Inspections, by type

…with no type recorded7
Years with a record 37 calendar years (1985–2026)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)39.3 ft × 13.9 ft × 5.4 ft
Registered tonnagegross 20 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · HOOD RIVER, OR, UNITED STATES · built 1957
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT ANGELES, WA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 12 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WAG6169MMSI 366974070 · active · compulsorily equipped · granted 24 July 2024, expires 12 October 2034
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 65

15 January 2026 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8299801
24 January 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8069674
1 November 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8029078
24 October 2023 Deficiency Check · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7813510
16 December 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7612372
31 October 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7587117
4 February 2022 Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7417471
28 January 2022 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7392221
27 January 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7127177
15 October 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7078152
31 January 2020 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6900411
2 November 2018 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6572962
15 October 2018 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6559691
21 August 2018 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6519095
8 August 2017 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6234644
25 May 2017 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6155447
8 June 2016 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5921777
25 August 2015 Drydock Exam · Internal Structural Exam · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5225053
20 August 2014 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4960586
27 March 2014 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4832499
2 February 2012 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4235478
8 December 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4204296
1 November 2010 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3884125
12 February 2009 Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3413315
16 April 2008 Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3184049
21 February 2007 Hull Examination · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2888938
27 January 2005 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2282058
27 January 2005 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2282064
7 January 2005 Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2270893
30 October 2003 Annual Inspection · Internal Structural Exam · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1825040
2 July 2002 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1640143
13 December 2001 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1076911
28 August 2001 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1072259
14 February 2001 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1058888
24 August 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 822893
10 May 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 183176
6 January 2000 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1365512
16 March 1999 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1465455
11 March 1999 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1453555
15 March 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1371650
9 January 1997 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1411396
27 February 1996 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1416253
5 January 1995 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 855947
12 January 1994 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1161796
17 May 1993 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 839802
6 May 1993 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1137664
6 May 1993 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1137665
16 July 1992 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 957472
25 June 1992 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1265174
17 June 1992 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1256455
5 May 1992 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1259874
6 March 1992 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1317467
3 March 1992 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1008762
17 January 1991 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 927649
21 December 1990 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 912059
14 February 1990 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 922199
31 January 1990 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 929251
3 January 1990 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 928184
18 December 1989 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1213193
31 May 1989 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1039010
10 June 1988 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1201445
15 June 1987 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1002739
21 April 1987 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1312756
12 May 1986 Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1295221
12 June 1985 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1292474

