Records from 1985 to 2025. Most recent: inspection, 24 October 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 58
24 October 2025
In-Service Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8258228
3 September 2025
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8209203
21 July 2025
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8140639
8 July 2025
Hull Examination · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8179127
16 April 2025
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8071276
2 May 2024
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7868321
31 October 2023
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7739900
18 May 2023
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654398
14 April 2022
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7426943
27 October 2021
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7340356
21 April 2021
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7179791
22 June 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6984199
30 October 2019
Hull Examination · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6711898
29 April 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6636683
2 May 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6367627
1 November 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6265786
25 April 2017
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6097772
4 May 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5824988
28 October 2015
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5216193
3 May 2012
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4274815
4 January 2012
Simplified Stability Test
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4046936
28 December 2011
Plan Review "T" Boat · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4214976
6 May 2009
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3467828
19 February 2009
DAPI Audit
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3429048
7 May 2008
Re-Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3176401
23 October 2007
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3084936
11 May 2007
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2921498
3 August 2006
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2728324
8 December 2005
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2546238
3 November 2005
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2524224
1 February 2005
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2281654
14 April 2004
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2040763
20 October 2003
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1930054
10 October 2002
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1688143
8 August 2002
Plan Review "T" Boat · Hull Examination · Construction Oversight · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1658380
10 November 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 784721
7 October 1996
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1158095
18 September 1996
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1434446
11 June 1996
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377835
31 October 1995
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1398347
15 July 1994
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1409158
21 June 1994
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1389836
26 October 1993
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1431290
28 July 1993
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 845834
2 October 1992
Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 959659
3 September 1991
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 939320
19 August 1991
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1246302
10 January 1991
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1216088
7 January 1991
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 905707
1 June 1989
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 887019
31 May 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1194046
6 May 1988
Re-Inspection · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1347911
8 October 1987
Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1013866
30 April 1987
Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1328449
30 April 1986
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1308483
4 March 1986
Credit Drydock
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 986826
13 March 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 979525
13 March 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 983316
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 3 September 2025
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Mach. space missing dedicated ventilation closure device. Provide closing device to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2025
Resolution: Vessel installed a ventilation closure with latches.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 September 2025
Resolved
A vessel on an oceans, coastwise, limited coastwise, or Great Lakes route must carry—Six hand orange smoke distress signals approved in accordance with § 160.037. Vessel missing (3) orange smoke signals. Provide to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2025
Resolution: Additional (3) orange smoke provided.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 3 September 2025
Resolved
A marine employer whose vessel is involved in a casualty or incident that is, or is likely to become, a serious marine incident as defined in § 4.03-2 of subchapter A of this chapter shall comply with the requirements of § 4.06 in subchapter A of this chapter. Missing alcohol testing device. Provide alcohol testing device to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 September 2025
Resolution: (2) Alcohol test strips provided.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 3 September 2025
Resolved
Except as provided in paragraph (c) of this section, a vessel must be provided with an auxiliary means of steering that is:(1) Of adequate strength;(2) Capable of moving the rudder from 15 degrees on one side to 15 degrrees on the other side in not more than 60 seconds with the vessel at one-half its maximum service speed ahead, or 7 knots, whichever is greater. Aux steering tiller did not function at the time of inspection. Provide satisfactory operational test to the satisfaction of the attending marine inspector.
Action required: 10 - Deficiency Rectified
Resolved 4 September 2025
Resolution: System is designed to be closed. No bypass available. Performed set up and discussed procedures underway.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 3 September 2025
Resolved
The owner, managing operator, or a qualified servicing facility as applicable must conduct the following inspections and tests:(1) Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Galley 40 B:C portable fire extinguisher was not serviced. Provide annual service report the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 10 September 2025
Resolution: Extinguisher serviced by Joy fire.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 3 September 2025
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: (1) Date of the drill and training; and
(2) General description of the drill scenario and training topics. Vessel was missing drill logs. Provide all drill logs to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 10 September 2025
Resolution: Drill logs provided.
