Records from 1985 to 2009. Most recent: inspection, 30 March 2009.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 53
30 March 2009
Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3442625
25 February 2009
Administrative Inspection
Administrative · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3423788
15 September 2008
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3356470
6 July 2007
Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 3004675
30 April 2007
Hull Examination
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2918823
12 June 2006
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lewes · USCG East District (CGD-E) · Activity 2677183
17 June 2005
Deficiency Check · COI Inspection · Plan Review "T" Boat
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2393378
17 February 2005
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2294628
25 February 2004
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2012002
4 April 2003
MARPOL Annex V Examination · Administrative Inspection · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1768029
25 March 2003
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1762593
17 August 2002
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1663737
1 April 2002
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1599798
5 February 2002
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1485124
30 May 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1065900
10 April 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1379366
28 February 2001
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1058350
20 March 2000
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1415331
29 February 2000
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 815475
1 April 1999
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1388767
11 February 1999
Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1127547
17 December 1998
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1388723
26 March 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1122513
6 February 1998
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1449009
28 March 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1098829
9 April 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1080724
27 March 1996
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1078594
25 January 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1120445
25 January 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1441026
28 March 1995
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 834433
14 March 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 838733
13 February 1995
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1154834
22 March 1994
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1170391
5 October 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 829522
10 August 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1155831
6 July 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1156524
25 March 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1148663
29 April 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944220
20 March 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1260268
13 March 1992
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 956911
20 March 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 940439
9 October 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909551
27 March 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 931882
21 April 1989
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1343616
30 March 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1198641
3 October 1988
Drydock Extension · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195100
15 April 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1341481
19 February 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1330014
6 April 1987
COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020128
4 March 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1298647
11 December 1985
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304931
5 March 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1285739
25 February 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1285736
Construction/Loadline › Hull › Bottom Plating
Issued 30 March 2009
Resolved
The following areas on the external hull were marked for removal and repair:
-- bow-stem 46 inches below splash rail, an area 3 inches deep by 8 inches long covering the entire with of the stem was found either rotted or filled with wood putty.
-- SB side of Keel, 50 inches forward of the most fwd end of a copper plate that is also located upon the keel. An area of wood rot was discovered.
Action required: 705 - Other - as specified
Resolved 6 April 2009
Resolution: all areas of wood rot, or wood damage had been removed and replaced with cypress planks fastened with 3.5 inch silicone bronze fasteners.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 30 March 2009
Resolved
the most fwd bulkhead of the sewage tank compartment has the shafts passing thru. The subdivision bulkhead and associated plywood stiffener has rotted beneath the shafts, and area 3 inch high by 4 inches wide specifically.
Action required: 705 - Other - as specified
Resolved 6 April 2009
Resolution: proper wood repairs had been completed securing the tightness of this bulkhead.
Construction/Loadline › Penetrations › Valve Flange
Issued 30 March 2009
Resolved
salt water pump valve did not obtain complete closure.
Action required: 705 - Other - as specified
Resolved 6 April 2009
Resolution: salt water pump ball valve had been removed, reworked, and reinstalled. Valve was tested and made complete closure, and held back static water load.
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 23 July 2007
Resolved
Have FFE inspected and serviced as required.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2007
Resolution: FFE inspected.
Lifesaving › Lifefloat › Paddle
Issued 12 June 2006
Resolved
Provide (4) Lifefloat paddles for onboard lifefloats.
Condition: Improper/Lack of Maintenance
Due 19 June 2006
Resolved 15 June 2006
Resolution: (4) lifefloat paddles provided for lifefloats.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 12 June 2006
Resolved
Remove excess oil from engine room bilge.
Condition: Improper/Lack of Maintenance
Due 12 June 2006
Resolved 15 June 2006
Resolution: Excess oil removed from engine room bilge.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 June 2006
Resolved
Provide eyewash and aspirins for first aid kit.
Condition: Improper/Lack of Maintenance
Due 19 June 2006
Resolved 15 June 2006
Resolution: Eyewash and aspirins provided for onboard first aid kit.
Electrical › Electric Supply System (service) › Cable
Issued 17 June 2005
Resolved
Vsl's refridgerator is temporarily wired. Vsl owner to make a permanent electrical power supply to refridgerator.
Condition: Improper/Lack of Maintenance
Due 4 July 2005
Resolved 24 June 2005
Resolution: Vsl owner installed a permanent means of power supply to refridgerator.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 17 June 2005
Resolved
Various portable fire extinguishers are out of date for hydrostatic testing. Vsl to have fire extinguishers serviced by an approved technician.
Condition: Improper/Lack of Maintenance
Due 24 June 2005
Resolved 24 June 2005
Resolution: Portable fire extinguishers were serviced by an approved servicing technician.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 17 June 2005
Resolved
Vsl's forpeak high level bilge alarm inoperable. Repair forepeak high level bilge alarm.
