ALICIA

ALICIA is a 1957 passenger vessel (inspected). The Coast Guard has recorded 97 inspections since 1984, most recently in November 2025, along with 185 deficiencies and 3 casualty investigations between 2007 and 2025.

Records from 1984 to 2025. Most recent: inspection, 3 November 2025.

Built
1957
Last inspected
3 November 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG4438
Flag
UNITED STATES
368160170
Maury page id
psix-43390

Inspections, by type

…with no type recorded20
Years with a record 38 calendar years (1984–2025)
The 97 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)42.8 ft × 14.6 ft × 4.6 ft
Registered tonnagegross 22 / net 15
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · VENICE, CA, UNITED STATES · built 1957
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 21 July 2025 · expires 31 July 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it22 - Regulatory (Subpart C or D), Gross Ton
15 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDL7429MMSI 368160170 · active · compulsorily equipped · granted 28 August 2020, expires 28 August 2030
WDG4438MMSI 367536570 · expired · compulsorily equipped · granted 22 June 2012, cancelled 27 August 2022
WCZ9247MMSI not assigned · expired · compulsorily equipped · granted 30 June 2000, cancelled 4 September 2010
WCZ4855MMSI not assigned · expired · compulsorily equipped · granted 7 September 1999, cancelled 7 November 2009
WCW8026MMSI not assigned · expired · voluntarily equipped · granted 8 August 1996, cancelled 14 October 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

AFRA LAUREL Tank Ship · MISLE 642311 · 11 July 2007 · activity 2997526USS SQUALL (PC 7) Public Vessel, Unclassified · MISLE 456909 · 12 June 2001 · activity 11635

Inspection history · 97

3 November 2025 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8262734
3 November 2025 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8263959
24 June 2025 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8166374
27 November 2024 Damage Survey · Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8040848
19 November 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8037308
3 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8014043
1 July 2024 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7946795
21 February 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7868133
5 July 2023 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7733513
5 July 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7774429
7 April 2023 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7664835
20 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7383058
20 September 2021 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7313175
7 July 2020 DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6990211
3 June 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6966988
9 April 2020 Construction Oversight · Administrative Inspection · Plan Review "T" Boat
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6945871
21 January 2020 Deficiency Check · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6892967
2 October 2019 Deficiency Check · In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6826831
3 July 2019 Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6735041
2 July 2019 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6782617
12 June 2019 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6711192
7 June 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6429543
29 January 2018 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6345850
7 April 2017 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6117860
20 June 2016 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5913107
20 January 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5800271
25 June 2012 DAPI Audit · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4345218
7 December 2011 Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4186486
17 December 2009 Internal Structural Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3651805
4 June 2008 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3208551
18 January 2008 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3130760
11 July 2007 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2997526
13 June 2007 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2954109
29 June 2006 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2681902
9 June 2006 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2673094
18 October 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2516906
7 July 2005 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2415760
18 June 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2425349
22 June 2004 Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2098078
1 March 2004 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2015782
25 June 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1826799
26 June 2002 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1636314
21 May 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1619004
7 February 2002 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1484890
3 July 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 61363
28 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 66126
28 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1395767
12 June 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 11635
5 June 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1418913
25 February 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1408815
22 August 2000 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 220936
15 June 2000 COI Inspection · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1418704
8 February 2000 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1046500
26 May 1999 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 801652
7 April 1999 Re-Inspection · Drydock Extension
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1372573
14 September 1998 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 799642
2 June 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1471831
9 April 1998 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1122877
3 April 1998 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1122682
21 May 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1378060
7 April 1997 COI Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1390491
25 February 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1406055
23 July 1996 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1087222
25 June 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1394562
10 April 1996 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1355785
1 May 1995 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1360115
8 February 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1443542
24 May 1994 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 859969
25 April 1994 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 857904
13 April 1994 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1389800
10 June 1993 Hull Examination · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1132518
18 May 1992 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1254757
5 May 1992 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1257408
8 April 1992 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1261687
28 February 1992 Damage Survey
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1362608
31 January 1992 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 144661
25 November 1991 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 942870
17 May 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1222350