Deficiency record · 47

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2025 Resolved
Fuel oil return cross over (between tanks) hose incorrect material, incorrect fittings, and leaking. Renew hose with material meeting SAE J1942 and fittings meeting SAE J1475. Completed assembly should not leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2025
Resolved 24 January 2025
Resolution: Deficiency rectified.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 6 November 2023 Resolved
Vessel must have at least 3 buckets with an attached lanyard. 01 fire bucket missing lanyard.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 6 November 2023
Resolved 6 November 2023
Resolution: New lanyard attached to fire bucket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 November 2023 Resolved
Each life jacket must be marked clearly with the vessel's name. 01 adult lifejackets found with incorrect vessel name marking.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 6 November 2023
Resolved 6 November 2023
Resolution: Adult lifejacket replaced with correct markings.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 November 2023 Resolved
Bilge system must be fitted with a suitable strainer. 02 bilge pickups were demonstrated as operational after on-site servicing. Operation of bilge pickup in lazarette was not operational during inspection.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2023
Resolved 9 November 2023
Resolution: Bilge system serviced and retested sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2022 Resolved
Flexible hose must be fabricated with an inner tube and a cover of synthetic rubber or other suitable material reinforced with wire braid. The vessels marine gear filter hose was missing a flame retardant sleeve (Sheath). Replace hose with proper sleeve or add a sleeve to the current hose. 46 CFR 182.715(e)(3)(i)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2022
Resolved 2 February 2022
Resolution: Hoses properly sleeved.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 28 January 2022 Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5C (150 Degrees Fahrenheit) must be suitably insulated where necessary to prevent injuries. Vessel is missing part of its lagging on the exhaust manifold. Add lagging to exposed part of exhaust manifold. 46 CFR 177.970
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2022
Resolved 4 February 2022
Resolution: New lagging installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 January 2022 Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942 (incorporated by reference). Vessel had the wrong type of lube oil sump drain hose that did not meet the standards for nonmetallic piping materials in vital systems. Replace with approved nonmetallic hose. 46 CFR 182.720(e)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2022
Resolved 4 February 2022
Resolution: Hoses replaced.
Construction/Loadline › Hull › Hull Plating
Issued 25 May 2017 Resolved
Complete a credit dry-dock/ISE prior to re-entering service.
Action required: 705 - Other - as specified
Resolved 10 August 2017
Resolution: Completed DDX/ISE.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 25 August 2015 Resolved
Vessel is required to complete an annual inspection within 3 months before or after each anniversary date. Vessel failed to complete their 3rd annual inspection no later than 02MAY15. Vessel shall complete an Inspection for Certification prior to conducting operations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 September 2015
Resolution: Completed inspection for certification to the satisfaction of attending Marine Inspector.
Lifesaving › Buoyant Apparatus › Capacity
Issued 20 August 2014 Resolved
Vessel shall carry a 6 person IBA and reduce passengers allowed onboard to 18, until the vessel's 15-person IBA is properly serviced and placed back onboard.
Action required: 705 - Other - as specified
Resolved 10 November 2014
Resolution: IBA serviced and placed back onboard the CROW ARROW.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 February 2012 Resolved
Provide one child lifejacket. Limited to two children until corrected
Action required: 705 - Other - as specified
Due 2 March 2012
Resolved 27 February 2012
Resolution: Received invoice via email that the one child lifejacket has been ordered and is onboard. May operated in accordance with COI. All sat
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 April 2008 Resolved
Prove proper operation of masthead light. Vessel restricted to daylight hours only.
Due 15 May 2008
Resolved 7 May 2008
Resolution: Operator was found to have not flipped the correct switch. Masthead light did function properly when the correct switch was flipped.
Lifesaving › Embarkation Appliances/Stations › Accessability
Issued 16 April 2008 Resolved
Add a man overboard ladder of adequate size.
Due 23 April 2008
Resolved 29 May 2008
Resolution: Installed MOB ladder
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 16 April 2008 Resolved
Permanently mount weather deck fire extinguisher.
Due 23 April 2008
Resolved 7 May 2008
Lifesaving › Lifefloat › Paddle
Issued 21 February 2007 Resolved
Replace broken oars in lifefloat.
Due 21 March 2007
Resolved 15 March 2007
Engineering › Bilge Water Management System › Piping
Issued 21 February 2007 Resolved
Install valve closer to skin of vessel in O/B discharge piping, stbd midship void.
Due 21 March 2007
Resolved 15 March 2007
Stability › Freeing Ports › General
Issued 21 February 2007 Resolved
Open freeing ports for increased drainage. Remove or replace hard rubber flappers.
Due 21 March 2007
Resolved 15 March 2007
Stability › Freeing Ports
Issued 12 December 2003 Resolved
Forward port freeing port cover was siezed. The cover (flap) was not easily operable. In this condition, the freeing port would not perform satisfactory. No 835 issued, corrected on the spot.
Condition: Improper/Lack of Maintenance
Due 12 December 2003
