MAURY USCG vessel records
← All vessels

CROW ARROW

Built
1957
Last inspected
15 January 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 15 January 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WAG6169
Flag
UNITED STATES
Maury page id
psix-43366

Documentation record

Registered dimensions (L × B × D)39.3 ft × 13.9 ft × 5.4 ft
Registered tonnagegross 20 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderHOOD RIVER, OR, UNITED STATES · built 1957
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT ANGELES, WA
Endorsements, as the file codes themcw_un, fi, reg
DocumentationValid · issued 12 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 8 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

15 January 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299801
24 January 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8069674
1 November 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8029078
24 October 2023 Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7813510
16 December 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7612372
31 October 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7587117
4 February 2022 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7417471
28 January 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7392221
27 January 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7127177
15 October 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7078152
31 January 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6900411
2 November 2018 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6572962
15 October 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6559691
21 August 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6519095
8 August 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6234644
25 May 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6155447
8 June 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5921777

Deficiency record · 8

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2025 Resolved
Fuel oil return cross over (between tanks) hose incorrect material, incorrect fittings, and leaking. Renew hose with material meeting SAE J1942 and fittings meeting SAE J1475. Completed assembly should not leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 24 January 2025
Resolution: Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 November 2023 Resolved
Vessel must have at least 3 buckets with an attached lanyard. 01 fire bucket missing lanyard.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 November 2023
Resolved 6 November 2023
Resolution: New lanyard attached to fire bucket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2023 Resolved
Each life jacket must be marked clearly with the vessel's name. 01 adult lifejackets found with incorrect vessel name marking.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 6 November 2023
Resolved 6 November 2023
Resolution: Adult lifejacket replaced with correct markings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 November 2023 Resolved
Bilge system must be fitted with a suitable strainer. 02 bilge pickups were demonstrated as operational after on-site servicing. Operation of bilge pickup in lazarette was not operational during inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2023
Resolved 9 November 2023
Resolution: Bilge system serviced and retested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2022 Resolved
Flexible hose must be fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid. The vessels marine gear filter hose was missing a flame retardant sleeve (Sheath). Replace hose with proper sleeve or add a sleeve to the current hose. 46 CFR 182.715(e)(3)(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2022
Resolved 2 February 2022
Resolution: Hoses properly sleeved.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 28 January 2022 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5C (150 Degrees Fahrenheit) must be suitably insulated where necessary to prevent injuries. Vessel is missing part of its lagging on the exhaust manifold. Add lagging to exposed part of exhaust manifold. 46 CFR 177.970
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2022
Resolved 4 February 2022
Resolution: New lagging installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2022 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference). Vessel had the wrong type of lube oil sump drain hose that did not meet the standards for nonmetallic piping materials in vital systems. Replace with approved nonmetallic hose. 46 CFR 182.720(e)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2022
Resolved 4 February 2022
Resolution: Hoses replaced.
Construction/Loadline › Hull › Hull Plating
Issued 25 May 2017 Resolved
Complete a credit dry-dock/ISE prior to re-entering service.
Action required: 705 - Other - as specified
Resolved 10 August 2017
Resolution: Completed DDX/ISE.

Ownership record