Records from 1996 to 2005. Most recent: inspection, 5 October 2005.
Inspection history · 24
5 October 2005
PII Safety Exam · MARPOL Annex I Examination · Deficiency Check · ISPS III Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2507856
19 August 2005
ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · COC-TVE Annual
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2467104
21 January 2005
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2278976
20 July 2004
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2139072
7 July 2004
COC-TVE Renew
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2118964
2 July 2004
ISPS II Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2118602
23 September 2003
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1911123
24 September 2002
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1679780
6 July 2002
Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1643873
5 March 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 134484
18 February 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 286853
7 August 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 280722
20 March 2000
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 275952
22 February 2000
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 274766
28 January 2000
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 494445
8 November 1999
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 434286
17 February 1999
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 481827
6 February 1998
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 525468
28 October 1997
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 409436
7 January 1997
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 506799
30 December 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 710344
24 November 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 107742
20 June 1996
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 393391
28 January 1996
Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 387172
Deck/Cargo › Cargo Heating › General
Issued 19 August 2005
Resolved
CARGO STEAM LINE BETWEEN #4 AND #5 CARGO HOLDS HAS A PINHOLE LEAK.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Resolution: During the course of the deck inspection, the boarding team noted that the deficiency had been rectified.
Lifesaving › Lifeboat Equipment
Issued 23 September 2003
Resolved
18 food ration seals were compromised. LEGACY COMPONENT DESC: Food Ration
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2003
Resolved 25 September 2003
Electrical › Electrical Distribution System (service)
Issued 6 July 2002
Resolved
all 3 emergency shutdowns were rewired by ships electrician, and were not wired properly to meet class 1 division 1 wiring standards according to nec code LEGACY COMPONENT DESC: Switch
Condition: Improper Installation
Due 6 July 2002
Resolved 24 September 2002
Resolution: Repairs were made to all emergency shutdowns, IAW the code.
Deck/Cargo › Inert Gas System
Issued 6 July 2002
Resolved
IGS soot blower interlock was inop. and needs to be operable according to solas 74/83ch II-2 REG 62.5 LEGACY COMPONENT DESC: soot blower interlock
Condition: Improper/Lack of Maintenance
Due 6 July 2002
Resolved 17 July 2002
Electrical
Issued 18 February 2001
Resolved
PROVE PROPER OPERATION OF THE AUTOMATIC START-UP FUNCTION OF THE EMERGENCY GENERATOR TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO DEPARTURE.
Condition: Unknown
Due 18 February 2001
Resolved 13 March 2001
Construction/Loadline
Issued 18 February 2001
Resolved
PROVE PROPER OPERATION OF THE STBD BILGE PUMP ALARM IN THE PUMPROOM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, PRIOR TO DEPARTURE FROM MOBMS.
Condition: Unknown
Due 18 February 2001
Resolved 13 March 2001
Deck/Cargo
Issued 22 February 2000
Resolved
PROVIDE CLASS SOCIETY ATTESTATION ADDRESSING REPAIR TO FRACTURE IN #3 PORT BOUBLE BOTTOM TANK IN WAY OF #4 CENTER TANK LOCATED ALONG THE 10TH LONGITUDINAL.
Condition: Unknown
Due 1 June 2000
Resolved 26 May 2000
Construction/Loadline
Issued 22 February 2000
Resolved
REPAINT VESSEL'S NAME ON PORT & STARBOARD SIDE HULL.
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000
Fire Fighting
Issued 22 February 2000
Resolved
RENEW RELIEF VALVE PIPING FOR CO2 SYSTEM.
Condition: Unknown
Due 4 August 2000
Resolved 28 August 2000