MAURY USCG vessel records Sign in
← All vessels

SIRIUS I

SIRIUS I is a 1996 tank ship. The Coast Guard has recorded 41 inspections since 1996, most recently in May 2014, along with 32 deficiencies and 15 operational controls.

Records from 1996 to 2014. Most recent: inspection, 16 May 2014.

Built
1996
Last inspected
16 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9111175 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
433435
Flag
BAHAMAS, THE
—
Maury page id
psix-433435

Inspections, by type

…with no type recorded22
Years with a record 13 calendar years (1996–2014)
The 41 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it13418 - Convention (Subpart B), Net Ton
28341 - Convention (Subpart B), Gross Ton
46341 - Dead Weight, Ton
56930 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

SEAWAYS FRAN Tank Ship · MISLE 39313 · 19 September 2003 · activity 1916661

Inspection history · 41

16 May 2014 ISPS II Exam · Administrative Inspection · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4860238
11 March 2009 ISPS II Exam · COC-TVE Renew · Ballast Water Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 3431550
22 December 2007 PII Safety Exam · COC-TVE Annual · Ballast Water Examination · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3119732
23 April 2007 Type not recorded
No type recorded · Sector Boston · USCG Northeast District (CGD-NE) · Activity 2914058
26 October 2006 PII Safety Exam · Ballast Water Examination · COC-TVE Renew · ISPS III Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2808387
9 April 2006 ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2620321
6 April 2006 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2618616
4 April 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2616649
4 April 2006 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2621428
3 March 2006 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2624139
31 January 2006 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2576764
3 October 2005 ISPS II Exam · COC-TVE Annual
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2507001
8 July 2005 ISPS II Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2419725
7 July 2005 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2418699
27 May 2005 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 2374464
4 May 2005 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2349087
17 November 2004 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2243100
17 September 2004 Ballast Water Examination · COC-TVE Renew
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2194645
1 July 2004 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2117017
1 July 2004 ISPS II Exam
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 2117544
13 April 2004 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2043562
14 February 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2006712
15 October 2003 Ballast Water Examination · Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1929270
11 October 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1930979
25 September 2003 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1913026
24 September 2003 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1911679
19 September 2003 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1916661
21 August 2003 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1879691
1 April 2003 Security Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1766414
8 September 2002 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1674838
29 August 2002 Certificate of Compliance · Tank Vessel Examination
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1668252
3 May 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 289713
3 May 2001 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1063480
22 May 2000 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 449175
3 May 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 277467
3 May 2000 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1049271
24 April 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 427704
24 April 1999 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 790677
25 May 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 404049
25 May 1997 Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1109117
14 March 1996 Type not recorded
No type recorded · COTP LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 388964