Condition: Improper/Lack of Maintenance
Due 24 June 2005
Resolved 24 June 2005
Resolution: Vsl''s owner repaired forepeak high level bilge alarms. Tested all high level bilge alarms, test satisfactory.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 17 June 2005
Resolved
Deckhand did not hold a current CPR certification. Vsl to provide proof of valid CPR certification.
Condition: Improper/Lack of Maintenance
Due 24 June 2005
Resolved 24 June 2005
Resolution: Deckhand attended a CPR certification class and provided proof of CPR certification.
Construction/Loadline › Hull › Bottom Plating
Issued 17 February 2005
Resolved
Aft end of port chine plank mid-ship split from butt block fasteners. Issued reqt to renew 10' of plank in kind.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 March 2005
Resolved 24 February 2005
Resolution: Witnessed satisfactory installation of plank.
Construction/Loadline › Hull
Issued 25 February 2004
Resolved
Vessel restricted from passenger carriage until a satisfactory post-drydock woodboat check-ride is completed by the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2004
Resolved 1 April 2004
Resolution: Conducted u/w chech ride of wood vessel while conducting annual inspection.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 February 2004
Resolved
Eyewash in first aid kit expired.
Condition: Improper/Lack of Maintenance
Due 7 April 2004
Resolved 7 April 2004
Resolution: Eyewash in first aid kit replaced.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 25 February 2004
Resolved
Fire extinguisher annual certification require by 30 APR 2004.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 17 February 2005
Resolution: Verified annual certification.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 25 February 2004
Resolved
Coast Pilot on the vessel was outdated (20 years old).
Condition: Unknown
Due 7 April 2004
Resolved 7 April 2004
Resolution: New Coast Pilot on board vessel.
Engineering › Bilge Water Management System › Interface Detector
Issued 25 February 2004
Resolved
Ensure proper operation of high level audible and visual alarm in #1 compartment.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 April 2004
Resolved 7 April 2004
Resolution: New light installed and visual/audible alarm successfully tested.
Lifesaving › Lifebuoys
Issued 4 April 2003
Resolved
Replace grabline on life ring.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 4 April 2003
Resolution: Owner provided proof of replacement of grablines on lifebuoys. Receipt from mariner''s mart was faxed to ACTNY.
Lifesaving › Buoyant Apparatus
Issued 4 April 2003
Resolved
Replace grablines and reattach painter on BAs. LEGACY COMPONENT DESC: Grab lines and painter
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 4 April 2003
Resolution: Owner provided receipt from mariner''s mart, 778 Hwy. 36, Belford, NJ 07718 for the purchase of new grablines.
Electrical › Electrical Distribution System (service)
Issued 4 April 2003
Resolved
Remove all dead end wires. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 4 April 2003
Resolution: Owner removed all dead end.
Lifesaving › Lifejacket/PFD (Type I)
Issued 4 April 2003
Resolved
Replace retroreflective tape on (2) two life jackets. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 4 April 2003
Resolution: Owner completed replacing retroreflective tape on life jackets - all sat.
Lifesaving › Buoyant Apparatus
Issued 4 April 2003
Resolved
Stencil vessel name on BVA paddles. LEGACY COMPONENT DESC: Paddles
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 4 April 2003
Resolution: Owner stenciled name of vessel on paddles - all sat.
Lifesaving
Issued 4 April 2003
Resolved
Replenish first aid kit items. LEGACY COMPONENT DESC: First Aid Kit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2003
Resolved 4 April 2003
Resolution: Owner provided proof of replenishment to first aid kit by forwarding receipt of purchase of first aid items from Revere Survival Products.
Electrical › Lighting (emergency)
Issued 1 April 2002
Resolved
Replace emergency 32 volt light bulbs throughout vessel. LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2002
Resolved 1 April 2002
Resolution: Emg lighting corrected
Engineering › Bilge Water Management System
Issued 1 April 2002
Resolved
Install positive stop closure valves to all Rule submersible bilge overboard discharge hoses as needed. Replace lazaret bilge hose with marine grade hose. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2002
Resolved 8 April 2002
Resolution: Positive stop closure valves installed.
Lifesaving › Embarkation Appliances/Stations
Issued 1 April 2002
Resolved
Replace waterlight to lifefloat. LEGACY COMPONENT DESC: Waterlight
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2002
Resolved 8 April 2002
Resolution: Waterlight replaced.
Lifesaving › Embarkation Appliances/Stations
Issued 1 April 2002
Resolved
Provide oars with vessel name marked on them to lifefloats. LEGACY COMPONENT DESC: Oars
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2002
Resolved 8 April 2002
Resolution: Oars provided.
