL DRUG TESTING REGULATIONS (46 CFR PART 16).
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Documentation
Issued 10 December 1993 Resolved
PRIOR TO CARRYING MORE THAN SIX PASSENGERS FOR HIRE PROVIDE WRITTEN EVIDENCE TO THE OFFICER IN CHARGE MARINE INSPECTION PHILADELPHIA IDENTIFYING THE VESSEL'S OPERATOR(S) AND A COPY OF THEIR USCG MASTER'S LICENSE.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Construction/Loadline
Issued 14 April 1993 Resolved
MAKE THE PORT SIDE DECK DRAIN AT VESSEL'S MID-LENGTH WATERTIGHT AT SIDE HULL PLANKING PENETRATION
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 14 April 1993 Resolved
MARK NUMBER OF LIFE PRESERVERS STOWED IN EACH STOWAGE AREA.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 14 April 1993 Resolved
RENEW WORN WATERLIGHT ATTACHMENT LINE FOR BUOYANT APPARATUS AND REPLACE WITH 18' LINE.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Construction/Loadline
Issued 14 April 1993 Resolved
MAKE WATERTIGHT AT THE STEM PORTSIDE THE MINOR LEAK OF THE HULL PLANKING - RE-CAULK DURING DRYDOCKING.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Lifesaving
Issued 14 April 1993 Resolved
VESSEL RESTRICTED TO SEVENTEEN (17) TOTAL PASSENGERS UNTIL ONE (01) TYPE I USCG APPROVED LIFE PRESERVER IS PROVIDED.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Documentation
Issued 14 April 1993 Resolved
POST EMERGENCY CHECK-OFF PROCEDURES
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Accommodation/Occupational Safety
Issued 14 April 1993 Resolved
MARK MARINE SANITATION DEVICE DISCHARGE VALVE WITH THE FOLLOWING:_x001C_ "VALVE MUST BE KEPT CLOSED WHEN WITHIN 3 MILES OF SHORE".
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Documentation
Issued 14 April 1993 Resolved
PROVIDE TRAINING AND DOCUMENTATION OF TRAINING REQUIRED AS PER 46 CFR 16.401 (DRUG TESTING REGULATIONS).
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Fire Fighting
Issued 14 April 1993 Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE PROVIDE ONE SERVICEABLE B-II APPROVEDPORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 12 May 1993
Resolved 12 May 1993
Documentation
Issued 14 April 1993 Resolved
PROVIDE DOCUMENTATION OF RENEWAL OF FCC SAFETY CERTIFICATE EXPIRING 20MAY93
Condition: Unknown
Due 8 June 1993
Resolved 8 June 1993
Accommodation/Occupational Safety
Issued 5 May 1992 Resolved
RENEW/REPAIR RUBBER DISCHARGE HOSE CONNECTION AT BOTTOM OF MARINE SANITATION DEVICE TANK IN HEAD.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Lifesaving
Issued 5 May 1992 Resolved
VESSEL RESTRICTED TO 18 PERSONS UNTIL TWO ADULT TYPE I LIFE PRESERVERS ARE PROVIDED.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Lifesaving
Issued 5 May 1992 Resolved
REPLACE THE LINE ON THE RING BUOY WITH A MINIMUM OF 60 FT PRIOR TO CARRYINGPASSENGERS.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Navigation
Issued 5 May 1992 Resolved
IMPROVE FIT OF THE TILLER ON THE RUDDER POST.
Condition: Unknown
Due 23 June 1992
Resolved 23 June 1992
Navigation
Issued 11 April 1991 Resolved
PROVIDE A OPERATIONAL TEST OF THE PORTSIDE RUNNING LIGHT PRESENTLY INOPER-_x001C_ABLE.
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Lifesaving
Issued 11 April 1991 Resolved
PROVIDE (11) ADULT PFD'S WHERE TORN BEYOND REPAIR.
Condition: Unknown
Due 11 April 1991
Resolved 11 April 1991
Construction/Loadline
Issued 3 April 1990 Resolved
DRYDOCK VESSEL FOR REPAIR OF LEAKS NOTED AND MARKED BY INSPECTOR DURING UNDERWAY INTERNAL EXAM.
Condition: Unknown
Due 3 April 1990
Resolved 3 April 1990
Engineering
Issued 11 April 1989 Resolved
PROVIDE A HEAT DEFLECTOR FOR THE RACOR FUEL FILTER.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Lifesaving
Issued 11 April 1989 Resolved
DO THE FOLLOWING TO THE BUOYANT APPARATUS: 1) RENEW THE GRABLINE AND PENDANTS; 2) RESTENCIL CAPACITY; AND 3) REFIT WATERLIGHT. ALL TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Electrical
Issued 11 April 1989 Resolved
ELIMINATE THE DIRECT BATTERY TAPS.
Condition: Unknown
Due 11 April 1989
Resolved 11 April 1989
Lifesaving
Issued 22 April 1988 Resolved
PROVIDE 2 ADDITIONAL ADULT LIFE PRESERVERS. UNTIL THIS REQUIREMENT IS COMPLETED THE TOTAL PERSONS ALLOWED IS LIMITED TO 18.
Condition: Unknown
Due 22 April 1988
Resolved 22 April 1988
Navigation
Issued 22 April 1988 Resolved
DEMONSTRATE OPERATION OF RADAR ON ALL SCALES.
Condition: Unknown
Due 22 April 1988
Resolved 22 April 1988
Construction/Loadline
Issued 22 April 1988 Resolved
REPAIR THE PORT RUB RAIL AT THE AFTER END OF THE CABIN AND SEAL THE DESK ONTHE PORT SIDE OUTBOARD OF THE CABIN.
Condition: Unknown
Due 22 April 1988
Resolved 22 April 1988
Construction/Loadline
Issued 18 November 1986 Resolved
RENEW OR REPAIR THE RAW WATER HOLDING TANK WHICH IS USED INCONJUNCTION WITHTHE MARINE SANITATION DEVICE. MUST BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Construction/Loadline
Issued 18 November 1986 Resolved
MAKE VESSEL AVAILABLE FOR UNDERWAY CHECK PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Construction/Loadline
Issued 4 April 1985 Resolved
REPLACE THE NUMBER FOUR DECK BEAM DUE TO THE PRESENT ONE BEING SPLIT.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985
Navigation
Issued 4 April 1985 Resolved
MAKE REPAIRS TO STEERING GEAR DRIVE SHAFT TO PREVENT NUT FROM BACKING OFF SHAFT PIN.
Condition: Unknown
Due 4 April 1985
Resolved 4 April 1985

Ownership record