MAURY USCG vessel records Sign in
← All vessels

ISLAND HOPPER

ISLAND HOPPER is a 1995 passenger vessel (inspected). The Coast Guard has recorded 55 inspections since 1995, most recently in April 2026, along with 116 deficiencies, 1 operational control and 2 casualty investigations between 2013 and 2021.

Records from 1995 to 2026. Most recent: inspection, 23 April 2026.

Built
1995
Last inspected
23 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM3450
433974
Flag
UNITED STATES
368197360
Maury page id
psix-433974

Inspections, by type

…with no type recorded2
Years with a record 29 calendar years (1995–2026)
The 55 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)45.0 ft × 14.0 ft × 3.5 ft
Registered tonnagegross 11 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS INC · TARPON SPRINGS, FL, UNITED STATES · built 1995
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portSANIBEL, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 8 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Simplified, Net Ton
11 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM3450MMSI 368197360 · active · compulsorily equipped · granted 6 May 2021, expires 6 May 2031
WDF3226MMSI 367437440 · expired · compulsorily equipped · granted 21 January 2010, cancelled 28 March 2020
WDF2018MMSI 367423910 · expired · compulsorily equipped · granted 1 September 2009, cancelled 2 November 2019 · licensed under a name not among this hull’s recorded names (not shown)
WCY6839MMSI not assigned · expired · compulsorily equipped · granted 9 September 1998, cancelled 15 November 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 55

23 April 2026 Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8354491
21 May 2025 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8136409
4 June 2024 Hull Examination · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7926017
22 May 2024 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7916195
15 February 2023 COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7636790
13 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7576906
2 June 2022 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7465485
11 May 2022 Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7447664
28 July 2021 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7271043
27 July 2021 Damage Survey
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7269508
27 May 2021 Deficiency Check · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7207147
7 May 2021 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7191636
16 June 2020 Internal Structural Exam · Administrative Inspection · Deficiency Check · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6974631
8 May 2020 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6952977
10 May 2019 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6680203
4 June 2018 Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6431411
8 February 2018 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6350112
11 August 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6237195
23 August 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5982054
4 June 2014 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4879160
17 July 2012 Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4381470
29 June 2012 Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4365870
24 January 2012 Simplified Stability Test
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4230456
30 August 2011 Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 4130595
11 January 2011 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3924624
4 February 2010 Administrative Inspection
Administrative · Sector Key West · USCG Southeast District (CGD-SE) · Activity 3675262
28 January 2010 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3669917
19 June 2008 Hull Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3240672
22 May 2008 Deficiency Check · COI Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3213593
15 May 2008 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3207241
19 March 2007 Annual Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 2890597
18 July 2006 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2715818
31 May 2006 Hull Examination
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2666023
19 April 2005 Re-Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 2336637
29 April 2004 Re-Inspection · In-Service Inspection · Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 2053618
15 April 2003 COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1773957
3 April 2002 Hull Examination
Physical examination · MSD MARATHON · USCG Southeast District (CGD-SE) · Activity 1598789
8 May 2001 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1423567
7 July 2000 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 820344
26 June 2000 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1393464
31 March 2000 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1464929
8 July 1999 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1433517
8 May 1998 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1125257
22 April 1998 Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1125255
26 January 1998 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 780786
9 December 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1113762
19 November 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1108050
10 October 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1109756
7 July 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1114492
28 April 1997 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1106144
5 March 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1091961
21 February 1997 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1092680
14 January 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1104528
4 March 1996 Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1189796
8 December 1995 Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1363674

