MOKU HANA 1

Built
1995
Last inspected
21 September 2022
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 21 September 2022
…with no type recorded2
…past their stated due date1
Operational controls None recorded without a removal date
Years with a record 7 calendar years (2016–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG4283
433601
Flag
UNITED STATES
Maury page id
psix-433601

Documentation record

Registered dimensions (L × B × D)32.5 ft × 10.0 ft × 5.8 ft
Registered tonnagegross 12 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderAMERICAN EAGLE MANUFACTURING INC · LA CONNER, WA, UNITED STATES · built 1995
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portHONOLULU, HI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 30 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it12 - Simplified, Gross Ton
10 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 12 inspections, each with its date, unit and type; 49 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 12

21 September 2022 Construction Oversight · Plan Review "T" Boat
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7588494
2 November 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7344222
23 February 2021 Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7144592
1 July 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6994031
11 January 2020 Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 6887648
11 January 2020 Type not recorded
No type recorded · Station Honolulu · USCG Oceania District (CGD-O) · Activity 6887652
11 June 2019 Administrative Inspection · Internal Structural Exam · COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6711141
5 March 2019 Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6636953
8 January 2018 Administrative Inspection · COI Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6334499
9 June 2017 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6170132
4 October 2016 Administrative Inspection · COI Inspection · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6013551
6 January 2016 Administrative Inspection · Annual Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5791752