Engineering › Bilge Water Management System
Issued 1 April 2002
Resolved
Prove proper operation of high level alarm in lazaret and forepeak. LEGACY COMPONENT DESC: Alarm
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2002
Resolved 1 April 2002
Resolution: Owner replaced float switch in lazarette and repaired wire in forepeak. All sat.
Fire Fighting › Ventilation Systems
Issued 1 April 2002
Resolved
Provide means to secure ventilation to engine room. LEGACY COMPONENT DESC: Duct Hatches
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2002
Resolved 8 April 2002
Resolution: Means to secure ventilation provided.
Electrical
Issued 10 April 2001
Resolved
Renew improper automotive splice connectors IWO bilge alarms.
Condition: Unknown
Due 10 April 2001
Resolved 10 April 2001
Documentation
Issued 10 April 2001
Resolved
Provide copy of current DAPI contract.
Condition: Unknown
Due 11 April 2001
Resolved 11 April 2001
Lifesaving
Issued 20 March 2000
Resolved
Replace out-of-date (no longer approved) floating waterlights with lights approved under 46CFR161.010
Condition: Unknown
Due 28 March 2000
Resolved 28 March 2000
Lifesaving
Issued 20 March 2000
Resolved
Renew missing netting and platform on both Life Floats in accordance with 46CFR160.027
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000
Electrical
Issued 1 April 1999
Resolved
Replace rheostat on 32 volt charger.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Accommodation/Occupational Safety
Issued 1 April 1999
Resolved
Mark upper deck access with maximum passenger capacity of 31 persons
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Lifesaving
Issued 1 April 1999
Resolved
Replace weak link for buoyant apparatus.
Condition: Unknown
Due 13 April 1999
Resolved 13 April 1999
Lifesaving
Issued 1 April 1999
Resolved
Register 406 Epirb with NOAA. Place registration decal with vessels name on body of Epirb.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Construction/Loadline
Issued 1 April 1999
Resolved
Install check valves IWO bilge piping at bilge suction or manifold linefor each space serviced.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Fire Fighting
Issued 17 December 1998
Resolved
Install a fixed fire fighting system in machinery spaces iaw USCG approved plans.
Condition: Unknown
Due 9 February 1999
Resolved 9 February 1999
Fire Fighting
Issued 17 December 1998
Resolved
Vessel is not to be operated with passengers for hire after 11Mar99 until the above requirements have been cleared to the satisfaction of an attending USCG marine inspector.
Condition: Unknown
Due 9 February 1999
Resolved 9 February 1999
Fire Fighting
Issued 17 December 1998
Resolved
Submit plans for review and approval for the installation of a fixed fire fighting system in the machinery spaces iaw 46CFR181.115(b) and 46CFR181.400.
Condition: Unknown
Due 9 February 1999
Resolved 9 February 1999
Construction/Loadline
Issued 27 March 1996
Resolved
PROVIDE CAPTIVE CHAIN FOR FOREPEAK HATCH.
Condition: Unknown
Due 26 April 1996
Resolved 18 April 1996
Engineering
Issued 27 March 1996
Resolved
REPAIR FLEX JOINT ON STARBOARD EXHUAST IN COMPARTMENT FWD OF LAZ, WATER DRIPPING.
Condition: Unknown
Due 26 April 1996
Resolved 18 April 1996
Engineering
Issued 27 March 1996
Resolved
REPAIR FLEX JOINT ON PORT EXHUAST, LAZ., WATER DRIPPING.
Condition: Unknown
Due 26 April 1996
Resolved 18 April 1996
Deck/Cargo
Issued 27 March 1996
Resolved
PROVE OPERATION OF ANCHOR WINDLESS.
Condition: Unknown
Due 26 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 27 March 1996
Resolved
REPAIR ROTTED SECTIONS AROUND FOREPEAK HATCH IN WAY OF DECK BEAMS.
Condition: Unknown
Due 26 April 1996
Resolved 18 April 1996
Lifesaving
Issued 27 March 1996
Resolved
PROVIDE LANYARD FOR WATERLIGHT ON RING BUOY
Condition: Unknown
Due 26 April 1996
Resolved 18 April 1996
Lifesaving
Issued 27 March 1996
Resolved
PAINT AND MARK PYRO BOX
Condition: Unknown
Due 26 April 1996
Resolved 18 April 1996
Navigation
Issued 27 March 1996
Resolved
REPAIR STERN LIGHT-VSL IS TO OPERATE IN DAYLIGHT HOURS ONLY UNTILL THIS ITEM IS CLEARED.
Condition: Unknown
Due 26 April 1996
Resolved 18 April 1996
Navigation
Issued 27 March 1996
Resolved
PROVIDE UPDATED CHARTS OF AOR.
Condition: Unknown
Due 26 April 1996
Resolved 18 April 1996
Electrical
Issued 14 March 1995
Resolved
LABEL CIRCUIT BREAKERS IN ENGINE COMPT.
