Records from 2016 to 2026. Most recent: inspection, 3 June 2026.
Everything above is free. The detail below — the inspection history, the deficiency record, the operational controls and the documentation record — is Professional, $39 a month. Sign in.
Inspection history · 15
3 June 2026
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8368678
9 June 2025
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8155556
15 November 2024
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8029424
20 March 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7874472
22 May 2023
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7693821
22 March 2023
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7646338
9 February 2021
Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7134616
4 September 2020
Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7041903
11 November 2019
DAPI Audit · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6848544
18 December 2018
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6599842
27 November 2018
COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6579939
3 May 2018
Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6405051
2 November 2017
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6299654
14 November 2016
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6033157
19 April 2016
Deficiency Check · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5857820
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2023
Resolved
Overcurrent protection must be provided for each ungrounded conductor for the purpose of opening the electric circuit if the current reaches a value that causes an excessive or dangerous temperature in the conductor or conductor insulation.
The conductor from the alternator to the GPS is not protected with overcurrent protection.
46 CFR 183.380
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 20 March 2024
Resolution: All components installed sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2023
Resolved
Cable and wire for power and lighting circuits must: (1) Meet Section 310-13 of NFPA 70 (incorporated by reference; see 46 CFR 175.600) except that asbestos insulated cable and dry location cables may not be used; (2) Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable; or (3) Meet § 111.60-1 in subchapter J of this chapter for cable, and § 111.60-11 in subchapter J of this chapter for wire.
The conductor from the alternator to the GPS is welding cable and not approved.
46 CFR 183.340(d)
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 20 March 2024
Resolution: All components installed sat.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 March 2023
Resolved
The lights prescribed by these Rules shall, if carried, also be exhibited from sunrise to sunset in restricted visibility and may be exhibited in all other circumstances when it is deemed necessary. The lights and shapes specified in these Rules shall comply with the provisions of Annex I of these Rules (33 CFR part 84).
The vessel does not have navigation lights installed onboard.
33 CFR 83.20
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 20 March 2024
Resolution: Nav lights were properly installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. If the cognizant OCMI determines that there is no suitable mounting surface aboard the vessel, the emergency instructions need not be posted but must be carried aboard the vessel and be available to the crew for familiarization.
The emergency instructions were not found onboard.
46 CFR 185.510
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 22 May 2023
Resolution: Received photos of emergency instructions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2023
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 22 May 2023
Resolution: Received photos of EAP.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to: (a) Provide services necessary for safety under normal and emergency conditions; (b) Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; (c) Minimize accidental personnel contact with energized parts; and (d) Prevent electrical ignition of flammable vapors.
The electrical conductor from the starting battery to the engine is connected using two separate conductors which are attached using a washing screw/bolt and electrical tape. This creates a shock hazard to personnel as well as resistance in the conductor creating a fire hazard.
46 CFR 183.200
Action required: 705 - Other - as specified
Due 22 May 2023
Resolved 20 March 2024
Resolution: Properly installed conductor.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 November 2018
Resolved
Each EAP education program must include at least the display and distribution of the employer’s policy regarding drug and alcohol use in the workplace.
Owner had no record of signed substance abuse policy for each employee as required by program. Provide record of signed policies for each employee to USCG. - 46CFR16.401(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 28 November 2018
Resolution: Vessel owner submitted signed records of substance abuse policy for each employee.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 27 November 2018
Resolved
An EAP training program must be conducted for the employer’s crewmembers and supervisory personnel. The training program must include at least the following
elements: the effects and consequences of drug and
alcohol use on personal health, safety, and work environment; the manifestations and behavioral cues that may indicate drug and alcohol use and abuse; and documentation of training given to crewmembers and the employer’s supervisory personnel. Supervisory personnel must receive at least 60 minutes of training.
Owner had no record of training for crewmembers or supervisor. Provide record of training to USCG. - 46CFR16.401(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 28 November 2018
Resolution: Owner submitted record of training for crewmembers and supervisor.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 27 November 2018
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. Letters and numbers must be at least 50 millimeters (2 inches) high.
Markings are faded or missing. Replace. - 46CFR185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 December 2018
Resolved 11 December 2018
Resolution: Owner re-stenciled markings for nubmer and size of lifejackets on containers.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 27 November 2018
Resolved
The design, construction, and stowage of portable tanks and related fuel lines and accessories must meet the requirements of ABYC H–25.
Portable fuel tank is not secured. Secure. - 46CFR182.458(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 November 2018
Resolution: Vessel representative secured portable fuel tank with straps.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 May 2018
Resolved
Complete credit drydock prior to carrying passengers. 46 CFR 176.600
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 May 2018
Resolution: Completed credit dry dock.
Construction/Loadline › Structures › Superstructure
Issued 9 November 2017
Resolved
Provide door with securing device to outboard engine. 46CFR177.900
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 November 2017
Resolved 13 November 2017
Resolution: Provided door with securing device to outboard engine to the satisfaction of the Marine Inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 9 November 2017
Resolved
Secure portable fire extinguisher. 46CFR181.500
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Resolution: Portable fire extinguisher secured to the satisfaction of the Marine Inspector.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 9 November 2017
Resolved
Label bags for adult and child PFDs. 46CFR180.71
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Resolution: PFD storage bags labeled with child, adult, and amount to the satisfaction of the Marine Inspector.
Engineering › Fuel Oil Service System › Valve, Control
Issued 9 November 2017
Resolved
Provide sign for fuel shutoff valves. 46CFR182.455
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Resolution: Fuel shut off sign provided to the satisfaction of the Marine Inspector.
Fire Fighting › Fire Bucket › Stenciling
Issued 9 November 2017
Resolved
Label fire buckets. 46CFR181.610
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2017
Resolved 13 November 2017
Resolution: Fire buckets labeled to the satisfaction of the Marine Inspector.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 14 November 2016
Resolved
Obtain additional BII fire extinguisher for accommodation space IAW 46 CFR 181.30-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 November 2016
Resolution: PURCHASED NEW FIRE EXTINGUISHERS AND AMENDED COI
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 14 November 2016
Resolved
Repair cracked welds in diving ladder IAW 46 CFR 176.25-50
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 November 2016
Resolution: REPAIRED ALL CRACKS BY WELDING
Construction/Loadline › Hull › Weld
Issued 21 April 2016
Resolved
Repair crack in center Pontoon to satisfaction of Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2016
Resolved 22 April 2016
Resolution: Weld applied to crack in center Pontoon to satisfaction of Marine Inspector.
Construction/Loadline › Structures › Superstructure
Issued 21 April 2016
Resolved
Repair cracks in port side railing welds to satisfaction of Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2016
Resolved 22 April 2016
Resolution: Cracks repaired in port side railing to satisfaction of Inspector.