Deficiency record · 116

01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 21 May 2025 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. The name of the vessel is not marked on the exterior part of the port and starboard bow. Mark the name of the vessel on the exterior part of the port and starboard bow. 46CFR67.123
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 May 2025
Resolution: The name of the vessel is now marked on the port and starboard bow and the stern of the vessel.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 21 May 2025 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition. The passenger ladder on the bow used for disembarking passengers on the beach is not properly secured to the deck. Make permanent repairs to the passenger ladder on the bow to the satisfaction of the attending CG Marine Inspector. Beaching operations are prohibited until corrected. 46CFR176.830
Action required: 705 - Other - as specified
Resolved 29 May 2025
Resolution: The passenger ladder on the bow used for disembarking passengers on the beach is now properly secured to the deck.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 February 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The Safety Radio Certificate was expired. Restricted to not more than 1,000 feet from shore until rectified. 46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2023
Resolved 23 February 2023
Resolution: New Safety Radio Certificate issued.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 February 2023 Resolved
VHF radio is inoperable. Repair radio to satisfaction of attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 March 2023
Resolved 23 February 2023
Resolution: Radio was properly installed and tested satisfactorily.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 15 February 2023 Resolved
Vessel was past due for COI inspection.
Action required: 60 - Rectify deficiencies prior to movement
Due 15 February 2023
Resolved 15 February 2023
Resolution: Completed satisfactory COI inspection.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 May 2022 Resolved
The name of the vessel must be marked on some clearly visible exterior part of the stern. Vessel name and homeport not marked on stern. 46 CFR 67.123(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Name of vessel marked on hull.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 May 2022 Resolved
Abandon ship and man overboard drills and training shall be logged or otherwise documented. No records could be found of any drills in the past 03 months. 46 CFR 185.520(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Drills were logged.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2022 Resolved
Portable fire extinguishers must be installed and located to the satisfaction of the OCMI. 2-A extinguisher under the helm was not secured to a bracket and could easily roll out onto the deck. 46 CFR 181.520
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Fire extinguisher bracket installed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 11 May 2022 Resolved
Each vessel must be equipped with at least two operable portable battery lights. 01 flashlight did not function. 46 CFR 183.430
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Flashlights working.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 May 2022 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date Coast Pilot [name withheld] was onboard. 46 CFR 184.420
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Coast Pilot onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 May 2022 Resolved
The number and identification of the items stowed inside, must be marked in clearly legible letters and numbers. Lifejacket stowage did not show child life jackets and the numbers were faded on all containers. 46 CFR 185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: Lifejacket stowage marked.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 11 May 2022 Resolved
The monthly EPIRB test shall be logged or otherwise documented. No records of EPIRB testing could be provided. 46 CFR 185.728(c)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 May 2022
Resolved 23 May 2022
Resolution: EPIRB log created.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 11 May 2022 Resolved
Your vessel must undergo an annual inspection within 03 months before or after each anniversary date. Annual inspection was overdue on 09MAY2022. 46 CFR 176.500(b)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 May 2022
Resolved 11 May 2022
Resolution: Completed inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 27 July 2021 Resolved
A vessel must comply with the structural design requirements of one of the standards lsited below for the hull material of the vessel. FRP: Lloyd's Yacht/ABS Plastic/ABS High Speed Craft. Vessel suffered a grounding on 25JUL2021. Prior to carrying passengers, a damage survey shall be conducted by a Marine Inspector to assess overall seaworthiness of the vessel.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2021
Resolved 27 July 2021
Resolution: Conducted internal structural exam and visual inspection of hull. Satisfactory test of propulsion and steering witnessed.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 May 2021 Resolved
EPIRB registration expired. Restricted to LBS route until rectified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Received updated EPIRB registration.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 27 May 2021 Resolved