09 - Working and Living Conditions › 091 - Living Conditions › Record of inspection
Issued 3 September 2025
Resolved
Monthly inspections required by NFPA 10 may be conducted by the owner, operator, person-in-charge, or a designated member of the crew. Conduct monthly inspection and provide log to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 10 September 2025
Resolution: Inspection log provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 3 September 2025
Resolved
The EPIRB test required by paragraph (a) shall be logged or otherwise documented, as applicable. Vessel missing EPRIB monthly inspection logs. Provide record and log of test to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 10 September 2025
Resolution: Inspection log provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 September 2025
Resolved
The number and identification of the items stowed inside
, and their sizes, must be marked in clearly legible
letters and numbers on each container for life jackets.
Letters and numbers must be at least 2 inches high. Label life jacket storage for adult and child life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 10 September 2025
Resolution: Storage labeled for adult and children.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 3 September 2025
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date: (1) Charts of large
enough scale to make safe navigation possible. Provide
valid electronic navigation charts to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 10 September 2025
Resolution: Charts provided.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 3 September 2025
Resolved
Section 151.57 (Garbage Management Plans) applies to—(1) A manned oceangoing ship (other than a fixed or floating drilling rig or other platform) of 40 feet or more in length Vessel was missing garbage management plan. Provide garbage management plan to the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 10 September 2025
Resolution: Plan posted.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 3 September 2025
Resolved
A vessel must comply with the applicable requirements including the requirements for a station license and installation certificates to be issued by the Federal Communications. Provide emergency radio broadcast instructions and post FCC radio certificates.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 September 2025
Resolved 10 September 2025
Resolution: FCC Radio requirements posted.
Engineering › Bilge Water Management System › Valve
Issued 25 April 2017
Resolved
iNSTALL A SCREW-DOWN VALVE IN THE FIXED BILGE PIPING SYSTEM, FORWARD OF THE COLLISION BULKHEAD.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 4 May 2017
Resolution: SEE NARRATIVE
Navigation › Piloting/Steering › Marine Charts
Issued 25 April 2017
Resolved
Make vessel's operating charts up-to-date, last correction from 2014.
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 4 May 2017
Resolution: SEE NARRATIVE
Operations/Management › Drug and Alcohol Testing › Testing, Substances
Issued 25 April 2017
Resolved
Witness new alcohol test strips.
Action required: 705 - Other - as specified
Resolved 25 April 2017
Resolution: Fixed on the spot.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 April 2017
Resolved
Post vessel's certificate of inspection viewable to passengers.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 25 April 2017
Resolution: Fixed on the spot.
Documentation › Certificates/Documents › FCC SSL
Issued 3 May 2012
Resolved
Vessel had an expired FCC Station License.
Action required: 705 - Other - as specified
Due 17 May 2012
Resolved 9 May 2012
Resolution: Received new license.
Stability › Watertight Integrity › General
Issued 23 October 2007
Resolved
Plug and make watertight two through bulkhead openings in forward collision bulkhead.
Action required: 705 - Other - as specified
Due 6 November 2007
Resolved 24 October 2007
Resolution: Bulkhead openings plugged and made watertight.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 October 2003
Resolved
Post original COI under glass in a conspicuous place.
Action required: 705 - Other - as specified
Due 20 October 2003
Resolved 20 October 2003
Resolution: Corrected on the spot; posted a copy of the COI until the amended original arrives.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 20 October 2003
Resolved
Post emergency broadcast placard next to radio.
Action required: 705 - Other - as specified
Due 20 October 2003
Resolved 20 October 2003
Resolution: Corrected on the spot.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 20 October 2003
Resolved
Provide satisfactory evidence of the required servicing of the fixed firefighting system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 November 2003
Resolved 4 November 2003
Resolution: Received fixed firefighting servicing report from South Coast Fire Protection.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 October 2003
Resolved
Did not throw lifering during MOB drill.
Action required: 705 - Other - as specified
Due 20 October 2003
Resolved 20 October 2003
Resolution: Corrected on the spot.
Documentation
Issued 7 October 1996
Resolved
Provide onboard a valid certificate of documentation prior to operating thevessel._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 November 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 7 October 1996
Resolved
Properly mount the battery isolation breaker in accordance with 46CFR183.
Condition: Unknown
Due 7 November 1996
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 18 September 1996
Resolved
Submit for approval a single line drawing of AC and DC electrical system toinclude source of power, wire size, cable length (DC only), circuit protection and load. Electrical system must be approved before vessel operates with passengers.
