11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 June 2025
Resolved
Secured to the vessel by a painter with a float-free link permanently attached to the vessel.
Attach painter to vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2025
Resolution: Painter was reattached to vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2025
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2025
Resolution: Approved first aid kit was purchased and placed on board.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 June 2025
Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Holes in forward engine room bulkhead allow fixed fire extinguishing medium to communicate through bulkhead.
Make vapor tight to ensure quantity of extinguisher is sufficient.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 July 2025
Resolution: Holes in bulkhead were filled with fire block foam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2025
Resolved
Battery installations must be mounted 46 CFR 183.350 to protect against shifting of the vessel and free from exposure to water splash or spray.
Mount Vessel's battery box.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 July 2025
Resolution: battery box mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2025
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018.
Reapply Retro to life rings.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 July 2025
Resolution: retro reflective tape was placed on ring buoy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 June 2025
Resolved
On a vessel on an exposed or partially protected route, a watertight coaming with a height of at least 150
millimeters (6 inches) must be provided under each weathertight door in a cockpit or a well, or on the main deck of a flush deck vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2025
Resolution: Plan for 6" coaming was approved and installed at door for main entry.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 2 December 2024
Resolved
Found damage to fiberglass and keel on vessel. Vessel is to go on the blocks in an arrangement that allows for inspection of the damaged areas and a full dry dock exam and internal structural exam must be completed prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 December 2024
Resolution: Obsereved Keel- POC prepped, cleaned, and glassed. all SAT
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 November 2024
Resolved
After a report from another operator, it was discovered that the port side had an inset, approximately 2x2 foot that was caved inward approximately 3-4 inches. Submit a repair proposal for permanent repairs. 46CFR176.600 (d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 December 2024
Resolution: Repair completed satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 November 2024
Resolved
Vessel failed to report the vessels damage which is considered a marine casualty as it materially and adversely affected the vessels seaworthiness or fitness for service or route.
46CFR185.202
Action required: 10 - Deficiency Rectified
Resolved 27 November 2024
Resolution: Corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 November 2024
Resolved
Observed hull damage portside below rail gate entry and three feet above the waterline. Vessel is authorized temporary repairs. CG inspector is to observe crop out (cut-out to good wood), prior to final repairs. Vessel is restricted to operate in the bay and permanent repairs are to be completed no later than 04DEC2024.
Action required: 705 - Other - as specified
Due 4 December 2024
Resolved 2 December 2024
Resolution: Reissued, see MISLE 8040848
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 February 2024
Resolved
Aft engine support bracket found to be wasted. Replace in kind or submit repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 March 2024
Resolution: Replaced in kind
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 July 2023
Resolved
Vessel only has 03 red hand flares and 03 orange smoke flares. Acquire additional flares until the vessel has a total of 06 red hand flares and 06 orange smoke. Vessel is restricted to a Lakes, Bays, and Sounds route until deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 16 September 2023
Resolution: Vessel sent in pictures of newly acquired flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 July 2023
Resolved
Vessel's steering system hydraulic reservoir in the engine room was leaking excessively. Identify and repair the source of the leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2023
Resolution: Vessel repaired leak.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 July 2023
Resolved
Vessel completed dry dock and has not completed IFR / Egress modifications or drills. Vessel is prohibited from carrying overnight passengers or allowing passengers in the bunk rooms until modifications are made and an egress drill is completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2025
Resolved 19 January 2025
Resolution: Modifications complete, Drills Complete. IFR Complete.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 April 2023
Resolved
Vessels on an Ocean/Coastwise route are required to have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel is restricted from carrying passengers until fire detection system has been installed to the satisfaction of the USCG OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2023
Resolution: Witnessed operation of engineroom, berthing / main salon, & operating station smoke detection unit; ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 7 April 2023
Resolved
Vessels that carry overnight passengers are required to have monitoring devices to ensure the wakefulness of the watchmen as required by 46 CFR 185.410(a). Vessel is restricted from conducting voyages exceeding twelve (12) hours until an approved overnight watch system has been installed. Restricted to less than 12 hour voyages until installed.