Condition: Unknown
Due 14 March 1995
Resolved 14 March 1995
Construction/Loadline
Issued 25 March 1993
Resolved
PROVE PROPER OPERATION OF BILGE PUMP IN LAZARETTE TO COAST GUARD MARINE. TOBE COMPLETED WITH BY 08APR93.
Condition: Unknown
Due 8 April 1993
Resolved 8 April 1993
Lifesaving
Issued 29 April 1992
Resolved
PROVIDE 2 CHILDRENS PFD'S.
Condition: Unknown
Due 29 April 1992
Resolved 29 April 1992
Construction/Loadline
Issued 20 March 1992
Resolved
PROVIDE STRAINERS FOR ALL BILGE SUCTION INLETS. TO BE COMPLETED TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 May 1992
Resolved 8 May 1992
Engineering
Issued 27 March 1990
Resolved
REPAIR STARBOARD REMOTE FUEL SHUTDOWN.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Lifesaving
Issued 27 March 1990
Resolved
PROPERLY ATTACH FLOAT FREE BUOYANT APPARATUS AND REPLACE ALL HANDLINES.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Engineering
Issued 27 March 1990
Resolved
REPAIR REACH ROD FOR FOREPEAK BILGE SUCTION.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Navigation
Issued 27 March 1990
Resolved
PROVIDE UPDATED COAST PILOT.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Navigation
Issued 27 March 1990
Resolved
PROVIDE LIGHT LIST.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Navigation
Issued 27 March 1990
Resolved
PROVIDE 1990 TIDE & CURRENT TABLES.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Lifesaving
Issued 27 March 1990
Resolved
PROVIDE 9 ADULT LIFE JACKETS. THIS REQUIREMENT RESTRICTS THE TOTAL NUMBER OF PERSONS TO 91.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Navigation
Issued 27 March 1990
Resolved
PROVIDE LIGHT FOR COMPASS.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Engineering
Issued 27 March 1990
Resolved
PROVIDE FIXED MEANS OF DEWATERING LAZARETTE.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Construction/Loadline
Issued 27 March 1990
Resolved
PROVIDE POSITIVE CLOSURE VALVES FOR ALL THROUGH HULL PENETRATIONS (4) WITHIN 6" OF THE WATERLINE.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Accommodation/Occupational Safety
Issued 27 March 1990
Resolved
ARRANGE VENTILATION FOR AN ENGINE ROOM VENT TO TERMINATE AT THE BILGE LEVEL.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Fire Fighting
Issued 27 March 1990
Resolved
SERVICE 10 LB DRY CHEM FIRE EXTINGUISHER FOR WHEEL HOUSE.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Lifesaving
Issued 27 March 1990
Resolved
PROVIDE 3 ORANGE SMOKE AND 3 RED FLARE DISTRESS SIGNALS.
Condition: Unknown
Due 27 March 1990
Resolved 27 March 1990
Engineering
Issued 15 April 1988
Resolved
DOUBLE CLAMP FUEL FILL HOSES.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Navigation
Issued 15 April 1988
Resolved
RAISE MASTHEAD LIGHT TO CONFORM W/ANNEX I OF COLREGS.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Documentation
Issued 15 April 1988
Resolved
PROVIDE EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Electrical
Issued 15 April 1988
Resolved
FILL BLANK SPACES IN CIRCUIT BREAKER PANELS IN BRIDGE & ENGINE ROOM.
Condition: Unknown
Due 15 April 1988
Resolved 15 April 1988
Construction/Loadline
Issued 6 April 1987
Resolved
REMOVE NON-ACCESSIBLE SEA VALVE IN ENGINE ROOM FOR SANITARY SYSTEM DISCHARGE AT NEXT DRYDOCK.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Construction/Loadline
Issued 6 April 1987
Resolved
PROVIDE STRAINERS FOR BILGE SUCTIONS WHERE MISSING.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Construction/Loadline
Issued 6 April 1987
Resolved
PROVIDE NON-RETURN VALVES AND REINFORCED HOSE FOR THE 4 ELECTRICAL BILGE PUMPS OF THE SECONDARY BILGE SYSTEM.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Unknown
Issued 6 April 1987
Resolved
INSTALL ALTERNATE VENTILATION FOR ENGINE ROOM AND FUEL TANK SPACE.
Condition: Unknown
Due 6 April 1987
Resolved 6 April 1987
Deck/Cargo
Issued 5 March 1985
Resolved
REMOVE ALL PLASTIC BILGE PIPING AND VALVES FROM THE VESSEL BILGE PIPING SYSTEM. REPLACE WITH AN APPROVED MATERIAL.
Condition: Unknown
Due 5 March 1985
Resolved 5 March 1985