MAURY USCG vessel records Sign in
← All vessels

YUE DIAN 82

YUE DIAN 82 is a 1995 freight ship. The Coast Guard has recorded 36 inspections since 1995, most recently in July 2011, along with 13 deficiencies and 8 operational controls.

Records from 1995 to 2011. Most recent: inspection, 8 July 2011.

Built
1995
Last inspected
8 July 2011
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9085936 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
434216
Flag
MARSHALL ISLANDS
—
Maury page id
psix-434216

Inspections, by type

…with no type recorded19
Years with a record 14 calendar years (1995–2011)
The 36 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 15 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it39385 - Convention (Subpart B), Gross Ton
24519 - Convention (Subpart B), Net Ton
81584 - Displacement, Ton
75265 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 36

8 July 2011 Ballast Water Examination · Random ISPS/MTSA/PSC
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4073897
6 July 2011 COE-Offshore · ISPS I Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4060238
6 July 2011 Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4072438
5 November 2010 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3885764
1 November 2010 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3882817
9 May 2009 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3470756
8 December 2008 ISPS I Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3375077
8 December 2008 Type not recorded
No type recorded · Station Little Creek · USCG East District (CGD-E) · Activity 3377262
4 December 2008 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 3374167
17 July 2008 Random ISPS/MTSA-No PSC
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3270337
14 July 2008 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3267758
14 July 2008 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3268276
21 February 2008 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3147516
19 February 2008 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3154504
15 May 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2931536
25 February 2005 PII Safety Exam · Ballast Water Examination
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2299094
19 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2277763
19 January 2005 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2278666
3 November 2004 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2234315
19 August 2004 PII Safety Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 2170379
8 August 2004 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2158710
21 May 2004 MARPOL Annex I Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2074376
29 March 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2033145
29 March 2004 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2033161
5 March 2004 Administrative Inspection
Administrative · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2022172
28 February 2004 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2015480
25 February 2004 Ballast Water Examination · Annual Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2014498
25 February 2004 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2406409
12 July 2002 Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1645445
1 January 2000 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 435996
13 February 1999 Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 425392
19 August 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 419229
31 March 1998 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 413935
1 August 1997 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 406212
20 September 1996 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 395676
4 December 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 385469

Deficiency record · 13

Navigation › Collision/Grounding Avoidance › Radar
Issued 14 July 2008 Resolved
Secondary radar is inoperable. A tech report attesting to the proper operation of the radar is required prior to departure.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2008
Resolution: Received servicing report attesting to repairs of ARPA.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 8 August 2004 Resolved
440V A/C electrical distribution ground detection system does not function as per design.
Condition: Unknown
Action required: 705 - Other - as specified
Due 7 September 2004
Resolved 3 November 2004
Resolution: Received Class Report stating that ground detection system works properly.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 8 August 2004 Resolved
220V A/C electrical distribution ground detection system has a dead ground.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 August 2004
Resolved 19 August 2004
Resolution: Rcvd class report via fax attesting ground was now corrected.
Pollution Prevention/Response › Prevention Equipment
Issued 21 May 2004 Resolved
THE VESSEL IS REQUIRED TO REMOVE BILGE HOLDING TANK DISCHARGE LINE FROM OWS DISCHARGE PIPING. PROVIDE SATISFACTORY CLASS SURVEY REPORT VERIFYING OWS / BILGE HOLDING TANK COMPLIANCE WITH APPLICABLE MARPOL / IMO REGULATIONS. ABOVE ITEM TO BE COMPLETED BEFORE DEPARTURE. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Due 23 May 2004
Resolved 22 May 2004
Resolution: DEFINCIENCY CLEARED BY [name withheld]. KHUCH FITTER ON BEHALF OF CLASS ( RINA ) PROVIDED VERBAL AND WRITTEN STATEMENT THAT THE BILGE HOLDING TANK PIPING/DISCHARGE LINE AND OWS/HOLDING TANK WAS INSTALLED IAW MARPOL/IMO REGULATIONS.
Pollution Prevention/Response › Prevention Equipment
Issued 25 February 2004 Resolved
Observed Oily Water Separator System to have bypass piping connected to oil discharge line. Noted that bypass piping is not in accordance w/ manufacturer's installation instructions. No change is to be made to equipment surveyed without the sanction of the administration. MARPOL 73/78 1/4(4)(b) LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2004
Resolution: Rcv''d class report (XL200456) from RINA sureveyor, F. Sulfaro, on 26Feb2004 certifiying that the bypass was removed and both pipe ends were blanked off. RINA recommends permanent repairs to comply w/MEPC 60/33 by 31MAR2004. USCG verified bypass removal
Pollution Prevention/Response › Prevention Equipment
Issued 25 February 2004 Resolved
Oily Water Separator System found to have bypass piping connected to oil discharge line. System does not automatically stop the discharge of effluent 15ppm w/ bypass system as presently installed. Bypass system to be removed. MARPOL 73/78 Annex 1 Reg. 16(5) LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 February 2004
Resolution: Rcv''d class report (XL200456) from RINA sureveyor, F. Sulfaro, on 26Feb2004 certifiying that the bypass was removed and both pipe ends were blanked off. RINA recommends permanent repairs to comply w/MEPC 60/33 by 31MAR2004. USCG verified bypass removal
Lifesaving
Issued 19 August 1998 Resolved
PROVIDE EVIDENCE OF (END FOR END/RENEWAL) OF LIFEBOAT FALLS AS PER SOLAS 74(AMENDED) III/19.4_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Fire Fighting
Issued 19 August 1998 Resolved
REPAIR AUTOMATIC FIRE ALARM ON BRIDGE IAW WITH SOLAS 74 (AMENDED) II/2 13- 1.4._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Electrical
Issued 19 August 1998 Resolved
DEMONSTRATE TRANSITIONAL EMERGENCY GENERATOR POWER UNDER LOAD FROM DEAD SHIP IAW SOLAS 74 (AMENDED) II-1/43._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Documentation
Issued 19 August 1998 Resolved
PROVIDE ON BOARD CERTIFICATE OF REGISTRY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Documentation
Issued 19 August 1998 Resolved
PROVIDE ON BOARD INTERNATIONAL TONNAGE CERTIFICATION_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Lifesaving
Issued 19 August 1998 Resolved
CONDUCT SATISFACTORY FIRE AND ABANDON SHIP DRILL IAW SOLAS 74 (AMENDED) III/18.3._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1998
Resolved 19 August 1998
Lifesaving
Issued 19 August 1998 Resolved
VESSEL BOARDING REVEALED ISM IMPLEMENTAION NOT EXECUTED. PLAN ONBOARD BUT NOT BEING USED BY SHIP'S CREW._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 17 February 1999
Resolved 17 February 1999

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.