A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 29 July 2009
Resolved
Found 2nd fire suit incapable of protecting the wearer from burns and scalding by steam, and direct violation of fire suit requirements listed in FSS CODE and SOLAS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2009
Resolution: Vessel ordered and received new SOLAS approved fire suite.
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle, Spare
Issued 29 July 2009
Resolved
Found SCBA with only 01 air cylinder for its type, making the vessel incapable of properly combating a fire and in direct violation with the requirements of 2 spare charges per SCBA in FSS CODE and SOLAS.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2009
Resolution: Vessel now has 2 spare charges per SCBA.
Personnel › Certificates/Documents/Licenses › License, Chief Mate
Issued 29 July 2009
Resolved
Found Fist Deck Officer Dianfu Geng with China Coastal Limitation on flag state endorsement certificate, making license invalid beyond Chinese Coastal Waters. M/V Win Shing does not meet the safe manning requirements listed in ships safe manning document and is in direct violation of STCW 95.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2009
Resolution: Received new license from flag state without limitations.
Personnel › Certificates/Documents/Licenses › License, Second Assistant Engineer
Issued 29 July 2009
Resolved
Found 2nd Engineer with expired license and flag state endorsement. Now M/V WIn Shing does not meet safe manning requirements listed in safe manning document and is in direct violation of STCW 95.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2009
Resolution: Received new license from flag state.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 29 July 2009
Resolved
Excessive oil discovered in engine room bilges, posing a fire hazard.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2009
Resolution: Bilge is now free of oil and no longer posses a fire hazard.
Electrical › Electric Generation Source (emergency) › Generator
Issued 29 July 2009
Resolved
Found Emergency Generator incapable of primary or secondary start, this places the vessel with no capability to provide emergency power. M/V Win Shing does not have a functioning self contained source of emergency power and is in direct violation of SOLAS 60.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2009
Resolution: Vessel conducted successful primary and secondary start of emergency generator.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 29 July 2009
Resolved
Found numerous exposed moving machinery in engine romm creating a hazardous condition for crew members. This personnel harzadous conditon is in direct violation with SOLAS.
Condition: Improper Installation
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2022
Resolution: Vessel was discovered during a data pull for old open deficiencies. Although the vessel is still listed as active in MISLE, multiple sources consistently state that the vessel was scrapped in 2014, rendering any open deficiencies moot.
Engineering › Fuel Oil Service System › Valve, Control
Issued 29 July 2009
Resolved
Found that Emergency Generator did not have a fuel shut off outside of space.
Condition: Placed in Improper Service
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2022
Resolution: Vessel was discovered during a data pull for old open deficiencies. Although the vessel is still listed as active in MISLE, multiple sources consistently state that the vessel was scrapped in 2014, rendering any open deficiencies moot.
Navigation › Voyage Data Recorder › Simplified Voyage Data Recorder (SVDR)
Issued 2 July 2008
Resolved
Recorder displaying system failure
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2022
Resolution: Vessel was discovered during a data pull for old open deficiencies. Although the vessel is still listed as active in MISLE, multiple sources consistently state that the vessel was scrapped in 2014, rendering any open deficiencies moot.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 2 July 2008
Resolved
Several lifejackets with inoperable PFD lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2008
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 2 July 2008
Resolved
Life jacket in crew state room is inadequate. Vest is not designed for continuous flotation.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2008
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 2 July 2008
Resolved
Found rigged lighting in crew state room with exposed wiring.
Action required: 15 - Rectify deficiencies by next port
Resolved 1 April 2022
Resolution: Vessel was discovered during a data pull for old open deficiencies. Although the vessel is still listed as active in MISLE, multiple sources consistently state that the vessel was scrapped in 2014, rendering any open deficiencies moot.
Engineering › Compressed Air System (control) › Compressor
Issued 2 July 2008
Resolved
Compressor pump with exposed moving equipment without machinery cover.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 July 2008
Lifesaving › Immersion Suits › Serviceable
Issued 2 July 2008
Resolved
Found zippers on immersion suits requiring significant strength to zip and unzip suit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2008
Engineering › Steering Gear System › Follow-up Assembly
Issued 2 July 2008
Resolved
Found non follow up steering mode drifting 5 degrees past release of non follow up.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2022
Resolution: Vessel was discovered during a data pull for old open deficiencies. Although the vessel is still listed as active in MISLE, multiple sources consistently state that the vessel was scrapped in 2014, rendering any open deficiencies moot.
Communications › Visual Communication › Signalling Lamp
Issued 2 July 2008
Resolved
Found signaling lamp inoperable.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 July 2008
Lifesaving › Lifeboat Equipment › Radio Antenna
Issued 2 July 2008
Resolved
Found 01 lifeboat portable radio antennae cracked.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 3 July 2008
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 2 July 2008
Resolved
Found exposed wiring in vegetable reefer storage.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2022
Resolution: Vessel was discovered during a data pull for old open deficiencies. Although the vessel is still listed as active in MISLE, multiple sources consistently state that the vessel was scrapped in 2014, rendering any open deficiencies moot.
Electrical › Electric Generation Source (emergency) › Generator
Issued 2 July 2008
Resolved
Found emergency generator room missing cover for fixed louvers.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2022
Resolution: Vessel was discovered during a data pull for old open deficiencies. Although the vessel is still listed as active in MISLE, multiple sources consistently state that the vessel was scrapped in 2014, rendering any open deficiencies moot.
Construction/Loadline › Structures › Superstructure
Issued 2 July 2008
Resolved
Found wasted area starboard side bulkhead revealing 3" hole to emergency generator room.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 1 April 2022
Resolution: Vessel was discovered during a data pull for old open deficiencies. Although the vessel is still listed as active in MISLE, multiple sources consistently state that the vessel was scrapped in 2014, rendering any open deficiencies moot.
Fire Fighting › Fixed Deck Foam System › Piping
Issued 2 July 2008
Resolved
Found fire main piping port side amidships with 1" fracture. Fracture can progress making vessel incapable to combat a fire.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 July 2008
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 25 January 2005
Resolved
Remove oily water form forepeak tank and clean tank for ballast water only.
--Vessel originally constructed to carry fuel oil in forepeak tank (grand fathered under 33 CFR 155.470) however, tank was found being used to hold engine room oily bilge wastes.
Action required: 15 - Rectify deficiencies by next port
Resolved 9 August 2006
Fire Fighting › Grease Extraction Hood › General
Issued 25 January 2005
Resolved
Clean galley vent located above wok. Remove all built up grease.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 January 2005
Resolved
Properly support wires located behind electrical distribution panel located in engine control room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 January 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 25 January 2005
Resolved
Install protective cage around bare light bulb located in lower engine room near oil water separator.
Action required: 15 - Rectify deficiencies by next port
Resolved 26 January 2005