Condition: Unknown
Due 18 September 1996
Resolved 19 September 1996
Navigation
Issued 18 September 1996
Resolved
Repair upper rudder bearing support. Vessel may not carry passengers until this item is completed.
Condition: Unknown
Due 18 September 1996
Resolved 19 September 1996
Lifesaving
Issued 18 September 1996
Resolved
Provide serviceable seapainter for lifefloats. This item must be corrected before vessel operates with passengers.
Condition: Unknown
Due 18 September 1996
Resolved 19 September 1996
Lifesaving
Issued 18 September 1996
Resolved
Provide 24" ring bouy. This item must be corrected before vessel operates with passengers.
Condition: Unknown
Due 18 September 1996
Resolved 19 September 1996
Engineering
Issued 18 September 1996
Resolved
Repair port emergency fuel shutoff so that it can be operated from main deck at all times. This item must be repaired before vessel operates with passengers.
Condition: Unknown
Due 18 September 1996
Resolved 19 September 1996
Electrical
Issued 18 September 1996
Resolved
Install circuit protection in power supply from battery to D.C. distribution panal. This item must be corrected before vessel operates withpassengers.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Accommodation/Occupational Safety
Issued 18 September 1996
Resolved
Mark emergency escape in forward part of cabin.
Condition: Unknown
Due 18 September 1996
Resolved 19 September 1996
Electrical
Issued 18 September 1996
Resolved
Demonstrate operation of generator. Generator may not be operated with passengers aboard until approved by attending marine inspector.
Condition: Unknown
Due 18 October 1996
Resolved 21 October 1996
Construction/Loadline
Issued 18 September 1996
Resolved
Secure all pumps below decks on vessel.
Condition: Unknown
Due 18 September 1996
Resolved 19 September 1996
Electrical
Issued 18 September 1996
Resolved
Provide properly sized cable from battery charger to batteries as per 46 CFR Part 183.
Condition: Unknown
Due 25 September 1996
Resolved 21 October 1996
Engineering
Issued 18 September 1996
Resolved
Mark emergency fuel shutoff on deck.
Condition: Unknown
Due 18 September 1996
Resolved 19 September 1996
Unknown
Issued 11 June 1996
Resolved
ADVISED OWNER THAT VESSEL CANNOT CARRY PASSENGERS FOR HIRE UNTIL WORKLIST FROM THE 31MAY96 DRYDOCK IS CORRECTED.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Electrical
Issued 31 October 1995
Resolved
Provide properly constructed battery box.
Condition: Unknown
Due 14 November 1995
Resolved 29 November 1995
Construction/Loadline
Issued 31 October 1995
Resolved
Repair damaged area port bow as original.
Condition: Unknown
Due 31 October 1995
Resolved 31 October 1995
Electrical
Issued 31 October 1995
Resolved
Provide adequate bonding system thru-out engine room.
Condition: Unknown
Due 14 November 1995
Resolved 29 November 1995
Accommodation/Occupational Safety
Issued 31 October 1995
Resolved
Properly label emergency escape hatch IAW 46 CFR 185.30-15.
Condition: Unknown
Due 14 November 1995
Resolved 29 November 1995
Fire Fighting
Issued 31 October 1995
Resolved
Hydro test B-II fire extinguishers.
Condition: Unknown
Due 14 November 1995
Resolved 29 November 1995
Construction/Loadline
Issued 31 October 1995
Resolved
Provide handle for portable bilge pump.
Condition: Unknown
Due 14 November 1995
Resolved 29 November 1995
Engineering
Issued 31 October 1995
Resolved
Provide flame screens on fuel vents.
Condition: Unknown
Due 14 November 1995
Resolved 29 November 1995
Lifesaving
Issued 31 October 1995
Resolved
Total persons limited to 29 until additional PFD is provided.
Condition: Unknown
Due 14 November 1995
Resolved 7 November 1995
Lifesaving
Issued 31 October 1995
Resolved
Replace 1 oar for use with life float.
Condition: Unknown
Due 14 November 1995
Resolved 7 November 1995
Navigation
Issued 31 October 1995
Resolved
Provide local charts and light list.
Condition: Unknown
Due 14 November 1995
Resolved 29 November 1995
Lifesaving
Issued 31 October 1995
Resolved
Provide seperation between Adult and Child PFD stowage areas.