30 April 1991 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1233481
9 April 1991 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 900878
9 April 1991 Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 900879
30 April 1990 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 921090
20 April 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1218159
30 October 1989 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 898580
1 May 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 887972
12 April 1989 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1208798
21 November 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 893693
20 April 1988 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1342597
17 February 1988 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1328317
29 December 1987 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1008074
28 April 1987 Re-Inspection · Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1005350
30 December 1986 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1309577
10 November 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1325977
21 April 1986 Deficiency Check · Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 999272
7 January 1986 Credit Drydock
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 990917
24 April 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 981132
28 December 1984 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 976254

Deficiency record · 185

11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 24 June 2025 Resolved
Secured to the vessel by a painter with a float-free link permanently attached to the vessel. Attach painter to vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2025
Resolution: Painter was reattached to vessel.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 June 2025 Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2025
Resolution: Approved first aid kit was purchased and placed on board.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 24 June 2025 Resolved
A pre-engineered fixed gas fire extinguishing system must: Be installed in accordance with the manufacturer's instructions. Holes in forward engine room bulkhead allow fixed fire extinguishing medium to communicate through bulkhead. Make vapor tight to ensure quantity of extinguisher is sufficient.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 July 2025
Resolution: Holes in bulkhead were filled with fire block foam.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 June 2025 Resolved
Battery installations must be mounted 46 CFR 183.350 to protect against shifting of the vessel and free from exposure to water splash or spray. Mount Vessel's battery box.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 July 2025
Resolution: battery box mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 June 2025 Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018. Reapply Retro to life rings.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 July 2025
Resolution: retro reflective tape was placed on ring buoy.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 24 June 2025 Resolved
On a vessel on an exposed or partially protected route, a watertight coaming with a height of at least 150 millimeters (6 inches) must be provided under each weathertight door in a cockpit or a well, or on the main deck of a flush deck vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 July 2025
Resolution: Plan for 6" coaming was approved and installed at door for main entry.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 2 December 2024 Resolved
Found damage to fiberglass and keel on vessel. Vessel is to go on the blocks in an arrangement that allows for inspection of the damaged areas and a full dry dock exam and internal structural exam must be completed prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 December 2024
Resolution: Obsereved Keel- POC prepped, cleaned, and glassed. all SAT
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 November 2024 Resolved
After a report from another operator, it was discovered that the port side had an inset, approximately 2x2 foot that was caved inward approximately 3-4 inches. Submit a repair proposal for permanent repairs. 46CFR176.600 (d)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 9 December 2024
Resolution: Repair completed satisfactorily.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 November 2024 Resolved
Vessel failed to report the vessels damage which is considered a marine casualty as it materially and adversely affected the vessels seaworthiness or fitness for service or route. 46CFR185.202
Action required: 10 - Deficiency Rectified
Resolved 27 November 2024
Resolution: Corrected on the spot.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 19 November 2024 Resolved
Observed hull damage portside below rail gate entry and three feet above the waterline. Vessel is authorized temporary repairs. CG inspector is to observe crop out (cut-out to good wood), prior to final repairs. Vessel is restricted to operate in the bay and permanent repairs are to be completed no later than 04DEC2024.
Action required: 705 - Other - as specified
Due 4 December 2024
Resolved 2 December 2024
Resolution: Reissued, see MISLE 8040848
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 21 February 2024 Resolved
Aft engine support bracket found to be wasted. Replace in kind or submit repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 1 March 2024
Resolution: Replaced in kind
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 July 2023 Resolved
Vessel only has 03 red hand flares and 03 orange smoke flares. Acquire additional flares until the vessel has a total of 06 red hand flares and 06 orange smoke. Vessel is restricted to a Lakes, Bays, and Sounds route until deficiency is rectified.
Action required: 705 - Other - as specified
Resolved 16 September 2023
Resolution: Vessel sent in pictures of newly acquired flares.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 July 2023 Resolved
Vessel's steering system hydraulic reservoir in the engine room was leaking excessively. Identify and repair the source of the leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 16 September 2023
Resolution: Vessel repaired leak.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 July 2023 Resolved
Vessel completed dry dock and has not completed IFR / Egress modifications or drills. Vessel is prohibited from carrying overnight passengers or allowing passengers in the bunk rooms until modifications are made and an egress drill is completed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 March 2025
Resolved 19 January 2025
Resolution: Modifications complete, Drills Complete. IFR Complete.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 7 April 2023 Resolved
Vessels on an Ocean/Coastwise route are required to have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel is restricted from carrying passengers until fire detection system has been installed to the satisfaction of the USCG OCMI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 April 2023
Resolution: Witnessed operation of engineroom, berthing / main salon, & operating station smoke detection unit; ALL SAT.
07 - Fire Safety › N/A - No Subsystem › Crew alarm
Issued 7 April 2023 Resolved
Vessels that carry overnight passengers are required to have monitoring devices to ensure the wakefulness of the watchmen as required by 46 CFR 185.410(a). Vessel is restricted from conducting voyages exceeding twelve (12) hours until an approved overnight watch system has been installed. Restricted to less than 12 hour voyages until installed.
