MAURY USCG vessel records Sign in
← All vessels

ARCADIA

ARCADIA is a 1994 freight ship. The Coast Guard has recorded 24 inspections since 1996, most recently in January 2011, along with 34 deficiencies and 5 operational controls, 1 with no removal date recorded.

Records from 1996 to 2011. Most recent: inspection, 30 January 2011.

Built
1994
Last inspected
30 January 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

9080182 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
433694
Flag
MARSHALL ISLANDS
—
Maury page id
psix-433694

Inspections, by type

…with no type recorded15
Years with a record 9 calendar years (1996–2011)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it14166 - Convention (Subpart B), Net Ton
25190 - Convention (Subpart B), Gross Ton
41499 - Dead Weight, Ton
50849 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

30 January 2011 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3935870
12 December 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3378809
4 December 2008 Ballast Water Examination · PII Safety Exam · MARPOL Annex V Examination · ISPS I Exam · Deficiency Check · MARPOL Annex I Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3370062
3 December 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3370035
18 June 2008 MARPOL Annex V Examination · PII Safety Exam · MARPOL Annex I Examination · ISPS III Exam · Ballast Water Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3240387
26 January 2008 Deficiency Check · ISPS II Exam · Administrative Inspection
Physical examination · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3133849
25 January 2008 Type not recorded
No type recorded · Maritime Safety & Security Team San Francisco (91105) · Activity 3136490
24 January 2008 Type not recorded
No type recorded · Sector Portland · USCG Northwest District (CGD-NW) · Activity 3136046
21 March 2007 Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2891845
2 November 2004 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2233621
29 October 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2230798
28 October 2004 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2230536
26 October 2004 ISPS II Exam
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2228353
9 February 2004 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2002917
5 February 2004 Annual Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2001101
3 February 2004 MARPOL Annex I Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2003997
22 January 2004 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 2007645
16 May 2001 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 289993
28 February 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 287548
24 March 2000 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 276194
9 July 1998 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 417942
10 September 1997 Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 407639
30 August 1997 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 407504
1 February 1996 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 387060

