← All vessels
STELLER
Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG Southeast District (CGD-SE) · Other hulls named STELLER
STELLER is a 1995 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 1995, most recently in October 2025, along with 44 deficiencies and 1 operational control.
Records from 1995 to 2025. Most recent: inspection, 9 October 2025.
- Built
- 1995
- Last inspected
- 9 October 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 44 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
N/A
433842
Flag
UNITED STATES
—
Maury page id
psix-433842
Inspections, by type
…with no type recorded3
Years with a record
25 calendar years (1995–2025)
The 33 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Gross Ton
4 - Regulatory (Subpart C or D), Net Ton
4 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 33
9 October 2025
Deficiency Check · Administrative Inspection · Drydock Exam · COI Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8250103
31 March 2025
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8102777
21 November 2024
Annual Inspection · Deficiency Check · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8020512
6 December 2023
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7827348
3 November 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7580525
3 November 2021
Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7336907
9 October 2020
COI Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7079767
8 October 2020
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7074146
26 November 2019
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6854161
16 October 2018
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6547624
4 October 2017
Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6281184
30 September 2016
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5995668
30 September 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6013969
28 September 2015
COI Inspection · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5726521
16 October 2014
DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5005701
28 September 2011
Hull Examination · Construction Oversight · Plan Review "T" Boat · Deadweight Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4151847
27 September 2011
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4154624
14 February 2011
Type not recorded
No type recorded · Marine Safety Center (MSC) · Activity 3983588
3 February 2011
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3938548
27 January 2011
Administrative Inspection · In-Service Inspection · Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3935068
27 September 2010
COI Inspection · Hull Examination · DAPI Audit · Drydock Exam · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3858150
26 September 2008
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3352135
2 October 2007
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3071823
17 October 2006
COI Inspection · Hull Examination · Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2803504
2 August 2005
Hull Examination · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2473061
11 February 2003
Annual Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1741251
6 November 2001
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1412389
21 October 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 791677
15 October 1999
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1440207
3 November 1998
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1442801
20 November 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1390656
20 December 1996
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1414729
2 November 1995
Initial Certification · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1189400
Deficiency record · 44
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 November 2025
Resolved
At least one ring life buoy must be fitted with a lifeline. Each lifeline on a ring life buoy must: (5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds). MI observed lifeline on ring life buoy was deteriorated and snapped when slight force was applied. Replace lifeline and provide photograph evidence of rectification.
46 CFR 180.70(c) / 16c
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 October 2025
Resolved
A vessel must undergo an inspection for certification as specified in 176.404 and They must submit a written application for renewal of a Certificate of Inspection to the OCMI at least 30 days prior to the expiration date of the Certificate of Inspection. Vessel was due for COI renewal inspection on 9OCT25 and has yet to submit an application for inspection, nor receive a COI inspection. Vessel shall not operate with passengers until new COI has been issued.
46CFR176.500(b)
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 21 November 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. MI identified multiple detached deck support structural members near the bow and stern of the vessel.
46 CFR 177.100
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 November 2024
Resolved
Gauges to indicate engine revolutions per minute (RPM), jacket water discharge temperature, and lubricating oil pressure must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. MI identified that the gauge for RPMs was inoperable.
46 CFR 182.410(b)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 6 December 2023
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible.
Vessel did not have chart/map of operating area onboard.
46 CFR 184.420(a)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 December 2023
Resolved
The number and identification of life jackets stowed, and their sizes, must be marked in clearly legible letters and numbers on each container/stowage location.
Labels for adult life jacket stowage markings were broken an illegible.
46 CFR 185.604(f)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 November 2022
Resolved
An adult life jacket must be provided for each person carried aboard a vessel.
Vessel is short 03 adult life jackets for what it's certificated to carry (22).
Reduce passenger count to 19 persons until outfitted with complete number of life jackets.
46 CFR 180.71(a)
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 November 2022
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
MI identified the fuel shutoff quick release was not labeled.
46 CFR 185.608
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 3 November 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible.
MI identified that the vessel was missing charts for its area of operation.
46 CFR 184.420
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 November 2022
Resolved
Each vessel must be equipped with at least two operable portable battery lights.
MI identified that the portable lights onboard would not power on.
46 CFR 183.430
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 3 November 2021
Resolved
Electrical equipment exposed to the weather must be watertight.
Light above operating station missing protective cover.
46 CFR 183.210(b)
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 3 November 2021
Resolved
A ship, except a ship of less than 26 feet in length, must have a placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space.
Vessel did not have a placard onboard.
33 CFR 155.450(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 November 2021
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
02 adult life jackets were found not in a serviceable condition.