Action required: 705 - Other - as specified
Resolved 1 June 2023
Resolution: Witnessed satisfactory test.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 September 2021 Resolved
Shaft seal is leaking significantly. Properly adjust/repair shaft seal as necessary to control leaking.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2021
Resolved 16 March 2022
Resolution: Received video of the shafts running with accceptable levels of dripping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 September 2021 Resolved
Properly secure/mount fish hold pump in the lazzarrette.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2021
Resolved 16 March 2022
Resolution: Received pictures of the new mounting.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 20 September 2021 Resolved
A section of the MDE serpentine belt is missing a section of guard plates. Install additional guards for MDE serpentine belt to protect against rotating machinery.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 October 2021
Resolved 16 March 2022
Resolution: Received pictures of the new protective covering.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 September 2021 Resolved
Vessel's alcohol test strips were expired. Provide up to date alcohol test strips.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 20 September 2021
Resolution: Deficiency rectified on-the-spot. Vessel POC acquired additional alcohol test strips from SAC.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2020 Resolved
Remove or install dead end wiring into J-box in forward engine room space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 11 August 2020
Resolution: Operator provided picture of cleaned up wiring.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 7 July 2020 Resolved
Make forward engine room bulkhead vapor tight and water tight.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 11 August 2020
Resolution: Operator provided pictures of sealing forward engine room bulkhead.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 7 July 2020 Resolved
Repair leak on hydraulic pump on main engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Marine inspector visually inspected and deemed SAT on def check.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2020 Resolved
Properly secure starboard wash down pump in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Visually inspected and pump was secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2020 Resolved
Properly secure starboard battery boxes in engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 11 August 2020
Resolution: Operator provided picture of new brackets securing battery boxes.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 July 2020 Resolved
Properly install electrical cover on fish hold refrigeration unit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Visually inspected that electrical cover was installed.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 7 July 2020 Resolved
Repair rotten port side deck supports in accommodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Visually inspected repair of rotten deck supports on def check.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 7 July 2020 Resolved
Install emergency lighting to forward escape hatch in accommodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 11 August 2020
Resolution: Operator provided pictures of installed e-lights.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 July 2020 Resolved
Properly tighten all fuel hose end-fittings/connections throughout fuel system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Visually inspected that all fuel hose end-fittings/connections throughout fuel system were tightened.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 7 July 2020 Resolved
Securely fasten reduction gear actuating cable bracket.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 20 August 2020
Resolution: Visually inspected that reduction gear actuating cable bracket was fastened.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 7 July 2020 Resolved
Provide generator with means of cooling which operates whenever the engine is running.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 August 2020
Resolved 24 August 2020
Resolution: Bait well is SAT for means of cooling generator due to gen not supplying power to any Vital systems onboard.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 7 July 2020 Resolved
Provide information of size of pre-engineered Fire Boy cylinder, date it was installed, and type of agent.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 11 August 2020
Resolution: Operator provided requested information of size, date, and type opf agent.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 7 July 2020 Resolved
Provide measurements of engine room compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 11 August 2020
Resolution: Operator provided measurements of engine room.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 July 2020 Resolved
Complete chemical testing program compliance audit. Provide pre-employment testing and drug testing background check records for new employee Haylee Treviranus. Provide pre-employment testing records for Epking Liu.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 20 August 2020
Resolution: conducted DAPI audit with vessel operator and verified employee records.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2020 Resolved
Complete FCC Safety Radio Certificate inspection.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 27 August 2020
Resolution: Vessel operator provided picutres of completed FCC Safety Radio Certificate inspection.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 7 July 2020 Resolved
Provide up-to-date excerpts from U.S. Coast Pilot and USCG Light List for areas of operations.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 27 August 2020
Resolution: Vessel operator provided picutres of USCG Light List.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 July 2020 Resolved
Properly input new MMSI number and GPS input into VHF-DSC radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 20 August 2020
Resolution: Confirmed vessel operator input new MMSI number and GPS input into VHF-DSC radio on def check.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 7 July 2020 Resolved
Provide metal waste receptacles inside accommodation.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 July 2020
Resolved 20 August 2020
Resolution: Visually inspected new metal waste receptacles inside accommodation.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 7 July 2020 Resolved
Install illuminated mag compass at operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2020
Resolved 11 August 2020
Resolution: Operator provided picture of illuminated mag compass.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 June 2020 Resolved
Due to circumstances arising as a result of COVID-19, the COI Inspection for the vessel, originally due on June 16, 2020, has been deferred for 90 days. The circumstances which necessitate this deferment are beyond the control of the Master. The vessel must complete the required COI Inspection prior to September 16, 2020. If circumstances necessitating this deferment remain after this 90-day period, you must submit a request to extend this deferment. This deferral is only valid for the above-mentioned inspection. This CG-835V shall be maintained aboard the vessel until the required inspections have been completed.
Action required: 705 - Other - as specified
Due 16 September 2020
Resolved 7 July 2020
Resolution: COI inspection completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 21 January 2020 Resolved
Loose bulwarks/railing starboard side where gate is located. Make bulwarks/railing stable and able to hold 200lbs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 21 January 2020 Resolved
Connect fuel vent port side fuel tank.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 March 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019 Resolved
Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps. 46 CFR 177.202(b)(4)
Action required: 705 - Other - as specified
Due 3 January 2020
Resolved 20 September 2021
Resolution: Completed satisfactory on-site verification of the submitted A/C 1-line diagram. A copy of the "Examined" diagram is stored in the local OCMI vessel files.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2019 Resolved
All escape hatches and emergency exits used as means of escape must be marked on both sides in clearly legible letters that says "EMERGENCY EXIT, KEEP CLEAR". Emergency exit hatch from accommodation space was not marked on the top side in the galley. Mark emergency escape hatch with proper marking on both sides. 46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 9 January 2020
Resolution: Exit sign installed.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 2 October 2019 Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously.