Condition: Unknown
Due 14 November 1995
Resolved 13 December 1995
Construction/Loadline
Issued 21 June 1994
Resolved
BILGE PIPING PASSING THROUGH COLLISION BULKHEAD TO BE RENEWED TO ORIGINAL.
Condition: Unknown
Due 21 June 1994
Resolved 21 June 1994
Engineering
Issued 26 October 1993
Resolved
Provide and install belt and rotating machinery guards.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Lifesaving
Issued 26 October 1993
Resolved
Provide vessel with five (05) additional adult P.F.D.s. Vessel may only carry a total of twenty-five (25) persons on board until corrected.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Engineering
Issued 26 October 1993
Resolved
Repair and prove proper operation of main engine tachometer.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Engineering
Issued 26 October 1993
Resolved
Repair and prove proper operation of main engine throttle control.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Electrical
Issued 26 October 1993
Resolved
Cover unused openings in circuit breaker box.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Engineering
Issued 26 October 1993
Resolved
Provide and install heat shields for all Racor fuel filters.
Condition: Unknown
Due 10 December 1993
Resolved 10 December 1993
Documentation
Issued 19 August 1991
Resolved
PROVIDE ALL REQUIRED RADIO EQUIPMENT OUTLINED IN 47 CFR 80.905(a)(3), OR OBTAIN AN EXEMPTION FROM FCC. VESSEL ROUTE LIMITED TO NO MORE THAN 100 NAUTICAL MILES FROM THE NEAREST LAND UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Documentation
Issued 19 August 1991
Resolved
PROVIDE DOCUMENTATION TO SUPPORT COMPLIANCE WITH THE PROGRAM FOR CHEMICAL DRUG AND ALCOHOL TESTING OF COMMERCIAL VESSEL PERSONNEL IN ACCORDANCE WITH 46 CFR 16.
Condition: Unknown
Due 19 August 1991
Resolved 19 August 1991
Construction/Loadline
Issued 7 January 1991
Resolved
REPAIR GLASS CRACK LOCATED APPROX 3 FEET AFT OF THE STEM STARBOARD SIDE TO THE SATISFATCION OF THE ATTENDING COAST GUARD INSPECTOR
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Construction/Loadline
Issued 7 January 1991
Resolved
REPAIR DAMAGE TO STEM LOCATED JUST BELOW THE RAIL AT THE BOW TO THE _x001C_ SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR
Condition: Unknown
Due 7 January 1991
Resolved 7 January 1991
Documentation
Issued 1 June 1989
Resolved
PROVIDE CURRENT DOCUMENTATION SHOWING OWNER.
Condition: Unknown
Due 1 June 1989
Resolved 1 June 1989
Unknown
Issued 1 June 1989
Resolved
STENCIL NAME OF VESSEL ON PT. & STBD. BOW AND NAME & HOMEPORT ON STERN.
Condition: Unknown
Due 1 June 1989
Resolved 1 June 1989
Lifesaving
Issued 1 June 1989
Resolved
RE-STRING BOTTOM NETS ON BOTH LIFEFLOATS.
Condition: Unknown
Due 1 June 1989
Resolved 1 June 1989
Navigation
Issued 1 June 1989
Resolved
RENEW STEERING GEAR BRACKETS.
Condition: Unknown
Due 1 June 1989
Resolved 1 June 1989
Electrical
Issued 6 May 1988
Resolved
COMPLETE INSTALLATION OF AUX GENERATOR AND TEST SAME.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Accommodation/Occupational Safety
Issued 6 May 1988
Resolved
COMPLETE INSTALLATION OF MSD SYSTEM AND TEST SAME.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Navigation
Issued 6 May 1988
Resolved
REPAIR STERN LIGHT.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Electrical
Issued 8 October 1987
Resolved
SECURE ELECTRICAL WIRES TO PREVENT FROM CONTACT WITH THE BILGES.
Condition: Unknown
Due 8 October 1987
Resolved 8 October 1987
Electrical
Issued 8 October 1987
Resolved
REMOVE ALL ELECTRICAL WIRES THAT ARE NOT IN SERVICE.