Deficiency record · 34

Engineering › Steering Gear System › Pump
Issued 18 June 2008 Resolved
Hydraulic fluid is leaking from a faulty O-Ring / Gasket for Emergency Steering Gear Pump #2, leaving a residue and creating a slipping hazard. Make permanent repairs within 30 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 4 December 2008
Resolution: Received a class report satisfying the requirement.
Deck/Cargo › Cargo Heating › General
Issued 18 June 2008 Resolved
Vessel's #5P steam heating line, in way of No. 1 Fire Pump in Engine Room, has steam leak and slight water dripping. Make permanent repairs within 30 days to the satisfaction of Class.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 4 December 2008
Resolution: Received a class report satisying the requirement.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 18 June 2008 Resolved
Provide identification information and placard for Marine Sanitation Device within 30 days to USCG.
Action required: 705 - Other - as specified
Due 18 July 2008
Resolved 4 December 2008
Resolution: PSCO verified the proper placement of a placard.
Engineering › Steering Gear System › Rudder Stock
Issued 21 March 2007 Resolved
Main steering gear and rudder stock was not capable of putting the rudder over from 35 deg. port to 35 deg. starboard. Violation of SOLAS 2004 Chpt II-1 Reg 3.2 Rectify prior to departure to the satisfaction of class.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2007
Resolved 22 March 2007
Resolution: Main steering gear and rudder stock was capable of putting the rudder from 35 deg. to 35 deg. upon return to vessel and re-test of the steering gear system.
Engineering › Steering Gear System › Motor
Issued 21 March 2007 Resolved
Starboard emergency steering control was not working properly in steering gear compartment. Violation of SOLAS 2004 Chapter II-I Reg 29.7.1. Rectify prior to departure to the satisfaction of class
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2007
Resolved 24 March 2007
Resolution: Received class report attesting to the proper operation of the emergency steering gear.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 March 2007 Resolved
Compressed air panel is missing safety shield for wiring harness and cooling fan that is located in the engine room. Violation of SOLAS 2004 Chapter II-I Reg 45.1.3. Rectify prior to departure to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2007
Resolved 22 March 2007
Resolution: Crew placed cover over wiring harness and a vent guard over the fan.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 21 March 2007 Resolved
While conducting the deck walk it was discovered that the hand rail that is near the #2 cargo hold on the starboard side is corroded and wasted beyond normal repair. Violation of ILLC 25.2. Rectify to satisfaction of the Class Surveyour prior to departure.
Action required: 705 - Other - as specified
Due 23 March 2007
Resolved 24 March 2007
Resolution: Received class report attesting to the renewal of the handrails.
Engineering › Sea-water System (primary cooling) › Valve
Issued 21 March 2007 Resolved
Valve that supplies cooling water from sea chest to cooling pumps for generators had excessive leaking causing a possible overheating of generators due to loss of cooling. Violation of SOLAS 2004 Chapter II-I/26.1. Rectify prior to departure to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2007
Resolved 22 March 2007
Resolution: Engineers renewed the packing in the stuffing box and valve is no longer leaking.
Operations/Management › Drills/Instruction › Fire
Issued 21 March 2007 Resolved
02 Fire drills were conducting unsatisfactorily as evidenced by the following: The first drill took over 40 mins and the crew still had not accessed the space the fire was located in. 03 SCBAs were not fully charged and the low oxygen alarm was activated. Drill was stopped at this time. 2nd drill was conducted in the ECR. Crew members that were in the control room failed to evacuate the space.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2007
Resolved 22 March 2007
Resolution: Fire drills were witnessed to the satisfaction of the Coast Guard inspectors.
Operations/Management › Drills/Instruction › Fire
Issued 21 March 2007 Resolved