Resolved 12 December 2003
Resolution: Freeing port cover was removed and replaced with a new one.
Construction/Loadline › Penetrations
Issued 12 December 2003 Resolved
Sewage discharge sea valve was incapable of fully closing. No 835 issued, corrected on the spot.
Condition: Unknown
Due 12 December 2003
Resolved 12 December 2003
Resolution: Sea valve was replaced and inspected satisfactory.
Lifesaving › Buoyant Apparatus
Issued 30 October 2003 Resolved
Cracks in lifefloat. Water light missing from life float. Buoyant line not properly attached to life float (not wrapped around body of lifefloat). Repair cracks in lifefloat, install water light, and properly attach buoyant line prior to carrying passengers.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 November 2003
Lifesaving › Lifejacket/PFD (Type II)
Issued 30 October 2003 Resolved
Eight (8) lifejackets are not serviceable. Replace eight (8) lifejackets prior to carrying more than 20 passengers. Complete to the satisfaction of the attending Marine Inspector. LEGACY COMPONENT DESC: Condition
Condition: Unknown
Due 6 November 2003
Resolved 6 November 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 30 October 2003 Resolved
Vessel has crack in main engine exhaust pipe flex coupling. Crack must be repaired to satisfaction of the attending Marine Inspector prior to November 6, 2003. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Unknown
Due 6 November 2003
Resolved 6 November 2003
Resolution: Crack in flex coupling closed by welding.
Engineering › Fuel Oil Storage/Transfer System
Issued 30 October 2003 Resolved
Missing flame arrestor screens on fuel vent pipes. Replace screens to the satisfaction of the attending Marine Inspector prior to November 6, 2003. LEGACY COMPONENT DESC: Vent Pipe
Condition: Unknown
Due 6 November 2003
Resolved 12 December 2003
Resolution: 30x30 mesh screens installed.
Construction/Loadline
Issued 24 August 2000 Resolved
REPAIR OR REPLACE MISSING SECURING DEVICES ON ALL REMAINING ARROW LAUNCH ENGINE ROOM HATCH COVERS TO COMPLY WITH 46 CFR SUB-G 171.124
Condition: Unknown
Due 24 August 2000
Resolved 24 August 2000
Lifesaving
Issued 11 March 1999 Resolved
make buoyant apparatus float-free arrangement and attach tag line and weak link.
Condition: Unknown
Due 25 March 1999
Resolved 17 March 1999
Construction/Loadline
Issued 11 March 1999 Resolved
Complete repairs to bulwark forward of frame 3.
Condition: Unknown
Due 25 March 1999
Resolved 23 March 1999
Construction/Loadline
Issued 11 March 1999 Resolved
Make repairs to hole in starboard side hull at frame 7.
Condition: Unknown
Due 25 March 1999
Resolved 17 March 1999
Electrical
Issued 11 March 1999 Resolved
Remove dead end wires from Port side main engine.
Condition: Unknown
Due 11 April 1999
Resolved 17 March 1999
Construction/Loadline
Issued 11 March 1999 Resolved
Crop and renew wasted transverse frames 20,21, and 26 starboard side at weather deck.
Condition: Unknown
Due 25 March 1999
Resolved 23 March 1999
Construction/Loadline
Issued 11 March 1999 Resolved
Make repairs to Port side forward stanchion between frames 8 and 9.
Condition: Unknown
Due 25 March 1999
Resolved 23 March 1999
Engineering
Issued 5 January 1995 Resolved
REPLACE FLAME SCREENS FOR FUEL TANK VENTS.
Condition: Unknown
Due 28 January 1995
Resolved 28 January 1995
Accommodation/Occupational Safety
Issued 5 January 1995 Resolved
REPLACE PORT WINDOW FWD IN PASSENGER COMPARTMENT.
Condition: Unknown
Due 28 January 1995
Resolved 28 January 1995
Engineering
Issued 5 January 1995 Resolved
PERMANENTLY SECURE KEEL COOLER HOSE FWD OF ENGINE.
Condition: Unknown
Due 28 January 1995
Resolved 28 January 1995
Navigation
Issued 5 January 1995 Resolved
PROVE PROPER OPERATION OF AUXILIARY STEERING GEAR.
Condition: Unknown
Due 28 January 1995
Resolved 28 January 1995
Construction/Loadline
Issued 5 January 1995 Resolved
PROVIDE LANYARD FOR AFT COMPARTMENT HATCH.
Condition: Unknown
Due 28 January 1995
Resolved 28 January 1995
Lifesaving
Issued 6 May 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 17 May 1993
Resolved 17 May 1993
Documentation
Issued 16 July 1992 Resolved
PROVIDE COPY OF NEW RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 16 July 1992
Resolved 16 July 1992
Construction/Loadline
Issued 3 March 1992 Resolved
MAKE PERMANENT REPAIR TO WASTED BULKHEAD, ENGINE ROOM FORWARD.
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Electrical
Issued 3 March 1992 Resolved
MAKE CABLE RUNS THROUGH ENGINE ROOM FORWARD BULKHEAD WATERTIGHT.
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Navigation
Issued 3 January 1990 Resolved
MODIFY HAND TILLER TO FIT PRESENT STEERING POST.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Navigation
Issued 3 January 1990 Resolved
PROVIDE PROPER RELIEF VALVE AND IDENTIFICATION OF PRESSURE VESSEL.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Fire Fighting
Issued 3 January 1990 Resolved
PROPERLY INSTALL PORTABLE FIRE EXTINGUISHER BRACKET ABOVE ENGINE COMPARTMENT.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Documentation
Issued 3 January 1990 Resolved
PROVIDE CURRENT COPIES OF 46CFR PARTS 166-199, LIGHT LIST, TIDE AND CURRENTTABLES.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Engineering
Issued 3 January 1990 Resolved
INSTALL PROPER FUEL PIPING IN ENGINE COMPARTMENT.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Electrical
Issued 3 January 1990 Resolved
PROVIDE FOR PROPER INSTALLATION OF ELECTRICAL WIRING.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Construction/Loadline
Issued 3 January 1990 Resolved
PROVIDE CAPTIVE RETENTION (CHAINS) FOR DECK COVERS.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Unknown
Issued 21 April 1987 Resolved
DRYDOCK VESSEL FOR CREDIT (TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR) NOT LATER THAN 22MAY87; OR, SURRENDER THE VESSEL'S CURRENT CERTIFICATE OF INSPECTION TO MARINE SAFETY OFFICE PUGET SOUND.
Condition: Unknown
Due 21 April 1987
Resolved 21 April 1987

Ownership record