Deficiency record · 49

11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 1 July 2020 Resolved
A vessel on a limited coastwise route must carry six hand red flare distress signals and six hand orange smoke signals. A red hand flare distress signal may be substituted for any of the hand orange smoke distress signals. Vessel has eight red flare distress signals and three hand orange smoke signals. Vessel must provide one additional red flare or orange smoke distress signal to meet this regulation. 46 CFR 180.68
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2020
Resolved 2 July 2020
Resolution: Vessel provided additional flare.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 July 2020 Resolved
A vessel not required to have a power driven fire pump by 181.300 must have at least three 2 1/2 gallon buckets, with an attached lanyard satisfactory to the cognizant OCMI. Vessel was missing one fire bucket. 46 CFR 181.610
Action required: 17 - Rectify deficiencies prior to departure
Due 1 July 2020
Resolved 2 July 2020
Resolution: Vessel provided 3rd fire bucket.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 July 2020 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). VHF radio missing MMSI and LAT/LONG for DSC operation. 47 CFR 80.905
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2020
Resolved 1 August 2020
Resolution: Vessel purchased new radio with built in GPS and input MMSI number.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 July 2020 Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection against fire, explosion, machinery failure, and personnel injury. Fuel tank fill hose deteriorate near attachment to tank. Renew hose. 46 CFR 182.01-5 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2020
Resolved 30 July 2020
Resolution: Vessel renewed fuel tank hose.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 July 2020 Resolved
All cable and wire must be installed with metal supports spaced not more than 24 inches apart. Secure loose wiring in engine compartment. 46 CFR 183.340(b)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 August 2020
Resolved 30 July 2020
Resolution: Vessel secured loose wiring.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 1 July 2020 No resolution recorded
A vessel must comply with the structural design requirements of one of the standards listed. Vessel has pitting in transverse frames in fuel tank void up to 3/16" deep in 1/4" stock. Repairs must be completed during credit drydock, no later than March 31st 2021. 46 CFR 177.300
Action required: 705 - Other - as specified
Due 3 April 2021 — due date passed with no resolution recorded
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 June 2019 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment under all practicable conditions. Submersible electric bilge pumps and hi-level alarm floats are not secured. Properly secure submersible electric pumps and associated float switches.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2019
Resolved 17 June 2019
Resolution: Bilge pumps and high water alarms secured in bilge.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 13 June 2019 Resolved
Vessels must comply with applicable requirements for radios installations, including issuance of certificates issued by the FCC. FCC Safety Radiotelephony Certificate was found expired. Provide proof of issuance of current FCC Safety Radiotelephony Certificate.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2019
Resolved 17 June 2019
Resolution: Current FCC Radiotelephony Cert provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 June 2019 Resolved
Fuel shut-off valves are to be operable from outside the space that the valve is located. Fuel shut-off valve at the tank did not properly close when operated. Prove proper operation/closure of fuel shut off valve at the fuel tank from the main deck.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2019
Resolved 17 June 2019
Resolution: Cable adjusted to allow fuel shut off valve to properly close when activated.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2019 Resolved
Portable fire extinguishers are to be inspected as frequency specified by NFPA 10. Vessel did not have record of monthly inspection. Create monthly inspection log and document.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 June 2019
Resolved 17 June 2019
Resolution: Monthly fire extinguisher log created and updated.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 January 2018 Resolved
Provide offical log to prove completion of emergency drills 46 CFR 185.520(f)
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 23 January 2018
Resolution: Vessel owner provided official log to prove completion of emergency drills.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 19 January 2018 Resolved
Provide updated CG light list. 46 CFR 184.420(a)
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 23 January 2018
Resolution: Vessel owner provided up to date CG light list
Operations/Management › Equipment Service/Testing › EPIRB
Issued 19 January 2018 Resolved
Provide official log to prove monthly EPRIB testing. 46 CFR 185.728
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 23 January 2018
Resolution: Vessel owner provided log to prove monthly testing of EPIRB.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 January 2018 Resolved
Replenish or replace expired iodine swabs and eye wash in first aid kit. 46 CFR 184.710
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 23 January 2018
Resolution: Vessel owner provided new iodine swabs and eye wash for first aid kit.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 19 January 2018 Resolved
Provide proof of EAP Supervisory training. 46 CFR 16.401
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 24 January 2018
Resolution: Vessel owner provided documentation of supervisor EAP training.
Fire Fighting › Fire Bucket › Lanyard
Issued 19 January 2018 Resolved
Provide lanyard for fire bucket. 46 CFR 181.610
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 23 January 2018
Resolution: Vessel owner provided lanyard for fire bucket
Engineering › Bilge Water Management System › Pump
Issued 19 January 2018 Resolved
Prove proper operation of aft bilge pump. 46 CFR 182.520(c)
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 23 January 2018
Resolution: Vessel owner proved proper operation of aft bilge pump.
Engineering › Bilge Water Management System › Interface Detector
Issued 19 January 2018 Resolved
Prove proper operation of aft bilge pump visual indicator at operating station. 46 CFR 182.530(c)
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 23 January 2018
Resolution: Vessel owner proved proper operation of aft bilge pump visual indicator at operating station.
Stability › Watertight Integrity › General
Issued 19 January 2018 Resolved
Make propulsion controls watertight at operating station. 46 CFR 183.210(b)
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 23 January 2018
Resolution: Propulsion controls made watertight at operating station.
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 19 January 2018 Resolved
Install suitable shutoff valve for sewage tank vent thru-hull penetration. 46 CFR 182.720(d)(1)(ii)
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 23 January 2018
Resolution: Sewage Tank thru-hull penetration was plugged.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 January 2018 Resolved
Provide securing device for stbd hatch cover. 46 CFR 179.360(b)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Due 26 January 2018