2nd drill cont'd: Fire fighters did not know how to use tending lines, during the drill 02 SCBAs had low oxygen alarms activate. Drill was stopped at this time. Violation of SOLAS 2004 Chapter II-2 Reg 15.1. Rectify prior to departure to the satisfaction of the Coast Guard.
Action required: 17 - Rectify deficiencies prior to departure
Due 23 March 2007
Resolved 22 March 2007
Resolution: Fire drills were witnessed to the satisfaction of the Coast Guard inspectors.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 March 2007 Resolved
Lighting fixture covers all throughout the engine room were cracked, damaged or missing. Could cause injury to persons or put forth a fire hazard. Violation of SOLAS 2004 Chapter II-I/45.1.3. Rectify within 30 days to the satisfaction of Coast Guard
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 26 January 2008
Resolution: Light fixture covers found to be replaced and satisfactory.
Lifesaving › Launching Appliances › Winch
Issued 21 March 2007 Resolved
While recovering the starboard lifeboat/rescue boat the motor for the winch stopped working and is now not operational. Therefore the rescue boat cannot be recovered within the time frame that is allowed by SOLAS. Violation of SOLAS 2004 CHP III/16.2 & Reg 17.4. Rectify prior to departure to the satisfaction of class.
Action required: 705 - Other - as specified
Due 23 March 2007
Resolved 24 March 2007
Resolution: Received class report attesting to the proper operation of the winch motor
Lifesaving › Launching Appliances › Davit
Issued 21 March 2007 Resolved
While conducting abandon ship drill it was found that the limit switches on the starboard side lifeboat were not operational. Recommend that port and starboard side limit switches be tested for proper operation. Violation of SOLAS 2004 Chp III/16.1. LSA Code 6.1.2.7. Rectify prior to departure to the satisfaction of class.
Action required: 705 - Other - as specified
Due 23 March 2007
Resolved 24 March 2007
Resolution: Received class report stating that the limit switches were replaced and in proper working order.
Deck/Cargo › Cargo Transfer (solid) › General
Issued 21 March 2007 Resolved
During the inspection cargo hold #1 crane hoisting wire parted. Violation of SOLAS 2004 Chapter II-1/26. Rectify within 30 days to the satisfaction of class.
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 24 March 2007
Resolution: Received class report stating that the hoisting wire had been renewed and is in good working order.
Electrical › Electric Supply System (service)
Issued 5 February 2004 Resolved
REPLACE MISSING OUTLETS IN # 3 CRANE AND IN GYMNASIUM.
Condition: Improper/Lack of Maintenance
Due 5 February 2004
Resolved 5 February 2004
Resolution: RCVD CLASS ATTESTATION OF REPAIRS, ATTENDING OCMI ALSO VERIFIED REPAIR.
Engineering › Steering Gear System
Issued 5 February 2004 Resolved
VESSLES STEERING COULD NOT BE ACTUATED FOM BRIDGE IN NON-FOLLOW UP. PROVIDE CLASS ATTESTATION OF PROPER OPERATION OF STEERING SYSTEM ACCORDING TO MANUFACTURERS INSTRUCTIONS. LEGACY COMPONENT DESC: Follow-up Assembly
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2004
Resolution: VESSEL RCVD LOD TO PROCEDE TO PROVIDENCE, RI. TO CONDUCT REPAIRS. RCVD CLASS. ATTEST. OF PROPER OPERATION.
Pollution Prevention/Response › Prevention Equipment
Issued 3 February 2004 Resolved
Oily Water Separator is inoperable. Correct prior to departure from port to the satisfaction of class. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 6 February 2004
Resolution: Lloyds class surveyor attended with CG marine inspector. OWS observed to function properly to class and USCG satisfaction.
Pollution Prevention/Response › Prevention Equipment
Issued 23 January 2004 Resolved
PROPERLY REPAIR OWS AUDIBLE AND VISUAL ALARMS AND PROVIDE CLASS ATTES. OF REPAIRS. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 24 January 2004
Resolved 24 January 2004
Resolution: RCVD CLASS ATTESTATION TO REPAIRS IN ADDTION TO ATTENDING OCMI''S VERIFICATION.
Engineering › Steam System (auxiliary)
Issued 23 January 2004 Resolved
PROPERLY REPAIR MANUALY OPERATED CABLES FOR SAFETY SHUT-OFF VALVES ON BOILER. LEGACY COMPONENT DESC: Valve, Control
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 January 2004
Resolution: RCVD CLASS ATTEST.
Engineering
Issued 23 January 2004 Resolved
REPLACE ALL MISSING GUARDS ON BILGE PUMPS, FIRE PUMPS, BALLAST PUMPS ETC. LEGACY COMPONENT DESC: PUMPS
Condition: Improper/Lack of Maintenance