Action required: 10 - Deficiency Rectified
Resolved 2 October 2019
Resolution: Educated operator.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2019 Resolved
The means of escape must be sufficient for rapid evacuation in an emergency for the number of persons served. Egress hindered due to not enough step points being in place. Provide additional steps in way of emergency escape to make egress sufficiently rapid on forward emergency escape. 46 CFR 177.500
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 July 2020
Resolution: Inspected by attending MI.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 2 October 2019 Resolved
Vessel under 65 ft and has no fixed firefighting system in compliance with NFPA 96. Provide UL approved fire detector in galley in vicinity of cooking area. Sector San [name withheld] Policy Letter #20
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 November 2019
Resolved 9 January 2020
Resolution: Detector installed.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 2 October 2019 Resolved
Hydrostatic release did not have dates marked. Provide documentation of when hydrostatic release was installed and mark expiration date on hydrostatic release from two years of installation. 46 CFR 185.740(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 July 2020
Resolution: Inspected by attending MI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019 Resolved
All electrical equipment and circuits must be clearly marked and identified. Right side of main distribution panel did not have markings identifying circuit. Mark right hand side of panel with proper circuit. 46 CFR 183.220(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 January 2020
Resolution: All circuits labeled.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 July 2019 Resolved
Provide repair plan for damaged bow to Coast Guard Marine Inspector for approval.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 August 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 3 July 2019 Resolved
Repair/replace faulty cooling water pump for main diesel engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 12 June 2019 Resolved
Provide life jacket donning placard for each style of life jacket on board the vsl.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2019
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 12 June 2019 Resolved
Provide approved alcohol test devise/strips.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 July 2019
Resolved 8 July 2019
05 - Radio Communications › N/A - No Subsystem › INMARSAT ship earth station
Issued 12 June 2019 Resolved
Ensure the vsl INMARSAT is listed on the radiotelephony safety certificate or install a MF radio and recertify the installation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 8 July 2019
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 7 June 2018 Resolved
Install MF/HF radio or equivalent. Prior to sailing farther than 20NM from land
Action required: 705 - Other - as specified
Due 6 July 2018
Resolved 14 August 2018
Resolution: Sat phone onboard and tested.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 7 June 2018 Resolved
Provide up to date charts for operating area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: New charts provided
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 7 June 2018 Resolved
Provide current light list, coast pilot and tide tables or excerpts of these Pubs.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: New publications provided
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 June 2018 Resolved
Provide a wire splint fot the medical first aid kit
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: Wire splint provided
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 June 2018 Resolved
Submit Drug and Alcohol MIS report for the reporting period of 2017
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: Drug and alcohol report provided
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 7 June 2018 Resolved
Ensure wiring is properly installed and hung for bunk house bilge pump.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: Wiring properly installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 June 2018 Resolved
Wire all bilge pump operating controls to one centeral location point to include operating indicating lights.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2018
Resolution: Bilge operating controls and light in one central point
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Guards - fencing around dangerous machinery parts
Issued 7 June 2018 Resolved
Install belt pulley guards on generator.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 14 August 2018
Resolution: Guard installed
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 7 June 2018 Resolved
Permanently/properly install bilge alarm indicating pannel located at the bridge control station.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 14 August 2018
Resolution: Bilge alarm indicating pannel installed on bridge.
Construction/Loadline › Hull › Keel
Issued 29 January 2018 Resolved
When vessel was placed on blocks keel crushed frame. Keel showed signs of damage as well.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 13 February 2018
Resolution: 2 sections of crushed keel were repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 29 January 2018 Resolved
Remove rotted tranverse fram in aft engine room.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 13 February 2018
Resolution: Rotten tranverse frame in aft engine room was repaired.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 29 January 2018 Resolved
Gen mount rusted and wood rotted. Replace with new mounts.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 13 February 2018
Resolution: Generator mount corrosion and rotten wood repaired.
Engineering › Bilge Water Management System › Pump
Issued 8 May 2017 Resolved
Make fast/secure installed Bilge pumps and install hose claps.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Engineering › Steering Gear System › Linkage
Issued 8 May 2017 Resolved
Prove operation of Emergency Steering to the satisfaction of attending Coast Guard Marine Inspector; Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 May 2017 Resolved
Complete a satisfactory Drug and Alcohol Program Audit. Specific items of concern: Pre-employment and random test records,Employee Assistance Program requirements, general record keeping. Complete prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2017 Resolved
Reinstall/attach bonding wires generator space. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2017
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 8 May 2017 Resolved
Install flame screen on STBD fuel vent goose neck. Insure screens meet 46CFR182.450
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2017
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 8 May 2017 Resolved
Reinstall emergency lighting in Accommodation/bunk room. Prior to carrying overnight passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 June 2017
Resolved 12 July 2017
Electrical › Electrical Distribution System (service) › Junction Box
Issued 8 May 2017 Resolved
Remove or properly install open J-box located IVO STBD generator forward BLKHD. Currently the J-box has no cover and has exposed wires. If wires are not being used, remove the dead-end wires.
