Records from 1995 to 2026. Most recent: inspection, 22 June 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 29
22 June 2026
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8407269
24 March 2025
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8099035
21 March 2024
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7890118
30 March 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7684617
14 March 2022
COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7403320
16 March 2021
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7171992
17 March 2020
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6926292
18 June 2019
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6717802
20 March 2019
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6643445
12 April 2018
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6362059
11 April 2017
Deficiency Check · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 6121366
21 April 2016
Annual Inspection
Physical examination · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 5825779
12 May 2014
Annual Inspection
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4825071
3 February 2012
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 4237759
16 March 2010
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3682346
2 April 2009
Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3445182
17 March 2009
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3428678
2 April 2008
Annual Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3179028
26 March 2007
Deficiency Check · COI Inspection · Hull Examination
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2883467
17 March 2006
Annual Inspection · Deficiency Check
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 2599756
1 April 2005
Annual Inspection · Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2290738
31 March 2004
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 2022108
26 March 2003
Deficiency Check · Annual Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1756377
18 February 2000
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1046077
20 April 1999
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1125894
16 April 1998
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 789676
28 May 1997
COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 778324
28 January 1997
Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1103630
9 November 1995
Hull Examination · Deficiency Check · Plan Review "T" Boat · Initial Certification
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1380336
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 24 March 2025
Resolved
Owner/Operator was not able to show proof of being enrolled in a chemical testing program as per 46CFR16. Required O/O to re-enroll in a testing program and obtain test strips. Informed O/O they cannot operate until enrolled.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 31 March 2025
Resolution: O/O sent proof of being enrolled in a proper testing program and test strips.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 March 2025
Resolved
Bilge pump did not work during testing. O/O does not have any immediate trips planned and will repair asap.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2025
Resolution: O/O sent video of working bilge pump, all sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2023
Resolved
The port engine remote fuel shutoff valve was inop. Repair prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 April 2023
Resolution: Rcvd video of operational fuel valve. All sat.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 March 2019
Resolved
Prove proper operation of installed fire system to satisfaction of Marine Inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2019
Resolved 17 March 2020
Resolution: Witnessed proper operation of safety function check of installed fire fighting system. All, sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 March 2019
Resolved
Prove proper operation of port side fuel shut off to satisfaction of Marine Inspector, prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2019
Resolved 17 March 2020
Resolution: Witnessed proper articulation of fuel shut off.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 April 2018
Resolved
Post life-jacket donning procedures for the style/model of life-jackets carried aboard the vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2018
Resolution: Owner posted laminated life-jacket donning procedures aboard the vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 April 2018
Resolved
Provide one additional 10-B:C portable fire extinguisher.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2018
Resolution: Owner purchased an additional 10-B:C fire extinguisher and mounted it aboard the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 12 April 2018
Resolved
Replace damaged ventilation ducting in the engine compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2018
Resolution: Owner replaced the damaged section of ventilation ducting on the suction side of the ventilation/exhaust fan in the engine compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 12 April 2018
Resolved
Prove proper operation of the port fuel cut-off valve. This valve must be operable from the remote pull station located outside the engine compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2018
Resolution: Vessel owner replaced the emergency fuel cut-off valve; valve tested satisfactorily from the remote pull station.
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 11 April 2017
Resolved
Provide State Registration to attending Marine Inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Resolution: Received visual documentation via email that the State Registration is current.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 April 2017
Resolved
Limit total number of passengers to 12 until 15 lifejackets have been placed into service. Provide evidence of 15 lifejackets to attending Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Resolution: Received visual documentation which demonstrates all required lifejackets are onboard the vessel.
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 April 2017
Resolved
Post lifejacket donning placard in public view.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Resolution: Received visual documentation that a lifejacket donning placard has been mounted onboard the vessel.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 April 2017
Resolved
Provide eyewash which is not expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Resolution: Received email from licensed mariner which states that the eye wash solution was replaced with unexpired solution.
Construction/Loadline › Hull › Weld
Issued 11 April 2017
Resolved
Repair welds called out by attending Marine Inspector in accordance with discussed repair plan.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 May 2017
Resolved 12 May 2017
Resolution: Received visual evidence that the welds which were cracked have been repaired IAW discussed repair proposal.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 16 March 2010
Resolved
Provide proof of current state registration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2010
Resolved 26 April 2010
Resolution: Received copy of current state reg
Lifesaving › Lifebuoys › Not on Board
Issued 16 March 2010
Resolved
Provide life ring buoy and place onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2010
Resolved 26 April 2010
Resolution: Received owner statement that he placed new life ring on board.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 17 March 2009
Resolved
Make Fire Boy audible alarm operable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2009
Resolved 2 April 2009
Resolution: Received e-mail from [name withheld] stating he replaced the audible alarm and tested sat.
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 March 2009
Resolved
Make bilge audible alarm operable.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 April 2009
Resolved 2 April 2009
Resolution: Replaced the audible alarm test sat.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 26 March 2007
Resolved
Renew life ring with 24" life ring, ensure vessels name is stenciled and retro reflective tape is applied.
Due 30 March 2007
Resolved 27 March 2007
Resolution: Corrected
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 26 March 2007
Resolved
Provide 01 adult life jacket for a total onboard count of 20.
Due 30 March 2007
Resolved 27 March 2007
Resolution: Corrected.