Hydrostatic release unit for EPIRB expires May 2021 - replace before the end of the month.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: New HRU placed - expiration set for May 2023.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 27 May 2021 Resolved
Navigation lights do not display correct arc of visibiity. Repalce with navigation lights to meet Inland Rules.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Navigation lights placed in proper position to meet arc of visibility.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 27 May 2021 Resolved
08 flares missing. Provide new flares for 12 total.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: New red hand flares onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 27 May 2021 Resolved
Light for ring buoy is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Batteries replaced for ring buoy light.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 May 2021 Resolved
Provide 03 2.5 gallon fire buckets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Fire buckets placed onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 May 2021 Resolved
Lifejacket stowage does not provide for easy retrieval of jackets. Stow jackets in a manner that allow for easy access.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Life jacket stowage removed from interior of hulls. Wooden slats placed in stowage area to allow for retrieval from the main deck.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 27 May 2021 Resolved
Electrical run for navigation light is not properly secured with metal clamps every 24 inches.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Electrical cable properly secured.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 27 May 2021 Resolved
Fuel lines are not double clamped at connection points.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Clamps placed on fuel lines.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 27 May 2021 Resolved
Emergency fuel shut offs are not labeled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 June 2021
Resolved 4 June 2021
Resolution: Placards provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 7 May 2021 Resolved
Operator failed to make vessel available for Annual Inspection in required time frame. COI is now invalid. Vessel cannot operate until Annual Inspection is completed by CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2021
Resolution: Completed annual inspection.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 10 May 2019 Resolved
Repair/replace inoperative port side high water alarm
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 May 2019
Resolution: Repaired high water alarm.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 May 2019 Resolved
Update medical kit
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Purchased new medical kit.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 May 2019 Resolved
Reapply lifejacket stowage location/#
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Numbered life jacktets in containers.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 May 2019 Resolved
Update navigation charts
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Purchased new chart.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 May 2019 Resolved
Provide current Coast Pilot
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Bought new Coast Pilot.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 May 2019 Resolved
Provide all logs
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Started logs.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 10 May 2019 Resolved
Replace expired Epirb hydrostatic release
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Installed new hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 May 2019 Resolved
Provide line for buoyant line
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Installed new line with proper length.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 10 May 2019 Resolved
Provide portable lights
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2019
Resolved 21 May 2019
Resolution: Purchased two new lights.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 8 February 2018 Resolved
1. Vessel's FCC safety certificate is expired. Do not operate more than 1000' from shore until new certificate is obtained. (47CFR13)
Action required: 705 - Other - as specified
Resolved 14 February 2018
Resolution: Completed inspeection by a licensed FCC inspector.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 August 2017 Resolved
Provide 6 addtional lifejackets to meet required quantity.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: verified correct number, cleared def.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 11 August 2017 Resolved
Mark location for lifejackets.
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 15 August 2017
Resolution: Verified stowaged marked properly, cleared def.
Fire Fighting › Fire Bucket › Quantity
Issued 11 August 2017 Resolved
Provide 2 fire buckets to comply with required quantity and mark accordingly.
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 15 August 2017
Resolution: Verified fire buckets, def cleared.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 August 2017 Resolved
Replace masthead light.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: verified nav light opearational, cleared def.
Documentation › Markings/Placards › Lifejacket Placard
Issued 11 August 2017 Resolved
Need donning placard for lifejackets.