Due 8 June 2017
Resolved 12 July 2017
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 8 May 2017 Resolved
Several electrical control and breaker boxes were noted severally corroded and positioned as to allow water intrusion from above. replace boxes as needed and either relocate as to not allow water intrusion or provided drip shields.
Due 8 June 2017
Resolved 12 July 2017
Navigation › Piloting/Steering › Magnetic Compass
Issued 8 May 2017 Resolved
Provide working compass light/illumination.
Due 8 June 2017
Resolved 12 July 2017
Navigation › Piloting/Steering › Marine Charts
Issued 8 May 2017 Resolved
Provide up to date charts or print out pertinent Local Notice to Mariners for area of operation.
Due 8 June 2017
Resolved 12 July 2017
Documentation › Safety/Response Plans/Programs › Waste Management Plan
Issued 8 May 2017 Resolved
Provide waste management plan.
Due 8 June 2017
Resolved 12 July 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 May 2017 Resolved
Medical/first aid kit; provide wire splint and ammonia inhalant.
Due 8 June 2017
Resolved 12 July 2017
Electrical › Electric Generation Source (service) › Conductor
Issued 8 May 2017 Resolved
Move/relocate and properly secure generator gauge wire cluster that is currently resting on generator.
Due 8 June 2017
Resolved 12 July 2017
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 May 2017 Resolved
Bridge wiring; remove dead-end/non-functioning wires and properly secure throughout the bridge.
Due 8 June 2017
Resolved 12 July 2017
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 15 June 2012 Resolved
Hose clamp for cooling water hose to main engine loose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2012
Resolved 25 June 2012
Resolution: Corrected prior to departing vessel.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 15 June 2012 Resolved
Missing 01 child size lifejacket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 June 2012
Resolved 25 June 2012
Documentation › Logs/Records › Drug Test Records
Issued 4 June 2008 Resolved
Provide updated random drug testing crew list to include Hubert Bean and Joey Beard.
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 5 June 2008
Documentation › Certificates/Documents › FCC SSL
Issued 4 June 2008 Resolved
Provide current FCC Safety Radiotelephony Certificate.
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 5 June 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 June 2008 Resolved
Properly label PFD stowage with number of adult/child PFDs stowed inside.
Action required: 705 - Other - as specified
Due 11 June 2008
Resolved 5 June 2008
Fire Fighting › Grease Extraction Hood › General
Issued 13 June 2007 Resolved
Vsl has 6 months to comply
Action required: 705 - Other - as specified
Due 13 December 2007
Resolved 14 June 2007
Resolution: Vsl comply with policy.
Navigation › Collision/Grounding Avoidance › Radar
Issued 13 June 2007 Resolved
Repair or remove radar
Action required: 705 - Other - as specified
Resolved 14 June 2007
Resolution: Radar was repaired.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 13 June 2007 Resolved
Renew smoke detector
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2007
Resolution: Smoke detectors were renewed.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 13 June 2007 Resolved
Lock over board valve
Action required: 705 - Other - as specified
Resolved 14 June 2007
Resolution: Valve was locked.
Engineering › Steering Gear System › Ram
Issued 29 June 2006 Resolved
Re-new and block steering gear ram to provide proper support that prevents excessive strain on longitudinal frame. Provide bushing to prevent excessive movement between ram and rudder arm when steering is actuated.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 7 July 2006
Resolved 11 July 2006
Electrical › Electric Supply System (service) › Cable
Issued 7 July 2005 Resolved
Found cable to light in head penetrating bulkhead, spliced on galley side, and plugged into 110 V outlet in galley. Required to replace/remove wiring & install properly IAW 46CFR183.10-20 (Old T-existing vsl).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2005
Resolved 8 July 2005
Resolution: Operator removed light & wiring.
Navigation › Piloting/Steering › Marine Charts
Issued 7 July 2005 Resolved
Provide currently correct chart for areas to be transitted IAW 46CFR184.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2005
Resolved 8 July 2005
Lifesaving › Inflatable Liferafts › Markings
Issued 7 July 2005 Resolved
Found no instructions launching instructions on-board posted IAW 46CFR185.518.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2005
Resolved 8 July 2005
Electrical › Electric Supply System (service) › Cable
Issued 7 July 2005 Resolved
Found dead-end wires in engine/generator space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2005
Resolved 8 July 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 7 July 2005 Resolved
Found light cover in pilothouse cracked. Replace it.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 August 2005
Resolved 8 July 2005
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 7 July 2005 Resolved
Found fuel tank vent had improper type and size of flame screen installed. Required operator provide 30 x 30 mesh screen IAW 46 CFR 182.450(e).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 July 2005
Resolved 17 October 2005
Documentation › Certificates/Documents › Certificate of Inspection
Issued 5 July 2005 Resolved
Vessel failed to have a valid COI on-board IAW 46CFR176.100(a). Found vessel COI had expired on 15JUN05; evidence indicated vessel operated 05 times w/ expired COI. Vessel required to complete satisfactory inspection for certification IAW 46 CFR 176.404 prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2005
Resolved 7 July 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 22 June 2004 Resolved
Replace outlet box in generator room IAW 183.200(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 22 June 2004
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 22 June 2004 Resolved
Replace muffler hose on generator IAW 176.800
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 22 June 2004
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 22 June 2004 Resolved
Stencil life jacket location in galley IAW 180.78
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2004
Resolved 22 June 2004
Electrical
Issued 25 June 2003 Resolved
Provide metallic wire ties to wire runs in machinery spaces.
