Records from 1995 to 2020. Most recent: inspection, 8 October 2020.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 14
8 October 2020
Bulk Liquid Transfer Monitor
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7074062
10 July 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 291606
24 January 2001
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 286236
16 August 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 281175
11 July 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 279697
18 May 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 277955
29 February 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 275301
4 February 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 274335
26 January 2000
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 273915
27 July 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 431001
15 July 1999
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 430610
29 August 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 407452
3 May 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 403317
10 November 1995
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 384757
Electrical
Issued 11 July 2000
Resolved
Emergency generator has an exhaust leak inside emergemcy generator room. Required to repair leak and provide class report prior to 11 Aug00.
Condition: Unknown
Due 16 August 2000
Resolved 16 August 2000
Engineering
Issued 26 January 2000
Resolved
Sludge pump inoperable, air pump being used. Repair renew provide class report.
Condition: Unknown
Due 29 February 2000
Resolved 29 February 2000
Construction/Loadline
Issued 26 January 2000
Resolved
Hatch cover not closing properly. Hinge pins being repaired. Repair renew provide class report.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Fire Fighting
Issued 26 January 2000
Resolved
Emergency fire pump can't take suction due to vessel trim. Once vessel is loaded and trim is adjusted prove proper operation.
Condition: Unknown
Due 28 January 2000
Resolved 28 January 2000
Fire Fighting
Issued 26 January 2000
Resolved
Emergency fire pump suction piping is supplied directly from the ballast main, which must be flooded to supply the fire pump. System not approved. Existing arrangement to be approved by class prior to return Jacksonville. Warning sign to be posted by Emergency fire pump and ballast station.
Condition: Unknown
Due 9 February 2000
Resolved 9 February 2000
Accommodation/Occupational Safety
Issued 15 July 1999
Resolved
SEWAGE SYSTEM IS A TYPE II. VSL HAS NO CHEMICAL ON BOARD. UNIT TO BE SECURED WHILE IN US WATERS. UNIT TO BE BROUGHT UP TO MANUFACTURE SPEC'S WITH SPARE CHEMICAL ONBOARD. PROVIDE STATEMENT FROM FLAG THAT UNIT IS FULLYOPERATIONAL PRIOR TO RETURN TO US WATERS.
Condition: Unknown
Due 1 August 1999
Resolved 1 August 1999
Documentation
Issued 15 July 1999
Resolved
VESSEL SAILING WITHOUT ONE AB BY SAFE MANNING DOC. PROVIDE CREW MEMBER AS PER SAFE MANNING DOC. PRIOR TO RETURN TO US WATERS
Condition: Unknown
Due 1 August 1999
Resolved 1 August 1999
Construction/Loadline
Issued 15 July 1999
Resolved
OILY WATER SEPERATOR INOP. NO WATER TO SENSOR, VALVE WILL NOT DUMP WHEN OILLIGHT LIT. REPAIR/RENEW AND PROVIDE CLASS REPORT PRIOR TO RETURN US WATERS.
Condition: Unknown
Due 1 August 1999
Resolved 1 August 1999
Fire Fighting
Issued 15 July 1999
Resolved
VESSELS CREW UNABLE TO CONDUCT PROPER FIRE AND BOAT DRILLS. CONDUCT FIRE AND BOAT DRILL UPON RETURN TO PORT OF JACMS.
Condition: Unknown
Due 1 August 1999
Resolved 1 August 1999
Documentation
Issued 3 May 1997
Resolved
PROVIDE MUSTER LIST AND EM CREW INSTRUCTIONS LISTING CREW DUTIES.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Documentation
Issued 3 May 1997
Resolved
PROVIDE EVIDENCE OF LOGGED TEST IAW 33CFR164.25.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Lifesaving
Issued 3 May 1997
Resolved
ADD NAME AND HOME PORT TO LIFEVESTS.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Fire Fighting
Issued 3 May 1997
Resolved
PROVIDE EVIDENCE OF CURRENT FIRE EXTINGUISHER SERVICING.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997
Navigation
Issued 3 May 1997
Resolved
PROVIDE DIRECTIONS AND BLOCK DIAGRAM OF STEERING PROCEEDURES AT BRIDGE AND AFT STEERING.
Condition: Unknown
Due 2 September 1997
Resolved 2 September 1997