Action required: 705 - Other - as specified
Resolved 1 June 2023
Resolution: Witnessed satisfactory test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 September 2021
Resolved
Shaft seal is leaking significantly. Properly adjust/repair shaft seal as necessary to control leaking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2021
Resolved 16 March 2022
Resolution: Received video of the shafts running with accceptable levels of dripping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2021
Resolved
Properly secure/mount fish hold pump in the lazzarrette.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2021
Resolved 16 March 2022
Resolution: Received pictures of the new mounting.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 20 September 2021
Resolved
A section of the MDE serpentine belt is missing a section of guard plates. Install additional guards for MDE serpentine belt to protect against rotating machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2021
Resolved 16 March 2022
Resolution: Received pictures of the new protective covering.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 September 2021
Resolved
Vessel's alcohol test strips were expired. Provide up to date alcohol test strips.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 20 September 2021
Resolution: Deficiency rectified on-the-spot. Vessel POC acquired additional alcohol test strips from SAC.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2020
Resolved
Remove or install dead end wiring into J-box in forward engine room space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 11 August 2020
Resolution: Operator provided picture of cleaned up wiring.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 July 2020
Resolved
Make forward engine room bulkhead vapor tight and water tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 11 August 2020
Resolution: Operator provided pictures of sealing forward engine room bulkhead.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 July 2020
Resolved
Repair leak on hydraulic pump on main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Marine inspector visually inspected and deemed SAT on def check.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2020
Resolved
Properly secure starboard wash down pump in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Visually inspected and pump was secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2020
Resolved
Properly secure starboard battery boxes in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 11 August 2020
Resolution: Operator provided picture of new brackets securing battery boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2020
Resolved
Properly install electrical cover on fish hold refrigeration unit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Visually inspected that electrical cover was installed.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 July 2020
Resolved
Repair rotten port side deck supports in accommodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Visually inspected repair of rotten deck supports on def check.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 July 2020
Resolved
Install emergency lighting to forward escape hatch in accommodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 11 August 2020
Resolution: Operator provided pictures of installed e-lights.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 July 2020
Resolved
Properly tighten all fuel hose end-fittings/connections throughout fuel system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Visually inspected that all fuel hose end-fittings/connections throughout fuel system were tightened.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 7 July 2020
Resolved
Securely fasten reduction gear actuating cable bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Visually inspected that reduction gear actuating cable bracket was fastened.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 July 2020
Resolved
Provide generator with means of cooling which operates whenever the engine is running.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 24 August 2020
Resolution: Bait well is SAT for means of cooling generator due to gen not supplying power to any Vital systems onboard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 July 2020
Resolved
Provide information of size of pre-engineered Fire Boy cylinder, date it was installed, and type of agent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 11 August 2020
Resolution: Operator provided requested information of size, date, and type opf agent.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 July 2020
Resolved
Provide measurements of engine room compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 11 August 2020
Resolution: Operator provided measurements of engine room.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 July 2020
Resolved
Complete chemical testing program compliance audit. Provide pre-employment testing and drug testing background check records for new employee Haylee Treviranus. Provide pre-employment testing records for Epking Liu.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 20 August 2020
Resolution: conducted DAPI audit with vessel operator and verified employee records.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2020
Resolved
Complete FCC Safety Radio Certificate inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 27 August 2020
Resolution: Vessel operator provided picutres of completed FCC Safety Radio Certificate inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2020
Resolved
Provide up-to-date excerpts from U.S. Coast Pilot and USCG Light List for areas of operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 27 August 2020
Resolution: Vessel operator provided picutres of USCG Light List.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 July 2020
Resolved
Properly input new MMSI number and GPS input into VHF-DSC radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 20 August 2020
Resolution: Confirmed vessel operator input new MMSI number and GPS input into VHF-DSC radio on def check.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 7 July 2020
Resolved
Provide metal waste receptacles inside accommodation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2020
Resolved 20 August 2020
Resolution: Visually inspected new metal waste receptacles inside accommodation.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 7 July 2020
Resolved
Install illuminated mag compass at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 11 August 2020
Resolution: Operator provided picture of illuminated mag compass.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 June 2020
Resolved
Due to circumstances arising as a result of COVID-19, the COI Inspection for the vessel, originally due on June 16, 2020, has been deferred for 90 days. The circumstances which necessitate this deferment are beyond the control of the Master. The vessel must complete the required COI Inspection prior to September 16, 2020. If circumstances necessitating this deferment remain after this 90-day period, you must submit a request to extend this deferment. This deferral is only valid for the above-mentioned inspection. This CG-835V shall be maintained aboard the vessel until the required inspections have been completed.