Due 25 June 2003
Resolved 1 July 2003
Lifesaving › Inflatable Liferafts
Issued 26 June 2002 Resolved
Provide servicing for life raft. LEGACY COMPONENT DESC: Servicing
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2002
Engineering › Diesel Engine (propulsion-direct drive)
Issued 26 June 2002 Resolved
Replace salt water hose on generator to muffler. LEGACY COMPONENT DESC: Piping
Due 25 June 2003
Resolved 25 June 2003
Resolution: Cleared previously but never cleared from MISLE
Electrical › Electric Supply System (service)
Issued 26 June 2002 Resolved
Install a cover on the 110v recptical in galley. LEGACY COMPONENT DESC: Receptical
Due 25 July 2003
Resolved 25 July 2003
Resolution: Cleared previously but never cleared from MISLE
Electrical › Electric Supply System (service)
Issued 26 June 2002 Resolved
Remove or use dead-ended wires in engine room. LEGACY COMPONENT DESC: Wiring
Due 25 July 2003
Resolved 25 July 2003
Resolution: Cleared previously but never cleared from MISLE
Lifesaving
Issued 28 June 2001 Resolved
Provide proper separation of child and adult life jackets.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Navigation
Issued 28 June 2001 Resolved
Provide proper repairs and proof of repairs of steering system.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Construction/Loadline
Issued 28 June 2001 Resolved
Repair aft bilge alarm.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Documentation
Issued 28 June 2001 Resolved
Post COI in oplain view of passengers.
Condition: Unknown
Due 29 June 2001
Resolved 29 June 2001
Electrical
Issued 5 June 2001 Resolved
Mark generator circuit breaker panel.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Construction/Loadline
Issued 5 June 2001 Resolved
Double clamp hose in generator space on through hole fitting.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 5 June 2001 Resolved
Provide hydrostatic release for IBA & attach sea painter prior to carrying passengers.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Accommodation/Occupational Safety
Issued 5 June 2001 Resolved
Mount access ladder in berthing area.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Fire Fighting
Issued 5 June 2001 Resolved
Provide smoke detectors IAW 46 CFR 181.600.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Electrical
Issued 5 June 2001 Resolved
Secure cover for sonar control box.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 5 June 2001 Resolved
Mark forward escape hatch "Emergency Exit Do Not Block".
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Construction/Loadline
Issued 5 June 2001 Resolved
Provide proper metallic bulkhead penetrations with metallic valves for PVC piping.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 5 June 2001 Resolved
Provide landyard for bell.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 5 June 2001 Resolved
Provide contents for first aid kit IAW with Coast Guard approved list.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Lifesaving
Issued 5 June 2001 Resolved
Provide horn IAW 72 Col Regs. Annex III 2(b).
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Fire Fighting
Issued 5 June 2001 Resolved
Provide screens (30x30) for fuel vents.
Condition: Unknown
Due 5 June 2001
Resolved 5 June 2001
Documentation
Issued 7 April 1999 Resolved
Provide Vessel Documentation.
Condition: Unknown
Due 25 April 1999
Resolved 23 April 1999
Documentation
Issued 7 April 1999 Resolved
Provide master's license.
Condition: Unknown
Due 25 April 1999
Resolved 23 April 1999
Navigation
Issued 7 April 1999 Resolved
Provide Properly Working GPS For Vessel.
Condition: Unknown
Due 25 April 1999
Resolved 27 May 1999
Navigation
Issued 7 April 1999 Resolved
Provide Up To Date Tide and Current Tables For 1999.
Condition: Unknown
Due 25 April 1999
Resolved 23 April 1999
Electrical
Issued 7 April 1999 Resolved
Properly Secure All Electrical Wires With Metallic Clamps In Overhead Of Engine Room, Generator Compartment, and Aft Steering.
Condition: Unknown
Due 25 April 1999
Resolved 23 April 1999
Construction/Loadline
Issued 7 April 1999 Resolved
Secure Plastic Bilge Piping In Engine Room With Bands To Prevent Vibration.
Condition: Unknown
Due 25 April 1999
Resolved 27 May 1999
Construction/Loadline
Issued 7 April 1999 Resolved
Properly Secure Bilge Pump In Engine Room.
Condition: Unknown
Due 25 April 1999
Resolved 27 May 1999
Engineering
Issued 7 April 1999 Resolved
Properly Double Clamp All Non-Metallic Hoses In Engine Room, Generator Compartment and Aft Steering.
Condition: Unknown
Due 25 April 1999
Resolved 27 May 1999
Electrical
Issued 7 April 1999 Resolved
Repair Or Remove All Lights In Engine Room Without Protective Covers in Engine Room, Generator Room, and Aft Steering.
