Records from 1996 to 2011. Most recent: inspection, 24 February 2011.
Inspection history · 23
24 February 2011
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3849544
14 February 2011
Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3943139
7 April 2010
Hull Examination · Re-Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3712214
18 December 2008
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3382128
19 December 2007
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3117524
23 March 2007
Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2893806
18 August 2006
COI Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2750638
16 November 2005
Hull Examination · Examination of Repairs
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2534521
8 September 2005
Internal Structural Exam · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2485283
16 December 2004
Periodic Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2259951
12 November 2004
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2242338
14 November 2003
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1946209
27 December 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1722665
5 October 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1074309
4 December 2000
Re-Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1429453
13 October 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1418603
29 January 1999
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1430640
13 August 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1131197
1 August 1998
Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 796345
3 December 1997
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1112977
5 February 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1398602
9 October 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 840857
10 January 1996
Initial Construction-Excluding Oversight · Hull Examination · Initial Certification
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1371247
Construction/Loadline › Hull › Hull Plating
Issued 18 December 2008
Resolved
Observed a 2" hole in the deck plating penetrating the stern void IVO the support riser of the hopper coaming. Also, identified 2 areas of major pitting and wastage; deck plating covering the stern void and deck plating between #1 and #2 port wing void hatches. Require insert to repair hole and gauging for the suspect areas.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 22 January 2009
Resolution: A 4'' X 20'' insert on Port deck vicinity of #1 and # 2 wing void and a 6'' X 30'' insert on aft deck.
Documentation
Issued 1 August 1998
Resolved
PROVIDE A LEGIBLE COPY OF THE VESSELS RESPONSE PLAN ONBOARD.
Condition: Unknown
Due 1 August 1998
Resolved 1 August 1998
Documentation
Issued 1 August 1998
Resolved
PROVIDE COPIES OF COI, COD, COFR ON BOARD. ITEM IS TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI PRIOR TO 01 SEPT 1998.
Condition: Unknown
Due 1 August 1998
Resolved 1 August 1998
Construction/Loadline
Issued 1 August 1998
Resolved
REPAINT THE NAME OF THE BARGE IN A CONTRASTING COLOR. ITEM TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI PRIOR TO 01 SEPT 98.
Condition: Unknown
Due 1 August 1998
Resolved 1 August 1998
Lifesaving
Issued 1 August 1998
Resolved
PROVIDE A NEW WARNING SIGN ON BOARD FOR CARGO OPERATIONS.
Condition: Unknown
Due 1 August 1998
Resolved 1 August 1998