Action required: 705 - Other - as specified
Due 16 September 2020
Resolved 7 July 2020
Resolution: COI inspection completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 January 2020
Resolved
Loose bulwarks/railing starboard side where gate is located. Make bulwarks/railing stable and able to hold 200lbs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 21 January 2020
Resolved
Connect fuel vent port side fuel tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
46 CFR 177.202(b)(4)
Action required: 705 - Other - as specified
Due 3 January 2020
Resolved 20 September 2021
Resolution: Completed satisfactory on-site verification of the submitted A/C 1-line diagram. A copy of the "Examined" diagram is stored in the local OCMI vessel files.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2019
Resolved
All escape hatches and emergency exits used as means of escape must be marked on both sides in clearly legible letters that says "EMERGENCY EXIT, KEEP CLEAR". Emergency exit hatch from accommodation space was not marked on the top side in the galley. Mark emergency escape hatch with proper marking on both sides.
46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 9 January 2020
Resolution: Exit sign installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 2 October 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
Action required: 10 - Deficiency Rectified
Resolved 2 October 2019
Resolution: Educated operator.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2019
Resolved
The means of escape must be sufficient for rapid evacuation in an emergency for the number of persons served. Egress hindered due to not enough step points being in place. Provide additional steps in way of emergency escape to make egress sufficiently rapid on forward emergency escape.
46 CFR 177.500
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 July 2020
Resolution: Inspected by attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 October 2019
Resolved
Vessel under 65 ft and has no fixed firefighting system in compliance with NFPA 96. Provide UL approved fire detector in galley in vicinity of cooking area.
Sector San [name withheld] Policy Letter #20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 9 January 2020
Resolution: Detector installed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 2 October 2019
Resolved
Hydrostatic release did not have dates marked. Provide documentation of when hydrostatic release was installed and mark expiration date on hydrostatic release from two years of installation.
46 CFR 185.740(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 July 2020
Resolution: Inspected by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
All electrical equipment and circuits must be clearly marked and identified. Right side of main distribution panel did not have markings identifying circuit. Mark right hand side of panel with proper circuit.
46 CFR 183.220(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2020
Resolution: All circuits labeled.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 July 2019
Resolved
Provide repair plan for damaged bow to Coast Guard Marine Inspector for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 July 2019
Resolved
Repair/replace faulty cooling water pump for main diesel engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 June 2019
Resolved
Provide life jacket donning placard for each style of life jacket on board the vsl.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 12 June 2019
Resolved
Provide approved alcohol test devise/strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 8 July 2019
05 - Radio Communications › N/A - No Subsystem › INMARSAT ship earth station
Issued 12 June 2019
Resolved
Ensure the vsl INMARSAT is listed on the radiotelephony safety certificate or install a MF radio and recertify the installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2019
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 7 June 2018
Resolved
Install MF/HF radio or equivalent. Prior to sailing farther than 20NM from land
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 14 August 2018
Resolution: Sat phone onboard and tested.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 June 2018
Resolved
Provide up to date charts for operating area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: New charts provided
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 June 2018
Resolved
Provide current light list, coast pilot and tide tables or excerpts of these Pubs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: New publications provided
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 June 2018
Resolved
Provide a wire splint fot the medical first aid kit
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: Wire splint provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2018
Resolved
Submit Drug and Alcohol MIS report for the reporting period of 2017
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: Drug and alcohol report provided
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 June 2018
Resolved
Ensure wiring is properly installed and hung for bunk house bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: Wiring properly installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 June 2018
Resolved
Wire all bilge pump operating controls to one centeral location point to include operating indicating lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2018
Resolution: Bilge operating controls and light in one central point
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Guards - fencing around dangerous machinery parts
Issued 7 June 2018
Resolved
Install belt pulley guards on generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: Guard installed
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 7 June 2018
Resolved
Permanently/properly install bilge alarm indicating pannel located at the bridge control station.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2018
Resolution: Bilge alarm indicating pannel installed on bridge.