Condition: Unknown
Due 25 April 1999
Resolved 27 May 1999
Lifesaving
Issued 7 April 1999 Resolved
Properly Conduct Man Overboard and Fire Drills.
Condition: Unknown
Due 25 April 1999
Resolved 23 April 1999
Documentation
Issued 7 April 1999 Resolved
Provide Vessel Log With EPIRB and Drill Logs.
Condition: Unknown
Due 25 April 1999
Resolved 23 April 1999
Documentation
Issued 7 April 1999 Resolved
Properly Post Stability Letter.
Condition: Unknown
Due 25 April 1999
Resolved 23 April 1999
Lifesaving
Issued 7 April 1999 Resolved
Provide 6 Red Hand Flares.
Condition: Unknown
Due 25 April 1999
Resolved 23 April 1999
Construction/Loadline
Issued 7 April 1999 Resolved
Make Available for Inspection, Rotting Wood On STBD Side Amidships Where Deck Attaches To Side Of Hull In Engine Room.
Condition: Unknown
Due 25 April 1999
Resolved 27 May 1999
Lifesaving
Issued 7 April 1999 Resolved
Properly Mount Vessel's EPIRB.
Condition: Unknown
Due 25 April 1999
Resolved 23 April 1999
Lifesaving
Issued 7 April 1999 Resolved
Provide Iodine For First Aid Kit.
Condition: Unknown
Due 25 April 1999
Resolved 23 April 1999
Lifesaving
Issued 2 June 1998 Resolved
Replace 3 expired orange distress signals.
Condition: Unknown
Due 4 June 1998
Resolved 7 July 1998
Lifesaving
Issued 2 June 1998 Resolved
Replace expired battery in EPIRB. Battery expired 3/97.
Condition: Unknown
Due 4 June 1998
Resolved 7 July 1998
Lifesaving
Issued 7 April 1997 Resolved
PROPERLY REPAIR MINOR CUTS ON BOUYANCY APPARATUS.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Unknown
Issued 7 April 1997 Resolved
PROVIDE AND MAINTAIN PROPER LOGS FOR CREW TRAINING, DRILLS AND LIFESAVING EQUIPMENT INSPECTIONS.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Lifesaving
Issued 7 April 1997 Resolved
PROVIDE ONE CHILD LIFE JACKET.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Documentation
Issued 7 April 1997 Resolved
PROVIDE AND PROPERLY POST VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Lifesaving
Issued 7 April 1997 Resolved
PROVIDE AND PROPERLY DISPLAY EMERGENCY RADIO PLACARD IN THE PILOT HOUSE IN VICINITY OF VHF RADIO.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Navigation
Issued 7 April 1997 Resolved
PROPERLY RENEW OR REPLACE COTTER PIN LOCATED ON STEERING GEAR BOX.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Construction/Loadline
Issued 7 April 1997 Resolved
PROPERLY REPAIR SMALL HOLE IN COLLISION BULKHEAD.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Fire Fighting
Issued 7 April 1997 Resolved
PROVIDE AND PROPERLY MARK THREE 2.5 GALLON FIRE BUCKETS.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Lifesaving
Issued 25 February 1997 Resolved
Repair/replace inoperative waterlights on PFDs.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Engineering
Issued 25 February 1997 Resolved
Replace missing circlips/keepers @ MDE throttle linkage.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Engineering
Issued 25 February 1997 Resolved
Fabricate/install proper bracket for MDE manual shutdown teleflex cable.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Lifesaving
Issued 25 February 1997 Resolved
Replace defective ring lifebuoy. Ensure replacement complies with marking requirements as appropriate.
Condition: Unknown
Due 25 February 1997
Resolved 25 February 1997
Lifesaving
Issued 25 February 1997 Resolved
Replace 3 expired orange day flares.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Lifesaving
Issued 25 February 1997 Resolved
Provide proper segregation for child/adult lifejackets.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Navigation
Issued 25 February 1997 Resolved
Repair defective steering gear foundation @ aft steering gear box. Also replace missing keeper at box clevis pin.
Condition: Unknown
Due 3 March 1997
Resolved 3 March 1997
Accommodation/Occupational Safety
Issued 25 June 1996 Resolved
Replace hose clamps on fresh water line to hot water heater._x001C_
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Navigation
Issued 25 June 1996 Resolved
Renew/reair worn steering linkage on rudder and steering box.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Engineering
Issued 25 June 1996 Resolved
replace repair exhaust elbow on main diesel engine.
Condition: Unknown
Due 25 June 1996
Resolved 25 June 1996
Documentation
Issued 10 April 1996 Resolved
produce FCC station license.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Lifesaving
Issued 10 April 1996 Resolved
repair detriorated life floats.
Condition: Unknown
Due 10 April 1996
Resolved 10 April 1996
Deck/Cargo
Issued 10 April 1996 Resolved
prove proper operation of the anchor winch.
Condition: Unknown
Due 25 April 1996
Resolved 7 May 1996
Navigation
Issued 10 April 1996 Resolved
prove proper operation of red navigation light.