Condition: Unknown
Due 8 October 1987
Resolved 8 October 1987
Electrical
Issued 8 October 1987
Resolved
REPAIR ELECTRICAL WIRING SPLICES WITH A METAL CRIMP CONNECTOR.
Condition: Unknown
Due 8 October 1987
Resolved 8 October 1987
Lifesaving
Issued 30 April 1987
Resolved
RESTENCIL EMERGENCY FUEL SHUTOFF ON WEATHERDECK
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Fire Fighting
Issued 30 April 1987
Resolved
SERVICE ALL HAND HELD PORTABLE EXTINGUISHERS
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Fire Fighting
Issued 30 April 1987
Resolved
PROVIDE HAND HELD FIRE PUMP
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Navigation
Issued 30 April 1987
Resolved
RENEW EPIRB BATTERY
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Construction/Loadline
Issued 30 April 1987
Resolved
PROVIDE CAPTURE CHAINS ON ALL FLUSH DECK HATCHES
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Lifesaving
Issued 30 April 1987
Resolved
RENEW WEAK LINK WIRE ON FLOAT FREE APPARATUS
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Lifesaving
Issued 30 April 1987
Resolved
PROVIDE STACKING STRIPS BETWEEN LIFE FLOATS
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Lifesaving
Issued 30 April 1987
Resolved
PROVIDE 3 HAND HELD ORANGR FLARES
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Navigation
Issued 30 April 1987
Resolved
PRESENT COMPASS DEVIATION CARD
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Navigation
Issued 30 April 1987
Resolved
PROCURE COAST PILOT,LIGHT LIST,TIDE TABLES AND TIDAL CURRENT TABLES
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Navigation
Issued 30 April 1987
Resolved
PROVIDE 8 INCH BELL
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Electrical
Issued 30 April 1987
Resolved
PROPERLY MAKE UP DECK PA SYSTEM
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Electrical
Issued 30 April 1987
Resolved
PROPERLY MAKE UP WIRING CONNECTIONS ON GENERATOR SET
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Lifesaving
Issued 30 April 1987
Resolved
REPLACE POWER CELLS IN PFD LIGHTS WITH AUTHORIZED BATTERIES
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Electrical
Issued 30 April 1987
Resolved
PROVIDE ROTATING MACHINERY GUARD FOR GENERATOR SET IN ER
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Engineering
Issued 30 April 1987
Resolved
REPLACE FUEL HOSE ON GEN SET WITH AUTHORIZED FUEL LINE
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Accommodation/Occupational Safety
Issued 30 April 1987
Resolved
PROVIDE VENT TO ER BILGE IAW 46CFR182.20-45(C)(D)
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Construction/Loadline
Issued 13 March 1985
Resolved
SECURE ELECTRICAL CABLE , FLEXIBLE BILGE PUMP HOSE , GENERATOR MUFFLER IN ENGINE ROOM.
Condition: Unknown
Due 13 March 1985
Resolved 13 March 1985
Engineering
Issued 13 March 1985
Resolved
REMOVE / REPLACE STBD FUEL TANK. FILL WITH WATER PRIOR TO OPERTATING.
Condition: Unknown
Due 13 March 1985
Resolved 13 March 1985
Construction/Loadline
Issued 13 March 1985
Resolved
MAKE TIGHT 12" COAMING AROUND ENGINE ROOM AND COMPT BELOW BAIT TANK. SECUREHATCH.
Condition: Unknown
Due 13 March 1985
Resolved 13 March 1985
Construction/Loadline
Issued 13 March 1985
Resolved
INSTALL REACH ROD ABOVE MAIN DECK FOR FOREPEAK SUCTION LINE VALVE OR RELOCATE VALVE IN PASSENGER CABIN AT FWD BULKHEAD.
Condition: Unknown
Due 13 March 1985
Resolved 13 March 1985
Construction/Loadline
Issued 13 March 1985
Resolved
SCRAPE AND TREAT DRY ROT IN ENGINE ROOM OVERHEAD PROT AND IN COMPARTMENT BELOW BAIT TANK.
Condition: Unknown
Due 13 March 1985
Resolved 13 March 1985
Engineering
Issued 13 March 1985
Resolved
DOUBLE CLAMP SALT WATER HOSES IN ENGINE ROOM.
Condition: Unknown
Due 13 March 1985
Resolved 13 March 1985