Deficiency record · 32

Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 May 2014 Resolved
"A" class divisions shall be so constructed as to prevent the passage of smoke and flame to the end of the one hour fire test. The main engine room door has several holes drilled through it. 74SOLAS(97) II-2/3.3.3
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 4 September 2014
Resolution: PSC NOLA received a class report from LR satisfying the requirement.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 May 2014 Resolved
The condition of the ship shall be maintained to conform with the provisions of the present regulations to ensure that ship will remain fit to proceed to sea without danger to the ship or persons on board. All self-closing doors in ladder way were not completely closing shut.
Action required: 705 - Other - as specified
Due 22 May 2014
Resolved 22 May 2014
Resolution: Chief engineer adjusted all self-closing doors in the ladder way allowing each door to completely close prior to the conclusion of our exam.
Navigation › Collision/Grounding Avoidance › Radar
Issued 4 May 2005 Resolved
04May2005- Issued an inbound LOD for an inoperable secondary radar (S-Band). Required to make repairs prior to departing San Francisco Bay.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 May 2005
Resolution: Received, via fax, a technicians report attesting to satisfactory repairs made to the S-Band radar. LOD is hereby resinded.
Documentation › Certificates/Documents › IOPP Certificate
Issued 17 September 2004 Resolved
Class to provide Oil Water Seperator maximum through put of system as required, but is not recorded on the IOPP. Class to fax updated IOPP.
Condition: Unknown
Due 3 October 2004
Resolved 27 September 2004
Resolution: Received faxed from Tomasos brother inc.
Engineering › Diesel Engine (propulsion-electric) › Gear, Timing
Issued 1 July 2004 Resolved
Rcvd report engine problems during inbound transit due to electrical malfunction
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2004
Resolved 2 July 2004
Deck/Cargo › Crude Oil Washing Systems
Issued 21 August 2003 Resolved
EXERCISE AND PROVE PROPER OPERATION OF COW VALVES ON MAIN DECK. LEGACY COMPONENT DESC: Isolating Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 21 August 2003 Resolved
EXERCISE AND PROVE PROPER OPERATION OF EMERGENCY DISCHARGE VALVES ON MAIN DECK.
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 21 August 2003 Resolved
REPLACE OR REWELD GUARD OVER PORT GANGWAY WIRES AND DRUM. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Deck/Cargo › Vapor Control Systems
Issued 21 August 2003 Resolved
PROPERLY STENCIL VAPOR CONTROL LINE.
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 22 August 2003
Engineering › Compressed Air System (control)
Issued 21 August 2003 Resolved
REPAIR SOFT PATCH ON AIR QUICK CONNECT UNDER H3B MANIFOLD. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 21 August 2003 Resolved
PORT SIDE EMERGENCY SHUTDOWN CONTROL BOX DOES NOT SECURE. LEGACY COMPONENT DESC: Closure Devices
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 21 August 2003 Resolved
REPAIR LEAK ON HYDRAULIC LINES TO CRANE.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Deck/Cargo › Inert Gas System
Issued 21 August 2003 Resolved
IGS BLOWER FAILURE ALARM NOT OPERATING PROPERLY.
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Engineering
Issued 21 August 2003 Resolved
REPAIR SIGHT GLASS ON INCINERATOR.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Engineering › Diesel Engine (auxiliary)
Issued 21 August 2003 Resolved
REPAIR EXHAUST LEAK ON #1 SSG.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Electrical › Electric Supply System (service)
Issued 21 August 2003 Resolved
PROPERLY INSTALL PUSH BUTTON BOX ON PORT MAIN DECK.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Construction/Loadline › Markings
Issued 21 August 2003 Resolved
LOADLINE NOT IN CONTRASTING COLOR TO THE HULL. LEGACY COMPONENT DESC: Load Line Mark
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Fire Fighting › Structural Fire Protection - General
Issued 21 August 2003 Resolved
ADJUST ALL FIRE DOORS IN STAIR CASE TO CLOSE AUTOMATICALLY. LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 21 August 2003 Resolved
HYDRAULIC OIL LEAK #9 SLOP TANK MAIN DECK AT THE FLANGE. LEGACY COMPONENT DESC: Closure Devices
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Deck/Cargo › Inert Gas System