Resolved 23 January 2018
Resolution: A securing device was installed for stbd hatch cover.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 January 2018 Resolved
Vessel may not operate with greater than 6 passengers until successful completion of an inspection for certification. 46 CFR 176.502
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 February 2018
Resolved 23 January 2018
Resolution: Issued TCOI after completion of COI Renewal.
Engineering › Bilge Water Management System › Not Operational
Issued 4 October 2016 Resolved
Forward compartment bilge high water level alarm inoperable. Ensure audio alarm is functional prior to sail.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2016
Resolution: Bilge high water audible alarm functional to the satisfaction of attending Coast Guard marine inspector.
Construction/Loadline › Hull › Hull Plating
Issued 4 October 2016 Resolved
Material condition of hull internals demonstrates excessive corrosion; clean and prepare for further inspection to determine wastage.
Condition: Improper/Lack of Maintenance
Due 4 November 2016
Resolved 26 October 2016
Resolution: Surface of hull prepared for inspection.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 4 October 2016 Resolved
Equipment servicing records including EPIRB monthly tests not available for inspection; make logbooks and records available for inspection.
Condition: Improper/Lack of Maintenance
Due 4 November 2016
Resolved 26 October 2016
Resolution: Equipment servicing records including EPIRB monthly tests made available.
Navigation › Piloting/Steering › Marine Charts
Issued 4 October 2016 Resolved
Nautical chart onboard is out of date; provide current nautical chart.
Condition: Improper/Lack of Maintenance
Due 4 November 2016
Resolved 26 October 2016
Resolution: Nautical chart updated.
Engineering › Fuel Oil Service System › Piping
Issued 4 October 2016 Resolved
Fuel fill line bonding strap missing; ensure bonding strap for fuel tank fill line installed.
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 26 October 2016
Resolution: Deficiency rectified.
Construction/Loadline › Structures › Superstructure
Issued 4 October 2016 Resolved
Hole in superstructure overhead; repair to original design.
Condition: Improper/Lack of Maintenance
Due 4 November 2016
Resolved 26 October 2016
Resolution: Hole in superstructure overhead repaired satisfactory.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 4 October 2016 Resolved
Mid watertight hatch not watertight; ensure hatch is watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2016
Resolved 12 December 2016
Resolution: New watertight hatch installed.
Engineering › Fuel Oil Service System › Hose
Issued 4 October 2016 Resolved
Fuel lines to port and starboard engine chaffing; provide chaffing gear accordingly.
Condition: Improper/Lack of Maintenance
Due 4 November 2016
Resolved 26 October 2016
Resolution: Chaffing gear provided for fuel lines.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 4 October 2016 Resolved
Starboard engine water cooling hose deteriorated; replace.
Due 4 November 2016
Resolved 12 December 2016
Resolution: Engine water cooling hose replaced.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 4 October 2016 Resolved
Wing nuts on battery terminals not permanent type; ensure connectors are of permanent type.
Condition: Improper Installation
Due 4 November 2016
Resolved 26 October 2016
Resolution: Permanent type connectors installed on batteries.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 4 October 2016 Resolved
Port engine compartment hatch not watertight; ensure hatch is watertight.
Condition: Improper/Lack of Maintenance
Due 4 November 2016
Resolved 26 October 2016
Resolution: Port engine compartment hatch made watertight.
Construction/Loadline › Penetrations › Valve Flange
Issued 4 October 2016 Resolved
Through holes in port side of vessel hull, separated from the hull; provide repair proposal.
Condition: Improper/Lack of Maintenance
Due 21 November 2016
Resolved 2 June 2017
Resolution: Through holes repaired.
Construction/Loadline › Hull › Bottom Plating
Issued 4 October 2016 Resolved
Bottom plating in vessel hull within bilge area contains extensive pitting; provide repair proposal.
Condition: Improper/Lack of Maintenance
Due 21 November 2016
Resolved 2 June 2017
Resolution: Vessel hull cropped and renewed.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 February 2016 Resolved
Post COI under transparent material so that all pages are visible.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 7 March 2016
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 February 2016 Resolved
Provide certificate of documentation prior to operation
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 March 2016
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 17 February 2016 Resolved
Provide proof of enrollment to include company policy, members enrolled, and consortium information
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 7 March 2016
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 17 February 2016 Resolved
Replace line on waterlight to ring buoy
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 7 March 2016
Lifesaving › Hand Flares › Quantity
Issued 17 February 2016 Resolved
Provide appropriate number of distress flares for a limited coastwise route
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 7 March 2016
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 February 2016 Resolved
Provide appropriate contents of first aid kit to include eye wash and eye bandages
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 7 March 2016
Documentation › Logs/Records › Logbook (official)
Issued 17 February 2016 Resolved
Provide logs for fire and man overboard drills conducted.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 7 March 2016
Documentation › Logs/Records › Logbook (official)
Issued 17 February 2016 Resolved
Provide log of EPIRB testing
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 7 March 2016
Navigation › Piloting/Steering › Marine Charts
Issued 17 February 2016 Resolved
Provide an up-to-date chart
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 7 March 2016
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 17 February 2016 Resolved
Replace 1 child sized life jacket. Passenger count is restricted to 1 person under 90 pounds
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 March 2016
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 17 February 2016 Resolved
Replace retroreflective tape on 1 adult life jacket. Passenger count is reduced to 15 adults until renewed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 7 March 2016
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 17 February 2016 Resolved
Provide proof of maintenance for 3 onboard portable fire extinguishers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 7 March 2016
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 17 February 2016 Resolved
Install deck rails to meet 39.5 inch height requirement with 4 inch courses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 March 2016
Resolved 7 March 2016
Resolution: Determined to be a non-issue based on Sector Honolulu guidance and Old T standards
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 17 February 2016 Resolved
Provide AED to meet requirements of WI 31 for reduced mannin endorsement. Vessel is not to operate under reduced manning until AED is onboard
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 7 March 2016

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.