MAURY USCG vessel records Sign in
← All vessels

ADVENTURER 2

ADVENTURER 2 is a 1991 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 1995, most recently in June 2026, along with 36 deficiencies and 2 operational controls.

Records from 1995 to 2026. Most recent: inspection, 3 June 2026.

Built
1991
Last inspected
3 June 2026
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

433995
Flag
UNITED STATES
—
Maury page id
psix-433995

Inspections, by type

Years with a record 24 calendar years (1995–2026)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Simplified, Net Ton
4 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

3 June 2026 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8368678
9 June 2025 Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8155556
15 November 2024 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8029424
20 March 2024 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7874472
22 May 2023 Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7693821
22 March 2023 COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7646338
9 February 2021 Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7134616
4 September 2020 Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7041903
11 November 2019 DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6848544
18 December 2018 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6599842
27 November 2018 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6579939
3 May 2018 Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6405051
2 November 2017 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6299654
14 November 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6033157
19 April 2016 Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5857820
7 December 2015 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5772435
22 October 2014 Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5009879
5 May 2014 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4850670
15 May 2012 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4431326
10 April 2009 Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3462907
18 June 2008 Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3239609
29 April 2008 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3195848
28 June 2007 Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2976240
20 June 2006 Hull Examination · COI Inspection · Simplified Stability Test
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2680401
24 November 2004 Hull Examination · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2249151
15 January 2004 Annual Inspection · Administrative Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1968071
5 December 2002 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1718544
4 December 2001 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1480246
2 February 2000 Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1444297
5 December 1998 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1430627
19 February 1998 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1402609
13 December 1996 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1368133
10 November 1995 Hull Examination · Initial Certification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 880625

