Records in 1995. Most recent: inspection, 19 December 1995.
A report is not offered for this hull: Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. Reports.
Lifesaving
Issued 12 December 1995
Resolved
Properly install weak links on both 20 man liferafts starboardside IAW SOLAS III, reg 38.6.2. Sea painters on both liferafts were hard shackeled onto the brackets and no weak links were installed.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Lifesaving
Issued 12 December 1995
Resolved
Provide a fire retardent casing for the battery in the starboard lifeboat IAW SOLAS III, reg 41.6.9. Battery is currently left open to the elements.Correct prior to next U.S. voyage.
Condition: Unknown
Due 12 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 12 December 1995
Resolved
The M/V SAINT NECTARIOS was in violation of 33 CFR 155.450 when there was no oil discharge placard posted in a common space in the machinery space ofthe vessel.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Navigation
Issued 12 December 1995
Resolved
The M/V SAINT NECTARIOS was in violation of 33 CFR 164.35(k) when there wasno block diagram with simple operating instructions for emergency steering gear changeover procedures posted on the bridge.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Electrical
Issued 12 December 1995
Resolved
Repair all loose and bare wires observed leading from compartment on bridgewing to battery room IAW SOLAS II-1, reg 45.1.3.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Lifesaving
Issued 12 December 1995
Resolved
The seals were broken on the 25 man liferaft on the portside and the 6 man liferaft forward. Vessel must provide servicing for both liferafts and present a copy of the servicing report to the USCG prior to next U.S. voyage.
Condition: Unknown
Due 12 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 12 December 1995
Resolved
Repair/replace 3 self igniting lights for lifebouys throughout the vessel IAW SOLAS III, reg 7.1.3. 3 lights were inoperable and full of sea water.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Lifesaving
Issued 12 December 1995
Resolved
Provide a quick release mechanism for the light and smoke combination on both bridgewing life buoys IAW SOLAS III, reg 31.1.7. Light and smoke was observed to be not in a quick release setup. Correct prior to next U.S. voyage.
Condition: Unknown
Due 12 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 12 December 1995
Resolved
The M/V SAINT NECTARIOS was in violation of 33 CFR 164,.35(g) when the manuevering fact sheet was missing the time and distance to stop criteria. In addition, the fact sheet was written in Portugese, a language not understood by the crew. Correct prior to next U.S. voyage.
Condition: Unknown
Due 12 January 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Navigation
Issued 12 December 1995
Resolved
The M/V SAINT NECTARIOS was in violation of 33 CFR 164.33(a)(3)(i) when there was no tide tables for 1995 on the vessel.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995
Navigation
Issued 12 December 1995
Resolved
The M/V SAINT NECTARIOS was in violation of 33 CFR 164.33(a)(3)(ii) when there was no 1995 tidal current table onboard the vessel.
Condition: Unknown
Due 12 December 1995
Resolved 12 December 1995