Due 24 January 2004
Resolved 24 January 2004
Resolution: RCVD CLASS ATTESTATION OF REPAIRS IN ADDITION TO ATTENDING OCMI''''''''''''''''S VERIFICATION.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 23 January 2004 Resolved
PROCEDURES FOR OPERATING FIXED CO2 SYSTEM COULD NOT BE FOLLOWED DUE TO MISLABELED DIAGRAMS. LEGACY COMPONENT DESC: Operating Controls
Condition: Unknown
Due 24 January 2004
Resolved 24 January 2004
Resolution: RCVD CLASS ATTESTATION OF PROPER PROCEDURES IN ADDITION TO ATTENDING OCMI''''S VERIFICATION.
Fire Fighting › Fixed Fire Detection System
Issued 23 January 2004 Resolved
PROVIDE CLASS ATTESTATION OF PROPER OPERATION OF FIRE DETECTION SYSTEM TO INCLUDE PROCEDURES FOR PANEL OPERATION AND PLANNED MAINTENANCE.
Due 24 January 2004
Resolved 24 January 2004
Resolution: RCVD CLASS ATTESTATION OF OPERATING PROCEDURES IN ADDITION TO ATTENDING OCMI''''''''''''''''S VERIFICATION.
Fire Fighting › Structural Fire Protection - General
Issued 23 January 2004 Resolved
NUMEROUS SELF CLOSING DOORS THROUGHOUT HOUSE DID NOT CLOSE AUTOMATICALY. LEGACY COMPONENT DESC: Accommodation Space Protection
Condition: Improper/Lack of Maintenance
Due 24 January 2004
Resolved 24 January 2004
Resolution: RCVD CLASS ATTESTATION OF REPAIRS IN ADDITION TO ATTENDING OCMI''''S VERIFICATION.
Pollution Prevention/Response › Prevention Equipment
Issued 23 January 2004 Resolved
REPAIR NUMEROUS LEAKS THROUGHOUT STEERING SYSTEM, CLEAN EXCESSIVE HYDRUALIC FLUID IN CONTAINMENT AREA OF STEERING SYSTEM AND ON DECK PLATES OF STEERING ROOM. LEGACY COMPONENT DESC: Fixed Containment
Condition: Improper/Lack of Maintenance
Due 24 January 2004
Resolved 24 January 2004
Resolution: RCVD CLASS ATTESTATION OF REPAIRS TO LEAKING STEERING SYSTEM AND REMOVAL OF EXCESSIVE OIL IN CONTAINMENT AREA AND ON DECK PLATING IN ADDTION TO OCMI''''S VERIFICATION.
Construction/Loadline › Penetrations
Issued 23 January 2004 Resolved
ALL WATER/WEATHERTIGHT DOORS THROUGHOUT HOUSE NEEDED ADJUSTMENT TO CLOSE PROPERLY.
Condition: Improper/Lack of Maintenance
Due 24 January 2004
Resolved 24 January 2004
Resolution: RCVD CLASS ATTESTATION TO REPAIRS IN ADDITION TO ATTENDING OCMI''''S VERIFICATION.
Fire Fighting › Miscellaneous Items
Issued 23 January 2004 Resolved
INSPECT AND REPLACE AS NECESSARY, ALL MISSING SPANNER WRENCHES IN FIRESTATIONS THROUGHOUT SHIP.
Condition: Improper/Lack of Maintenance
Due 24 February 2004
Resolved 24 February 2004
Resolution: RCVD CLASS ATTESTATION OF RETURNED SPANNER WRENCHES IN ADDITION TO ATTENDING OCMI''S VERIFICATION.
Engineering › Steam System (auxiliary) › Piping
Issued 23 January 2004 Resolved
EXCESSIVE STEAM LEAK IN PIPING TO HYDRAULIC PURIFIER.
Condition: Unknown
Due 24 January 2004
Resolved 24 January 2004
Resolution: RCVD CLASS ATTESTATION OF REPAIRS IN ADDITION TO ATTENING OCMI''S VERIFICATION.
Engineering
Issued 16 May 2001 Resolved
Make repairs to leaking seal on force fan motor to the satisfaction of Class.
Condition: Unknown
Due 17 May 2001
Resolved 23 May 2001
Lifesaving
Issued 16 May 2001 Resolved
Provide adiquate food rations for Port and Starboard lifeboats. Vessel needs 10 more rations.
Condition: Unknown
Due 17 May 2001
Resolved 23 May 2001
Navigation
Issued 16 May 2001 Resolved
Class society surveyor to attest to the proper repairs of excessive leaks of steering gear system Starboard Ram.
Condition: Unknown
Due 17 May 2001
Resolved 23 May 2001
Engineering
Issued 16 May 2001 Resolved
Make repair to #2 lube oil purifier leak on top of unit.
Condition: Unknown
Due 17 May 2001
Resolved 23 May 2001
Construction/Loadline
Issued 16 May 2001 Resolved
Clean oil puddles throught engine room and generator flat.
Condition: Unknown
Due 17 May 2001
Resolved 23 May 2001
Unknown
Issued 30 August 1997 Resolved
The original brackets used onboard for several portable fire extinguishers have broken and the quick release system therefore does not operate properly. These fire extinguishers are not readily accessible in accordancewith Solas Chapter II-2, Regulation 2.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998
Unknown
Issued 30 August 1997 Resolved
The remote fuel oil shutoff on the emergency generator does not operate properly in accordance with Solas Chapter II-1, Regulation 27.
Condition: Unknown
Due 10 July 1998
Resolved 10 July 1998

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.