Condition: Unknown
Due 25 April 1996
Resolved 7 May 1996
Electrical
Issued 10 April 1996 Resolved
line battery box with lead or FRP.
Condition: Unknown
Due 25 April 1996
Resolved 7 May 1996
Electrical
Issued 10 April 1996 Resolved
remove spring clips on battery chargers.
Condition: Unknown
Due 25 April 1996
Resolved 7 May 1996
Lifesaving
Issued 10 April 1996 Resolved
restring tending line on ring buoy._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 April 1996
Resolved 7 May 1996
Documentation
Issued 10 April 1996 Resolved
provide MARPOL V garbage plan.
Condition: Unknown
Due 25 April 1996
Resolved 7 May 1996
Engineering
Issued 10 April 1996 Resolved
replace flame screen on port fuel tank.
Condition: Unknown
Due 25 April 1996
Resolved 7 May 1996
Documentation
Issued 13 April 1994 Resolved
OPERATOR TO RECEIVE PROPER FCC DOCUMENTATION FOR RADIO OPERATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 April 1994
Resolved 13 April 1994
Documentation
Issued 8 April 1992 Resolved
PROVIDE DOCUMENTATION TO SUPPORT COMPLIANCE WITH THE PROGRAM FOR CHEMICAL DRUG AND ALCOHOL TESTING OF COMMERCIAL VESSEL PERSONNEL IN ACCORDANCE WITH 46 CFR 16.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Documentation
Issued 8 April 1992 Resolved
PROVIDE ALL REQUIRED RADIO EQUIPMENTS OUTLINED IN 47 CFR 80.905(a)(3), OR OBTAIN AN EXEMPTION FROM FCC. VESSEL ROUTE LIMITED TO NOT MORE THAN 100 MILES OFF THE MAINLAND.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Construction/Loadline
Issued 28 February 1992 Resolved
EFFECT REPAIRS TO BOW AREA INCLUDING STEM AND ANY ASSOCIATED DAMAGE. REPAIRS TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 28 February 1992
Resolved 28 February 1992
Engineering
Issued 9 April 1991 Resolved
REPAIR INOPERABLE BILGE PUMP IN THE ENGINEROOM. _x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Accommodation/Occupational Safety
Issued 9 April 1991 Resolved
INSTALL A METERED FLUSHOMETER OF NOT MORE THAN 1/2 GALLON PER FLUSH FOR THETOILET. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 April 1991
Resolved 9 April 1991
Accommodation/Occupational Safety
Issued 12 April 1989 Resolved
REPAIR OR REPLACE LEAKING MSD HOLDING TANK TO MAKE THE SYSTEM OPERABLE.
Condition: Unknown
Due 12 April 1989
Resolved 12 April 1989
Unknown
Issued 20 April 1988 Resolved
REPLACE EXHAUST VENT EXTENDING NEAR THE BILGES IN ENGINEROOM WITH SHEET METAL VENT DUCTING.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Electrical
Issued 20 April 1988 Resolved
INSTALL A FREQUENCY METER FOR SERVICE GENERATOR.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Lifesaving
Issued 20 April 1988 Resolved
REPLACE BATTERIES ON ALL LIFE PRESERVERS ON OR BEFORE 30DEC88.
Condition: Unknown
Due 20 April 1988
Resolved 20 April 1988
Construction/Loadline
Issued 29 December 1987 Resolved
INSTALL A COLLISION BULKHEAD IN ACCORDANCE WITH 46CFR171.085(H),(I),AND (J)AS REQUIRED IN 46CFR171.040(B). REQUIREMENT IS TO BE COMPLETED PRIOR TO PLACING VESSEL IN OCEAN ROUTE OPERATION.
Condition: Unknown
Due 29 December 1987
Resolved 29 December 1987
Fire Fighting
Issued 28 April 1987 Resolved
DEMONSTRATE HAND HELD FIRE PUMP WITH SUCTION HOSE.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Navigation
Issued 28 April 1987 Resolved
PROVIDE UP TO DATE TIDAL CURRENT TABLES.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Navigation
Issued 28 April 1987 Resolved
PROVIDE 8 INCH BELL.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Engineering
Issued 28 April 1987 Resolved
REPLACE FLAME SCREENS IN FUEL TANK VENTS.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Lifesaving
Issued 28 April 1987 Resolved
PRESENT LIFE FLOATS FOR INSPECTION.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Construction/Loadline
Issued 28 April 1987 Resolved
STENCIL LIFE PRESERVER STOWAGE AND HAILING PORT ON TRANSOM.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Lifesaving
Issued 21 April 1986 Resolved
RENEW LINES ON LIFE RING.
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Engineering
Issued 21 April 1986 Resolved
INSTALL EXHUAST VENT FROM BILGE AREA IN ENGINE ROOM.
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986

Casualty record · 3

11 July 2007Routine · role: Involved in a Marine Casualty · activity 2997526
2 July 2019Routine · role: Involved in a Marine Casualty · activity 6782617
3 November 2025Routine · role: Involved in a Marine Casualty · activity 8262734
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.