Issued 21 August 2003 Resolved
MAKE PERMANENT REPAIRS TO FLANGE PIPE ON DECK WATER SEAL WHERE SENSOR IS INSTALLED. CLASS HAS GIVEN REPORT THAT THIS ITEM WILL BE CORRECTED AT NEXT DRYDOCK BY 31OCT03. LEGACY COMPONENT DESC: Water Seal
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 October 2003
Resolved 24 September 2003
Deck/Cargo › Vapor Control Systems
Issued 21 August 2003 Resolved
MAKE PERMANAENT REPAIRS TO THE #9 AND #6 P/V VAVLE. LEGACY COMPONENT DESC: Vessel Vapor Overpressure/Vacuum Protection
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 23 August 2003
Resolution: RCVD CLASS REPORT THAT VALVES ARE OPERATIONAL.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 21 August 2003 Resolved
MAKE PERMANENT REPAIRS TO THE FOLLOWING HYDRAULIC LINES: A) #2 PORT B) #1 TEST POINT STATION C) #6 HYDRAULIC SUPPLY LINE - LEAKING IN TWO PLACES.
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 23 August 2003
Resolution: RCVD CLASS REPORT THAT REPAIRS HAVE BEEN COMPLETED OR ARE SATISFACTORY.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 21 August 2003 Resolved
PROVE PROPER SERVICING OF FIXED CO2 SYSTEM - LEAD WIRE SEALS MISSING.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 23 August 2003
Resolution: SOTEC ISSUED SAT FIXED CO2 CONDITION REPORT.
Operations/Management › Vessel Safety Management
Issued 21 August 2003 Resolved
MASTER HAS NOT IMPLEMENTED POLICIES SET FORTH BY COMPANY, I.E. 55 GALLON DRUM OF GASOLINE FOUND ON STERN ABOUT 1/2 FULL. ALSO, AN ADDITIONAL DRUM WITH OIL AND RAGS WAS ON STERN. BOTH DRUMS WERE IN THE GARBAGE PILE. MASTE WAS UNAWARE OF BOTH. BRIDGE LOG NOT PROPERLY FILLED OUT (5.1.1). LEGACY COMPONENT DESC: Master''''s Responsiblity/Authority
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Operations/Management › Vessel Safety Management
Issued 21 August 2003 Resolved
MASTER WAS UNABLE TO PROVIDE / PROVE ANY TYPE OF CREW MOTIVATION IN THE SMS PROGRAM (5.1.2). THERE ARE NO RECORDS WITH PROOF CREWMEMBERS TAKE PART IN TRAINING PROGRAM, I.E. NO TRAINING IN FIREFIGHTING PROGRAM. LEGACY COMPONENT DESC: Master''''s Responsiblity/Authority
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Operations/Management › Vessel Safety Management
Issued 21 August 2003 Resolved
THERE ARE NO REPORTS OF INTERNAL SHIP INSTRUCTIONS CONDUCTED BY VESSEL, OR NON CONFORMITY REPORTS FOR DEPARTMENT HEAD OR CREW (9.1). LEGACY COMPONENT DESC: Company Responsibilities/Authority
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Operations/Management › Vessel Safety Management
Issued 21 August 2003 Resolved
MASTER IS NOT FULLY CONVERSANT WITH THE COMPANY SMS PROGRAM, I.E. UNABLE TO FIND POLICIES IN MANUALS OR HIS RESPONSIBILITY ISSUED BY COMPANY IN WRITING (6.1.2) LEGACY COMPONENT DESC: Master''''''''s Responsiblity/Authority
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Operations/Management › Vessel Safety Management
Issued 21 August 2003 Resolved
MAINTENANCE OF THE SHIP AND EQUIPMENT, I.E. NO PROOF OF INSPCTION OF VESSEL FOUND, NO NON-CONFORMING REPORTS MADE TO THE COMPANY FROM THE VESSEL. INTERNAL INSPECTION WITH POSSIBLE CAUSE. (10.2). LEGACY COMPONENT DESC: Maintenance of Ship/Equipment
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Electrical › Electric Supply System (service)
Issued 18 August 2003 Resolved
PROPERLY SUPPORT TWO CABLE RUNS ON PORT SIDE UNDER H3B MANIFOLD.
Action required: 705 - Other - as specified
Due 21 September 2003
Resolved 24 September 2003
Navigation › Collision/Grounding Avoidance
Issued 29 August 2002 Resolved
Vessel could not fix radar in port. Issued LOD to depart port of Charleston with Inop Secondary Radar. LEGACY COMPONENT DESC: Radar
Action required: 15 - Rectify deficiencies by next port
Resolved 7 September 2002
Resolution: RECIEVED FAXED CLASS REPORT REGARING THE PROPER OPERATION OF THE SECONDARY RADAR
Documentation
Issued 3 May 2000 Resolved
OIL TRANSFER PROCEDURES WRITTEN IN POLISH, [name withheld] GREEK AND ENGLISH. HAVE TRANSFER PROCEDURES RE-WRITTEN IN LANGUAGE UNDERSTOOD BY ALLINVOLVED PARTIES. CATAIN TO FAX CONTINUITY REPORT TO USCG, BY 03JUN00.
Condition: Unknown
Due 6 December 2000
Resolved 6 December 2000
Lifesaving
Issued 3 May 2000 Resolved
HYDRAULIC LINES FOR RESCUE BOAT HOIST RUPTURED DURING BOAT DRILL. REPAIR, AND FAX REPORT TO USCG, PRIOR TO DEPARTURE.
Condition: Unknown
Due 3 May 2000
Resolved 15 May 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.