Action required: 705 - Other - as specified
Due 25 August 2017
Resolved 15 August 2017
Resolution: Verified placard, def cleared.
Engineering › Bilge Water Management System › Not Operational
Issued 11 August 2017 Resolved
Port side bilge pumps (2) not operational.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2017
Resolution: verified all bilge pumps operational, cleared def.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 August 2016 Resolved
Conduct required dry-dock and internal structural examination; overdue since 04JUN16.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2016
Resolved 31 August 2016
Resolution: Vessel completed a satisfactory Dry-Dock and Internal Structura Exam. Deficiency cleared. DD/ISE credited for 31AUG16.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 23 August 2016 Resolved
Satisfactorily undergo required annual inspection. COI issued on 28MAY13. Last inspection completed on 02JUL15.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 August 2016
Resolved 1 September 2016
Resolution: Vessel completed satisfactory annual inspection. Deficiency has been cleared.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 August 2016 Resolved
Provide servicing report for portable fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 31 October 2016
Resolution: Rcvd service report.
Stability › Weathertight Integrity › General
Issued 29 June 2012 Resolved
Make hatch covers watertight.
Condition: Improper/Lack of Maintenance
Due 29 July 2012
Resolved 17 July 2012
Resolution: Master used 5200 to seal hatch covers.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 29 June 2012 Resolved
Install proper brackets for fire extinguishers.
Condition: Placed in Improper Service
Due 29 July 2012
Resolved 29 July 2012
Resolution: Proper brackets were installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 29 June 2012 Resolved
Replace wing nuts on batteries with locking type nuts.
Condition: Placed in Improper Service
Due 7 July 2012
Resolved 17 July 2012
Resolution: Master installed appropriate locking nuts.
Construction/Loadline › Structures › Deck Plating
Issued 24 January 2012 Resolved
At next dry dock exam, examine deck flexing at 3' 6" centerline aft section w/ U.S. Coast Guard in Attendance. Submit Repair proposal if needed.
Due 31 July 2012
Resolved 17 July 2012
Resolution: Vessel showed no indications of a failure in this area.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 30 August 2011 Resolved
Acquire valid FCC radiotelephony certificate.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2011
Resolved 30 August 2011
Resolution: FCC certificate obtained upon reinspection.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 30 August 2011 Resolved
Acquire 03 child PFDs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2011
Resolved 30 August 2011
Resolution: Child PFDs acquired during inspection.
Engineering › Gasoline Engine (propulsion) › Backfire Flame Control
Issued 30 August 2011 Resolved
Properly install flame mesh on both fuel vents.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2011
Resolved 30 August 2011
Resolution: Flame screens installed correctly.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 30 August 2011 Resolved
Acquire new publications.
Due 2 September 2011
Resolved 2 September 2011
Engineering › Bilge Water Management System › Piping
Issued 30 August 2011 Resolved
Double clamp port thru-hull hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2011
Resolved 30 August 2011
Resolution: Port thru-hull hose double clamped.
Engineering › Bilge Water Management System › Pump
Issued 30 August 2011 Resolved
Acquire portable bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2011
Resolved 30 August 2011
Resolution: Pump acquired during inspection.
Documentation › Markings/Placards › Warning Signs
Issued 30 August 2011 Resolved
Post COI and stability letter.
Due 30 August 2011
Resolved 30 August 2011
Resolution: COI and Stability Letter posted.
Lifesaving › Lifefloat › Serviceable
Issued 10 February 2010 Resolved
Port side life float needs painted, faded not proper color.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 February 2010
Resolved 18 February 2010
Resolution: Life float painted bright orange. All Sat.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 10 February 2010 Resolved
Starboard life float needs a float light attached.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2010
Resolution: New float light installed. All Sat.
Lifesaving › Lifefloat › Lifeline
Issued 10 February 2010 Resolved
Both lifefloat life line holders are broken, repair or replace life line holders.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2010
Resolution: New life line holders installed. All Sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 10 February 2010 Resolved
Provide locking/securing device for boarding ladder on starboard side of vessel.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2010
Resolution: Securing device properly installed. All sat.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 10 February 2010 Resolved
Provide training for all employees.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 March 2010
Resolved 18 February 2010
Resolution: Training CD supplied, training logged for all employees.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 4 February 2010 Resolved
Replace all clips on hand rail opening life lines.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 February 2010
Resolved 18 February 2010
Resolution: New clips installed. All sat.