Deficiency record · 36

09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2023 Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation. The conductor from the alternator to the GPS is not protected with overcurrent protection. 46 CFR 183.380
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 20 March 2024
Resolution: All components installed sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2023 Resolved
Cable and wire for power and lighting circuits must: (1) Meet Section 310-13 of NFPA 70 (incorporated by reference; see 46 CFR 175.600) except that asbestos insulated cable and dry location cables may not be used; (2) Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable; or (3) Meet § 111.60-1 in subchapter J of this chapter for cable, and § 111.60-11 in subchapter J of this chapter for wire. The conductor from the alternator to the GPS is welding cable and not approved. 46 CFR 183.340(d)
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 20 March 2024
Resolution: All components installed sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 March 2023 Resolved
The lights prescribed by these Rules shall, if carried, also be exhibited from sunrise to sunset in restricted visibility and may be exhibited in all other circumstances when it is deemed necessary. The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84). The vessel does not have navigation lights installed onboard. 33 CFR 83.20
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 20 March 2024
Resolution: Nav lights were properly installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. If the cognizant OCMI determines that there is no suitable mounting surface aboard the vessel, the emergency instructions need not be posted but must be carried aboard the vessel and be available to the crew for familiarization. The emergency instructions were not found onboard. 46 CFR 185.510
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 22 May 2023
Resolution: Received photos of emergency instructions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 22 May 2023
Resolution: Received photos of EAP.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2023 Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors. The electrical conductor from the starting battery to the engine is connected using two separate conductors which are attached using a washing screw/bolt and electrical tape. This creates a shock hazard to personnel as well as resistance in the conductor creating a fire hazard. 46 CFR 183.200
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 20 March 2024
Resolution: Properly installed conductor.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 November 2018 Resolved
Each EAP education program must include at least the display and distribution of the employer’s policy regarding drug and alcohol use in the workplace. Owner had no record of signed substance abuse policy for each employee as required by program. Provide record of signed policies for each employee to USCG. - 46CFR16.401(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 28 November 2018
Resolution: Vessel owner submitted signed records of substance abuse policy for each employee.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 November 2018 Resolved
An EAP training program must be conducted for the employer’s crewmembers and supervisory personnel. The training program must include at least the following elements: the effects and consequences of drug and alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer’s supervisory personnel. Supervisory personnel must receive at least 60 minutes of training. Owner had no record of training for crewmembers or supervisor. Provide record of training to USCG. - 46CFR16.401(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 28 November 2018
Resolution: Owner submitted record of training for crewmembers and supervisor.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 November 2018 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Letters and numbers must be at least 50 millimeters (2 inches) high. Markings are faded or missing. Replace. - 46CFR185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 11 December 2018
Resolution: Owner re-stenciled markings for nubmer and size of lifejackets on containers.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 November 2018 Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H–25. Portable fuel tank is not secured. Secure. - 46CFR182.458(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 November 2018
Resolution: Vessel representative secured portable fuel tank with straps.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 May 2018 Resolved
Complete credit drydock prior to carrying passengers. 46 CFR 176.600
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2018
Resolution: Completed credit dry dock.
Construction/Loadline › Structures › Superstructure
Issued 9 November 2017 Resolved
Provide door with securing device to outboard engine. 46CFR177.900
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2017
Resolved 13 November 2017
Resolution: Provided door with securing device to outboard engine to the satisfaction of the Marine Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 November 2017 Resolved
Secure portable fire extinguisher. 46CFR181.500
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Resolution: Portable fire extinguisher secured to the satisfaction of the Marine Inspector.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 November 2017 Resolved
Label bags for adult and child PFDs. 46CFR180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Resolution: PFD storage bags labeled with child, adult, and amount to the satisfaction of the Marine Inspector.
Engineering › Fuel Oil Service System › Valve, Control
Issued 9 November 2017 Resolved
Provide sign for fuel shutoff valves. 46CFR182.455
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Resolution: Fuel shut off sign provided to the satisfaction of the Marine Inspector.
Fire Fighting › Fire Bucket › Stenciling
Issued 9 November 2017 Resolved
Label fire buckets. 46CFR181.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Resolution: Fire buckets labeled to the satisfaction of the Marine Inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 14 November 2016 Resolved
Obtain additional BII fire extinguisher for accommodation space IAW 46 CFR 181.30-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2016
Resolution: PURCHASED NEW FIRE EXTINGUISHERS AND AMENDED COI
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 November 2016 Resolved
Repair cracked welds in diving ladder IAW 46 CFR 176.25-50
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2016
Resolution: REPAIRED ALL CRACKS BY WELDING
Construction/Loadline › Hull › Weld
Issued 21 April 2016 Resolved
Repair crack in center Pontoon to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2016
Resolved 22 April 2016
Resolution: Weld applied to crack in center Pontoon to satisfaction of Marine Inspector.
Construction/Loadline › Structures › Superstructure
Issued 21 April 2016 Resolved
Repair cracks in port side railing welds to satisfaction of Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2016
Resolved 22 April 2016
Resolution: Cracks repaired in port side railing to satisfaction of Inspector.
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 7 December 2015 Resolved
Vessel must prove functionality of propulsion machinery and get underway to conduct drills IAW 46 CFR 185.520.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 December 2015
Resolution: Vessel proved functionality of propulsion machinery.
Lifesaving › Lifebuoys › Serviceable
Issued 7 December 2015 Resolved
Life ring grab line must be replaced IAW 46 CFR 180.70
Due 7 January 2016
Resolved 22 December 2015
Resolution: Installed
Fire Fighting › Fire Bucket › Stenciling
Issued 7 December 2015 Resolved
03 fire buckets must be provided and labeled IAW 46 CFR 181.610.
Due 7 January 2016
Resolved 15 December 2015
Resolution: Fire buckets provided.
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 December 2015 Resolved
Remote fuel shutoff valves must be marked indicating purpose and direction of operation IAW 46 CFR 185.608.
Due 7 January 2016
Resolved 15 December 2015
Resolution: Remote fuel shutoff valves marked.
Fire Fighting › Remote Fuel Shutoff › General
Issued 7 December 2015 Resolved
Properly install fuel shutoff valve at tank connection IAW 46 CFR 182.455(b)(4).
Due 7 January 2016
Resolved 15 December 2015
Resolution: Remote fuel shutoff valves installed at tank connection.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 December 2015 Resolved
Provide proper rail courses to all openings IAW 46 CFR 177.900.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 December 2015
Resolution: Installed
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 7 December 2015 Resolved
Lifejacket stowage must be labeled with proper number of child and adult lifejackets IAW 46 CFR 185.614.
Due 7 January 2016
Resolved 15 December 2015
Resolution: Lifejakcets labeled with proper number of child and adult lifejackets.
Lifesaving › Hand Flares › Storage
Issued 7 December 2015 Resolved
Portable watertight containers of a bright color must be provided for distress signals IAW 46 CFR 185.614.
Due 7 January 2016
Resolved 15 December 2015
Resolution: Portable watertight containers provided for distress signals.
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 7 December 2015 Resolved
Double hose clamps must be placed on each end of the fuel lines IAW 46 CFR 182.720.
Due 7 January 2016
Resolved 15 December 2015
Resolution: Double hose clamps placed on each end of fuel lines.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 10 April 2009 Resolved
Renew 01 adult size PFD.
Action required: 705 - Other - as specified
Resolved 22 April 2009
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 10 April 2009 Resolved
Renew retro on 02 adult size PFD's.
Due 18 April 2009
Resolved 22 April 2009
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 10 April 2009 Resolved
Disinfect vsl of all spiders, ants, roaches and other bugs that exist within the PFD storage compartments and other spaces throughout the vsl.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2009
Lifesaving › Lifebuoys
Issued 4 December 2001 Resolved
Replace 60' of buoyant 3/8' lifeline. Corrected prior to inspection conclusion. LEGACY COMPONENT DESC: Buoyant Lifeline
Due 4 December 2001
Resolved 4 December 2001
Lifesaving
Issued 5 December 1998 Resolved
INSTALL RETROREFLECTIVE TAPE ON RING BUOY._x001C_
Condition: Unknown
Due 22 December 1998
Resolved 22 December 1998
Electrical
Issued 5 December 1998 Resolved
REPAIR OR REMOVE ELECTRICAL PANEL AND DEADEND WIRING IWO STEERING CONSOLE.
Condition: Unknown
Due 23 December 1998
Resolved 23 December 1998
Documentation
Issued 5 December 1998 Resolved
PROVIDE AND POST EMERGENCY PROCEDURES.
Condition: Unknown
Due 11 January 1999
Resolved 11 January 1999

Ownership record