46 CFR 180.71(a)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 October 2020
Resolved
46 CFR 176.600 (c)(2) - A vessel that is exposed to salt water not more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural examination at least once every five years. Vessel did not conduct a scheduled dry dock prior to September 30, 2020.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 October 2018
Resolved
Vessel's ring buoy is unserviceable. Replace ring buoy with an approved one meeting 46CFR60.050.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 October 2018
Resolved
Provide first aid kit approved under 46CFR160.041 or a kit with equivalent contents and instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 16 October 2018
Resolved
Provide a portable watertight container marked as required by 46CFR185.614 for distress flares
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 16 October 2018
Resolved
Provide placard containing instructions for the donning and use of the lifejackets onboard.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 16 October 2018
Resolved
commence logging emergency drills including man-overboard and fire fighting
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 16 October 2018
Resolved
Three life jackets found unserviceable. Replace life jackets with approved ones.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 October 2018
Resolved
Repair crack weld on ladder stb side deck mount.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 16 October 2017
Resolved
Missing Emergency Instructions
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 16 October 2017
Resolved
Provide one additional B-I fire extinguisher
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 30 September 2016
Resolved
Install retro reflective tape on life ring IAW 46CFR185.604
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 30 September 2016
Resolved
Install Child Life Jacket placard noting storage location IAW 46CFR180.78a5.
Construction/Loadline › Structures › Deck Plating
Issued 30 September 2016
Resolved
Provide repair proposal for cracked structural supports on forward deck and make approved repairs to satisfaction of attending [name withheld] 46CFR176.802
Construction/Loadline › Hull › Weld
Issued 27 September 2011
Resolved
Make repairs to cracked welds on ladder to the satisfaction of attending MI.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 27 September 2010
Resolved
Provide proof of active employee assistance program.
Construction/Loadline › Hull › Weld
Issued 17 October 2006
Resolved
Make repairs to aft end of stbd pontoon.
Construction/Loadline › Hull › Weld
Issued 17 October 2006
Resolved
Drain water from aft port pontoon and find leak.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 17 October 2006
Resolved
Renew/ service B-II fire extinguisher.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 24 August 2005
Resolved
Provide proof of proper masters liscences for two operators. Both licenses must be shown to have been upgraded to inspected vessels.
Construction/Loadline › Hull › Hull Plating
Issued 24 August 2005
Resolved
Repair Aluminum Hull as marked by Marine Inspector.
Lifesaving › Lifejacket/PFD (General)
Issued 11 February 2003
Resolved
16 LIFE JACKETS WERE FOUND TO HAVE WASTED/DAMAGED RETROREFLECTIVE TAPE LEGACY COMPONENT DESC: Retroreflective Material
Lifesaving › Lifejacket/PFD (General)
Issued 11 February 2003
Resolved
2 LIFEJACKETS WERE FOUND TO BE HARDENED/FROZEN AND WERE REJECTED. OWNER INSTRUCTED TO REPLACE LEGACY COMPONENT DESC: Condition
Lifesaving › Lifebuoys
Issued 11 February 2003
Resolved
WATERLIGHT FOUND ON LIFE BUOY FOUND TO BE NON-CG APPROVED. OWNER INSTRUCTED TO REPLACE LIGHT WITH CG APPROVED LIGHT. VESSEL WAS RESTRICTED TO DAYLIGHT OPERATIONS UNTIL LIGHT WAS REPLACED. LEGACY COMPONENT DESC: Self-igniting Lights
Lifesaving
Issued 3 November 1998
Resolved
INSTALL RETROREFLECTIVE TAPE ON RING BUOY.
Fire Fighting
Issued 3 November 1998
Resolved
PROVIDE THREE 2 1/2 GALLON BUCKETS MARKED "FIRE FIGHTING BUCKET"
Engineering
Issued 3 November 1998
Resolved
REPLACE FUEL TANK HOLD DOWN CLIP.
Lifesaving
Issued 3 November 1998
Resolved
PROVIDE EMERGENCY LIGHT.
Navigation
Issued 3 November 1998
Resolved
REPLACE GREEN RUNNING LIGHT.
Lifesaving
Issued 3 November 1998
Resolved
PROVIDE ONE CHILD SIZE LIFE PRESERVER WITH THE PROPER MARKINGS.
Navigation
Issued 3 November 1998
Resolved
REPLACE COVER FOR WHITE LIGHT.
Fire Fighting
Issued 3 November 1998
Resolved
PROVIDE PROOF OF INSPECTION OF FIRE EXTINGUISHERS
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.