Documentation › Logs/Records › Logbook (official)
Issued 28 January 2010 Resolved
Provide current crew training logbook to the satisfaction of CG Sector Key West.
Action required: 705 - Other - as specified
Resolved 18 February 2010
Resolution: New log book started for drills, inspections etc.
Operations/Management › Drills/Instruction › Fire
Issued 28 January 2010 Resolved
Conduct drills with crew prior to carriage of passengers and to the satisfaction of CG Sector Key West.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 February 2010
Resolution: Coducted drills in Sector Kw Zone.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 28 January 2010 Resolved
Provide proof that the crew is enrolled in the company consortium and that the vessel has proper drug and alcohol program in place to the satisfaction of CG Sector Key West.
Action required: 705 - Other - as specified
Resolved 18 February 2010
Resolution: Proof of drug consortium enrollment provided,.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 June 2008 Resolved
Remove dead ended wire starboard side, midship, or end in an approved electrical box.
Action required: 705 - Other - as specified
Resolved 19 June 2008
Resolution: Corrected on the spot.
Construction/Loadline › Penetrations › Valve Flange
Issued 19 June 2008 Resolved
Repair or replace non-closing ball valve for raw water intake to head.
Action required: 705 - Other - as specified
Resolved 19 June 2008
Resolution: Corrected on the spot.
Construction/Loadline › Hull › Hull Plating
Issued 19 June 2008 Resolved
Cut back wasted wood, starboard side, forward, main deck and make repairs to original condition.
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 24 August 2009
Construction/Loadline › Hull › Hull Plating
Issued 19 June 2008 Resolved
Grind back fiberglass on port and starboard bow, and make proper repairs to original condition.
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 24 August 2009
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 19 June 2008 Resolved
Change name on Port and Starboard side to DEEP RELIEF vice DEEP RELIEF II.
Action required: 705 - Other - as specified
Due 19 July 2008
Resolved 24 August 2009
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 May 2008 Resolved
Provide valid certificate of documentation.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 22 May 2008 Resolved
Provide valid radio safety certificate.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 19 June 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 22 May 2008 Resolved
Provide DAPI proof of enrollment for [name withheld].
Action required: 705 - Other - as specified
Resolved 30 May 2008
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 22 May 2008 Resolved
Conduct DAPI audit with Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 22 May 2008 Resolved
Provide valid alcohol test kits.
Action required: 705 - Other - as specified
Due 6 June 2008
Resolved 3 June 2008
Lifesaving › Lifefloat › Serviceable
Issued 22 May 2008 Resolved
Properly refurbish cracked / discolored lifefloat
Action required: 705 - Other - as specified
Resolved 30 May 2008
Lifesaving › Lifefloat › Retroreflective Material
Issued 22 May 2008 Resolved
Replace retro-reflective tape on lifefloat as needed.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 22 May 2008 Resolved
Provide current edition of Coast Pilot [name withheld], Tides & Currents, and Chart for area vsl operates in.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Communications › Alarms/Indicators › Bilge Alarm
Issued 22 May 2008 Resolved
Prove proper operation of bilge high level alarms and label breakers.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 22 May 2008 Resolved
Provide emergency broadcast placard.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Operations/Management › Vessel Safety Management › Designated Person(s)
Issued 22 May 2008 Resolved
Provide emergency contact information
Action required: 705 - Other - as specified
Resolved 30 May 2008
Navigation › Piloting/Steering › Magnetic Compass
Issued 22 May 2008 Resolved
Prove proper operation of magnetic compass light.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 22 May 2008 Resolved
Stencil proper name on all lifejackets and life ring buoy.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 22 May 2008 Resolved
Proper apply retroreflective tape to 3 adult life jackets.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Engineering › Bilge Water Management System › Pump
Issued 22 May 2008 Resolved
Prove proper operation of Stbd aft bilge pump.
Action required: 705 - Other - as specified
Resolved 30 May 2008
Fire Fighting › Fire Bucket › Quantity
Issued 29 March 2007 Resolved
Provide 03 2.5 gallon fire buckets on vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2007
Resolved 4 April 2007
Resolution: fax
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 29 March 2007 Resolved
Provide evidence that all crew members are enrolled in a company drug testing program. Provide proof of satisfactory completion of items in drug audit marked un-sat.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2007
Resolved 4 April 2007
Resolution: fax
Engineering › Steering Gear System › Actuator
Issued 29 March 2007 Resolved
Make proper repairs and prove proper operation of vessel steering system.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2007
Resolved 3 April 2007
Resolution: onboard
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 29 March 2007 Resolved