Construction/Loadline › Penetrations › Valve Flange
Issued 26 March 2007
Resolved
Make wash down pump thru hull fitting of similar or stronger strength as hull of vessel. Additionally provide a mechanical valve or cock as close to hull as possible to prevent water engress.
Due 30 March 2007
Resolved 27 March 2007
Resolution: Corrected.
Fire Fighting › Fire Bucket › Stenciling
Issued 16 March 2006
Resolved
Label fire bucket "FIRE BUCKET".
Due 16 April 2006
Resolved 17 March 2006
Resolution: Corrected
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 16 March 2006
Resolved
Prove proper operation of fume detector.
Due 16 April 2006
Resolved 17 March 2006
Resolution: Corrected
Fire Fighting › Remote Fuel Shutoff › General
Issued 16 March 2006
Resolved
Prove proper operation of port fuel shutoff system.
Due 16 April 2006
Resolved 17 March 2006
Resolution: Corrected
Fire Fighting › Ventilation Systems › Ducts
Issued 16 March 2006
Resolved
Renew port aft ducting in the engine compartment.
Due 16 April 2006
Resolved 17 March 2006
Resolution: Corrected
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 March 2006
Resolved
Have onboard in the engine space a properly serviced fixed halon fire extinguisher; prior to carriage of passengers.
Due 16 April 2006
Resolved 23 May 2006
Resolution: Completed
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 16 March 2006
Resolved
Label the location of the child's life jackets to coincide with how many life jackets are stored in each compartment.
Due 16 March 2006
Resolved 17 March 2006
Resolution: Corrected
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 April 2005
Resolved
Repair aft navigation light (stern light). (COLREGS 74 & 46 CFR 183.420)
Due 1 May 2005
Resolved 17 May 2005
Resolution: Replace bulb, light operational.
Fire Fighting › Ventilation Systems › Ducts
Issued 1 April 2005
Resolved
Provide six (6) vent closures for the cowl vents on vessel. (46 CFR 182.460)
Due 1 May 2005
Resolved 17 May 2005
Resolution: Vent closures provided.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 1 April 2005
Resolved
Prove proper operation of the fume detector. (46 CFR 182.480)
Due 1 May 2005
Resolved 17 May 2005
Resolution: Detector replaced and is operational.
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 1 April 2005
Resolved
Install duct seal for wires conduit between engine room and accommodation space. (46 CFR 176.800)
Due 1 May 2005
Resolved 17 May 2005
Resolution: Duct seal reapplied.
Lifesaving › Lifejacket/PFD (General)
Issued 31 March 2004
Resolved
Reduce passenger load to 14 people until 4 adult sized lifejackets are provided.
Due 1 May 2004
Resolved 6 May 2004
Lifesaving › Lifejacket/PFD (General)
Issued 31 March 2004
Resolved
Stencil vessel lifejackets with name LEGACY COMPONENT DESC: Marking
Due 1 May 2004
Resolved 6 May 2004
Engineering › Gasoline Engine (propulsion)
Issued 31 March 2004
Resolved
Clean flame screens installed in drip pans and repair as needed.
Due 1 May 2004
Resolved 6 May 2004
Fire Fighting
Issued 31 March 2004
Resolved
Provide one fire bucket.
Due 1 May 2004
Resolved 6 May 2004
Documentation › Markings/Placards
Issued 31 March 2004
Resolved
Label emergency exits.
Due 1 May 2004
Resolved 6 May 2004
Stability › Unintentional Flooding
Issued 26 March 2003
Resolved
Repair or replace the audible alarms for the bilge high water level and the fixed fire fighting systems. 46 CFR 182.530 and 46 CFR 181.420 Complete prior to the carriage of passengers. LEGACY COMPONENT DESC: Audible High Level Bilge Alarm
Condition: Improper Installation
Due 26 April 2003
Resolved 9 May 2003
Fire Fighting
Issued 26 March 2003
Resolved
Provide one (1) fire bucket for vessel. 46 CFR 181.610 LEGACY COMPONENT DESC: FIRE BUCKET
Condition: Unknown
Due 26 April 2003
Resolved 9 May 2003
Engineering › Fuel Oil Service System
Issued 26 March 2003
Resolved
Replace or clean both fuel drip-pan screens under fuel filters. 46 CFR 182.455 LEGACY COMPONENT DESC: Drip Pan Screens
Condition: Improper/Lack of Maintenance
Due 26 April 2003
Resolved 9 May 2003
Engineering
Issued 26 March 2003
Resolved
Replace both ventilation supply hoses on the port and stbd sides of the engine room. 46 CFR 176.800 LEGACY COMPONENT DESC: Engine Ventilation Ducting
Condition: Improper/Lack of Maintenance
Due 26 April 2003
Resolved 9 May 2003
Fire Fighting › Miscellaneous Items
Issued 26 March 2003
Resolved
Prove one (1) hand bilge pump (5GPM). 46 CFR 182.520 LEGACY COMPONENT DESC: Hand Bilge Pump
Condition: Unknown
Due 26 April 2003
Resolved 9 May 2003
Documentation
Issued 9 November 1995
Resolved
PROVIDE COPY OF VESSEL'S STATE REGISTRATION.
Condition: Unknown
Due 20 November 1995
Resolved 22 November 1995
Documentation
Issued 9 November 1995
Resolved
PROVIDE COPY OF MASTER'S LICENSE.
Condition: Unknown
Due 18 December 1995
Resolved 18 December 1995