MAURY USCG vessel records Sign in
← All vessels

GOTLAND SPIRIT

GOTLAND SPIRIT is a 1995 tank ship. The Coast Guard has recorded 24 inspections since 1996, most recently in October 2005, along with 9 deficiencies and 1 operational control.

Records from 1996 to 2005. Most recent: inspection, 5 October 2005.

Built
1995
Last inspected
5 October 2005
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9077331 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
433737
Flag
LIBERIA
—
Maury page id
psix-433737

Inspections, by type

…with no type recorded17
Years with a record 10 calendar years (1996–2005)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 21 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it28319 - Convention (Subpart B), Net Ton
52875 - Convention (Subpart B), Gross Ton
95371 - Dead Weight, Ton
111900 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 6

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

KIRBY 14825 B Tank Barge · MISLE 40781 · 5 March 2001 · activity 134484MST 285 Freight Barge · MISLE 92794 · 5 March 2001 · activity 134484GINNY STONE Towing Vessel · MISLE 129697 · 5 March 2001 · activity 134484SUSAN JOHNSON Towing Vessel · MISLE 138476 · 5 March 2001 · activity 134484DONAU Tank Ship · MISLE 252065 · 5 March 2001 · activity 134484CH 9377 Freight Barge · MISLE 391352 · 5 March 2001 · activity 134484

Inspection history · 24

5 October 2005 PII Safety Exam · MARPOL Annex I Examination · Deficiency Check · ISPS III Exam · MARPOL Annex V Examination · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2507856
19 August 2005 ISPS II Exam · MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · COC-TVE Annual
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2467104
21 January 2005 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2278976
20 July 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2139072
7 July 2004 COC-TVE Renew
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2118964
2 July 2004 ISPS II Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2118602
23 September 2003 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1911123
24 September 2002 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1679780
6 July 2002 Certificate of Compliance
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1643873
5 March 2001 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 134484
18 February 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 286853
7 August 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 280722
20 March 2000 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 275952
22 February 2000 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 274766
28 January 2000 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 494445
8 November 1999 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 434286
17 February 1999 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 481827
6 February 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 525468
28 October 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 409436
7 January 1997 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 506799
30 December 1996 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 710344
24 November 1996 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 107742
20 June 1996 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 393391
28 January 1996 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 387172

Deficiency record · 9

Deck/Cargo › Cargo Heating › General
Issued 19 August 2005 Resolved
CARGO STEAM LINE BETWEEN #4 AND #5 CARGO HOLDS HAS A PINHOLE LEAK.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 September 2005
Resolved 5 October 2005
Resolution: During the course of the deck inspection, the boarding team noted that the deficiency had been rectified.
Lifesaving › Lifeboat Equipment
Issued 23 September 2003 Resolved
18 food ration seals were compromised. LEGACY COMPONENT DESC: Food Ration
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 September 2003
Resolved 25 September 2003
Electrical › Electrical Distribution System (service)
Issued 6 July 2002 Resolved
all 3 emergency shutdowns were rewired by ships electrician, and were not wired properly to meet class 1 division 1 wiring standards according to nec code LEGACY COMPONENT DESC: Switch
Condition: Improper Installation
Due 6 July 2002
Resolved 24 September 2002
Resolution: Repairs were made to all emergency shutdowns, IAW the code.
Deck/Cargo › Inert Gas System
Issued 6 July 2002 Resolved
IGS soot blower interlock was inop. and needs to be operable according to solas 74/83ch II-2 REG 62.5 LEGACY COMPONENT DESC: soot blower interlock
Condition: Improper/Lack of Maintenance
Due 6 July 2002
Resolved 17 July 2002
Electrical
Issued 18 February 2001 Resolved
PROVE PROPER OPERATION OF THE AUTOMATIC START-UP FUNCTION OF THE EMERGENCY GENERATOR TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO DEPARTURE.
Condition: Unknown
Due 18 February 2001
Resolved 13 March 2001
Construction/Loadline
Issued 18 February 2001 Resolved
PROVE PROPER OPERATION OF THE STBD BILGE PUMP ALARM IN THE PUMPROOM TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR, PRIOR TO DEPARTURE FROM MOBMS.
Condition: Unknown
Due 18 February 2001
Resolved 13 March 2001
Deck/Cargo
Issued 22 February 2000 Resolved
PROVIDE CLASS SOCIETY ATTESTATION ADDRESSING REPAIR TO FRACTURE IN #3 PORT BOUBLE BOTTOM TANK IN WAY OF #4 CENTER TANK LOCATED ALONG THE 10TH LONGITUDINAL.
Condition: Unknown
Due 1 June 2000
Resolved 26 May 2000
Construction/Loadline
Issued 22 February 2000 Resolved
REPAINT VESSEL'S NAME ON PORT & STARBOARD SIDE HULL.
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000
Fire Fighting
Issued 22 February 2000 Resolved
RENEW RELIEF VALVE PIPING FOR CO2 SYSTEM.
Condition: Unknown
Due 4 August 2000
Resolved 28 August 2000

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.