Provide 02 serviceable B-II fire extinguishers onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2007
Resolved 3 April 2007
Resolution: onboard
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 29 March 2007 Resolved
Provide proof of current Certificate of Documentation.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 3 April 2007
Resolution: onboard
Documentation › Certificates/Documents › FCC SSL
Issued 29 March 2007 Resolved
Provide proof of FCC Radio Safety Certificate.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 3 April 2007
Resolution: onboard
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 29 March 2007 Resolved
Post Emergency Instructions onboard.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 4 April 2007
Resolution: fax
Communications › Audible Communications › Bell
Issued 29 March 2007 Resolved
Provide 7.8" Bell onboard.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 4 April 2007
Resolution: fax
Lifesaving › Hand Flares › Marking
Issued 29 March 2007 Resolved
Label "Distress Signals" box.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 3 April 2007
Resolution: onboard
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 March 2007 Resolved
Renew/Replace and properly mark PFD Stowage.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 4 April 2007
Resolution: fax
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 March 2007 Resolved
Provide physical barrier for child size PFD's.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 4 April 2007
Resolution: fax
Communications › Radio Communications › EPIRB
Issued 29 March 2007 Resolved
Renew/replace hydrostatic release.
Action required: 705 - Other - as specified
Due 6 April 2007
Resolved 4 April 2007
Resolution: fax
Lifesaving › Lifefloat › Float-free Link
Issued 18 July 2006 Resolved
Replace stbd and port side weak links for both lifefloats.
Action required: 705 - Other - as specified
Due 18 August 2006
Resolved 29 March 2007
Resolution: onboard
Lifesaving › Lifefloat › Painter
Issued 18 July 2006 Resolved
Replace UV damaged painter on port side lifefloat.
Action required: 705 - Other - as specified
Due 18 August 2006
Resolved 29 March 2007
Resolution: onboard
Communications › Radio Communications
Issued 15 April 2003 Resolved
Renew EPIRB Battery or replace EPIRB prior to carrying passengers. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 April 2003
Resolution: Corrected
Lifesaving
Issued 15 April 2003 Resolved
Replace floating waterlights (20 for 18 person Life Floats/Buoyant Apparatus. LEGACY COMPONENT DESC: Floating Water Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 April 2003
Resolution: Corrected.
Lifesaving › Buoyant Apparatus
Issued 15 April 2003 Resolved
Repair or replace both 18 person lifefloats/BA.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 April 2003
Resolution: Corrected.
Lifesaving › Lifejacket/PFD (Type I)
Issued 15 April 2003 Resolved
Renew retroreflective tape on 15 PFDs LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 April 2003
Resolution: Corrected
Electrical › Electrical Distribution System (service)
Issued 15 April 2003 Resolved
Replace wire nuts on water pump in starboard hull w/crimp connectors. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 24 April 2003
Resolution: Corrected
Fire Fighting › Miscellaneous Items
Issued 15 April 2003 Resolved
Provide (3) fire buckets. LEGACY COMPONENT DESC: Fire Buckets
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 24 April 2003
Resolution: Corrected
Engineering
Issued 8 May 2001 Resolved
Provide spec sheet for new 250 hp outboard motors.
Condition: Unknown
Due 9 May 2001
Resolved 14 May 2001
Construction/Loadline
Issued 8 May 2001 Resolved
Repair high water alarms prior to opeation.
Condition: Unknown
Due 8 May 2001
Resolved 14 May 2001
Navigation
Issued 8 May 2001 Resolved
Replace stbd sude running light.
Condition: Unknown
Due 15 May 2001
Resolved 3 April 2002
Fire Fighting
Issued 26 June 2000 Resolved
Service all portable extinguishers by 30JUN00.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Lifesaving
Issued 26 June 2000 Resolved
Provide log for L/S Equip Test & drills.
Condition: Unknown
Due 26 June 2000
Resolved 28 June 2000
Accommodation/Occupational Safety
Issued 26 June 2000 Resolved
Repair stern ladder by 30Jun00.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Lifesaving
Issued 26 June 2000 Resolved
Develop & post emergency procedures for man overboard & fire.
Condition: Unknown
Due 26 June 2000
Resolved 26 June 2000
Lifesaving
Issued 26 June 2000 Resolved
Replace hydrostatic release for EPIRB.
Condition: Unknown
Due 26 June 2000
Resolved 28 June 2000
Lifesaving
Issued 8 July 1999 Resolved
Provide log for man-ovbd & fire drills.
Condition: Unknown
Due 19 July 1999
Resolved 6 August 1999
Construction/Loadline
Issued 8 July 1999 Resolved
Repair/renew stbd aft bilge pump. Repair/renew by 13JUL99.
Condition: Unknown
Due 19 July 1999
Resolved 6 August 1999
Engineering
Issued 8 July 1999 Resolved
Tighten stbd engine throttle cable & remove old transducer.
Condition: Unknown
Due 19 July 1999
Resolved 6 August 1999
Documentation
Issued 14 January 1997 Resolved
Provide FCC Radio Safety Certificate.
Condition: Unknown
Due 14 January 1997
Resolved 14 January 1997

Casualty record · 2

3 May 2013Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4585511
28 July 2021Routine · role: Involved in a Marine Casualty · activity 7271043
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

BOBDIVE I (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.