Professional
The full record for this vessel
Behind this panel: 5 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; 1 operational control with no removal date recorded; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 5 June 2020
Resolved
Before ship leaves port and at all times during the voyage, all life-saving appliances shall be in working order and ready for immediate use. 03 food rations found to be in bad condition leaving the ship short of amount of rations required per capacity of crew for lifeboat. 74Solas(2014) Ch III/reg 20.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2020
Resolution: Vessel Recieved Rations to satisfy the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 June 2020
Resolved
The requirements for tankers in SOLAS Ch II-2 shall apply to ships covered by the code, irrespective of tonnage, in addition, two fire-fighters outfits shall be provided. 02 fire-fighters outfit jackets found in a state of disrepair. Both are missing buttons posing as a fire hazard. 74SOLAS(2014)CH10.2.3 IBC Code CH.11.1.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2020
Resolution: Vessel recieved new fire suits to satisfy the requirement.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 31 January 2020
Resolved
Door required to-closing shall not be fitted with hold-backs hoods. Door leading to the bridge and two door in the galley were fitted with hold back hooks posing as a fire and smoke hazard to the ship and crew.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 June 2020
Resolution: Class Report
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 31 January 2020
Resolved
Where “A” class divisions are penetrated for passage of electric cable pipes trucks, ducts, etc. arrangements shall be made to ensure that the fire resistance is not impaired. 02 penetrations within main vertical zone for electric cable found not sealed properly thus impairing fire resistance door also observed not self closing
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 June 2020
Resolution: Class Report
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 January 2020
Resolved
After any survey of the ship under regulation 10 has been completed, no changes shall be made in the structural arrangements, machinery, equipment and other items covered by the survey without the sanction of the administration 02 doors in galley storage are found with frozen emergency escape mechanism
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 5 June 2020
Resolution: PSC A in Charleston
Lifesaving › Lifeboat Equipment › Food Ration
Issued 25 May 2016
Resolved
Food rations shall be kept in airtight packaging and be stowed in a watertight container. PSCO observed 05 rations out of 25 in the free fall lifeboat that did not have an airtight seal.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 May 2016
Resolved 28 May 2016
Resolution: Vessel provide invoice from Olympic Gulf Ship Services, Inc stating 5 packs of food rations were delivered to the vessel.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 25 May 2016
Resolved
The date when musters are held, details of abandon ship drills, and fire drills shall be recorded in a log book as may be prescribed by the Administration. PSCO observed that fire and abandon ship drills were not recorded for the month of March 2016.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: Vessel provided digital copy of log for drills conducted in March 2016.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 May 2016
Resolved
The company should ensure that the policy is implemented and maintained at all levels of the organization, both ship based and shore based. Crew admitted to disposing expired medicine overboard which is in contradiction to the listed SMS procedures.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 May 2016
Resolved 5 June 2020
Resolution: PSC A exam in Charleston
Documentation › Logs/Records › Garbage Recordkeeping
Issued 25 May 2016
Resolved
Each discharge operation or completed incineration shall be recorded in the Garbage Record Book. PSCO observed that expired medicines were not being recorded when removed from the ship IAW with ships Garbage Management Plan.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 25 May 2016
Resolved 5 June 2020
Resolution: PSC A in Charleston
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 25 May 2016
Resolved
The vessel operator of each vessel required by 33CFR 155.720 to have transfer procedures shall maintain them current and shall require vessel personnel to use the transfer procedures for each transfer operation. PSCO observed ship's crew not utilizing transfer procedures as required.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: Vessel provided oil transfer procedures, and continued to bunker using them.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 25 May 2016
Resolved
Each loading arm and each transfer pipe system must not leak under static liquid pressure at least 1.5 times MAWP. Crew could not provide yearly testing records.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 25 May 2016
Resolution: Crew pressure tested piping during USCG visit.