Behind this panel: 7 inspections, each with its date, unit and type; 16 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Lifesaving › Inflatable Liferafts › Servicing
Issued 25 November 2017
Resolved
Every inflatable liferaft shall be serviced at intervals not exceeding twelve months. Vessels liferaft is currently overdue.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2017
Resolved 25 January 2018
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 25 November 2017
Resolved
The ondition of the charges of extinguishers shall be checked annualy. Vesseel has 09 portable fire extinguishers that are overdue.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2017
Resolved 25 January 2018
Navigation › Electronic Positioning › Radio Direction Finding Device
Issued 25 November 2017
Resolved
Vessel shall ensure condition of equipment is maintained after survey. Vessels SART is currently expired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2017
Resolved 25 January 2018
Communications › Radio Communications › EPIRB
Issued 25 November 2017
Resolved
Satellite EPIRB shall be capable of floating free. EPIRB currently stored inside wheelhouse.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 25 November 2017
Resolved 25 January 2018
Engineering › Diesel Engine (auxiliary) › Block
Issued 2 March 2016
Resolved
Internal casualty penetrated crank case.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2016
Resolved 5 March 2016
Resolution: Operator provided alternate power generating source.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 5 January 2016
Resolved
Lifebouy on each side of the ship should be fitted with a bouyant line of at least 30M in length. Bouyant lines on lifebouys were found in wasted condition.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2016
Resolved 10 February 2016
Resolution: Lines replaced
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 January 2016
Resolved
Lifebouy (half # onboard) should be fixed with self-igniting lights. Battery on one lifebouy needs replacement on Port side.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2016
Resolved 10 February 2016
Resolution: battery replaced
Electrical › Electric Supply System (service) › Cable
Issued 5 January 2016
Resolved
Cables and wiring should be installed and supported in such a manner as to avoid chafing and other damage. Cables and wires in tool room are not properly supported.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2016
Resolved 10 February 2016
Resolution: cable/wires properly supported
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 5 January 2016
Resolved
Precaution against shock, fire, and other hazards of electrical origin: Electrical outlets missing covers in various location on board.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2016
Resolved 10 February 2016
Resolution: covers replaced
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 5 January 2016
Resolved
Precaution against shock, fire, and other hazards of electrical origin: Machinery guard cover missing main generator and hydraulic motor pump.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2016
Resolved 10 February 2016
Resolution: guard installed
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 January 2016
Resolved
The bulkhead and decks separating the machinery spaces of category A from control stations, corridors, accommodation spaces, stairways, service spaces and cargo spaces should be so constructed as to be capable of preventing the spread of fire to the exposed side. The cover for the bulkhead opening from the compressor room to berthing is missing.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2016
Resolved 10 February 2016
Resolution: bulkhead cover in place
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 5 January 2016
Resolved
Air pressure systems: The receiver tank is not properly secured in the compressor room.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2016
Resolved 10 February 2016
Resolution: tank secured
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 5 January 2016
Resolved
Insulation materials in the accommodation spaces need not be non-combustible but sould be kept on exposed surfaces. Lagging and insulation materials are missing in crew berthing and galley.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2016
Resolved 10 February 2016
Resolution: lagging in place
Fire Fighting › Fixed Fire Detection System › Alarms
Issued 5 January 2016
Resolved
Fixed fire detection and fire alarm systems shall comply as far as practical with SOLAS 74 Convention. Smoke detectors are missing
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2016
Resolved 10 February 2016
Resolution: smoke detectors in place
Construction/Loadline › Penetrations › Gasket
Issued 5 January 2016
Resolved
Conditions of ship and equipment must be maintained in all respects in order to remain fit to proceed to sea without danger to the ship. Dogs are missing on Port light cover and gasket is damage-compromising watertight integrity.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 February 2016
Resolved 10 February 2016
Resolution: dogs repaired and gasket in place
Fire Fighting › Fire Hydrants › Condition
Issued 5 January 2016
Resolved
Hydrants and pipes shall always be accessible. Water hose is currently covering the main deck fire main and spanner wrench is missing. (corrected on the spot)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2016
Resolution: Corrected on the spot.