MAURY USCG vessel records
← All vessels

ISLAND HOPPER

Built
1995
Last inspected
23 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 23 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDM3450
433974
Flag
UNITED STATES
Maury page id
psix-433974

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS INC · TARPON SPRINGS, FL, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portSANIBEL, FL
Endorsements, as the file codes themcw_un
DocumentationValid · issued 8 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Net Ton
11 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 44 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

23 April 2026 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8354491
21 May 2025 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8136409
4 June 2024 Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7926017
22 May 2024 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7916195
15 February 2023 COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7636790
13 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576906
2 June 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7465485
11 May 2022 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7447664
28 July 2021 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7271043
27 July 2021 Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7269508
27 May 2021 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7207147
7 May 2021 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7191636
16 June 2020 Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6974631
8 May 2020 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6952977
10 May 2019 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6680203
4 June 2018 Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6431411
8 February 2018 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6350112
11 August 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6237195
23 August 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5982054

Deficiency record · 44

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 May 2025 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. The name of the vessel is not marked on the exterior part of the port and starboard bow. Mark the name of the vessel on the exterior part of the port and starboard bow. 46CFR67.123
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2025
Resolution: The name of the vessel is now marked on the port and starboard bow and the stern of the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 May 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The passenger ladder on the bow used for disembarking passengers on the beach is not properly secured to the deck. Make permanent repairs to the passenger ladder on the bow to the satisfaction of the attending CG Marine Inspector. Beaching operations are prohibited until corrected. 46CFR176.830
Action required: 705 - Other - as specified
Resolved 29 May 2025
Resolution: The passenger ladder on the bow used for disembarking passengers on the beach is now properly secured to the deck.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 February 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The Safety Radio Certificate was expired. Restricted to not more than 1,000 feet from shore until rectified. 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2023
Resolved 23 February 2023
Resolution: New Safety Radio Certificate issued.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 February 2023 Resolved
VHF radio is inoperable. Repair radio to satisfaction of attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2023
Resolved 23 February 2023
Resolution: Radio was properly installed and tested satisfactorily.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 February 2023 Resolved
Vessel was past due for COI inspection.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 February 2023
Resolved 15 February 2023
Resolution: Completed satisfactory COI inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 May 2022 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the stern. Vessel name and homeport not marked on stern. 46 CFR 67.123(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Name of vessel marked on hull.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 May 2022 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented. No records could be found of any drills in the past 03 months. 46 CFR 185.520(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Drills were logged.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2022 Resolved
Portable fire extinguishers must be installed and located to the satisfaction of the OCMI. 2-A extinguisher under the helm was not secured to a bracket and could easily roll out onto the deck. 46 CFR 181.520
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Fire extinguisher bracket installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2022 Resolved
Each vessel must be equipped with at least two operable portable battery lights. 01 flashlight did not function. 46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Flashlights working.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 May 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date Coast Pilot [name withheld] was onboard. 46 CFR 184.420
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Coast Pilot onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2022 Resolved
The number and identification of the items stowed inside, must be marked in clearly legible letters and numbers. Lifejacket stowage did not show child life jackets and the numbers were faded on all containers. 46 CFR 185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Lifejacket stowage marked.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 May 2022 Resolved
The monthly EPIRB test shall be logged or otherwise documented. No records of EPIRB testing could be provided. 46 CFR 185.728(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: EPIRB log created.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 May 2022 Resolved
Your vessel must undergo an annual inspection within 03 months before or after each anniversary date. Annual inspection was overdue on 09MAY2022. 46 CFR 176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 May 2022
Resolved 11 May 2022
Resolution: Completed inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 July 2021 Resolved
A vessel must comply with the structural design requirements of one of the standards lsited below for the hull material of the vessel. FRP: Lloyd's Yacht/ABS Plastic/ABS High Speed Craft. Vessel suffered a grounding on 25JUL2021. Prior to carrying passengers, a damage survey shall be conducted by a Marine Inspector to assess overall seaworthiness of the vessel.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2021
Resolved 27 July 2021
Resolution: Conducted internal structural exam and visual inspection of hull. Satisfactory test of propulsion and steering witnessed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 May 2021 Resolved