Construction/Loadline › Hull › Keel
Issued 29 January 2018
Resolved
When vessel was placed on blocks keel crushed frame. Keel showed signs of damage as well.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 13 February 2018
Resolution: 2 sections of crushed keel were repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 29 January 2018
Resolved
Remove rotted tranverse fram in aft engine room.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 13 February 2018
Resolution: Rotten tranverse frame in aft engine room was repaired.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 29 January 2018
Resolved
Gen mount rusted and wood rotted. Replace with new mounts.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 13 February 2018
Resolution: Generator mount corrosion and rotten wood repaired.
Engineering › Bilge Water Management System › Pump
Issued 8 May 2017
Resolved
Make fast/secure installed Bilge pumps and install hose claps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Engineering › Steering Gear System › Linkage
Issued 8 May 2017
Resolved
Prove operation of Emergency Steering to the satisfaction of attending Coast Guard Marine Inspector; Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 May 2017
Resolved
Complete a satisfactory Drug and Alcohol Program Audit. Specific items of concern: Pre-employment and random test records,Employee Assistance Program requirements, general record keeping. Complete prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2017
Resolved
Reinstall/attach bonding wires generator space. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2017
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 8 May 2017
Resolved
Install flame screen on STBD fuel vent goose neck. Insure screens meet 46CFR182.450
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 May 2017
Resolved
Reinstall emergency lighting in Accommodation/bunk room. Prior to carrying overnight passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2017
Resolved 12 July 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 May 2017
Resolved
Remove or properly install open J-box located IVO STBD generator forward BLKHD. Currently the J-box has no cover and has exposed wires. If wires are not being used, remove the dead-end wires.
Due 8 June 2017
Resolved 12 July 2017
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 8 May 2017
Resolved
Several electrical control and breaker boxes were noted severally corroded and positioned as to allow water intrusion from above. replace boxes as needed and either relocate as to not allow water intrusion or provided drip shields.
Due 8 June 2017
Resolved 12 July 2017
Navigation › Piloting/Steering › Magnetic Compass
Issued 8 May 2017
Resolved
Provide working compass light/illumination.
Due 8 June 2017
Resolved 12 July 2017
Navigation › Piloting/Steering › Marine Charts
Issued 8 May 2017
Resolved
Provide up to date charts or print out pertinent Local Notice to Mariners for area of operation.
Due 8 June 2017
Resolved 12 July 2017
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 8 May 2017
Resolved
Provide waste management plan.
Due 8 June 2017
Resolved 12 July 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 May 2017
Resolved
Medical/first aid kit; provide wire splint and ammonia inhalant.
Due 8 June 2017
Resolved 12 July 2017
Electrical › Electric Generation Source (service) › Conductor
Issued 8 May 2017
Resolved
Move/relocate and properly secure generator gauge wire cluster that is currently resting on generator.
Due 8 June 2017
Resolved 12 July 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2017
Resolved
Bridge wiring; remove dead-end/non-functioning wires and properly secure throughout the bridge.
Due 8 June 2017
Resolved 12 July 2017