Records from 1996 to 2010. Most recent: inspection, 4 October 2010.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
4 October 2010
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3862097
25 July 2005
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2438926
29 August 2003
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1890756
26 August 2003
Administrative Inspection
Administrative · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 1887447
14 January 2003
Deficiency Check
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1730410
24 October 2002
Passenger/Freight Vessel Examination · MARPOL Annex V Examination · MARPOL Annex I Examination
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1696121
28 January 2002
MARPOL Annex I Examination · Annual Inspection
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1476226
7 April 1999
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 427197
21 October 1998
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 421634
23 April 1997
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 403008
23 October 1996
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 396505
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 25 July 2005
No resolution recorded
Vessel did not provide ballast water management plan. Cite: 33 CFR 151.2035(a)7
Condition: Unknown
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Operations/Management › Navigation Safety
Issued 29 August 2003
Resolved
VESSEL'S NAV PUBS AND CHARTS NOT UP TO DATE, LAST NTM WEEK#25, A VIOLATION OF 33 CFR 164.33(a)(1)(ii) and (a)(2). CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Carriage of Charts and Publications
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2003
Resolved 9 September 2003
Resolution: RECEIVED RECEIPT FOR PURCHASE OF NTM(S). DEFICIENCY CLEARED.
Navigation › Piloting/Steering
Issued 29 August 2003
Resolved
VESSEL'S MAGNETIC COMPASS IS OFF 32 DEGREES AS COMPARED TO GYRO COMPASS, A VIOLATION OF 33 CFR 164.35. CORRECT PRIOR TO DEPARTURE. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 29 August 2003
Resolved 9 September 2003
Resolution: RECEIVED TECH REPORT ATTESTING TO THE SATISFACTORY CALIBRATION OF VESSEL''S MAGNETIC COMPASS. DEFICIENCY CLEARED.
Fire Fighting › Portable Foam Applicators
Issued 24 October 2002
Resolved
Several portable foam extinguishers had cracked hoses.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 24 October 2002
Resolved 14 January 2003
Resolution: Hoses replaced.
Fire Fighting › Structural - B Class Divisions
Issued 24 October 2002
Resolved
The two service window doors from the crew's mess to the pantry and the doors from the crew's mess to the passageway do not meet the same fire integity requirements as the bulkheads (B-0). LEGACY COMPONENT DESC: Openings - Doors
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Due 24 October 2002
Resolved 14 January 2003
Resolution: Service windows sealed, water curtain tested. FCP approved by class
Navigation › Emergency Steering
Issued 24 October 2002
Resolved
Emergency steering room was missing non-slip surface and handrails.
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 24 October 2002
Resolved 14 January 2003
Resolution: Non_slip surface and handrails installed.
Electrical › Lighting (service)
Issued 28 January 2002
Resolved
Provide protective covers for all fluorescent lighting fixtures throughout machinery spaces
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Due 28 February 2002
Resolved 14 January 2003
Resolution: Light covers installed.
Documentation
Issued 7 April 1999
Resolved
Provide Certificate of Competency for all officers.
Condition: Unknown
Due 21 November 2000
Resolved 21 November 2000
Deck/Cargo
Issued 21 October 1998
Resolved
REMOVE PAINT FROM SPARE STORE ROOM #140 OR INSTALL A FIRE EXTINGUISHER OUTSIDE ROOM, REMOVE OBSOLETE ELECTRICAL HEATER, AND MAKE VAPOR PRROF LIGHTFIXTURE IN ROOM.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Lifesaving
Issued 21 October 1998
Resolved
CLASS SOCIETY TO PROVIDE EVIDENCE THAT DISTRESS SIGNALS ARE SOLAS APPROVED.
Condition: Unknown
Due 9 April 1999
Resolved 9 April 1999