EPIRB registration expired. Restricted to LBS route until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Received updated EPIRB registration.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 May 2021 Resolved
Hydrostatic release unit for EPIRB expires May 2021 - replace before the end of the month.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: New HRU placed - expiration set for May 2023.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 May 2021 Resolved
Navigation lights do not display correct arc of visibiity. Repalce with navigation lights to meet Inland Rules.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Navigation lights placed in proper position to meet arc of visibility.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 May 2021 Resolved
08 flares missing. Provide new flares for 12 total.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: New red hand flares onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2021 Resolved
Light for ring buoy is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Batteries replaced for ring buoy light.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 May 2021 Resolved
Provide 03 2.5 gallon fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Fire buckets placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2021 Resolved
Lifejacket stowage does not provide for easy retrieval of jackets. Stow jackets in a manner that allow for easy access.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Life jacket stowage removed from interior of hulls. Wooden slats placed in stowage area to allow for retrieval from the main deck.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 May 2021 Resolved
Electrical run for navigation light is not properly secured with metal clamps every 24 inches.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Electrical cable properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2021 Resolved
Fuel lines are not double clamped at connection points.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Clamps placed on fuel lines.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 May 2021 Resolved
Emergency fuel shut offs are not labeled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Placards provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 May 2021 Resolved
Operator failed to make vessel available for Annual Inspection in required time frame. COI is now invalid. Vessel cannot operate until Annual Inspection is completed by CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2021
Resolution: Completed annual inspection.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 May 2019 Resolved
Repair/replace inoperative port side high water alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2019
Resolution: Repaired high water alarm.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 May 2019 Resolved
Update medical kit
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Purchased new medical kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2019 Resolved
Reapply lifejacket stowage location/#
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Numbered life jacktets in containers.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 May 2019 Resolved
Update navigation charts
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Purchased new chart.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 May 2019 Resolved
Provide current Coast Pilot
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Bought new Coast Pilot.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 May 2019 Resolved
Provide all logs
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Started logs.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 May 2019 Resolved
Replace expired Epirb hydrostatic release
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Installed new hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2019 Resolved
Provide line for buoyant line
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Installed new line with proper length.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 May 2019 Resolved
Provide portable lights
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Purchased two new lights.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 February 2018 Resolved
1. Vessel's FCC safety certificate is expired. Do not operate more than 1000' from shore until new certificate is obtained. (47CFR13)
Action required: 705 - Other - as specified
Resolved 14 February 2018
Resolution: Completed inspeection by a licensed FCC inspector.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 August 2017 Resolved
Provide 6 addtional lifejackets to meet required quantity.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: verified correct number, cleared def.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 August 2017 Resolved
Mark location for lifejackets.
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 15 August 2017
Resolution: Verified stowaged marked properly, cleared def.
Fire Fighting › Fire Bucket › Quantity
Issued 11 August 2017 Resolved
Provide 2 fire buckets to comply with required quantity and mark accordingly.
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 15 August 2017
Resolution: Verified fire buckets, def cleared.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 August 2017 Resolved
Replace masthead light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: verified nav light opearational, cleared def.
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 August 2017 Resolved
Need donning placard for lifejackets.
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 15 August 2017
Resolution: Verified placard, def cleared.
Engineering › Bilge Water Management System › Not Operational
Issued 11 August 2017 Resolved
Port side bilge pumps (2) not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: verified all bilge pumps operational, cleared def.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 August 2016 Resolved
Conduct required dry-dock and internal structural examination; overdue since 04JUN16.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2016
Resolved 31 August 2016
Resolution: Vessel completed a satisfactory Dry-Dock and Internal Structura Exam. Deficiency cleared. DD/ISE credited for 31AUG16.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 August 2016 Resolved
Satisfactorily undergo required annual inspection. COI issued on 28MAY13. Last inspection completed on 02JUL15.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2016
Resolved 1 September 2016
Resolution: Vessel completed satisfactory annual inspection. Deficiency has been cleared.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 August 2016 Resolved
Provide servicing report for portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2016
Resolution: Rcvd service report.

Recorded names · 1

BOBDIVE I (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.